Two points' calibration is necessary for
maintaining the accuracy of the meter.
D. ALARM CHECK MODE
An environment monitoring system
is implanted in the meter for special
uses. A monitoring range can be set
up earlier,the user will be warned for
any out-of-range reading.This Mode
provides you to check the alarm
settings to see if they are under your
requirement.
E. ALARM SETTING MODE
Set, adjust and cancel the alarm
settings.
F. RS232 OUTPUT
To link to the computer gets records.
G. SLEEP MODE OPTION
We have a Non-sleep mode and a 20
minutes sleep mode. You can switch
easily between two.
H. MN/MX MODE
Maximum and Minimum monitoring.
You can find out the minimum and
maximum values of previous recording
simply by pressing MN/MX key
sequentially. The screen will display
Fig. 1 & Fig. 2. Press it again to go
back to normal mode or the meter will
return to normal mode in 10 seconds.
This is the normal operation mode for
measuring relative humidity and
temperature in the default unit.
When the power is first on, the full LCD
display will appear as Fig. 4.
Full display will appear for 1 second, then
readings for humidity and temperature,
(Big characters is humidity and small
characters is temperature) will display.
Fig. 5
2. Gently open the cover of HR33 ref.salt.
Insert the probe into the container from
the top until you reach the end.
( Warning: Be very careful and slow
while inserting the probe or pulling it
out. Any rough movement may damage
the Humidity Reference Bottle).
3. Press RESET one time, the 32.X%RH
and MIN will appear on LCD (Fig. 8).
The low humidity calibration will be in
process automatically. This process will
be completed in about 40 minutes with
SA, MAX and MIN shown by LCD display
(Fig. 9). (Warning: Do not touch any
keys before the process is completed.)
FIG 8
%RH
MIN
FIG 9
MAX
NOTE:
The 40 minutes is suggested for a stable
temperature environment. If the
temperature variation is above 0.5 F in
5 minutes, the calibration time will be
extended automatically. It is recommended
MIN
o
to isolate or insulate the standard Humidity
Reference if the environment temperature
is not stable.
4. After 40 minutes, low humidity
calibration is completed. Now you can
press OFF to end the process or
continue to process high humidity
calibration. To do this, insert the probe
into HR75 and press the NX/td key, the
LCD will display 75.X and MAX (Fig. 10)
which indicates the high humidity
calibration will soon be in process
automatically.
FIG 10
%RH
MAX
NOTE:
A convenient look-up table has been built
in to aid calibration.
HR 33 MgCl
ooooo
TEMP
RH%
If different temperatures, say 25 C, the
RH of MgCl is 32.78 and in 30 C, the RH
is 32.44.
The same reference says 30 C , the RH
of Nacl is 75.09 RH% humidity and in
o
35 C , the RH is 74.87% .(See the table)
15 C 20 C 25 C 30 C 35 C
33.30 33.07 32.78 32.44 32.05
o
o
o
HR75NaCl
ooooo
TEMP
RH%
The relations are recorded in the look-up
table.
Once the calibration mode in ON,
the meter will search the right humidity
value according to the current temperature to get more accurate calibration.
For Relative Humidity calibration , to
ensure the longer life of the salt bottle
.Keep the bottle in the bag when not in
use and seal the bag tightly .
a. If you are sure of that temperature is
stable and humidity is in equilibrium.
You can reduce the time of the above
process by pressing the PRG key. A
SA will be shown on the screen. Be
very careful with this. If the time
interval is not long enough for unit to
catch the right humidity, whole
measurement later will not be valid.
b. To skip the on-going calibration
process, press RESET. If you are not
sure of the on-going process, press
OFF.
c. After humidity calibration is done, if the
measuring mode displays E2 instead
of the RH and temperature readings,
this means something is wrong.
Please refer to error messages section.
C. HIGH HUMIDITY CALIBRATION MODE
1. There are two ways to enter the high
humidity calibration mode:
a. Turn off the meter. Plug probe into
HR75, then press ON & PRG at the
same time. Hold till CAL is displayed
on screen. Release ON & PRG and
press RESET twice, the LCD will show
75.X% and MAX (Fig. 10). This
indicates that the high humidity
calibration is in automatic process.
b. When the automatic process for low
humidity calibration is completed, the
LCD displays SA, MAX and MIN
(Fig. 9). Insert the probe into HR75,
then press NX/td. The LCD will show
75.X% and MAX (Fig. 10). This
indicates that the high humidity
calibration is in automatic process.
2. Once the meter starts the automatic
calibration process, do not touch any
key until the meter switches to
measuring mode.
3. To reduce the time for calibration
process, press PRG. Be cautious
with this, refer to NOTE a. of the Low
Humidity Calibration .
4. To skip the on-going calibration
process, press RESET. Turn off the
meter if you are not sure of the on going process.
D. ALARM CHECK MODE
1. In measuring mode, press PRG key.
The LCD will display the indicators
LOTEMP, HITEMP, LO%RH, HI%RH
plus XX.Xwith LOTEMP flashing first
(Fig. 11).
2. XX.X is the numeric value previously set
for the flashing indicator. If --- instead
of a reading is displayed, it indicates
that there is no alarm setting for this
option.
3. Press NX/td key to check the value of
HITEMP(HITEMP is flashing now), and
press NX/td again to check LO%RH ,
and so on.
4. In monitoring range, LOTEMP indicates
the warning point for low temperature.
HITEMP indicates the warning point
for high temperature. LO%RH indicates
the warning point for low humidity.
HI%RH indicates the warning point for
high humidity.
5. Press RESET key to switch the mode
back to the normal operation mode, i.e.
The measuring mode.
LOTEMP
FIG 11
HITEMP
LO%RH
HI%RH
o
F
E. ALARM SETTING MODE
For example, if a user needs to be
alarmed when the temperature reading
goes below 58 F or above 100 and
o
o
F
when the relative humidity reading goes
below 56% or above75%, the user
should set LOTEMP, HITEMP, LO%RH,
o
and HI%RH as follows: LOTEMP=58;
o
HITEMP=100 LO%RH=56%; HI%RH
F
F
=75%; Once the meter readings go out
of the range, the alarm will start to beep.
The LCD will also display which indicator
is alarmed. Steps to set up the alarm
are as follows
1. Power on the meter. When the %RH
reading and the temperature reading
are displayed (Fig. 5). Press PRG to
switch from the measuring mode to
alarm check mode (Fig.11 w/ LOTEMP
flashing).
o
2. Press PRG key, it will display XX as
F
Fig. 12 with " X " flashing. LOTEMP
means we are in low temperature alarm
setting screen.
3. Press NX/td key to change the digital
flash. Press MN/MX and change the
o
number until it displays 58 as Fig. 13.
F
LOTEMP
FIG 12
o
F
LOTEMP
FIG 13
o
F
4. Press PRG key until it displays SA,
release it, the display will show as Fig.
14 with LOTEMP flashing.
5. Press the NX/td key until HITEMP flash.
6. Press the PRG key. Repeat step 2, 3.
Change the number to 45 C. Press
o
PRG to save the setting. It will show
as Fig. 15 with HITEMP flashing.
75.1% and 74.9, it will continue
beeping and display as shown in Fig.
20.LOTEMP, it means temperature is
below our setting. HI%RH, it means
the humidity is above our setting.
14. Cancel setting: when in step 4
(or step 9), if you press RESET and
hold it for 2 seconds and hear beeps.
This means the setting has been
cancelled and it will display as Fig. 21.
You can also cancel the whole setting by
the following: Turn off the meter. Press
RESET and ON at the same time the
meter will display OAL one second as
shown in Fig. 22 with two beeps, then
turns to the normal mode. Thus LOTEMP,
HITEMP , LO%RH,and HI%RH settings
will be cancelled at one operation.
LOTEMP
FIG 21
HITEMP
LO%RH
HI%RH
o
F
FIG 22
F. RS232 OUTPUT(Optional)
Plug the earphone jack of the cable
VZRS232M into RS232 socket on the
meter and connect 9-pin D-sub to the
computer's available COM port. Press
ON key to start measurement. The
VZRS232M is optional accessory.
Contact with the store for more cable
& software purchasing information.
G. SLEEP MODE OPTION
1. In default, if there is no key pressed
in 20 minutes, the meter will go off
automatically. A warning continuous
beep will sound shortly before 20
minutes, press any key can restart the
20 minutes counts.
2. You can switch the meter to non sleep mode by first turn the meter off,
then push and hold MN/MX and ON at
the same time until nSL is displayed as
shown in Fig. 23. Release the key and
you are in Non-Sleep mode.
oo
H. C/ F SWITCH MODE
You can change the C/ F display
oo
anytime you want by pressing the
oo
C/ F key during operation. You can
also change the default display by the
following:
For example, if the meter default to F,
o
while turning off the meter, press PRG
& ON at the same time until CAL is
shown in one second, then release the
keys. F will display on the right bottom
o
corner of the LCD. See Fig. 24
Press MN/MX to change F to C ,then
o
o
press PRG until it displays SA in one
second and XX.X%RH and MIN will
appear on the left corner , turn off the
meter. Now when you turn on the meter,
it will default to C
Authorization must be obtained from the
supplier before returning items for any
reason .
When requiring a RA (Return
Authorization) , please include data
regarding the defective reason, the
meters are to be returned along with
good packing to prevent any damage in
shipment and insured against possible
damage or loss .
WARRANTY
The meter is warranted to be free from
defects in material and workmanship for
a period of one years from the date of
purchase.
This warranty covers normal operation
and does not cover batteries,misuse,
abuse, alteration, tampering, neglect,
improper maintenance, or damage
resulting from leaking batteries.
Proof of purchase is required for
warranty repairs.