Digimerge DPZ16TO27, DPZ16WO37 Instruction Manual

Copyright © 2009 Digimerge Technology Inc.
www.digimerge.com
Right For Business
INSTRUCTION MANUAL
English Version 1.0
INDOOR/OUTDOOR
DPZ16TO27 DPZ16WO37
Speed Dome Camera Instruction Manual 2/49
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN THE COVERS.
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONAL
This lightning flash with arrowhead symbol is intended to alert the user to the presence of un-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
This Device compiles with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interface, and (2) This device must accept any interference received, including
interference that may cause undesired operations.
Speed Dome Camera Instruction Manual 3/49
Important Safety Guide
1. Read, heed and follow all the Instructions Read all the safety and operating instructions before using the product.
2. Keep this manual Keep this manual for reference in future.
3. Attachments / Accessories Use only the attachments or accessories specified by the manufacturer.
4. Installation
z Do not install near any heat resources such as radiators, heat registers, stoves, or other
appratus including amplifiers that product heat. Improperly installed product may fall, cause serious injury to a child or adult and damage the product.
z Do not block any ventilation holes or openings. Install in accordance with the
manufacturer’s instructions.
z Use only with the cart, stand, tripod, bracket, mounting devices, or table specified by
the manufacturer.
z Installation should be done only by qualified personnel and conform to all the
instructions by the manufacturer.
z Refer all servicing to qualified service personnel. z Unless the product is specifically marked as IP66, more than IP66 or confirmed by the
manufacturer, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
z Do not load on the product. z Use stainless steel hardware to fasten the mount. z To prevent damage from water leakage when installing a mount outdoors on a roof or
wall, apply sealant properly around holes.
z These servicing instructions are for use by qualified service personnel only. To reduce
the risk of electric shock, do not perform any servicing other that contained in the operationg instructions unless you are qualified to do so.
z Use only replacement parts specified by the manufacturer.
5. Power source
This product should be operated only from the type of the power source indicated on the marking label.
NOTICE
Speed Dome Camera Instruction Manual 4/49
Caution
Operating
z Before using, make sure that the power supply and others are properly installed. z While operating, if any abnormal condition or malfunction is observed, stop using the
product immediately and then contact your local dealer.
Handling
z Do not disassemble or tamper with the parts inside the product. z Do not drop or subject the product to shock and vibration as this can damage the
product.
z Care must be taken when you clean the clear dome cover. Especially, scratch and dust
will ruin the quality of the product.
Installation and Storage
z Do not install the product in areas of extreme temperature, which exceed the allowable
range.
z Avoid installing in humid or dusty places. z Avoid installing in places where radiation is present. z Avoid installing in places where there are strong magnetic fields and electric signals. z Avoid installing in places where the product would be subject to strong vibrations.
NOTICE
Speed Dome Camera Instruction Manual 5/49
Introduction
Feat ures 6 Package Components 8 Main Part Description 9
Installation
DIP Switch Setup 10
Installation with Ceiling Mount Bracket 13
Installation with Wall Mount Bracket 14
Wiring and Cabling 15
Operation
Check Point before Operation 18
Check Points for Preset and Pattern Function before Operation 18
OSD Menu 19
Reserved Preset (Hot Keys) 19
Preset 20 Swing 20
Pattern 21
Group 22
Other Functions 22
OSD Display 24
OSD Menu
Quick Programming Guide 25
Main Menu 25
Display Setup 26
Privacy Zone Mask Setup 27
Camera Setup 29
Motion Setup 34
Preset Setup 37 Swing Setup 39
Pattern Setup 40
Group Setup 41
System Initialize 44
Specifications
45
Dimension 49
TABLE OF CONTENTS
Speed Dome Camera Instruction Manual 6/49
Fe at ur es
Powerful Zoom Camera & Setup Options
z Image Sensor : 1/4" Double density interline transfer CCD (DPZ16WO37 model)
1/4" Super HAD color CCD (DPZ16TO27 model)
z Zoom : ×27 Optical Zoom, ×12 Digital Zoom (DPZ16TO27 model)
×37 Optical Zoom, ×12 Digital Zoom (DPZ16WO37 model)
z Day & Night, Privacy Mask, WDR and HLC (WDR :
DPZ16WO37 model
only)
z SNR (Super Noise Reduction) Function z Various Focus Mode : Auto-Focus, Manual Focus, Semi-Auto Focus z Various Setup Options in OSD Menu.
Powerful Pan/Tilt Functions
z MAX. 360°/sec High Speed Pan/Tilt Motion z With the Vector Drive Technology, Pan/Tilt motions are accomplished along the
shortest path. As a result, the time to target view is remarkably short and the video on the monitor is very natural in monitoring.
z With the Micro-Stepping Control Technology, the video looks very natural at high
zoom magnification during a jog operation on a controller since the camera can be controlled by 0.05°/sec. Hence it is very easy to make the camera focus on desired target views at high zoom magnification. Additionally it is easy to make the camera focus on desired positions with zoom-proportional pan/tilt movement.
Preset, Pattern, Swing, Group, Privacy Mask and More…
z MAX. 127 Presets are programmable and each preset can have its own parameter
values independently from the other presets. For an example, refer to the below table.
Preset No. White Balance Auto Exposure ••• Label Remarks
Preset 1 Case A Case 3 “ENTRANCE”
Preset 2 Case C Case 5 “WAREHOUSE”
Preset 3 Case V Case 2 “OFFICE”
•••
Preset 95 Reserved for OSD Menu
•••
Preset 128 Case K Case 9 “TERRACE”
INTRODUCTION
1
Speed Dome Camera Instruction Manual 7/49
z MAX. 8 sets of Swing are programmable. This function is that the camera moves
repetitively between two preset positions at programmed speeds.
z MAX. 4 Patterns are programmable. This function is that the camera memorizes the
path (mostly curve path) by the joystick of the controller and revives the trajectory operated by the joystick as closely as possible.
z MAX. 8 sets of Group are programmable. This function is that the camera memorizes
the combination of Presets, Pattern and/or Swings sequently and runs Presets, Pattern and/or Swings repetitively. A Group can be combined upto 20 functions with any of Preset/Pattern/Swing.
z MAX. 8 Privacy Masks are programmable, not to intrude on any other’s privacy.
PTZ(Pan/Tilt/Zoom) Control
z With the RS-485 communication connection, MAX. 255 units of cameras can be
connected to a single controller.
z Pelco-D or Pelco-P protocols can be selected as a control protocol in the current
firmware version.
OSD(On Screen Display) Menu
z OSD menu is provided to display the status of camera and to configure the functions
interactively.
z The information such as Camera ID, Pan/Tilt Angle, Direction, Alarm Input and Preset
is displayed on screen.
Alarm In/Out Function(Only for the models which have I/O function)
z 3 alarm sensor inputs and 1 alarm sensor outputs are available. z The camera can be set to move to a Preset position or to run functions such as Pattern,
Swing and Group when there are external sensor activations. Also “Post Alarm” function is possible, which is supposed to activate after user-defined time period and sequentially in succession to the action by external sensor activations.
Reserved Presets(Hot Keys)
z Most camera setup options can be set up easily and directly with the reserved presets
(Hot Keys), without entering into OSD menu. For more information, refer to “Reserved Presets(Hot Keys)” in this manual.
Perfect Outdoor Environment Compatibility and Easy Installation
z The fans and heaters are built-in in the camera for cold and hot temperature
environment. Also idealistic mechanical design protects the camera from water and dust. (IP66 when installed properly with wall mount bracket only)
INTRODUCTION
1
Speed Dome Camera Instruction Manual 8/49
Package Component
Product & Accessories
z Main Body & Surface Mount Bracket z Default Accessories
[Main Cable, Wrench]
z Accessories for The Models with Alarm In/Out
Function [I/O Cable]
Brackets (Optional)
z Wall Mount Bracket (Optional)
[Screws : Machine M5×15, Hex Lag #14×50]
z Ceiling Mount Bracket (Optional)
[Screws : Machine M5×15, Anchor Bolt 3/8"×70]
INTRODUCTION
1
Speed Dome Camera Instruction Manual 9/49
Main Part Description
D
IP Switc
h
Dome Cover
Sensor I/O Port (I/O Model)
Main Connector
Mounting Hook
Mounting Screw Hole
z Dome Cover Do not detach the protection vinyl from the dome cover before
finishing all the installation process to protect the dome cover from scratches or dust.
z DIP Switch Used to set up camera IDs and protocols.
z Mounting Hook Used to assemble the main body with wall mount bracket or
ceiling mount bracket. Insert the mounting hooks into the holes on the surface of the main body and turn the main body.
z Mounting Screw Hole Used to assemble the main body with a bracket with screws.
z Main Connector Us ed f or the powe r wire, th e vide o cabl e and the R S-485
communication cable connection.
z Sensor I/O Port Used for the sensor in/out connection. (The sensor I/O function
possible models only)
INTRODUCTION
1
Speed Dome Camera Instruction Manual 10/49
DIP Switch Setup
Before installing the camera, set up the DIP switch to configure the camera ID and the communication protocol.
Camera ID Setup
ON
ON
12345678
z ID numbers of cameras are set up with binary numbers.
See the examples shown below.
Pin 1 2 3 4 5 6 7 8
Binary Value 1 2 4 8 16 32 64 128
ex) ID=5 on off on off off off off off ex) ID=10 off on off on off off off off
z The camera ID range is “1~255”. Camera ID must not be
“0”!
z The factory default of the camera ID is “1”. z Match the camera ID with the Cam ID setting of your DVR
or Controller to control the camera.
z If you are connecting a single camera to a controller,
terminate the camera. When connecting more than one camera to a single controller, terminate the last camera on the communication line. The last camera means the camera farthest in cable length from the controller.
z Note that the total length of the communication cable
between a controller and the camera(s) on the same communication line must be less than 1.2Km.
INSTALLATION
2
Speed Dome Camera Instruction Manual 11/49
Communication Protocol Setup
1234
ON
ON
z Select an appropriate Protocol with the DIP switch combination.
Switch Mode
P0
(Pin 1)
P1
(Pin 2)
P2
(Pin 3)
Protocol
OFF OFF OFF PELCO-D, 2400 bps
ON OFF OFF PELCO-D, 9600 bps
OFF ON OFF PELCO-P, 4800 bps
ON ON OFF PELCO-P, 9600 bps
Others Reserved
z Match the camera protocol with the camera protocol in the setting of
your DVR or controller to control the camera.
z Adjust the DIP switch after turning off the camera. If you changed the
camera protocol by changing the DIP S/W, the change will be effective after you reboot the camera.
z The factory default protocol is “Pelco-D, 2400 bps”.
INSTALLATION
2
Speed Dome Camera Instruction Manual 12/49
Terminal Resistor Setup
1234
ON
ON
T
he terminal resistor is used for the following cases.
z Case 1 : In case that the control cable length between a camera and
a controller is relatively very long (1:1 Connection)
If the communication cable length is very long, the electrical signal will bound in the terminal point. This reflected signal causes distortion of original signal. Accordingly, the camera can be out of control. In this case, the terminal resistor of both sides i.e. the camera and the controller must be set to ‘ON’ state.
z Case 2 : In case that multiple cameras are connected to a
controller.
Due to similar reasons with the case 1, the terminal resister of the controller and the last camera must be set to ‘ON’ state. The last camera means the camera farthest in cable length from the controller. Do not turn on the terminal resistor of all the cameras on the same communication cable.
Controller
#1 #2 #n
Terminal Resistor ON
RS-485
Terminal Resistor
OFF
Terminal Resistor
OFF
Terminal Resistor
ON
INSTALLATION
2
Speed Dome Camera Instruction Manual 13/49
Installation with Ceiling Mount Bracket (Optional)
Remove the ceiling tile from the ceiling
and cut a hole whose diameter is 30~40mm on the ceiling tile to pass the wire(s) and cable(s) through to the upside of the ceiling. (In case of the wiring and cabling through the mounting surface only) Then prepare the ceiling mount bracket. Pull the wire(s) for the system as below. (Anchor Bolt 3/8"×70)
Pull the wire(s) and cable(s) for the
system as below. Wire the cable(s) to the ports. Insert the mounting hooks into the holes on the surface of the main body and turn the main body. Assemble the main both with the camera mount adaptor with the 3 screws. (Machine M5×15)
Screw the dome cover to the main body
and remove the protection vinyl from the dome cover.
Important Notice
z Before starting the installation, make sure that the Camera ID and Protocol are set up properly. z To adjust the installation height from the mounting surface, the pipe and coupler should be needed
between the surface mount part of the ceiling mount bracket and the camera mount part of the ceiling mount bracket. Note that they are not supplied by the manufacturer.
INSTALLATION
2
Speed Dome Camera Instruction Manual 14/49
Installation with Wall Mount Bracket (Optional)
Make a hole whose diameter is 30~40mm
on the mounting surface to pass the wire(s) and cable(s) through the mounting surface. (In case of the wiring and cabling through the mounting surface only) Then prepare the wall mount bracket. Pull the wire(s) and cable(s) for the system as below. Attach the wall mount bracket to the mounting surface. (Hex Lag #14×50)
Pull the wire(s) and cable(s) for the
system as below. Wire the cable(s) to the ports. Insert the mounting hooks into the holes on the surface of the main body and turn the main body. Assemble the main both with the camera mount adaptor with the 3 screws. (Machine M5×15)
Screw the dome cover to the main body
and remove the protection vinyl from the dome cover.
Important Notice
z Before starting the installation, make sure that the Camera ID and Protocol are set up properly.
INSTALLATION
2
Speed Dome Camera Instruction Manual 15/49
Wiring and Cabling
RS-485
BNC
SENSOR I/O
MAIN CABLE
I/O CABLE
POWER
MONITOR
CONTROLLER / DVR
IR SENSOR
DOOR SWITCH
Port Description
z Main Cable
Port Pin Number (RJ45) Connector / Wire Color Signal
1 Video +
2,4
BNC Connector
Video
5 Red RS-485 +
3 Yellow RS-485
7 Orange Power +
6,8 White Power
z I/O Cable
Port Pin Number (RJ25) Wire Color Signal
1 Blue IN COM +
2 Yellow IN 1
3 Green IN 2
4 Red IN 3
5 Black OUT A
6 White OUT B
z Audio Cable
Port Pin Number Connector / Wire Color Signal
1 RCA (Yellow) Audio IN
2 Audio GND
3 RCA (White) Audio OUT
INSTALLATION
2
Loading...
+ 34 hidden pages