Digi-Sense 20250-15 User Manual

User Manual
THE STANDARD IN PRECISION MEASUREMENT
Professional CFM/CMM Vane Thermoanemometer
with NIST-Traceable Calibration
2
Introduction
The Digi-Sense Professional CFM/CMM Vane Thermoanemometer (Model 20250-15) provides precision air velocity, airflow (volume), and temperature measurements. The large, easy-to-read backlit LCD includes primary and secondary displays plus numerous status indicators. The meter features 16 memory locations (8 for CFM and 8 for CMM) to store and recall commonly used area sizes. The instrument is fully tested and calibrated to NIST-traceable standards. Careful use of this meter will provide years of reliable service.
Unpacking
Check individual parts against the list of items below. If anything is missing or damaged, please contact your instrument supplier immediately.
1. Meter
2. Anemometer vane sensor on 3.9 ft (120 cm) cable
3. Hard carrying case
4. One 9 V battery
5. User manual
6. NIST-traceable calibration report with data
Meter Description
1. LCD
2. Vane sensor
3. Temperature buttons
4. Power On/Off button
5. Airflow/velocity buttons
6. AVG
7. Backlight
1
7
6
5
2
3
4
3
Keypad
POWER Press to turn the meter ON or OFF
MAX/MIN Used to record and store the highest, lowest and average air­flow or velocity readings. (LEFT) also serves as change deci­mal point button in AREA mode
UNITS Press to select the mode of operation. In FLOW mode, the meter displays air volume. In VELOCITY mode, the meter displays air speed. (UP) also serves as increase num­ber button in AREA mode.
AVG Used to Average multiple read- ings in FLOW or VELOCITY mode. Up to 20 readings can be averaged.
HOLD Press to freeze the displayed reading. Press again to unlock dis­play. This button also functions as the (RIGHT) scroll button in AREA mode.
AREA/ NEXT Press and hold to manually enter the area of a duct in CFM or CMM mode. In AREA mode, used to select memory locations 1 through 8.
Press to turn the backlight on/off
MAX/MIN (Temperature) Used to record and store the highest, lowest readings for air temperature.
HOLD (Temperature) Press to freeze the displayed temperature reading. Press again to unlock the display. Press and hold for 3 seconds to switch between °C and °F. Meter will beep twice to indicate change.
4
Display Layout
REC (top of LCD): indicates that min/ max temperature function is running
MAX (top of LCD): maximum hold function engaged for an air temperature measurement
MIN (top of LCD): minimum hold function engaged for an air temperature measurement
HOLD (top of LCD): data hold function engaged for an air temperature measurement
°C / °F: temperature units of measure
: Low-battery indicator
AREA (ft
2
, m2): units for area dimensions
VEL: indicates that meter is in air velocity mode
FLOW: indicates that meter is in airflow mode
CFM/CMM: airflow units of measure
m/s, ft/min, km/h, MPH, knots: air
velocity units of measure
X10, X100: multipliers for airflow readings
REC: indicates that min/max function is running (top for temp, bottom for air)
MAX (bottom of LCD): maximum hold function for an air velocity and airflow measurement
MIN (bottom of LCD): minimum hold function for an air velocity and airflow measurement
AVG: air averaging mode
HOLD (bottom of LCD): Data Hold for an
Air Velocity and Airflow function
Large LCD digits at bottom of display
for air velocity and airflow
Smaller LCD digits at top right of display
for probe temperature