DIGI-SENSE DIGI-SENSE WD-20250-57 Manual

THE STANDARD IN PRECISION MEASUREMENT
User Manual
Visit us at www.TestEquipmentDepot.com
Autoranging Clamp Meters
with NIST-Traceable Calibration
Models 20250-57 (1000 A AC), 20250-58 (1000 A AC/DC, True RMS)
Phone 781-665-1400 Toll Free 1-800-517-8431
1065DGMAN_20250-57,-58 DS Clamp Meter Man.indd 1 8/8/2017 1:06:47 PM
Introduction
The Digi-Sense Autoranging Clamp Meters (1000 A AC Model 20250-57; 1000 A AC/DC True RMS Model 20250-58) offer all the basic features needed for measurement. The double-molded plastic housing and jaw are designed for use in tight places. A large backlit display provides easy-to­read measurements. The instruments are fully tested and calibrated to NIST-traceable standards. Careful use of the meter will provide years of reliable service.
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present
Double insulation
1065DGMAN_20250-57,-58 DS Clamp Meter Man.indd 2 8/8/2017 1:06:48 PM
2
SAFETY NOTES
• Do not exceed the maximum allowable input range of any
function.
• Do not apply voltage to meter when resistance function is
selected.
• Set the function switch OFF when the meter is not in use.
WARNINGS
• Set rotary function switch to the appropriate position
before measuring.
• When measuring volts, do not switch to current/resistance
modes.
• When changing ranges using the rotary function switch,
always disconnect the test leads from the circuit under test.
• Do not exceed the maximum rated input limits:
Input Limits
Function
Maximum Input,
Model 20250-57
Maximum Input,
Model 20250-58
A 1000 A AC 1000 A AC/DC V 600 V AC/DC 600 V AC/DC
Frequency, Duty
cycle, Resistance,
Diode, Continuity,
250 V AC/DC 250 V AC/DC
Capacitance Test
1065DGMAN_20250-57,-58 DS Clamp Meter Man.indd 3 8/8/2017 1:06:48 PM
Temperature (°C/°F) 60 V DC, 24 V AC
3
CAUTIONS
• Improper use of this meter can cause damage, shock,
injury or death. Read and understand this user manual before operating the meter.
• Always remove the test leads before replacing the battery.
• Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use.
• Use great care when making measurements if the voltages are greater than 25 VAC rms or 35 VDC. These voltages are considered a shock hazard.
• Remove the battery if the meter is to be stored for long
periods.
• Always discharge capacitors and remove power from the device under test before performing Diode, Resistance, or Continuity tests.
• Voltage checks on electrical outlets can be difcult and
misleading because of the uncertainty of connection to
the recessed electrical contacts. Other means should be
used to ensure that the terminals are not "live".
• If the equipment is used in a manner not specied by the manufacturer, the protection provided by the equipment
may be impaired.
1065DGMAN_20250-57,-58 DS Clamp Meter Man.indd 4 8/8/2017 1:06:48 PM
4
Unpacking
Check individual parts against the list of items below. If anything is missing or damaged, please contact your instrument supplier immediately.
1. Meter
2. Test leads
3. Temperature probe (model 20250-58 only)
4. Carrying case
5. 9 V battery
6. User manual
7. NIST-traceable calibration report with data
Key Features
1. Durable double-molded housing
3
2. 1
16" (30 mm) jaw opening
3. CAT III 600 V safety rating
4. Electronic overload protection
5. Autoranging with auto power-off
1065DGMAN_20250-57,-58 DS Clamp Meter Man.indd 5 8/8/2017 1:06:48 PM
5
Meter Description (Model 20250-57)
60A
600A
A
1
2
9
4
3
6
5
8
7
1. Current clamp
2. Clamp trigger
3. Data HOLD and Backlight button
4. MODE select button
5. RANGE select button
6. LCD
7. COM input jack
8. Rotary function switch
9. Hz% Hold button
10. Max/Min button
11. V Ω
12. Battery compartment (on rear)
•))) Hz jack
1065DGMAN_20250-57,-58 DS Clamp Meter Man.indd 6 8/8/2017 1:06:49 PM
Meter Description (Model 20250-58)
1. Current clamp
2. Clamp trigger
3. Data HOLD and Backlight button
4. MODE select button
5. RANGE select button
6. LCD
7. COM input jack
8. Rotary function switch
9. DC ZERO button
10. Max/Min button
11. V Ω
•))) CAP Hz Temp jack
12. Battery compartment (on rear)
6
6
A
600A
60A
A
A


A 
