Digisol DG-GS4526P Installation Manual

Page 1
DG-GS4526P
22 PORT 10/100/1000MBPS LAYER 2 POE
SWITCH WITH 4 GC PORTS
Installation Guide
V1.2
As our products undergo continuous development the specifications are subject to change without prior notice
Page 2
DG-GS4526P Installation Guide Content
2
Content
CHAPTER 1 INTRODUCTION.......................................................3
1.1 PRODUCT BRIEF ....................................................................................3
1.1.1 Overview................................................................................................... 3
1.1.2 Features and Benefits ............................................................................. 3
1.2 PHYSICAL SPECIFICATIONS.....................................................................4
1.3 DESCRIPTION OF HARDWARE ..................................................................5
1.3.1 Front Panel............................................................................................... 5
1.3.2 Back Panel................................................................................................ 5
1.3.3 Status LEDs.............................................................................................. 5
1.3.4 PoE Indication Description.....................................................................6
1.3.5 Front Panel Port Description .................................................................. 8
CHAPTER 2 HARDWARE INSTALLATION..................................9
2.1 INSTALLATION NOTICE............................................................................9
2.1.1 Environmental Requirements................................................................. 9
2.1.2 Installation Notice.................................................................................. 13
2.1.3 Security Warnings ................................................................................. 13
2.2 INSTALLATION PREPARATION................................................................14
2.2.1 Verify the Package Contents................................................................. 14
2.2.2 Required Tools and Utilities.................................................................. 14
2.3
INSTALLATION GUIDE ...........................................................................14
2.3.1 Installing the Switch..............................................................................14
2.3.2 Connecting Console.............................................................................. 15
2.3.3 SFP Transceiver Installation.................................................................16
2.3.4 Copper Cable/Fiber Cable Connection ................................................ 16
2.3.5 Power Supply Connection .................................................................... 17
Page 3
DG-GS4526P Installation Guide
Chapter 1 Introduction
1.1 Product Brief
DG-GS4526P:
Fig 1-1 DG-GS4526P Switch
1.1.1 Overview
DG-GS4526Pseries switch with advanced intelligent and secure features, can serve ideally as distribution layer switches for the 1000Mb input device of campus networks, enterprise networks and IP metropolitan networks.
1.1.2 Features and Benefits
Various Interfaces
DG-GS4526Pseries switch provides multiple fixed 10/100/1000Base-t ports and SFP COMBO ports.
Networking Protocols
DG-GS4526Pseries switch support 802.1d/w/s, 802.1Q, 802.1p, 802.3ad, 802.3x, GVRP, DHCP and SNTP etc.
3
ACL
DG-GS4526Pseries switch support comprehensively ACL policies. The traffic can be classified by source/destination IP addresses, source/destination MAC addresses, IP protocols, TCP/UDP, IP precedence, time ranges and ToS. And various policies can be conducted to forward the traffic. By implementing ACL policies, users can filter the virus packets such as “Worm.Blaster”, “W orm.Sasser” and “Red Code” etc. DG-GS4526Pseries switch also support IEEE802.1x port based access authentication, which can be deployed with RADIUS, to ensure the port level security and block illegal users.
Page 4
DG-GS4526P Installation Guide
4
QoS
DG-GS4526P series switch fully support DiffServ Module. Users can specify a queue bandwidth on each port. WRR/SP/SWRR scheduling is also supported. DG-GS4526Pseries support the port security. Users can deploy trusted CoS, DSCP, IP precedence and port priority. User can also modify packets’ DSCP and COS values. The traffic can be classified by port, VLAN, DSCP, IP precedence and ACL table. User can also modify packets’ DSCP and IP precedence values. Users can specify different bandwidths for voice/data/video to customize different qualities of service.
3D-SMP Ready
DG-GS4526P series are up to the mustard of Self-defending security region management strategy. It is supported interaction with some security system such as firewall,IDS,etc. It can defense the virus and aggress effectively from the extranet and internet. Thus enhance the security and stability of the network-wide.
Perfect Web Management.
DG-GS4526Pseries support SNMP, In-band and Out-of band Management ,CLI and WEB interface and RMON. It can mail the correlative sensitive information to the administrator abide by SMTP protocol. DG-GS4526Pseries support SSH protocol, ensure the configuration management security of the switch.
1.2 Physical Specifications
Management Port
1 RJ-45 serial console port
AC/DC Power Input
AC: 100 ~ 240VAC50 ~ 60Hz
Power Consumption
DG-GS4526P: 225W Max (PoE module is 180W)
Operating Temperature
0°C ~ 50°C
Storage Temperature
-40°C ~ 70°C Relative Humidity
5% ~ 95%, no condensate Dimension
DG-GS4526P: 440mm×44mm×410mm (W * H * D) Weight
DG-GS4526P: Approximate 4kg
Mean Time Between Failure
Page 5
DG-GS4526P Installation Guide
Min. 80, 000 Hours MTBF
1.3 Description of Hardware
1.3.1 Front Panel
DG-GS4526P has 22 10/100/1000Base-T ports, 4 Combo ports (4 RJ-45 and 4 SFP),
1 Console port and 32 LEDs.
The front panel of DG-GS4526P is shown below:
Fig 1-2 Front Panel of DG-GS4526P
1.3.2 Back Panel
Fig 1-3 Back
Panel of DG-GS4526P
1.3.3 Status LEDs
DG-GS4526Pseries include port indications and system status indication are shown below.
1.3.3.1 Port indication Description
Fig 1-4 DG-GS4526P LED diagram
5
Page 6
DG-GS4526P Installation Guide
Table 1-1 DG-GS4526P port indications description
Panel S
ymbol Status Description
On (Yellow)
On means ports are in the link state of 10Mbps or 100Mbps
Flash(Yellow)
On means ports are in the link state of 10Mbps or 100Mbps, and receive/send data
On (Green)
On means ports are in the link state of 1000Mbps
Flash(Green)
On means ports are in the link state of 1000Mbps, and receive/send data
Port1-24(Link/A ct)
Off The ports are not in the link On (Green) SFP module is in place
Port21/22/23/24
Off SFP module is not in place
On (Yellow)
On means ports are in the link state of 10Mbps or 100Mbps
Flash(Yellow)
On means ports are in the link state of 10Mbps or 100Mbps, and receive/send data
On (Green)
On means ports are in the link state of 1000Mbps
Flash(Green)
On means ports are in the link state of 1000Mbps, and receive/send data
Port25/26
Off The ports are not in the link
1.3.3.2 System Status Indication Description
1.3.4 PoE Indication Description
Fig 1-5 DG-GS4526P LED diagram
6
Page 7
DG-GS4526P Installation Guide
Table 1-2 DG-GS4526P indication description
LED Status Description
Green
Port LEDs display the PoE state of each port
Flash (Amber)
The total power of PoE output reach to the max value 95% or the remain power is not supply power to a new PoE port
PoE Status
Off
Port LEDs display “Link/Act” state of each port
When the PoE S
tatus is not off, this port indication is PoE status. Amber means power is
operating normally, Off means power is off.
7
Page 8
DG-GS4526P Installation Guide
8
1.3.5 Front Panel Port Description
Each port description are shown below:
Table 1-3 DG-GS4526P port description
Interface mode Spec
RJ-45 port
10/100/1000Mbps auto negotiation  MDI/MDI-X cable mode auto negotiation
5 kinds of UTP100 m
SFP
SFP-SX transceiver
62.5/125um multi-mode fiber275m
50.0/125um multi-mode fiber550m
SFP-LX transceiver
9/125um single mode fiber10km
SFP-LH-40 transceiver
9/125um single mode fiber40km
SFP-LH-70 transceiver
9/125um single mode fiber70km
SFP-LH-120 transceiver
9/125um single mode fiber:120km
Page 9
DG-GS4526P Installation Guide
9
Chapter 2 Hardware Installation
2.1 Installation Notice
To ensure the proper operation of DG-GS4526Pseries and your physical security,
please read carefully the following installation guide.
2.1.1 Environmental Requirements
The switch must be installed in a clean area. Otherwise, the switch may be damaged
by electrostatic adherence.
Maintain the temperature within 0 to 50 °C and the humidity within 5% to 95%,
non-condensing.
The switch must be put in a dry and cool place. Leave sufficient spacing around the
switch for good air circulation.
The switch must work in the right range of power input (AC power: 100 ~
240VAC
(
50Hz))
The switch must be well grounded in order to avoid ESD damage and physical injury
of people.
The switch should avoid the sunlight perpendicular incidence. Keep the switch away
from heat sources and strong electromagnetic interference sources.
The switch must be mounted to a standard 19’’ rack or placed on a clean level
desktop.
2.1.1.1 Dust and Particles
Dust is harmful to the safe operation of DG-GS4526P series. Dust can lead to electrostatic adherence, especially likely under low relative humidity, causing poor contact of metal connectors or contacts. Electrostatic adherence will result in not only reduced product lifespan, but also increased chance of communication failures. The recommended value for dust content and particle diameter in the site is shown below:
Max Diameter (µm) 0.5 1 3 5 Max Density
(particles/m³)
1.4×10
7
7×105 2.4×105 1.3×105
Table 2-1Environmental Requirements: Dust
Page 10
DG-GS4526P Installation Guide
10
In addition, salt, acid and sulfide in the air are also harmful to the switch. Such harmful gases will aggravate metal corrosion and the aging of some parts. The site should avoid harmful gases, such as SO
2
, H2S, NO2, NH3 and Cl2, etc. The table below details the
threshold value.
Gas Average (mg/m³) Max (mg/m³) SO2 0.2 1.5 H2S 0.006 0.03 NO2 0.04 0.15 NH3 0.05 0.15 Cl2 0.01 0.3
Table 2-2 Environmental Requirements: Particles
2.1.1.2 Temperatur e and Humidity
The switch install site should maintain a desirable temperature and humidity. High-humidity conditions can cause electrical resistance degradation or even electric leakage, degradation of mechanical properties and corrosion of internal components. Extreme low relative humidity may cause the insulation spacer to contract, making the fastening screw insecure. Furthermore, in dry environments, static electricity is liable to be produced and cause harm to internal circuits. Temperature extremes can cause reduced reliability and premature aging of insulation materials, thus reducing the switch’s working lifespan. In the hot summer, it is recommended to use air-conditioners to cool down the site. And the cold winter, it is recommenced to use heaters.
The recommended temperature and humidity is shown below:
Temperature: Relative humidity Long term condition Short term condition Long term condition Short term
condition
15 ~ 30°C 0 ~ 50°C 40 ~ 65% 5 ~ 95%
Table 2-3 Environmental Requirements: Temperature and Humidity
Page 11
DG-GS4526P Installation Guide
11
Caution! A sample of ambient temperatur e and humidity should be taken at 1.5m above the floor and 0.4m in front of the switch rack, with no protective panel covering the front and rear of the rack. Short term working conditions refer to a maximum of 48 hours of continued operation and an annual cumulative total of less than 15 days. Formidable operation conditions refers to the ambient temperature and relative humidity value that may occur during an air-conditioning system failure, and normal operation conditions should be recovered within 5 hours.
2.1.1.3 Power Supply
It is adopted module switch power for the switch, the input parameter of power is shown below:
The AC input voltage: 100~240VAC
The frequency: 50~60Hz
Before powering on the power supply, please check the power input to ensure proper grounding of the power supply system. The input source for the switch should be reliable
and secure a voltage adaptor can be used if necessary. The building’s circuit protection
system should include in the circuit a fuse or circuit-breaker of no greater than 240 V, 10 A. It is recommended to use a UPS for more reliable power supplying. .
Caution!
Improper power supply system grounding, extreme fluctuation of the input source, and transients (or spikes) can result in larger error rate, or even hardware damage!
2.1.1.4 Preventing Electrostatic Discharge Damage
Static electric discharges can cause damage to internal circuits, even the entire switch. Follow these guidelines for avoiding ESD damage:
Ensure proper earth grounding of the device; Perform regular cleaning to reduce dust; Maintain proper temperature and humidity; Always wear an ESD wrist strap and antistatic uniform when in contact with circuit
boards.
Page 12
DG-GS4526P Installation Guide
12
2.1.1.5 Anti-interference
All sources of interference, whether from the device/system itself or the outside environment, will affect operations in various ways, such as capacitive coupling, inductive coupling, electromagnetic radiation, common impedance (including the grounding system) and cables/lines (power cables, signal lines, and output lines). The following should be noted:
Precautions should be taken to prevent power source interruptions; Provide the system with a dedicated grounding, rather than sharing the grounding
with the electronic equipment or lightning protection devices. Keep away from high power radio transmitters, radar transmitters, and high frequency
strong circuit devices. Provide electromagnetic shielding if necessary.
2.1.1.6 Rack Configuration
The dimensions of the DG-GS4526P series are designed to be mounted on a standard 19’’ rack, DG-GS4526P’ s dimensions are 440mm x 44mm x 410mm (W x H x D). Please ensure good ventilation for the rack.
Every device in the rack will generate heat during operation, therefore vent and fans
must be provided for an enclosed rack, and devices should not be stacked closely. When mounting devices in an open rack, care should be taken to prevent the rack
frame from obstructing the switch ventilation openings. Be sure to check the
positioning of the switch after installation to avoid the aforementioned. Caution
If a standard 19’’ rack is not available, the DG-GS4526P series can be placed on a clean level desktop, leave a clearance of 100mm around the switch for ventilation, and do not place anything on top of the switch.
Page 13
DG-GS4526P Installation Guide
13
2.1.2 Installation Notice
Read through the installation instruction carefully before operating on the system.
Make sure the installation materials and tools are prepared. And make sure the
installation site is well prepared. During the installation, users must use the brackets and screws provided in the
accessory kit. Users should use the proper tools to perform the installation. Users
should always wear antistatic uniform and ESD wrist straps. Users should use
standard cables and connecters. After the installation, users should clean the site. Before powering on the switch,
users should ensure the switch is well grounded. Users should maintain the switch
regularly to extend the lifespan of the switch.
2.1.3 Security Warnings
When using SFP transceiver, do not stare directly at the fiber bore when the switch is
in operation. Otherwise the laser may hurt your eyes. Do not attempt to conduct the operations which can damage the switch or which can
cause physical injury. Do not install, move or disclose the switch and its modules when the switch is in
operation.
Do not open the switch shell. Do not drop metals into the switch. It can cause short-circuit. Do not touch the power plug and power socket. Do not place the tinder near the switch. Do not configure the switch alone in a dangerous situation, Use standard power sockets which have overload and leakage protection. Inspect and maintain the site and the switch regularly. Have the emergence power switch on the site. In case of emergence, switch off the
power immediately. Caution!
Potential risk include: Electric leakage,Power supply arcing, Power line breakage, Imperfect earth, Overload circuit and Electrical short circuit..If electric shock, fire,electrical short circuit occurs,please cut off the electricity supply and alarm rapidly. Rescue the injured person in the contingency under inherently safe,Give the injured person proper first aid treatment according to the injury state,and seek help from the Medical Emergency using various ways
Page 14
DG-GS4526P Installation Guide
2.2 Installation Preparation
2.2.1 Verify the Package Contents
First, open the package, please check the contents of the switch container and accessory kit. (If you are concerned that any item is missing or an incorrect item has been supplied, please contact your dealer as soon as possible.)
2.2.2 Required Tools and Utilities
The required tools and utilities are shown below:
Cross screwdrivers
Flat-blade screwdriver
ESD wrist strap
Antistatic uniform
Caution!
Users should prepare the required tools and utilities by themselves.
2.3 Installation Guide
2.3.1 Installing the Switch
Please mount DG-GS4526Pseries switch as below:
1. Attach the 2 brackets on the DG-GS4526P eries with screws provided in the accessory kit.
Fig 2-1 Fasten the Brackets to the Switch
14
2. Put the bracket-mounted switch smoothly into a standard 19’’ rack. Fasten the DG-GS4526P series to the rack with the screws provided. Leave enough space around the switch for good air circulation.
Page 15
DG-GS4526P Installation Guide
Fig 2-2 Fasten the Switch to the Rack
Caution! The brackets are used to fix the switch on the rack. They can’t serve as a bearing. Please place a rack shelf under the switch. Do not place anything on top of the switch. Do not block the blowholes on the switch to ensure the proper operation of the switch.
2.3.2 Connecting Console
DG-GS4526Pseries provide a serial RJ45 console port.
Fig 2-3 Connecting Console to DG-GS4526P
The connection procedure is listed below:
1. Find the console cable provided in the accessory kit. Attach the RJ45 end to console
port of the switch.
15
Page 16
DG-GS4526P Installation Guide
2. Connect the other side of the console cable to a character terminal (PC).
3. Power on the switch and the character terminal. Configure the switch through the
character terminal.
2.3.3 SFP Transceiver Installation
DG-GS4526Pseries provide multiple 1000Mb SFP transceiver slots. The procedure for installing the SFP transceiver is shown below: Step 1: Put on a ESD wrist strap (or antistatic gloves) Step 2: Insert the SFP transceiver to the guide rail inside the fiber interface line card. Do not put the SFP transceiver up-side-down. Step 3: Push the SFP transceiver along the guide rail gently until you feel the transceiver snap into place at the bottom of the line card. Note: the SFP transceiver is hot swappable.
Caution! Do not stare directly at the 2 fiber bore in the SFP transceiver when the switch is in operation, otherwise the laser may hurt your eyes.
2.3.4 Copper Cable/Fiber Cable Connection
Copper cables should be connected as below: Step 1: Insert one end of the Ethernet cable to the RJ-45 Ethernet port in the switch copper cable line card; Step 2: Insert the other end of the Ethernet cable to the RJ-45 Ethernet port of some other device; Step 3: Check all status indicators for the corresponding ports; a lighted LED indicates that the link has been established, otherwise the link is not ready and the cable should be examined.
Caution! Please verify the sign above the port to ensure using the right port. Connecting to wrong ports might damage the switch.
16
Page 17
DG-GS4526P Installation Guide
Fiber cables should be connected as below: Step 1: remove the protective plug from the SFP/XFP fiber transceiver bore; Remove the protective cap from one end of the fiber cable. Keep the fiber end clean and neat. Step 2: Attach one end of the fiber cable to the SFP/XFP transceiver, and attach the other end to the transceiver of the other devices. Note: SFP/XFP transceiver’s TX port should be connected to RX port of other device, and SFP/XFP transceiver’s RX port should be connected to TX port of other device. Step 3: Check the fiber port status indicator, a light LED indicates that the link has been established; otherwise the link is not ready and should be examined.
Caution! Please verify the sign above the port to ensure using the other ports. Connecting to wrong ports might damage the transceiver or the other ports. When connecting other devices through a fiber cable to the switch, the output power of the fiber cable must not exceed the maximum received power of the corresponding modules. Otherwise, it will damage the switch. Do not stare at the fiber bore when the switch is in operation. That may hurt your eyes.
2.3.5 Power Supply Connection
DG-GS4526P use 220V AC power. Please read the power input specification for the detailed information.
Power supply connection procedure is described as below:
Fig 2-4 Attaching power cable to DG-GS4526P
17
Page 18
DG-GS4526P Installation Guide
1. Insert one end of the power cable provided in the accessory kit into the power source socket (with overload and leakage protection), and the other end to the power socket in the back panel of the switch.
2. Check the power status indicator in the front panel of the switch. The corresponding power indicator should light. DG-GS4526P are self-adjustable for the input voltage. As soon as the input voltage is in the range printed on the switch surface, the switch can operate correctly.
3. When the switch is powered on, it executes self-test procedure and startups.
Caution! The input voltage must be within the required range, otherwise the switch can be damaged or malfunction. Do not open the switch shell without permission. It can cause physical injury.
18