Introduction
The Digi-Sense Heavy-Duty Autoranging Digital Multimeter with Bluetooth
®
Connectivity (model 20250-64) allows you to transmit data directly to your Android™ or iOS® device using our free D/S Meter app. Now you can view data at a safe distance from potentially hazardous parameters or even use your smart device as a real-time secondary display for checking measure­ments, eliminating the need to write down readings on paper. The results are automatically stored in the app with a date-and-time stamp and can be saved as a CSV file and emailed for future reference, manipulation, or analysis to help determine trends and conditions over a long period of time. You can also use the app to attach photos and notes to the records creating a clear reference point for your work—ideal for record keeping at large sites.
Setup is simple. Download the free D/S Meter app to your Android or iOS device. Place the multimeter in Bluetooth mode and open the app on your smart device. The meter will be sensed by your device and be listed as an available source that you can select. Once selected, the data sensed by the meter is displayed on your device and some of the instrument functions can be accessed. A full description of its operation is available for download in the app.
The Heavy-Duty Digital Autoranging Multimeter measures AC/DC voltage, AC/DC current, resistance, frequency (electrical & electronic), capacitance, diode test, and continuity. The meter also offers True RMS for more accurate current readings, temperature measurement with a type K thermocouple, and analog bar graph for viewing trends. Rugged IP67-rated waterproof design withstands heavy-duty use. This instrument is fully tested and calibrated to NIST-traceable standards for reliable measurements right out of the box, saving you time and money. Proper use and care will provide many years of reliable service.
2
1065DGMAN_20250-64_Rev1.indd 2 07/02/2019 11:23:02 AM
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for more information.
This WARNING symbol indicates a potentially hazardous
WARNING
CAUTION
situation, which if not avoided, could result in death or serious injury.
CAUTION symbol indicates a potentially hazardous situa­tion, which if not avoided, may result in product damage.
This symbol advises the user that the terminal(s) so
MAX
marked must not be connected to a circuit point at which the voltage with respect to earth ground exceeds (in this case)1000VAC or 1000VDC.
This symbol adjacent to one or more terminals identifies them as being associated with ranges that may, in normal use, be subjected to particularly hazardous voltages. For maximum safety, the meter and its test leads should not be handled when these terminals are energized.
This symbol indicates that a device is protected through­out by double insulation or reinforced insulation.
1065DGMAN_20250-64_Rev1.indd 3 07/02/2019 11:23:03 AM
3
Safety Instructions
This meter has been designed for safe use but must be operated with caution. The rules listed below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the
specified maximum:
Input Protection Limits
Function Maximum Input V DC or V AC 1000 VDC/1000 VAC RMS mA AC/DC 500 mA 1000 V fast acting fuse
A AC/DC
Frequency, Resistance, CAP, Diode Test, Continuity, Temperature, Duty Cycle
Surge Protection: 8 kV peak per IEC 61010
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the “COM” input
jack exceeds 1000V above earth ground.
4. NEVER connect the meter leads across a voltage source while
the function switch is in the current, resistance, CAP, or diode mode. Doing so can damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and
disconnect the power when making resistance or diode tests.
6. ALWAYS turn off the power and disconnect the test leads
before opening the covers to replace the fuse or batteries.
7. NEVER operate the meter unless the back cover and the battery
and fuse covers are in place and fastened securely.
8. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
10 A 1000 V fast-acting fuse (10A for 30 seconds max every 15 minutes)
250 VDC/AC RMS
4
1065DGMAN_20250-64_Rev1.indd 4 07/02/2019 11:23:03 AM
Unpacking
Check individual parts against the list of items below. If anything is missing or damaged, please contact your instrument supplier immediately.
1. Meter
2. Test leads
3. One type K temperature probe
4. One 9 V battery
5. Carrying case
6. User manual
7. NIST-traceable calibration report with data
Key Features
• Bluetooth interface
• User-friendly mobile app
• 4000 display count
• True RMS readings
• Electronic overload protection
• Autoranging with auto power-off
• Data Hold function
• Rugged IP67-rated double-molded housing
1065DGMAN_20250-64_Rev1.indd 5 07/02/2019 11:23:03 AM
5
Meter Description
1. 4000 counts LCD
1
2. MAX/MIN button
3. RANGE button
4. MODE button
3
4
5. Rotary function switch
6. mA, µA and 10 A
input jacks
7. COM input jack
8. Positive input jack
9. Hz and % button
2
5
6
10. HOLD and Backlight button
11. RELATIVE and Bluetooth button
Note: Tilt stand and battery compartment are on rear of unit.
9
10
11
8
7
6
1065DGMAN_20250-64_Rev1.indd 6 07/02/2019 11:23:03 AM
Symbols and Annunciators
µ m A Amps k M Ohms Hz Hertz (frequency) V Volts
1065DGMAN_20250-64_Rev1.indd 7 07/02/2019 11:23:03 AM
)))
Auto power-off Continuity Diode test Battery status
–6
micro (10 milli (10
)
–3
)
kilo (103)
6
mega (10
)
% Percent (duty ratio) REL Relative AC Alternating current AUTO Autoranging DC Direct current HOLD Display hold MAX Maximum MIN Minimum hFE Reserved
Bluetooth
°F Degrees Fahrenheit °C Degrees Centigrade
7
Setup and Operation
WARNING: Risk of electrocution. High-voltage circuits, both
AC and DC, are very dangerous and should be measured with great care.
1. ALWAYS turn the rotary function switch to the OFF position when the meter is not in use.
2. If “OL” appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range.
DC Voltage Measurements
CAUTION: Do not measure DC voltages if a motor on the circuit
is being switched ON or OFF. Large voltage surges may occur that can damage the meter.
1. Set the rotary function switch to the green VDC position.
2. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack.
3. Touch the black test probe tip to the negative side of the circuit and touch the red test probe tip to the positive side of the circuit.
4. Read the voltage in the display.
8
1065DGMAN_20250-64_Rev1.indd 8 07/02/2019 11:23:03 AM
AC Voltage (Frequency, Duty Cycle) Measurements
WARNING: Risk of Electrocution. The probe tips may not be
long enough to contact the live par ts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets. As a result, the reading may show 0 volts when the outlet actually has voltage on it. Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present.
CAUTION: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter.
1. Set the rotary function switch to the green VAC/Hz/% position.
2. Insert the black test lead banana plug into the negative
COM jack and the red test lead banana plug into the positive V jack.
3. Touch the black test probe tip to the neutral side of the circuit and touch the red test probe tip to the “hot” side of the circuit.
4. Read the voltage in the display.
5. Press the Hz/% button to indicate “Hz”.
6. Read the frequency in the display.
7. Press the Hz/% button again to indicate “%”.
8. Read the percent of duty cycle in the display.
1065DGMAN_20250-64_Rev1.indd 9 07/02/2019 11:23:03 AM
9
DC Current Measurements
CAUTION: Do not make 10 A current measurements for longer
than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test.
1. Insert the black test lead banana plug into the negative
COM jack.
2. For current measurements up to 4000 µA DC, set the rotary
function switch to the yellow µA position and insert the red test lead banana plug into the µA/mA jack.
3. For current measurements up to 400 mA DC, set the rotary
function switch to the yellow mA position and insert the red test lead banana plug into the µA/mA jack.
4. For current measurements up to 10 A DC, set the rotary
function switch to the yellow 10A/Hz/% position and insert the red test lead banana plug into the 10A jack.
5. Press MODE button to indicate “DC” on the display.
6. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.
7. Touch the black test probe tip to the negative side of the circuit and touch the red test probe tip to the positive side of the circuit.
8. Apply power to the circuit.
9. Read the current in the display.
10
1065DGMAN_20250-64_Rev1.indd 10 07/02/2019 11:23:03 AM
AC Current (Frequency, Duty Cycle) Measurements
CAUTION: Do not make 10 A current measurements for longer
than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test.
1. Insert the black test lead banana plug into the
negative COM jack.
2. For current measurements up to 4000 µA AC, set the
rotary function switch to the yellow µA position and insert the red test lead banana plug into the µA/mA jack.
3. For current measurements up to 400 mA AC, set the rotary
function switch to the yellow mA position and insert the red test lead banana plug into the µA/mA jack.
4. For current measurements up to 10 A AC, set the rotary
function switch to the yellow 10A/Hz/% position and insert the red test lead banana plug into the 10A jack.
5. Press the MODE button to indicate “AC” on the display.
6. Remove power from the circuit under test, then open at the point where you wish to measure current.
7. Touch the black test probe tip to the neutral side of the circuit and touch the red test probe tip to the “hot” side of the circuit.
8. Apply power to the circuit.
9. Read the current in the display.
10. Press the Hz/% button to indicate “Hz”.
11. Read the frequency in the display.
12. Press the Hz/% button again to indicate “%”.
13. Read the percent of duty cycle in the display.
14. Press the Hz/% button to return to current measurement.
1065DGMAN_20250-64_Rev1.indd 11 07/02/2019 11:23:03 AM
11
Resistance Measurements
WARNING: To avoid electric shock, disconnect power to the
unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords.
1. Set the rotary function switch to the green
2. Insert the black test lead banana plug into the negative COM
jack and the red test lead banana plug into the positive jack.
3. Press the MODE button to indicate “” on the display.
4. Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading.
5. Read the resistance in the display.
)))
position.
Continuity Check
WARNING: To avoid electric shock, never measure continuity on
circuits or wires that have voltage on them.
1. Set the rotary function switch to the green
2. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive jack.
3. Press the MODE button to indicate “ the display.
4. Touch the test probe tips to the circuit or wire you wish to check.
5. If the resistance is less than approximately 35 , the audible signal will sound. If the circuit is open, the display will indicate “OL”.
)))
” and “” on
)))
position.
12
1065DGMAN_20250-64_Rev1.indd 12 07/02/2019 11:23:03 AM
Diode Test
1. Set the rotary function switch to the green
2. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack.
3. Press the MODE button to indicate “
” and “V” on
the display.
4. Touch the test probes to the diode under test. Forward volt­age will typically indicate 0.400 to 0.700 V. Reverse voltage will indicate “OL”. Shorted devices will indicate near 0 V and an open device will indicate “OL” in both polarities.
)))
position.
Frequency/Duty Cycle Measurements (Electronic)
1. Set rotary function switch to the green Hz/% position.
2. Press the Hz/% button to indicate “Hz” on the display.
3. Insert the black test lead banana plug into the negative
COM jack and the red test lead banana plug into the positive Hz jack.
4. Touch the test probes to the circuit under test.
5. Read the frequency on the display.
6. Press the Hz/% button again to indicate “%” on the display.
7. Read the percent of duty cycle on the display.
1065DGMAN_20250-64_Rev1.indd 13 07/02/2019 11:23:03 AM
13
Temperature Measurements
1. Set the rotary function switch to the green Temp position.
2. Insert the temperature probe into the input jacks, making sure to observe the correct polarity.
3. Press the MODE button to indicate °F or °C.
4. Touch the temperature probe head to the part whose tempera­ture you wish to measure. Keep the probe touching the part under test until the reading stabilizes (about 30 seconds).
5. Read the temperature in the display.
Note: Temperature probe is fitted with a type K mini connector. Mini connector to banana connector adapter is supplied for connection to the input banana jacks.
Autoranging/Manual Range Selection
When the meter is first turned on, it automatically goes into autoranging mode. This automatically selects the best range for the measurements being made and is generally the best mode for most measurements. For measurement situations requiring that a range be manually selected, perform the following:
1. Press the RANGE key. The “AUTO” display indicator will turn off.
2. Press the RANGE key to step through the available ranges until you select the range you want.
3. To exit the manual ranging mode and return to autoranging mode, press and hold the RANGE key for 2 seconds.
Note: Manual ranging does not apply for the Frequency functions.
MAX/MIN Function
Note: When using the MAX/MIN function in autoranging mode,
the meter will “lock” into the range that is displayed on the LCD when MAX/MIN is activated. If a MAX/Min reading exceeds that range, an “OL” will be displayed. Select the desired range BEFORE entering MAX/MIN mode.
14
1065DGMAN_20250-64_Rev1.indd 14 07/02/2019 11:23:03 AM
1. Press the MAX/MIN key to activate the MAX/MIN recording mode. The display icon “MAX” will appear. The meter will display and hold the maximum reading and will update only when a new “MAX” occurs.
2. Press the MAX/MIN key again and the display icon “MIN” will appear. The meter will display and hold the minimum reading and will update only when a new “MIN” occurs.
3. To exit the MAX/MIN mode, press and hold the MAX/MIN key for 2 seconds.
Switching on Bluetooth® and Sending Measurements
Press and hold REL button until the Bluetooth symbol appears in the display. Then you can use our D/S Meter App installed on your phone to connect with the instrument.
Switching off Bluetooth
Press and hold REL button to switch off Bluetooth. The Bluetooth connectivity switches off as soon as the meter is switched off.
Relative Mode
The relative measurement feature allows you to make measure­ments relative to a stored reference value. A reference voltage, current, etc. can be stored and measurements made in compari­son to that value. The displayed value is the difference between the reference value and the measured value.
1. Perform the measurement as described in this manual.
2. Press the REL button to store the reading in the display and the “REL” indicator will appear on the display.
3. The display will now indicate the difference between the stored value and the measured value.
4. Press the REL button to exit the relative mode.
Note: The Relative function does not operate in the Frequency function.
1065DGMAN_20250-64_Rev1.indd 15 07/02/2019 11:23:03 AM
15
Display Backlight
Press and hold the HOLD key for >1 second to turn on or off the display backlight function. The backlight will automatically turn off after 5 minutes.
Hold Function
The Hold function freezes the reading in the display. Press the
HOLD key momentarily to activate or to exit the Hold function.
Automatic Power-Off
In order to conserve battery life, the meter will automatically turn off after approximately 15 minutes of nonuse. To disable the auto power-off feature, hold down the MODE button and turn the meter on.
Low-Battery Indication
The icon will appear in the lower left corner of the display when the battery voltage becomes low. Replace the battery when this appears.
16
1065DGMAN_20250-64_Rev1.indd 16 07/02/2019 11:23:03 AM
Specifications
Function Range Resolution Accuracy
±(0.8% reading + 8 digits)
±(1% reading + 8 digits)
±(0.8% reading + 8 digits) 50 Hz to 400 Hz
±(1.5% reading + 10 digits)
±(1.5% reading + 10 digits)
±(1.0% reading + 3 digits)
±(1.5% reading + 3 digits)
50 Hz to 400 Hz
±(3.0% reading + 5 digits)
±(3.0% reading + 5 digits)
DC Voltage
AC Voltage (400 mV is not autoranging)
DC Current
AC Current
400 mV 0.1 mV 4 V 0.001 V
40 V 0.01 V 400 V 0.1 V
1000 V 1 V
400 mV* 0.1 mV 4 V 0.001 V 40 V 0.01 V 400 V 0.1 V
1000 V 1 V
All AC voltage ranges are specified from 5% of range to 100% of range
400 µA 0.1 µA 4000 µA 1 µA 40 mA 0.01 mA 400 mA 0.1 mA 4 A 0.001 A 10 A 0.01 A (10 A: 30 sec max with reduced accuracy)
400 µA 0.1 µA 4000 µA 1 µA 40 mA 0.01 mA 400 mA 0.1 mA 4 A 0.001 A 10 A 0.01 A (10 A: 30 sec max with reduced accuracy)
All AC current ranges are specified from 5% of range to 100% of range
Note: Accuracy is stated at 65 to 83°F (18 to 28°C) and <75% RH.
1065DGMAN_20250-64_Rev1.indd 17 07/02/2019 11:23:03 AM
17
Specifications (cont.)
Function Range Resolution Accuracy
Temperature (type K)
Resistance
Capacitance
Frequency (electronic)
Note: Accuracy is stated at 65 to 83°F (18 to 28°C) and <75% RH.
–50 to 1382°F –45 to 750°C 400 0.1 4 k 0.001 k 40 k 0.01 k 400 k 0.1 k 4 M 0.001 M
40 M 0.01 M
40 nF 0.01 nF 400 nF 0.1 nF
4 µF 0.001 µF 40 µF 0.01 µF 400 µF 0.1 µF
4000 µF 1 µF
9.999 Hz 0.001 Hz
99.99 Hz 0.01 Hz
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
999.9 kHz 0.1 kHz
9.999 MHz 0.001 MHz Sensitivity: 0.8 V rms min @ 20 to 80% duty cycle
and<100 kHz; 5 Vrms min @ 20 to 80% duty cycle and >100 kHz.
0.1°F
0.1°C
±(3.0% reading + 9°F/5°C digits) (probe accuracy not included)
±(1.2% reading + 4 digits)
±(2.0% reading + 20 digits)
±(5.0% reading + 10 digits)
±(3.0% reading + 5 digits)
±(5.0% reading + 10 digits)
±(1.5% reading + 5 digits)
18
1065DGMAN_20250-64_Rev1.indd 18 07/02/2019 11:23:03 AM
Function Range Resolution Accuracy
Frequency (electrical)
Duty Cycle
10.00 to 400 Hz 0.01 Hz ±(0.5% reading)
Sensitivity: 15V rms
0.1 to 99.9% 0.1%
±(1.2% reading + 2 digits)
Pulse width: 100 µs to 100 ms, Frequency: 5 Hz to 150 kHz
Note: Accuracy specifications consist of two elements: (% reading) – This is the accuracy of the measurement circuit. (+ digits) – This is the accuracy of the analog to digital converter.
1065DGMAN_20250-64_Rev1.indd 19 07/02/2019 11:23:03 AM
19
General Specifications
Bluetooth version 4.0 Diode test
Continuity check Input impedance >10 M VDC and >10 M VAC
AC response True RMS ACV bandwidth 50 to 400 Hz
Crest factor Display 4000 counts LCD, backlighting and bar graph
Polarity Measurement rate 2 times per second, nominal
Overrange indication ‘OL’ display Low battery indication Auto power-off 15 minutes with disable feature
Battery One (1) 9 V (NEDA 1604) battery Enclosure Double molded, waterproof Shock (drop) test 6.5 ft (2 m) Operating temp. 41 to 104°F (5 to 40°C) Storage temperature –4 to 140°F (–20 to 60°C)
Operating humidity Storage humidity <80%
Operating altitude 7000 ft (2000 m) maximum Dimensions Weight 12.1 oz (342 g) including holster
Safety
Test current of 0.9 mA maximum, open circuit voltage 2.8 V DC typical
Audible signal will sound if resistance is <35 (approx.); test current <0.35 Ma
3 at full scale up to 500 V, decreasing linearly to 1.5 at 1000 V
Automatic. No indication for positive; minus (–) sign for negative.
is displayed
Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C)
5
7
32" x 37⁄32" x 25⁄16" (18.2 x 8.2 x 5.9 cm)
including holster
This meter is intended for origin of installation use and protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2 Edition (2001) to Category IV 600V and Category III 1000V; Pollution Degree
2. The meter also meets UL 61010-1, 2nd Edition (2004), CAN/CSA C22.2 No. 61010-1 2nd Edition (2004), and UL 61010B-2-031, 1st Edition (2003)
20
1065DGMAN_20250-64_Rev1.indd 20 07/02/2019 11:23:03 AM
Maintenance, Recalibration, and Repair
WARNING: To avoid electric shock, disconnect the test leads
from any source of voltage before removing the back cover or the battery or fuse covers.
WARNING: To avoid electric shock, do not operate your meter until the battery and fuse covers are in place and fastened securely.
This meter is designed to provide years of dependable service, if the following care instructions are performed:
• Keep the meter dry. If it gets wet, wipe it off.
• Use and store the meter in normal temperatures. Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts.
• Handle the meter gently and carefully. Dropping it can damage the electronic parts or the case.
• Keep the meter clean. Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents, or detergents.
• Use only fresh batteries of the recommended size and type. Remove old or weak batteries so they do not leak and damage the unit.
• If the meter is to be stored for a long period of time, remove the batteries to prevent damage to the unit.
1065DGMAN_20250-64_Rev1.indd 21 07/02/2019 11:23:03 AM
21
Battery Installation
WARNING: To avoid electric shock, disconnect the test
leads from any source of voltage before removing the battery cover.
1. Turn power off and disconnect the test leads from the meter.
2. Open the rear battery cover by removing the screw using a Phillips head screwdriver.
3. Insert the battery into battery holder, observing the cor­rect polarity.
4. Put the battery cover back in place. Secure with the screws.
WARNING: To avoid electric shock, do not operate the meter until the battery cover is in place and fastened securely.
Note: If your meter does not work properly, check the fuses and batteries to make sure that they are still good and that they are properly inserted.
22
1065DGMAN_20250-64_Rev1.indd 22 07/02/2019 11:23:03 AM
Replacing the Fuses
WARNING: To avoid electric shock, disconnect the test
leads from any source of voltage before removing the fuse cover.
1. Disconnect the test leads from the meter.
2. Remove the battery cover.
3. Gently remove the old fuse and install the new fuse into the holder.
4. Always use a fuse of the proper size and value (0.5A/1000V fast blow for the 400 mA range, 10A/1000V fast blow for the 10 A range).
5. Replace and secure the rear cover, battery and battery cover.
WARNING: To avoid electric shock, do not operate your meter until the fuse cover is in place and fastened securely.
1065DGMAN_20250-64_Rev1.indd 23 07/02/2019 11:23:04 AM
23
It is recommended that Digi-Sense products are calibrated annually
however, your quality system or regulatory body may require more frequent calibrations. To schedule your recalibration, please contact InnoCal, an ISO 17025 calibration laboratory accredited by A2LA.
to ensure proper function and accurate measurements;
Phone: 1-866-INNOCAL (1-866-466-6225) Fax: 1-847-327-2993 E-mail: sales@innocalsolutions.com Web: InnoCalSolutions.com
For Product and Ordering Information, Contact:
Toll-Free: 1-800-323-4340 Phone: 1-847-549-7600 Fax: 1-847-247-2929 ColeParmer.com/Digi-Sense
1065DGMAN_20250-64_Rev1
1065DGMAN_20250-64_Rev1.indd 24 07/02/2019 11:23:04 AM
Manual Part No. 00102-00
Loading...