Digital Electronics Corporation PL7900-T42, PL7901-T42, PL6900-T42, PL6901-T42 Installation Manual

PL7900-T42/PL7901-T42
Installation Guide
WARNINGS
• To prevent an electric shock, be sure to connect the power cord to the PL before connecting it to the main power supply.
• A fire or electrical shock may occur if voltages used with the PL are beyond the specified range. Be sure to use only the specified voltage.
• Before opening the PL’s protective cover, be sure to turn the unit’s power OFF. This is because the PL’s internal parts carry high voltages.
• To avoid fires or electrical hazards, do not modify the PL in any way.
• Do not create touch panel switches that are used to either control or to ensure the safety of equipment and personnel. Mechanical switches, such as an emergency stop switch, a deadman (two-handed) start switch, etc., must be installed and operated via a separate control system.
• Do not create touch panel switches which could possibly endanger the safety of humans or equipment. This is due to the possibility of a malfunction in the GP or its cable(s) causing the output of a signal that could result in a major accident. All of a system's major, safety-related switches should be designed to be operated separately from the GP.
• After the PL’s backlight burns out, unlike the PL’s “Standby Mode”, the touch panel is still active. If the operator fails to notice that the backlight is burned out and touches the panel, a potentially dangerous machine miss-operation can occur. If your PL's backlight suddenly turns OFF, use the following steps to determine if the backlight is actually burned out.
1) If your PL is not set to "Standby Mode" and the screen has gone blank, your backlight is burned out.
2) Or, if your PL is set to Standby Mode, but touching the screen does not cause the display to reappear, your backlight is burned out.
• If metal particles, water or other types of liquids contact any of the PL’s internal parts, immedi­ately turn the unit’s power OFF, unplug the power cord, and contact either your PL distributor or the Digital Electronics Corporation.
• Before either plugging in or unplugging a board or interface connector, be sure to turn the PL’s power OFF.
• To prevent a possible explosion, do not install the PL in areas containing flammable gases.
• The PL is not appropriate for use with aircraft control devices, aerospace equipment, central trunk data transmission (communication) devices, nuclear power control devices, or medical life support equipment, due to these devices’ inherent requirements of extremely high levels of safety and reliability.
• When using the PL with transportation vehicles (trains, cars and ships), disaster and crime prevention devices, various types of safety equipment, non-life support related medical devices, etc. redundant and/or fail-safe system designs should be used to ensure the proper degree of reliability and safety.
To Prevent Accidents
• Do not push on the PL’s screen too strongly, with either your finger or with a hard object. Exces­sive pressure can scratch, crack or damage the screen. Do not use a pointed object, such as a mechanical pencil or screwdriver, to press any of the touch panel’s switches, since they can damage the display.
• Avoid storing and operating the PL in direct sunlight, high temperatures and humidity, and in areas where excessive dust and vibration will occur.
• Avoid using the PL in areas where sudden, extreme changes in temperature can occur. This may cause condensation to form inside the unit, possibly leading to an accident.
• To prevent the PL from overheating, be sure its air circulation vents are clear and clean, and keep the unit’s operation area well-ventilated.
• Avoid operating or storing the PL near chemicals, or where chemicals can come into contact with the unit.
• The Digital Electronics Corporation cannot be held responsible or provide any compensation for damage(s) caused by the loss of data stored in the PL™s hard disk drive (HDD). It is therefore strongly suggested that all important data and software be backed up regularly to an external data backup device.
• After turning OFF the PL's power, wait until the internal HDD stops spinning before turning on the power again (approx. 5 seconds).
1
UL/c-UL (CSA) Application Notes
The PL790*-T4* is UL/c-UL 1950 recognized product. (UL File No. E171486). Please pay special attention to the following instructions when applying for UL/c-UL approval for ma­chinery which includes any of these PL units.
The PL conforms as a component to the following standards:
UL 1950, Third Edition, dated March 1,1998 (Standard for Safety of Information Technology Equipment, including Electrical Business Equipment) CSA-C22.2 No. 950-95 (Standard for Safety of Information Technology Equipment, includ­ing Electrical Business Equipment)
PL7900-T4* (UL Registration Model No.: 2780054-02) PL7901-T4* (UL Registration Model No.: 2780054-01)
- Equipment with a PL mounted in it requires UL/c-UL evaluation for the combination of the PL
and equipment.
- The PL must be used as a built-in component of an end-use product.
- Use the PL indoors only.
- When connecting the PL’s power cable, be sure to use a cable that is appropriate for the current
and voltage used and that has conductive wires that are 0.75 mm2 or larger.
- When using the PL in an end-use product, be sure to install the PL unit's power cut-off switch
where the operator can easily reach it.
- Danger of explosion if backup battery is incorrectly replaced. Replaced only with same or
equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
- Be sure the unit the PL is built into uses a UL1950 compatible equipment structure.
CE Marking Notes
The PL790*-T4* units are CE marked, EMC compliant products.
<Complies with the following Standards>
• Safety
EN60950
• EMI (EN50081-2)
EN55011 group1 (Class A)
• EMS (EN50082-2)
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-6, EN61000-4-8, ENV50204 If following requirements are not met, the PL may fail to meet EN60950 standard requirements.
• Equipment with a PL mounted in it requires UL/c-UL evaluation for the combination of the PL
and equipment.
• The PL must be used as a built-in component of an end-use product.
• Use the PL indoors only.
• When connecting the PL’s power cable, be sure to use a cable that is appropriate for the current
and voltage used and that has conductive wires that are 0.75 mm2 or larger.
• When using the PL in an end-use product, be sure to install the PL unit's power cut-off switch
where the operator can easily reach it.
• There is a danger of explosion if the backup battery is incorrectly replaced. This battery should
be replaced only with same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
• Be sure the PL unit's enclosure is an EN60950 approved sheet steel structure.
2
Package Contents
The PL package should include the following items:
!!
! PL Unit
!!
(PL-7900T/PL-7901T)
Be careful when installing the PL not to damage the built-in HDD.
!!
! Floppy Disks (3)
!!
(PL-X900 Series Driver & Utility Disk)
!!
! Power Cord
!!
This cord is designed only for AC100/115V use. Any other volt­age will require a different cable.
!!
! CD-ROM (1)
!!
contains PDF manual file
!!
! Installation Brackets (12)
!!
!!
! Installation Guide
!!
(2 - English and Japanese)
This
Guide
About The Manual
The CD-ROM contains the following PDF manual file.
PL-7900/7901 Series User Manual
Reading a PDF file requires installation of the Adobe Corporation’s Acrobat® Reader.
!Acrobat® Reader Installation:
To install the Acrobat® Reader software, follow the steps given below.
1) This software, in the form of a self-extracting file, is located in this CD-ROM in the folder titled [reader]. Use the Explorer software to find the file [reader\ENG\ar405eng.exe], and double-click on the file icon to begin the Reader installation.
2) After Installation begins, follow the instructions given on the Installation screens.
!Viewing the PDF manual:
To view the PDF manual contained in this CD-ROM, follow the steps given below.
1) Use the Explorer software to locate the file [manual\ENG\pl7900e.pdf] in the folder titled [manual].
2) Double-click on the PDF file's icon. Acrobat® Reader will automatically start and the first page of the PDF manual will appear.
3
1 PL External Features
C
A B
A : Display Area
B : Touch Panel
C : Power Lamp LED
D : Front Maintenance Cover
<Inside the front main­tenance cover>
PL-7900T
(4Slot)
Q
R
E : IrDA
D
E
F : Keyboard Connector
G : Hardware Reset Switch
I
GH
F
L
MJK
N
H : FDD Slot (only for PL-7900T)
I : Brightness Adjustment Slide
J : RS-232C Connector (COM1)
K : RS-232C Connector (COM2)
L : RS-232C Connector (COM3)
M : Printer Connector (LPT1)
N : RAS Connector
O : Power Terminals
H
P
O
P : IDE I/F Cover
V
T
Q : Keyboard Connector
R : Mouse Connector
S
X
U
S : FDD Slot
T : Expansion Slots (2)
W
PL-7900T(4Slot)
U : HDD/FFD Expansion Unit Slot
V : Half Cover
W: Power Switch
X : Rear Maintenance Cover
PL-7900T(4Slot)
• Prior to attaching peripheral units to the PL, be sure the PL’s power cord
is disconnected from the main power supply.
• To prevent an electrical shock, be sure to disconnect the PL’s power cord from
the power supply before connecting the cord’s power terminals or any periph­eral devices to the PL.
4
2 PL Dimensions
• PL-7900T General Dimensions
359 [14.13]
Top View
374 [14.72]
(Unit: mm [in.] - excluding projections)
180 [7.09]
13 [0.51]
Front View
• PL-7901T General Dimensions
359 [14.13]
Top View
374 [14.72]
325 [12.80]
Side View
(Unit: mm [in.] - excluding projections)
134 [5.28]
13 [0.51]
310 [12.20]
Front View
325 [12.80]
5
310 [12.20]
Side View