The Digi-Sense Temperature/RH Touch-Screen Monitor (Model 20250-40)
measures and logs temperature, relative humidity, and dew point readings in
real time and displays them in digital and graphic forms. Intuitive touch-screen
menu allows you to program data collection parameters and adjust the graphic
display for the best presentation of the data. Software is pre-installed so no
downloading is required; just turn the instrument on and it is ready to run.
The 8 GB of memory means you have nearly unlimited data collection capability
which is easily downloaded to a computer in CSV format for simple integration
with standard applications. The instrument is fully tested and calibrated to
NIST-traceable standards. Careful use of this unit will provide years of reliable
service.
Unpacking
Check individual parts against the list of items below. If anything is missing or
damaged, please contact your instrument supplier immediately.
1. "Live" indicates that the instrument is in Live mode, default of starting up is
Live Mode with sampling rate of one measurement per minute. There are three
modes: Live, Recording and History.
Live: Default mode, the instrument will start to record according
to a sampling rate of 1 per minute.
Recording: Set by the user according to the sampling rate, time,
and data points.
History: Pulls up historical data recorded.
2. The right side indicates the current data and time of sampling points.
Digital Area
1. Temperature indicates the temperature value in Fahrenheit or Celsius.
2. Humidity indicates humidity value in % RH.
3. Dew Point indicates dew point value in Fahrenheit or Celsius.
4. Max/Min indicates the maximum or minimum value that has been recorded.
Recording Setup: Allows you to set sampling rate, start time, and data points.
1. Sample Rate: Set sampling rate.
2. Start Time: Set recording starting time (Note: The default time is the current
date and time in the system; a start time can be set into the future and the
instrument will be automatically start recording at the future date and time)
3. Max Data Points: Select the number of sample points from 500, 1000, 5000,
10000, 20000, or MAX.
4. Click Save to save the setting parameters.
5. Click Cancel to return to main screen.
View Alarms: Lets you view recorded alarm values.
1. Sort by Date: View recorded alarms sorted by date.
2. Sort by Value: View recorded alarms sorted by temperature and humidity
alarm value.
• The instrument should be cleaned with a damp cloth and mild detergent when
necessary. Do not use solvents or abrasives.
• Store the instrument in an area with moderate temperature and humidity.
It is recommended that Digi-Sense products are calibrated annually to ensure
proper function and accurate measurements; however, your quality system or
regulatory body may require more frequent calibrations. To schedule your
recalibration, please contact InnoCal, an ISO 17025