DigiPos SD-303 User Manual

Page 1
1
Contents
Cha pter 1 Description
1.1 Notice ....................................................... 3
1.2 Introduction ........................................... 4
1.3 Codes Read ........................................... 4
1.4 Installation .............................................. 4
1.5 Pin Assignment ...................................... 6
Chapter 2 Configuration - General
2.1 Flow Chart ............................................. 10
2.2 Loop of Programming ........................... 11
2.3 Factory Default Settings ........................ 11
2.4 Main Page of Configuration ................... 12
Cha pter 3 Interface and Reading Mode
Selection
3.1 Interface Selection ................................. 13
3.2 Reading Mode Selection........................ 14
Chapter 4 Communication Parameters
4.1 RS232 Mode Parameters ...................... 15
4.2 Keyboard Wedge Mode Parameters..... 17
4.3 Output Characters Parameters ............. 19
4.4 Wand Emulation Mode Parameters...... 21
4.5 OCIA Mode Parameters ........................ 22
Chapter 5 Bar Codes & Others
5.1 Symbologies Selection ......................... 23
5.2 UPC/EAN/JAN Parameters ................... 26
5.3 Code 39 Parameters ............................. 28
5.4 Code 128 Parameters ........................... 30
5.5 Interleave 25 Parameters ...................... 32
5.6 Industrial 25 Parameters ....................... 34
5.7 Matrix 25 Parameters ............................ 36
5.8 CODABAR/NW7 Parameters ............... 38
5.9 Code 93 Parameters ............................. 40
5.10Code 11 Parameters ............................. 42
5.11 MSI/PLESSEY Code Parameters ......... 44
5.12BC412 Code Parameters ...................... 46
Page 2
2
5.13Code 2 of 6 Parameters ........................ 48
Cha pter 6 Miscella neous Para meters
6.1 Language Selection .............................. 50
6.2 Bar Code ID .......................................... 52
6.3 Reading Level ........................................ 55
6.4 Accuracy ............................................... 55
6.5 Buzzer Beep Tone ................................. 55
6.6 Sensitivity of Continuous Reading Mode ... 56
6.7 Notebook Function ................................ 56
6.8 Reverse Output Characters .................. 56
6.9 Set Up Deletion ...................................... 57
6.10Set Up Insertion ..................................... 60
Appendix
A. Decimal Value Tables ............................ 63
B. ASCII Tables .......................................... 64
C. Function Key Tables .............................. 68
Page 3
3
Chapter 1 Description
1.1 Notice
The manufacturer shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages in con­nection with the furnishing, performance, or use of this publication.
FCC Approval
This device had been test in accordance with the procedures given in ANSI C63.4 (1992) and con­firmed to complies with the limits for a CLASS B digital pursuant to part 15 of the FCC Rules.
CE Standards
The CE mark as shown here indicates this product had been tested in accordance with the procedures given in European Council Directive 89/336/EEC and confirmed to comply with the European Stan­dard EN55022:1994/ A1: 1995 Class B, EN 55024/
1998.
Page 4
4
1.2 Introduction
The Decoder is an advanced and versatile decoding facility for barcoding systems .It works with variety of bar code types, reading devices, and computer interfaces. It discriminates about twenty different symbologies automatically.
This menu provide an easy way to config the decoding options and interface selections by scanning bar codes listed in the menu.
1.3 Codes Read
. Codes Read
ALL UPC/EAN/JAN , Code 39, Code 39 Full ASCII, Code 128, Interleave 25, Industrial 25, Matrix 25, CODABAR/NW7, Code 1 1, MSI/PLESSEY, Code 93, China Postage, Code32/Italian Pharmacy Others available upon request.
1.4 Installation
Unpacking –
Remove the scanner from its packing and check it for damage. If the scanner was defected in transit, please contact your vendor immediately. Be sure that you keep the packing with all accessories contains in the package for your returning of service.
Connecting the scanner –
Keyboard wedge/RS-232C/USB: Connect the 10-pins RS-45 male connector into the bottom of the scanner and you will hear a “click” when the connection is made.
Page 5
5
Power supply for RS-232C scanner–
There are 3 ways to supplying the power, use ex­ternal +5V power supply, use optional power cable (KBDC) which taking the power from KB wedge or if the host supports +5V power from pin 9.
Installing the scanner to the Host System –
1. Turn off the host system.
2. Connect the power if needed.
3. Connect to the proper port on the host system.
4. Turn on the host system.
Switching cable –
Before removing the cable from the scanner, it is recommended that the power on the host system is off and the power supply has been disconnected from unit.
1. Find the small “Pin-hole” on the bottom of the unit.
2. Use a bended regular paperclip and insert the tip into the hole.
3. Y ou will head a “click”, then gentle on the strain­relief of the cable and it will slide out of the scanner.
SG/LG Series
SD Series
Page 6
6
1.5 Pin Assignment
A> Input Port for Mini Decoder
DB 9 Male
Pin No. Wa nd / CCD /
Slot Reader Laser Scanner 1 N.C. S.O.S. 2 DATA DATA 3 N.C. N.C. 4 N.C. N.C. 5 N.C. TRIGGER 6 N.C. P. E. 7 GND GND 8 SHIELD SHIELD 9 +5V +5V
B> Output Port
1. PC Keyboard Output DIN 5 MALE DIN 5 FEMALE
Pin No. Function Pin No. Function
1 HOST CLK 1 KB CLK 2 HOST DAT A 2 KB DATA 4 GND 4 GND 5 Vcc(+5V) 5 Vcc(+5V)
MiniDIN 6 MALE MiniDIN 6 FEMALE
Pin No. Function Pin No. Function
1 HOST DAT A 1 KB DATA 3 GND 3 GND 4 Vcc 4 Vcc 5 HOST CLK 5 KB CLK
4
5
3
2
1
5
4
1
2
3
3
1
5
4
2
6
3
1
5
4
2
6
1
6
9
5
Page 7
7
6
1
5
9
1
2
4
3
1
3
2
4
6
7
8 5 2
1
3
4
2
5
1
3
8
7
6
4
6
1
5
9
2. RS-232 Output DB 9 Female
Pin No. Function
2 TXD 3 RXD 5 GND 7 CTS 8 RTS
Power Lead Vcc (+5V)
3. WAND Emulation Output DB 9 Female
Pin No. Function
2DATA 7 GND 9 Vcc (+5V)
4. ADB Interface
MiniDIN 4 MALE MiniDIN 4 FEMALE
Pin No. Function Pin No. Function
1 ADB 1 ADB 3 Vcc 3 Vcc 4 GND 4 GND
5. NEC 9801 Interface
MiniDIN 8 MALE MiniDIN 8 FEMALE
Pin No. Function Pin No. Function
1 RST 1 RST 2 GND 3 GND 3 RDY 4 RDY 4 RXD 5 RXD 5 RTY 4 RTY 8 +5V 5 +5V
Page 8
8
1.6 Specification
SD20X SD30X SD80X
Interface TTL, Keyboa
rd,
Code Read ALL UPC/EAN/JAN , Code 39, Code 39
CODABAR/NW7, Code 11, MSI/PLE
With of Window 60mm 80mm 60mm
Depth of Field 25mm 25mm 100mm
Resolution
Ambient Light 1500Lux 1500Lux 1500Lux
Scan Speed 100 100 100
Voltage
Operating Temperature 0oC
Storage Temperature -20oC
Relative Humidity 20%
Cable
Page 9
9
SD90X SD100X SG30X LG3XX
80mm 75mm 50mm 50mm
150mm 100mm 300mm 300mm
0.127mm(5 mil)
1500Lux 1500Lux 100,000Lux 100,000Lux
100 100 270 36 - 100
DC +5V ± 5%
to 40oC (32oF to 104oF)
to 60oC (-4oF to 140oF)
to 85% (Non-Condensing)
Straight, 5 ft.
Page 10
10
Chapter 2 Configuration - General
2.1 Flow Chart
Page 11
11
2.2 Loop of Progra mming
The philosophy of progra mming parameters ha s been shown on the flow chart of 2.1. Ba sically user should
1. Scan Start of Configuration.
2. Sca n all necessary labels for para meters that meet
a pplications.
3. Scan End of Configuration to end the
progra mming.
4. To permanently save the settings you
progra mmed, just scan la bel for Save Para meters.
5. To go back to the Default Settings, just scan la bel
for Set All Defaults.
2.3 Fa ctory Default Settings
The factory default settings are shown with < > a nd bold in the following sections. You can make your own settings by following the procedures in this manual. If you wa nt to save the settings perma nently, you should scan the label of "Save Parameters" in cha pter 2.4, otherwise the settings will not be saved after the decoder power is off, and all settings will go back to previous settings.
By scanning "Set All Default" la bel, the settings will go back to the fa ctory default settings.
Page 12
12
%$ + / 0
%$ + / 1
%$ + / 2
%$ + / 3
%$ + / 4
%$ + / 6
%$ + / 5
2.4 Main Page of Configuration
Save Parameters
Recall Stored Parameters
Set All Defaults
Start Configuration
End Configuration
Abort Configuration
V ersion Information
Save Parameters -
The para meter settings will be saved perma nently .
Recall Stored Parameters -
Repla ce the current parameters by the parameters you saved la st ti me.
Set All Defaults -
Set all the para meters to the fa ctory default settings.
Abort Configuration -
Terminate current programming status.
V ersion Information -
Display the decoder version information and date code.
Page 13
13
Chapter 3 Interface and
Reading Mode Selection
3.1 Interface Selection
<Keyboard Mode>
RS232 Mode
WAND Emulation
OCIA Mode
USB Mode
%0 0 U 0
%0 0 U 8
%0 0 M2
%0 0 M4
%0 X O 8
Page 14
14
3.2 Reading Mode Selection
<Good Read OFF>
Trigger ON/OFF
Continuous/Trigger OFF
Testing
Continuous/Auto Power On
Flash
Flash/Auto Power On
Reserved1
Reserved2
Reserved3
Reserved4
Reserved5
%0271
%0270
%0272
%0275
%0273
%0274
%0276
%0277
%09F8
%09F9
%09FA
%09FB
Page 15
15
Ch.4 Communication Para meters
4.1 RS232 Mode Para meters A> Set Up BAUD Rate
600
1200
2400
4800
<9600>
19200
38400
B> Set Up Data Bits
7 Data Bits
<8 Data Bits>
C> Set Up Stop Bits
<1 Bit>
2 Bits
%0 Y 8 0
%0 Y 8 8
%0 Y 7 0
%0 Y 7 1
%0 Y 7 2
%0 Y 7 3
%0 Y 7 7
%0 Y 7 4
%0 Y O 8
%0 Y O 0
%0 Y 7 5
Page 16
16
D> Set Up Parity
<None>
Even
Odd
Mark
Space
E> Handsha king
RTS/CTS Enable
<RTS/CTS Disable>
ACK/NAK Enable
<ACK/NAK Disable>
XON/XOFF Enable
<XON/XOFF Disable>
%0 Y N 7
%0 Y N 2
%0 Y N 3
%0 Y N 1
%0 Y N 0
%0188
%0180
%0144
%0140
%0 3 K 4
%0 3 K 0
Page 17
17
4.2 Keyboard Wedge Mode Parameters A> T ermin al Type
<IBM PC/AT, PS/2>
IBM PC/XT
IBM PS/2 25, 30
NEC 9800
Apple Desktop Bus(ADB)
IBM 5550
IBM 122 Key (1)
IBM 102 Key
IBM 122 Key (2)
Reserved 1
Reserved 2
Reserved 3
Reserved 4
Reserved 5
%0 ZF0
%0 ZF1
%0 ZF2
%0 ZF3
%0 ZF4
%0 ZF5
%0 ZF6
%0 ZF7
%0 ZF8
%0 ZF9
%0 ZFA
%0 ZFB
%0 ZFC
%0 ZFD
Page 18
18
B> Upper/Lower Case
<No Change>
Upper Ca se
Lower Ca se
C> Send Character by ALT Method
Enable
<Disable>
D> Select Numerical Pa d
ON
<OFF>
%0 3 O 8
%0 3 O 0
%0 1 K 4
%0 1 K 0
%0330
%0331
%0332
Page 19
19
4.3 Output Chara cters Parameters
A> Select Terminator
<CR+LF>
None
CR
LF
Spa ce
HT(T AB)
STX-ETX
%7 S 0 +
%7 S 2 +
%7 S 4 +
%7 S 5 +
%7 S 7 +
%7 S 1 +
%7 S 3 +
Page 20
20
B> Time-out Between Characters
<0 ms>
5 ms
10 ms
25 ms
50 ms
100 ms
200 ms
300 ms
%0070
%0071
%0072
%0073
%0074
%0075
%0076
%0077
Page 21
21
4.4 Wand Emulation Mode Parameters A> TTL Level Repre sentation
<Bar Equals High>
Bar Equals Low
B> Scan Speed Selection
<Fast>
Slow
C> Output Format Selection
<Output as Code 39>
Output a s Code 39 Full ASCII
Output as Original Code Format
%0 2 K 4
%0 2 K 0
%0288
%0280
%0 2 O 8
%0 2 O 0
%0XK4
Page 22
22
4.5 OCIA Mode Parameters
<NCR 8 Bit Format>
NCR 9 Bit Format
Spectra-Physics
Nixdorf
%0 2 J 0
%0 2 J 1
%0 2 J 2
%0 2 J 3
Page 23
23
Ch.5 Bar Codes & Others
5.1 Symbologies Selection
UPC-A <ON>
OFF
UPC-E <ON>
OFF
EAN-13/JAN-13 <ON>
OFF
EAN-8/JAN-8 <ON>
OFF
CODE 39 <ON>
OFF
CODE 128 <ON>
OFF
CODABAR/NW7 <ON>
OFF
%0 A 4 4
%0 A 4 0
%0 B O 8
%0 B O 0
%0 A 2 2
%0 A 2 0
%0 A 1 1
%0 A 1 0
%0 E O 8
%0 E O 0
%0 F O 8
%0 F O 0
%0 J O 8
%0 J O 0
Page 24
24
Interleave 25 <ON>
OFF
Industrial 25 ON
<OFF>
Matrix 25 ON
<OFF>
CODE 93 ON
<OFF>
CODE 11 ON
<OFF>
China Postage ON
<OFF>
MSI/PLESSEY ON
<OFF>
% 0 GO8
% 0 GO0
%0 H O 8
%0 H O 0
%0 I O8
%0 I O0
%0 K O 8
%0 K O 0
%0 L O 8
%0 L O 0
%0 MO 8
%0 MO 0
%0 N O 8
%0 N O 0
Page 25
25
BC412 ON
<OFF>
Code 2 of 6 ON
<OFF>
Reserved4 ON
<OFF>
Reserved5 ON
<OFF>
Reserved6 ON
<OFF>
Select All Bar Codes
%1 A / +
% 0 OO8
% 0 OO0
%0 P O 8
%0 P O 0
% 0 QO8
% 0 QO0
%0 R O 8
%0 R O 0
%0 S O 8
%0 S O 0
Page 26
26
5.2 UPC/EAN/JAN Parameters A> Reading Type
UPCA=EAN13 ON
UPCA=EAN13<OFF>
ISBN Enable
ISBN <Disable>
ISSN Enable
ISSN <Disable>
Decode with Supplement
<Autodiscriminate Supplement>
B> Supplementals Set Up
<Not Transmit>
Transmit 2 Code
Transmit 5 Code
Transmit 2&5 Code
%0 AK4
%0 AK0
%0 B 8 8
%0 B 8 0
%0 B 4 4
%0 B 4 0
%0 B 3 3
%0 B 3 1
%0 B 3 2
%0 B 3 0
%0 1 O 0
%0 1 O 8
Page 27
27
C> Check Digit T ran smission
UPC-A Check Digit Transmission <ON>
OFF
UPC-E Check Digit Transmission <ON>
OFF
EAN-8 Check Digit Transmission <ON>
OFF
EAN-13 Check Digit Transmission <ON>
OFF
%0 A I 2
%0 A I 0
%0 B I 2
%0 B I 0
%0 A H 1
%0 A H 0
%0 A 8 8
%0 A 8 0
Page 28
28
5.3 Code 39 Parameters A> Type of Code
<Standard>
Full ASCII
Italian Pharmacy/Code 32
<OFF>
Italian Pharmacy/ Code 32 ON
B> Check Digit T ran smission
<Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
C> Output Start/Stop Character
Enable
<Disable>
%0 E H 1
%0 E H 0
%0 E 8 8
%0 E 8 0
%0 E M2
%0 E M6
%0 E M4
%0 E 4 4
%0 E 4 0
Page 29
29
D> Decode Asterisk
Enable
<Disable>
E > Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 E 1 +
%4 E 0 0
%4 E 0 1
%4 E 0 0
%4 E 0 2
%2 C 0 +
%2 + - /
%0 E 2 0
%0 E 2 2
Page 30
30
5.4 Code 128 Parameters A> Check Digit T ran smission
Do Not Calculate Check Digit
Calculate Check Digit & Transmit
<Calculate Check Digit & Not Tran smit>
B> Append FNC2
ON
<OFF>
C> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
%0 F N 7
%0 F N 5
%0 F 8 8
%0 F 8 0
%0 F N 1
Page 31
31
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value (Appendix A)
3. Complete
%4 F 1 +
%4 F 0 0
%4 F 0 1
%4 F 0 0
%4 F 0 2
%2 + - /
%2 C 1 +
Page 32
32
5.5 Interleave 25 Parameters A> Check Digit T ran smission
<Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
B> Set Up Number of Character
<Even>
Odd
C> Brazilian Banking Code
<Disable>
Enable
%0 G N 3
%0 G N 7
%0 GN 5
%0 G 8 8
%0 G 8 0
%0 G 4 0
%0 G 4 4
Page 33
33
D> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 G1 +
%4 G 0 0
%4 G0 1
%4 G0 0
%4 G0 2
%2 + - /
%2 C 2 +
Page 34
34
5.6 Industrial 25 Parameters A> Check Digit T ran smission
<Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
%0 HN3
%0 HN7
%0 HN5
Page 35
35
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value (Appendix A)
3. Complete
%4 H 1 +
%4 H 0 0
%4 H 0 0
%4 H 0 1
%4 H 0 2
%2 + - /
%2 C 3 +
Page 36
36
5.7 Matrix 25 Parameters A> Check Digit T ran smission
<Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
%0 I N 3
%0 I N 7
%0 I N 5
Page 37
37
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value (Appendix A)
3. Complete
%4 I 1 +
%4 I 0 0
%4 I 0 0
%4 I 0 1
%4 I 0 2
%2 + - /
%2 C 4 +
Page 38
38
5.8 CODABAR/N W7 Para meters A> Set Up Start/Stop Characters Upon
T ra nsmission
ON
<OFF>
B> Transmission Type of Start/Stop
<A/B/C/D> <Start>
<A/B/C/D> <Stop>
A Start
A Stop
B Start
B Stop
C Start
C Stop
D Start
D Stop
%0 J H 1
%0 J H 0
%0 4 V F
%0 4 F F
%0 4 V 1
%0 4 F 1
%0 4 V 2
%0 4 F 2
%0 4 V 4
%0 4 F 4
%0 4 V 8
%0 4 F 8
Page 39
39
C> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 J 1 +
%4 J 0 0
%4 J 0 0
%4 J 0 1
%4 J 0 2
%2 + - /
%2 C 5 +
Page 40
40
5.9 Code 93 Parameters
A> Check Digit T ran smission
<Calculate Check 2 Digits & Not Tran smit>
Do Not Calculate Check Digit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 K N 3
%0 K N 4
Page 41
41
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value (Appendix A)
3. Complete
%4 K 1 +
%4 K 0 0
%4 K 0 0
%4 K 0 1
%4 K 0 2
%2 + - /
%2 C 6 +
Page 42
42
5.10 Code 11 Para meters
A> Check Digit T ran smission
<Do Not Calculate Check Digit>
Calculate Check 1 Digit & Transmit
Calculate Check 1 Digit & Not Tran smit
Calculate Check 2 Digits & Transmit
Calculate Check 2 Digits & Not Tran smit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 L N 3
%0 L N 7
%0 L N 5
%0 L N 6
%0 L N 4
Page 43
43
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value (Appendix A)
3. Complete
%4L1+
%4L00
%4L00
%4L01
%4L02
%2 + - /
%2 C 7 +
Page 44
44
5. 11 MSI/PLESSEY Code Parameters
A> Check Digit T ran smission
<Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 NN3
%0 NN7
%0 NN5
Page 45
45
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value (Appendix A)
3. Complete
%4 N 1 +
%4 N 0 0
%4 N 0 0
%4 N 0 1
%4 N 0 2
%2 + - /
%2 C 9 +
Page 46
46
5.12 BC 412 Code Para meters
A> Check Digit T ran smission
Do Not Calculate Check Digit
<Calculate Check Digit & Tr a n smit>
Calculate Check Digit & Not Tran smit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 ON 3
%0 ON 7
%0 ON 5
Page 47
47
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value (Appendix A)
3. Complete
%4 O1 +
%4 O 0 0
%4 O 0 0
%4 O0 1
%4 O 0 2
%2 + - /
%2 C A +
Page 48
48
5.13 Code 2 of 6 Parameters
A> Check Digit T ran smission
Do Not Calculate Check Digit
<Calculate Check Digit & Tr a n smit>
Calculate Check Digit & Not Tran smit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 P N 3
%0 P N 7
%0 P N 5
Page 49
49
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value (Appendix A)
3. Complete
%4 P 1 +
%4 P 0 0
%4 P 0 1
%4 P 0 2
%4 P 0 0
%2 + - /
%2 C B +
Page 50
50
Ch.6 Miscella neous Para meters
6.1 Language Sele ction
<US English>
UK English
Italia n
Spanish
French
German
Swedish
Switzerland
Hungaria n
Ja panese
%0 Z V 0
%0 Z V 1
%0 Z V 2
%0 Z V 3
%0 Z V 4
%0 Z V 5
%0 Z V 6
%0 Z V 7
%0 Z V 8
%0 Z V 9
Page 51
51
Belgium
Portuguese
Denmark
Netherlands
Turkey
Reserved1
%0 Z V A
%0 Z V B
%0 Z V C
%0 Z V D
%0 Z V E
%0 Z V F
Page 52
52
6.2 Bar Code ID
ON
<OFF>
Default
With this function ON, a leading character will be added to the output string while scanning code, user may refer to the following table to know what kind of bar code is being scanned.
Plea se refer to the table below f or matching code ID of codes read in.
Code Type ID Code Type ID
UPC-A A UPC-E B EAN-8 C EAN-13 D CODE 39 E CODE 128 F Interleave 25 G Industrial 25 H Matrix 25 I Codabar/NW7 J CODE 93 K CODE 1 1 L China Postage M MSI/PLESSEY N BC412 O
User Define Code ID
To set the code ID:
1. Scan the symbologies label.
2. Go to the ASCII Tables in Appendix B, scan label that represents the desired code ID.
Note: User define code ID will override default value. Progra m will not che ck the conflict. It is possible to have more than two symbologies which have sa me code ID.
%0 0 H 1
%0 0 H 0
%913+
Page 53
53
UPC-A
UPC-E
EAN-13/JAN-13
EAN-8/JAN-8
CODE 39
CODE 128
CODABAR/NW7
Interleave 25
Industrial 25
Matrix 25
CODE 93
CODE 11
China Postage
MSI/PLESSEY
BC412
%9 1 A +
%9 1 B +
%9 1 Y +
%9 1 Z +
%9 1 E +
%9 1 F +
%9 1 G +
%9 1 H +
%9 1 I +
%9 1 J +
%9 1 K +
%91L+
%9 1 O +
%9 1 M+
%9 1 N +
Page 54
54
Code 2 of 6
Reserved4
Reserved5
Reserved6
%9 1 P +
%9 1 Q +
%9 1 R +
%9 1 S +
Page 55
55
6.3 Reading Level
Bar Equals High
<Bar Equals Low>
6.4 Accuracy
<1 Time>
2 Times
3 Times
4 Times
6.5 Buzzer Beep Tone
<High>
Medium
Low
Off
%0130
%0131
%0132
%0133
%0 1 J 3
%0 1 J 2
%0 1 J 1
%0 1 J 0
%0 3 I 0
%0 3 I 2
Page 56
56
6.6 Sensitivity of Continuous Reading Mode
<Fast>
Slow
6.7 Notebook Function
Enable
<Disable>
6.8 Reverse Output Characters
<Disable>
Enable
%0388
%0380
%0344
%0340
%0 3 H 0
%0 3 H 1
Page 57
57
6.9 Setup Deletion
To setup the deletion of output characters:
1. Scan the label of the desired set below.
2. Scan the label of the desired symbology.
3. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the desired position to be deleted.
4. Scan the "Complete" label of "Character Position to be Deleted".
5. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the number of chara cters to be deleted.
6. Scan the "Complete" label of "Number of Chara cters to be Deleted".
Repeat the steps 1 - 6 to set additional deletion.
A> Select Deletion Set Number
1. 1st Set
2. 2nd Set
3. 3rd Set
4. 4th Set
5. 5th Set
6. 6th Set
%800+
%801+
%802+
%803+
%804+
%805+
Page 58
58
B> Symbologies Selection
UPC-A
UPC-E
EAN-13/JAN-13
EAN-8/JAN-8
CODE 39
CODE 128
CODABAR/NW7
Interleave 25
Industrial 25
Matrix 25
CODE 93
CODE 11
China Postage
MSI/PLESSEY
%8 1 A +
%8 1 B +
%8 1 Y +
%8 1 Z +
%8 1 E +
%8 1 F +
%8 1 J +
%8 1 G +
%8 1 H +
%8 1 I +
%8 1 K +
%81L+
%8 1 M+
%8 1 N +
Page 59
59
BC412
Code 2 of 6
Resvered4
Resvered5
All Codes
None
C>
Character Position to be Deleted
1. Decimal V alue
(Appendix A) 2. Complete
D>
Number of Characters to be Deleted
1. Decimal V alue
(Appendix A) 2. Complete
%8 1 O +
%8 1 P +
%8 1 Q +
%8 1 R +
%8 1 S +
%820+
%830+
%814+
Page 60
60
6.10 Setup Insertion
To setup the insertion of output chara cters:
1. Scan the label of the desired set.
2. Scan the label of the desired symboligy.
3. Go to the Decimal V alue T ables in Appendix A, sca n label(s) that represents the desired position to be inserted.
4. Scan the "Complete" label of "Character Position to be Inserted".
5. Go to the ASCII Tables in Appendix B or Function Key Tables in Appendix C, scan label(s) that represents the desired chara cters to be inserted.
6. Scan the "Complete" label of "Characters to be Inserted".
Repeat the steps 1 - 6 to set additional insertion.
A> Select Insertion Set Number
1. 1st Set
2. 2nd Set
3. 3rd Set
4. 4th Set
5. 5th Set
6. 6th Set
%500+
%502+
%503+
%504+
%505+
%501+
Page 61
61
B> Symbologies Selection
UPC-A
UPC-E
EAN-13/JAN-13
EAN-8/JAN-8
CODE 39
CODE 128
CODABAR/NW7
Interleave 25
Industrial 25
Matrix 25
CODE 93
CODE 11
China Postage
MSI/PLESSEY
%5 1 A +
%5 1 B +
%5 1 Y +
%5 1 Z +
%5 1 E +
%5 1 F +
%5 1 G +
%5 1 J +
%5 1 H +
%5 1 I +
%5 1 K +
%51L+
%5 1 M+
%5 1 N +
Page 62
62
BC412
Code 2 of 6
Resvered4
Resvered5
All Codes
None
C>
Character Position to be Inserted
1. Decimal V alue
(Appendix A) 2. Complete
D>
Characters to be Inserted
1. ASCII T able
(Appendix B) 2. Complete
%520+
%530+
%514+
%5 1 O +
%5 1 P +
%5 1 Q +
%5 1 S +
%5 1 R +
Page 63
63
Appendix A Decimal Value Table
8
0
1
2
3
4
5
6
7
9
Page 64
64
Appendix B ASCII Table
NULL SOH
STX
ETX EOT
ENQ
ACK BEL
BS
HT LF
VT
FF CR
SO
SI DLE
DC1
DC2 DC3
DC4
NAK SYN
ETB
CAN EM
SUB
ESC FS
GS
RS US
03
00
02
01
04
05
06 07
08
09 0A
0B
0C 0D
0E
0F 10
11
12 13
14
15 16
17
18 19
1A
1B 1C
1D
1E 1F
Page 65
65
SPACE !
"
#$
%
&'
(
)*
+
,-
.
/0
1
23
4
56
7
89
:
;<
=
>?
20 21
22
23 24
25
26 27
28
29 2A
2B
2C 2D
2E
2F 30
31
32 33
34
35 36
37
38 39
3A
3B 3C
3D
3E 3F
Page 66
66
@A
B
CD
E
FG
H
IJ
K
LM
N
OP
Q
RS
T
UV
W
XY
Z
[\
]
^_
40 41
42
43 44
45
46 47
48
49 4A
4B
4C
4E
4D
4F 50
51
52 53
54
55 56
57
58 59
5A
5B 5C
5D
5E 5F
Page 67
67
`a
b
cd
e
fg
h
ij
k
lm
n
op
q
rs
t
uv
w
xy
z
{|
}
~ DEL
60 61
62
63 64
65
66 67
68
69 6A
6B
6C 6D
6E
6F 70
71
72 73
74
75 76
77
78 79
7A
7B 7C
7D
7E 7F
Page 68
68
Appendix C Function Key Table
F1 F2
F3
F4 F5
F6
F7 F8
F9
F10 F11
F12
Insert Delete
Home
Page Up Page Down
End
Left Right
Up
Down
C1C0
C2
C3 C4
C5
C6 C7
C8
C9 CA
CB
CC CD
CE
CF D0
D1
D2 D3
D4
D5