Digital Alert Systems R198 User Manual

INSTRUCTION MANUAL
4 UNIT AES SWITCH
MODEL R198
S/N ________
IF FOR SOME REASON YOU HAVE TO RETURN THIS ITEM TO THE FACTORY FOR ANY SERVICE OR REPAIR, YOU MUST CONTACT CUSTOMER SERVICE
NUMBER AT (585) 765-2254
RMA
100 Housel Ave. Lyndonville, N.Y. 14098
Phone: (585)-765-1155 FAX: (585)-765-9330
P/N: R198/100 REVISION DATE:04/12/12
TABLE OF CONTENTS
WARRANTY
GENERAL DESCRIPTION and APPLICATION
SPECIFICATIONS
INSTALLATION
CONFIGURATION AND ADJUSTMENTS
SETTING UP ETHERNET INTERFACE 9
3
4
5
6
8
2
WARRANTY
Digital Alert Systems / Monroe Electronics, Inc. warrants to the owners, each instrument and sub­assembly manufactured by them to be free from defects in material and workmanship for a period of two years after shipment from factory. This warranty is applicable to the original purchaser only.
Liability under this warranty is limited to service, adjustment or replacement of defective parts (other than fuses or batteries) on any instrument or sub-assembly returned to the factory for this purpose, transportation charges prepaid.
This warranty does not apply to instruments or sub-assemblies subjected to abuse, abnormal operat­ing conditions, or unauthorized repair or modification.
Since Digital Alert Systems / Monroe Electronics, Inc. has no control over conditions of use, no war­ranty is made, or implied as to the suitability of our product for the customer’s intended use.
THE WARRANTY SET FORTH IN THIS ARTICLE IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRAN­TIES AND REPRESENTATIONS, EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANT ABILITY AND FITNESS. Except for obligations expressly undertaken by Digital Alert Systems / Monroe Electronics, Inc., in this warranty, Owner hereby waives and releases all rights, claims and remedies with respect to any and all warranties, express, implied or statutory (including without limitation, the implied warranties of merchant ability and fitness), and including but without being limited to any obligation of Digital Alert Systems / Monroe Electronics, Inc. with respect to incidental or consequential damages, or damages for loss of use. No agreement or understanding varying or extending the warranty will be binding upon Digital Alert Systems / Monroe Electronics, Inc. unless in writing signed by a duly authorized representative of Digital Alert Systems / Monroe Electronics, Inc.
In the event of a breach of the foregoing warranty, the liability of Digital Alert Systems / Monroe Electronics, Inc.shall be limited to repairing or replacing the non-conforming goods and/or defective work, and in accordance with the foregoing, Digital Alert Systems / Monroe Electronics, Inc. shall not be liable for any other damages, either direct or consequential.
RETUR N P OLI C Y TO FAC TORY:
Materials returned must have a Return Material Authorization number. To obtain a RMA number, contact our l Customer Service at 585-765-1155 or fax 585-765-9330. Customers have 30 days to deter­mine that the product ordered fills their need and performs as described in Digital Alert Systems / Monroe Electronics, Inc. literature. Units returned for approved repair or credit, must be in the origi­nal packaging including all parts and paperwork plus be in very good physical condition. If not, the customer is billed the cost to refurbish the unit and for missing accessories and merchandise. No products may be returned for exchange or credit after 12 months of the shipment date. Digital Alert Systems / Monroe Electronics, Inc. reserves the right to repair or replace units under warranty.
3
GENERAL DESCRIPTION and APPLICATION
The Monroe Electronics Model R198 is a network controlled multichannel Analog to Digital convertor and AES program switching system, used to insert EAS alerts into Broadcast Audio Streams.
The unit features an unbalanced analog mono audio master input or unbalanced stereo master input, and 4 independent AES program in’s and out’s. Each output can be seamlessly switched from its incoming AES stream to the Master input (converted to AES) via network control from the DASDECII EAS Controller.
A master GPI switch will switch all four channels at once, or individual switches are available at each channel connector for control.
The individual AES channels feature a fail-safe bypass to maintain signal integrity in the event of a power failure and can be configured for either 44.1KHz or 48 KHz data rates. The network interface follows the standard Monroe R190A/R197 protocol for 10/100 base T Ethernet interfacing to a DASDEC.