Digilock DAR1-APV1, DAR1-APS1 Product Manual

DAR1-APS1 & DAR1-APV1
Phone: 707 766 6000
www.digilock.com | sales@digilock.com
RFID Locks Advanced Security
Assigned Use
Product Guide
RFID locks operate with an RFID Card. In assigned use functionality, an RFID Card is assigned to operate the lock. The user presents the assigned RFID Card to unlock and closes the door to automatically lock. Management staff operates the lock with either the Programming Key unique to the lock system or any registered Manager Bypass Key.
Front Unit
Lock Parts
Vertical Body
DAR1-APV1
Key Slot
Pull Handle
Rear Unit
Vertical Body
Key Insertion
Digilock logo must face up on standard and vertical body locks.
Standard Body
User Key
Operates the lock instead of
RFID Card
ADA compliant*
Keys
Manager Bypass Key
Assigns RFID Card and User Key
Provides lock access in case of forgotten/lost
user credential (card or key)
Allows management audit/inspection
Provides external power in case of battery failure
Up to 25 Manager Bypass Keys may be registered
per lock
Programming Key
Registers Manager Bypass Keys
Provides lock access in case of forgotten/lost user
credential (card or key)
Allows management audit/inspection
1 Programming Key required per lock system
*US Access Board requires 5% of all locks to be ADA compliant.
Advanced Security
Cover Plate
Cover Plate Screws
Mounting Holes
1/2” (12mm) Deadlatch
Key Button
Standard Body
DAR1-APS1
Pull Handle
Key Slot
Reader
Key Button
LED Usage Indicator
LED Usage Indicator
Reader
RF ID
CARD
RFID Card
DAR1-APS1 & DAR1-APV1
Phone: 707 766 6000
www.digilock.com | sales@digilock.com
RFID Locks Advanced Security
Assigned Use
Product Guide
Programming Instructions
New locks operate only with `. Locks must be setup to allow full operation.
Manager Bypass Key(s) can be quickly registered to multiple locks. The Programming Key copies the registered Manager Bypass Key(s) from one lock to multiple locks.
Initial Setup
Express Register
a. Go to the lock registered with the Manager Bypass Key(s). b. Press and hold ` for 10 seconds. After 5 seconds, a two-tone beep will be heard and the LED will start to flash; continue to
hold until two-sets of two-tone beeps are heard.
c. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off. d. At each lock to be registered, touch the Programming Key to the key slot until a two-tone beep is heard and the LED flashes
once to indicate successful registration.
e. End express registration.* Go to any registered lock and press ` then touch the Programming Key to the key slot to operate
the lock.
Up to 25 Manager Bypass Keys may be registered to a lock. If required, contact your Digilock Product Representative to order additional Manager Bypass Key(s).
a. Go to a lock requiring Manager Bypass Key(s). b. Press and hold ` for 5 seconds until a two-tone beep is heard and the LED starts to flash. c. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns on. d. Touch each Manager Bypass Key to the key slot. A two-tone beep will be heard for each Manager Bypass Key that is
successfully registered.
e. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off. f. Repeat above steps for each lock or follow Express Register instructions to register the same Manager Bypass Key(s) to
multiple locks.
Register/Add Manager Bypass Key(s)
*The Programming Key will continue to function in express registration mode until it is used to operate a lock.
a. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns on. b. Touch each Manager Bypass Key to the key slot. A two-tone beep will be heard for each Manager Bypass Key that is
successfully registered.
c. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns off. d. Repeat above steps for each lock or follow Express Register instructions to setup all locks.
For Lost or Stolen Keys
For a lost or stolen Programming Key:
The lost/stolen Programming Key will continue to operate the lock(s) until it is replaced. Immediately order a Replacement Programming Key from your Digilock Product Representative. Once received, follow enclosed instructions to set up the lock(s) to operate with the Replacement Programming Key.
For a lost or stolen Manager Bypass Key(s):
Lost/Stolen Manager Bypass Key(s) will continue to operate the lock(s). To prevent the lost/stolen Manager Bypass Key(s) from operating the lock(s), erase all registered Manager Bypass Key(s) and register only the remaining Manager Bypass Key(s).
a. Collect all remaining Manager Bypass Key(s). b. Press and hold ` for 5 seconds until a two-tone beep is heard and the LED starts to flash. c. Touch the Programming Key to the key slot until a two-tone beep is heard and the LED turns on. d. Touch the Programming Key to the key slot again until three sets of two-tone beeps are heard and the LED turns off.
All previously registered Manager Bypass Key(s) have been erased from the lock.
e. Follow Register/Add Manager Bypass Key(s) instructions to register the remaining Manager Bypass Key(s).
Loading...
+ 2 hidden pages