Digigram IQOYA *SERV/LINK User Manual

IQOYA *SERV/LINK user manual
IQOYA *SERV/LINK
Multichannel IP audio codec
Sept 2016
From firmware 2.05
1
IQOYA *SERV/LINK user manual
1. KEY HARDWARE FEATURES
1.1. Features common to all IQOYA *SERV/LINK 1U racks
1.2. IQOYA *SERV/LINK with analog and AES/EBU I/OS (*SERV/LINK882, *SERV/LINK16162)
1.3. IQOYA *SERV/LINK with AES/EBU only I/OS (*SERV/LINK881, *SERV/LINK16161, 24241, 32321)
1.4. IQOYA *SERV/LINK with MADI I/OS (base version: *SERV/LINK88-MADI)
1.5. IQOYA *SERV/LINK for transcoding only
2. KEY SOFTWARE FEATURES
2.1. Standard features
2.2. Optional software features
Physical interfaces
3.1. IQOYA *SERV/LINK Front Panel
3.1.1. LEDs
3.1.2. LCD display and keypad
3.1.3. Navigating menus on LCD display
3.2. IQOYA*SERV/LINK Back Panel
3.2.1. Back panel for analog & AES/EBU version, and AES/EBU versions
3.2.2. Back panel for MADI versions
3.2.3. Back panel for AES67 versions
3.2.4. Back panel for AES67/MADI versions
3.2.5. Optional -48VDC power supply
4. IQOYA *SERV/LINK working principle
4.1. Audio inputs and outputs
4.2. Programs
4.3. IP services
4.4. Audio buses
5. INSTALLATION
5.1. Grounding the IQOYA *SERV/LINK
5.2. Connecting the audio I/Os and synchronization clocks
5.3. Connecting IQOYA *SERV/LINK to the network
5.4. Powering up IQOYA *SERV/LINK
5.5. Steps to follow to configure IQOYA *SERV/LINK
6. Note that IQOYA *LINK can simultaneously encode, decode, and transcode.
7. Accessing IQOYA *SERV/LINK WEB pages
8. Configuration from the WEB pages
2
9. WEB pages organization
9.1. “Preferences” category of menus
9.1.1. Preferences -> System
9.1.1.1. Preferences -> System -> Properties
9.1.1.2. Preferences -> System -> Audio Clock
9.1.1.3. Preferences -> System -> Audio setup
9.1.1.4. Preferences -> System -> Alarms setup
9.1.1.5. Preferences -> System -> Logs
9.1.1.6. Preferences -> System -> Download / Upload
9.1.1.7. Preferences -> System -> Firmware update
9.1.1.8. Preferences -> System -> Password
9.1.1.9. Preferences -> System -> Shutdown / Restart
9.1.2. Preferences -> Services
9.1.2.1. Preferences -> Services -> NTP
9.1.2.2. Preferences -> Services -> FTP
9.1.2.3. Preferences -> Services -> SSH
9.1.2.4. Preferences -> Services -> SNMP
9.1.2.5. Preferences -> Services -> HTTPS
9.1.3. Preferences -> Network
9.1.3.1. Preferences -> Network-> Eth0 / Eth1
9.1.3.2. Preferences -> Network-> VLAN
9.1.3.3. Preferences -> Network-> IP routing
9.1.3.4. Preferences -> Network-> HTTP stream proxy
9.1.4. Preferences -> Auxiliary data
9.1.4.1. Preferences -> Auxiliary data -> Network-> HTTP stream proxy
9.2. Audio I/Os category of menus
9.2.1. Audio I/O -> Input
9.2.1.1. Audio I/O -> Input -> VU meters
9.2.1.2. Audio I/O->Input-> settings
9.2.2. Audio I/O -> Output
9.2.2.1. Audio I/O -> Output -> VU meters
9.2.2.2. Audio I/O->Output-> settings
9.2.2.3. Audio I/O->Audio Bus
9.3. “Send” category of menus
9.3.1. Send -> Programs
9.3.2. Send -> IP services
9.4. “Receive” category of menus
9.4.1. Receive-> IP services
IQOYA *SERV/LINK user manual
3
9.4.2. Receive-> Programs
Status
10. Managing sound files and playlists via FTP
11. Specifications Audio I/Os specifications for Analog & AES/EBU versions
11.1.1. CONFIGURATION
11.1.2. CONNECTIVITY
11.1.3. ANALOG INPUTS
11.1.4. ANALOG OUTPUTS
11.1.5. AES/EBU INPUTS
11.1.6. AES/EBU OUTPUTS
11.1.7. SYNCHRONIZATION INPUTS
11.1.8. MADI INPUTS/OUTPUTS
10.1.9. ANALOG AUDIO PERFORMANCES
IQOYA *SERV/LINK user manual
4
Important Safety Information: read carefully before using this equipment!
Follow these instructions and keep them in a safe place! Keep in mind that damages due to failure to observe the instructions contained in this manual are not covered by warranty.
Instructions importantes de sécurité: lire soigneusement avant d’utiliser l’équipement!
Lisez et suivez ces instructions. Conservez les pour consultation ultérieure! Les dommages dus au non-respect des instructions contenues dans ce manuel ne sont pas couverts par la garantie.
Wichtige Sicherheitshinweise: vor Inbetriebnahme des Gerätes sorgfältig lesen!
Befolgen Sie die Anweisungen und bewahren Sie sie für spätere Fragen auf! Bei Schäden, die durch Nichtbeachten dieser Bedienungsanleitung verursacht werden, erlischt der Garantieanspruch!
Throughout this manual, the lightning bolt triangle is used to alert the user to the risk of electric shock.
The exclamation point triangle is used to alert the user to important operating or maintenance instructions.
Do Not Open the Cabinet There are no user-serviceable components inside this product. Opening the cabinet may present a shock hazard, and any modification to the product will void your warranty. If it is necessary to open the device for maintenance or advanced configuration purposes, this is to be done by qualified personnel only after disconnecting the power cord and network cables!
Power supply The device is to be connected only to a power supply as specified in this manual and marked on the equipment. This equipment must be earthed! Do not block any of the ventilation openings!
Humidity To reduce the risk of fire or shock, do not expose this device to rain or moisture. Do not place objects filled with liquid on this device.
Installation Location To ensure proper operation and to avoid safety hazards, the device must be installed in a 19“ rack mount chassis. The electrical installation of the building should dispose of easily accessible disconnecting means in the immediate vicinity of the device. If rack installation is not possible, place it on a firm and level surface. The use of a supply lead with a power plug respecting the legal standards in the country of use is obligatory. The plug shall be easily accessible in case of a problem. Avoid installation in extremely hot or cold locations, or in an area that is exposed to direct sunlight or heating equipment. Avoid moist or humid locations. Connection of this product to an IT power supply system is only in Norway.
Cleaning Clean only with a soft, dry cloth. If necessary, after disconnecting the unit’s cables, wipe it with a soft cloth dampened with mild soapy water, then with a fresh cloth with clean water. Wipe dry immediately with a dry cloth. NEVER use benzene, aerosol cleaners, thinner, alcohol or any other volatile cleaning agent. Do not use abrasive cleaners, which may damage the finish of metal or other parts.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Moving the device Before moving the unit, be certain to disconnect any
Ne pas ouvrir l’appareil
L’ouverture du coffret peut produire un risque de choc électrique, et toute modification du produit annule votre garantie. S’il est nécessaire d’ouvrir l’appareil pour l’entretien ou la configuration avancée, cela doit être fait par du personnel qualifié, après avoir débranché le cordon d’alimentation et les câbles réseaux !
Alimentation Il est primordial de connecter l’appareil à une alimentation électrique telle que spécifiée dans ce manuel d´utilisateur et sur le matériel même. Cet équipement doit être raccordé à la terre ! N’obstruer aucune ouverture de ventilation !
Humidité Afin de réduire les risques de feu ou de choc, n’exposez pas cet appareil à la pluie ou l’humidité. Ne placez pas d´objet contenant un liquide sur l’appareil.
Installation, mise en place Afin d’assurer le fonctionnement correct et de minimiser les risques potentiels liés à la sécurité, l’appareil doit être installé dans un châssis 19 pouces. Si cela ne vous est pas possible, placez-le sur une surface solide et plane. Prévoir dans l’installation électrique du bâtiment un dispositif de sectionnement aisément accessible et à proximité immédiate de l’appareil. L’utilisation d’un câble d’alimentation avec une fiche de prise de courant respectant les normes en vigueur dans le pays d’utilisation est obligatoire. De plus la fiche de prise de courant doit être aisément accessible en cas de problème. Évitez une installation dans des endroits très chauds ou très froids ainsi que dans des lieux exposés directement au soleil. Évitez les lieux présentant un excès d’humidité. Le raccordement de ce produit à un régime d’alimentation IT n’est possible qu’en Norvège.
Nettoyage Nettoyez uniquement avec un chiffon doux et sec. Si nécessaire, après avoir débranché le cordon d´alimentation, essuyez-le avec un chiffon doux humidifié avec de l´eau savonneuse puis rincez le á l´aide d un chiffon propre et d´eau claire. Séchez-le immédiatement avec un chiffon sec. N’utilisez JAMAIS d´essence, de nettoyants en aérosols, d´alcool ou tout autre agent nettoyant volatile. N’utilisez pas de produits nettoyants abrasifs qui pourraient endommager les finitions métalliques ou d´autres pièces. Réparation Lorsque l’appareil a été endommagé quelle qu’en soit la cause ou qu’il ne fonctionne pas normalement, toute réparation doit être effectuée par du personnel qualifié. Avant de transporter l´unité, assurez-vous d´avoir bien
Gerät nicht öffnen Öffnen des Geräts kann eine Gefährdung durch Stromschlag und Erlöschen der Garantie zur Folge haben. Reparaturarbeiten und Änderungen der Hardwarekonfiguration dürfen nur von qualifiziertem Personal nach entfernen der Strom- und Netzwerkkabel durchgeführt werden.
Stromversorgung Das Gerät darf nur mit der in dieser Bedienungsanleitung und auf dem Gerät angegebenen Stromversorgung betrieben werden. Erdung ist zu gewährleisten! Belüftungsschlitze nicht verdecken! Wasser und Feuchtigkeit Um Brand- oder Stromschlagrisiken zu vermeiden, darf das Gerät nicht mit Feuchtigkeit in Berührung kommen.
Aufbau des Geräts Um den einwandfreien Betrieb zu gewährleisten und Sicherheitsrisiken zu vermeiden, sollte das Gerät in einem 19-Zoll Baugruppenrahmen montiert werden. Die elektrische Installation des Gebäudes sollte über einen leicht zugänglichen Trennschalter in unmittelbarer Nähe des Geräts verfügen Nur wenn die Installation im Rack nicht möglich ist, stellen Sie das Gerät auf einen festen, waagerechten Untergrund. Die Verwendung eines Anschlußkabels und eines Steckers, die die im Benutzungsland gültigen Normen erfüllen, ist obligatorisch. Des weiteren muß die Steckdose für einen eventuellen Problemfall leicht zugänglich sein. Meiden Sie Standorte in der Nähe von Wärme- oder Feuchtigkeitsquellen sowie direkte Sonneneinstrahlung. Anschluß dieses Produktes an eine spezielle IT-Stromversorgung ist nur in Norwegen genehmigt.
Reinigen des Geräts Säubern Sie das Gerät nur mit einem weichen, trockenen Tuch. Bei Bedarf verwenden Sie ein mit mildem Seifenwasser befeuchtetes Tuch, nachdem Sie die Netzanschlusskabel aus der Steckdose gezogen haben, anschließend ein weiches, mit klarem Wasser befeuchtetes Tuch. Trocken Sie das Gerät sofort im Anschluß. Keinesfalls Benzol, Verdünner oder sonstige starke Lösungsmittel oder Scheuerreiniger verwenden, da hierdurch das Gehäuse beschädigt werden könnte.
Lassen Sie etwaige Reparaturen nur von qualifizierten Fachleuten durchführen!
Sollten das Netzkabel oder der Netzstecker beschädigt sein, oder sollte das Gerät selbst beschädigt worden sein (z. B. durch Eindringen von Feuchtigkeit durch Fall auf den Boden), oder sollte es nicht ordnungsgemäß funktionieren oder eine deutliche Funktionsabweichung aufweisen, so ist es von qualifizierten Fachleuten zu reparieren.
IQOYA *SERV/LINK user manual
5
cables that connect with other components.
déconnecté le cordon d’alimentation ainsi que tous les câbles la reliant à d'autres appareils.
“This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.”
Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
CAN ICES-3 (A) / NMB-3 (A)
User safety
EMC
European Directive
2006/95/EC "Low Voltage Directive
Europe
: EN60950-1 (2006+A11/2009+A1/2010+A12/2011+A2/2013)
International
: IEC 60950-1 (2005+A1/2009+A2/2013)
European Directive
: EMC 2004/108/EC
Radio disturbance
:
International: CISPR22 (2008) Class A
IEC 61000-6-3 (2006+A1/2010)
European : EN55022 Class A (2010) Requirements for Information Technology Equipment (ITE)
EN 61000-6-3 (2007+A1/2011)
Immunity
: International : CISPR24 (2010)
IEC 61000-6-2 (2005)
European : EN55024 (2010) (ITE)
EN 61000-6-2 (2005)
Harmonics
: International : IEC 61000-3-2 (2005 + A1/2008 + A2/2009)
European : EN61000-3-2 (2006 + A1/2009 + A2/2009)
Voltage changes
: International : IEC 61000-3-3 (2013)
European :EN 61000-3-3 (2013)
United States
: CFR 47, FCC Part 15, Subpart A (Class A Digital Device)
& Industry Canada ICES-003 (Issue 5/2012)
RoHS
European directive 2011/65/EU aka “RoHS”
Note: to comply with standard EN55024, use shielded network cables!
INFORMATION FOR THE USER
IQOYA *SERV/LINK user manual
In order to guarantee compliance with the above standards in an installation, the following must be done:
the provided cables must not be modified.
additional cables used must have their respective shield connected to each extremity.
6
IQOYA *SERV/LINK user manual
Attach a ground wire to the chassis (ideally the ground wire has a ring terminal). Connect the other end of the ground wire to a good electrical ground point.
The limits specified in the standards are designed to provide reasonable protection against harmful interference in an industrial installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
reorient or relocate the receiving antenna.
increase the separation between the equipment and the receiver.
connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
consult the dealer or an experienced audio/television technician for help.
Note:
Connecting this device to peripheral devices that do not comply with CLASS A requirements or using an unshielded peripheral data cable could also result in harmful interference to radio or television reception. The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. To ensure that the use of this product does not contribute to
interference, it is necessary to use shielded I/O cables.
Copyright 2015 - Digigram. All rights reserved. No portion of this manual may be reproduced without prior written consent from Digigram. The copyright protection claimed here includes photocopying, translation and/or reformatting of the information contained in this manual. While every effort has been made to ensure accuracy, Digigram is not responsible for errors, omissions or typos, and reserves the right to make improvements or changes in the products and programs described without notice.
Digigram and the Digigram logo, visiblu and the visiblu logo, and IQOYA are registered trademarks or trademarks of Digigram S.A.. HE-AAC and AAC-(E)LD are registered trademarks or trademarks of Fraunhofer IIS. All other trademarks are property of their respective holders.
You have just acquired a Digigram IQOYA*SERV/LINK and we congratulate you!
IQOYA*SERV/LINK is a multi channel IP audio codecs of the IQOYA range based on Digigram FluidIP technology.
The manual at hand will guide through installation, configuration, and operation. For any software related issue, please refer to the specific documentation provided in its online help.
7
IQOYA *SERV/LINK user manual
1. KEY HARDWARE FEATURES
1.1. Features common to all IQOYA *SERV/LINK 1U racks
1U rack
Hot swappable redundant power supply units (220 VAC, optionally -48VDC)
2 x RJ45 10/100/1000 Mbits/s ports
Front panel display and keypad
1.2. IQOYA *SERV/LINK with analog and AES/EBU I/OS (*SERV/LINK882, *SERV/LINK16162)
8/8 or 16/16 balanced analog inputs/outputs, +24 dBu Max
4/4, 8/8 balanced stereo AES/EBU inputs/outputs
AES11 synchronization input
Word Clock synchronization input
Video Reference synchronization (black burst)
1 Sub-D 62 pin connector and 1 associated breakout cable per group of 8/8 mono analog channels and 4/4 stereo AES/EBU stereo channels
1.3. IQOYA *SERV/LINK with AES/EBU only I/OS (*SERV/LINK881, *SERV/LINK16161, 24241, 32321)
4/4, 8/8, 12/12 or 16/16 balanced stereo AES/EBU inputs/outputs
AES11 synchronization input
Word Clock synchronization input
Video Reference synchronization (black burst)
1 Sub-D 62 pin connector and 1 associated breakout cable per group of 4/4 AES/EBU channels
1.4. IQOYA *SERV/LINK with MADI I/OS (base version: *SERV/LINK88-MADI)
from 8/8 up to 128/128 mono I/O channels on MADI
Synchronization on MADI
Word Clock synchronization input
2 x RJ45 10/100/1000 Mbits/s Ethernet ports
1.5. IQOYA *SERV/LINK for transcoding only
from 8/8 up to 128/128 mono channels for internal busses.
2 x RJ45 10/100/1000 Mbits/s Ethernet ports
8
IQOYA *SERV/LINK user manual
2. KEY SOFTWARE FEATURES
2.1. Standard features
Simultaneous encoding, decoding, transcoding
Multi-format encoding and multi-protocol streaming of each input.
Support of unicast, multi-unicast, multicast, multi-multicast addressing
Support of IGMPv3
MPEG-TS/IP SPTS and MPTS streaming (encoding)
VLAN Tagging + DSCP
Support of DHCP
Asymmetric algorithmic encoding/decoding
3 decoding priorities
Automatic switching to a lower decoding priority in case of upper priority failure
3 decoding priorities per output program, with choice of the audio source on each priority: IP service (RTP, UDP, HTTP), file, playlist and Audio input
Possibility to disable/enable any defined priority
Possibility to stop streaming upon input silence detection with adjustable silence threshold and duration.
Dual port redundant streaming with time diversity up to 1 second
Selectable FECs (from +15% to +100% IP bandwidth)
Automatic audio format detection on the decoder
Real-time metrics on network path quality (jitter, lost packets, duplicated packets, disordered packets) for the primary stream as well as for the FEC stream.
Adjustable jitter buffer
Management of lost packets, disordered packets, duplicated packets, and AAC error concealment
RS232 tunneling
GPIO tunneling
WEB user rights management
NTP synchronization (date and time)
Save / load full codec configuration
Save / load audio configuration
Remote firmware update
Audio still active during firmware upload
Firmware version N and N-1 locally stored
SNMP SET, GET, Traps
2.2. Optional software features
CSR aptX Enhanced
Optional audio synchronization on NTP clock
Number of audio I/Os supported for MADI and AES67 base versions
Number of audio buses for IP streams transcoding
TM
audio format
9
Included
Otional
linear 16/20/24-bit PCM
ITU G.711/722
ISO MPEG-1/2 Layer I, Layer II, Layer III
AAC-LC, HE-AACv1 (LC+SBR), HE-AACv2(LC+SBR+PS), AAC-LD, AAC-ELD
Opus
CSR aptX Enhanced
TM
16/24-bit
Power
Status
Network
Error
Off: IQOYA is not
connected to the mains
Green: IQOYA is started Orange: IQOYA is
connected to the mains but not started.
Green: No issue Red: temperature or fan
alarm
Green:Ok Orange: No connection
detected on one of the two configured Eth ports. Red: No connection detected on all the configured Eth ports.
Off: No error Red: Audio engine error
IQOYA *SERV/LINK audio algorithms
Physical interfaces
3.1. IQOYA *SERV/LINK Front Panel
IQOYA *SERV/LINK user manual
3.1.1. LEDs
3.1.2. LCD display and keypad
Cancel settings
Confirm settings
Go to previous menu
10
Go to next menu
Go to previous item of current menu
Go to next item of current menu
3.1.3. Navigating menus on LCD display
IQOYA *SERV/LINK user manual
11
IQOYA *SERV/LINK user manual
3.2. IQOYA*SERV/LINK Back Panel
3.2.1. Back panel for analog & AES/EBU version, and AES/EBU versions
Note: IQOYA *SERV/LINK 881, 882, and 16161 do not feature connector “Audio I/O Port 2”.
3.2.2. Back panel for MADI versions
3.2.3. Back panel for AES67 versions
3.2.4. Back panel for AES67/MADI versions
3.2.5. Optional -48VDC power supply
IQOYA *SERVLINK is available with hot swappable redundant -48VDC power supply units.
12
IQOYA *SERV/LINK user manual
4. IQOYA *SERV/LINK working principle
IQOYA *SERV/LINK is a multi-channel IP audio codec. It allows at the same time:
Encoding the incoming signals and streaming them over IP,
Decoding IP audio streams to output channels
Transcoding incoming IP audio streams The number of audio inputs and outputs of the codec is defined by the licence (for instance *SERV/LINK 16161 features 16 mono inputs and outputs). The number of audio channels to be transcoded from the input streams is also defined by the licence (audio buses).
Schematic diagram of IQOYA *SERV/LINK
4.1. Audio inputs and outputs
The audio inputs receive the audio signals to be encoded. They can be analog, AES/EBU, MADI, or RAVENNA / AES67. Each source can be encoded several times at different formats, and streamed to several destinations.
13
IQOYA *SERV/LINK user manual
Audio samples decoded by *SERV/LINK are played to the selected audio outputs. Audio outputs can be analog, AES/EBU, MADI, or RAVENNA / AES67 . In case of an IQOYA *SERV/LINK that features both analog and digital outputs (for instance *SERV/LINK 882), the decoded audio signal is available on both the analog and AES/EBU outputs. Note that decoded audio samples can also be sent to internal audio buses, and audio buses can also be sources to be encoded. See paragraph 4.4 below.
4.2. Programs
On the encoding section of IQOYA *SERV/LINK, a program is the encoding of one or several audio inputs. A program is then defined by the following parameters:
the audio mode: mono, stereo, multi-channel.
the audio input(s) that receive the signal to be encoded. The number of inputs is given by the audio mode.
They are consecutive inputs for stereo and multi-channel modes.
the encoding format: algorithm, bitrate, sampling frequency.
On the decoding part of IQOYA *SERV/LINK, a program is the decoding of an audio source to the audio outputs. A program can be composed of three decoding priorities, with automatic switching from a priority to another in case the audio source is lost. Audio sources of the decoding priorities can be an RTP stream (raw RTP), an HTTP stream (Icecast/Shoutcast), audio inputs, sound files or playlists stored locally.
4.3. IP services
IP services are the way programs are streamed over the IP network. An IP service can include one audio program, or several multiplexed audio programs (case of MPEG-TS MPTS encapsulation). When IQOYA streams, an IP service can be sent to one IP destination (unicast or multicast), or several IP destinations (multi-unicast or multi-multicast). The main parameters that define an IP service are:
the streaming protocol: RTP, UDP, HTTP
the encapsulation: raw (no encapsulation), MPEG-TS
the audio program(s) included in the service: one program in case of raw or MPEG-TS SPTS transport;
several programs in case of MPEG-TS MPTS transport
the FEC scheme (IP data redundancy)
the destination IP address and port. Several destination IP addresses and ports can be declared
(multi-unicast / multi-multicast). When IQOYA decodes, it listens to IP services and unpacks the IP frames in order to extract and decode the audio contents.
4.4. Audio buses
The audio buses serve for transcoding IP audio streams. An audio bus can be selected as the output of one or several output programs. In case several output programs are connected to the same internal bus, the bus mixes the audio from the different programs. Note that an output program can be simultaneously connected to an audio output and an internal bus.
14
IQOYA *SERV/LINK user manual
An audio bus can also be selected as the audio source of an input program (like an audio input), so that it can be streamed as an IP Service.
5. INSTALLATION
5.1. Grounding the IQOYA *SERV/LINK
Attach a ground wire to the chassis (ideally the ground wire has a ring terminal). Connect the other end of the ground wire to a good electrical ground point. Once IQOYA is installed and properly grounded, you can connect the Eth ports and audio I/Os as required for your installation.
5.2. Connecting the audio I/Os and synchronization clocks
In case your IQOYA features analog and/or AES/EBU I/Os, audio connections are available from connectors “Audio Port 1” for *SERV/LINK882 and *SERV/LINK881, and from both connectors “Audio Port 1” and “Audio port 2” for *SERV/LINK16162, 24241 and 32321. Please connect the audio I/Os as follows:
Mono analog input signals 1 to 8 must be connected to inputs 1 to 8 of the breakout cable connected to “Audio I/O port 1”.
Stereo AES/EBU input signals 1 to 4 must be connected to AES/EBU inputs 1 to 4 of the breakout cable connected to“Audio I/O port 1”
Mono analog input signals 9 to 16 must be connected to inputs 1 to 8 of the breakout cable connected to “Audio I/O port 2”
Stereo AES/EBU input signals 5 to 8 must be connected to AES/EBU inputs 1 to 4 of the breakout cable connected to“Audio I/O port 2”
External synchro signal (AES clock, WordClock, Blackburst video reference) must be connected to the corresponding synchro connector of the cable connected to “Audio I/O port 1”.
Warning: In case you use an IQOYA *SERV/LINK 16161, 24241, or 32321 (which are AES/EBU only versions), the WordClock output from “Audio I/O Port 1” must be connected to the WordClock input of “Audio I/O Port 2”.
In case your IQOYA *SERV/LINK features a MADI connection, connect the MADI input fiber to MADI IN connector, and connect the MADI output fiber to MADI OUT connector. Connect the WordClock signal to the WordClock input BNC connector.
5.3. Connecting IQOYA *SERV/LINK to the network
We recommend that the first connection to the IQOYA codec is done on a LAN. The default IP addresses of IQOYA *SERV/LINK Eth ports are:
Eth0: 192.168.0.100
Eth1: 192.168.1.100
15
IQOYA *SERV/LINK user manual
In case you do not know the IP addresses of the IQOYA *SERV/LINK unit you want to connect to, you can read its IP addresses from the front panel (see paragraph “LCD display and keypad”).
Make sure all other devices connected to this LAN are in the same subnet and have different IP addresses (this includes the PC from which you will connect to the IQOYA codec to configure).
5.4. Powering up IQOYA *SERV/LINK
It is recommended to establish all connections before powering the device up. IQOYA *SERV/LINK features two hot swappable redundant power supply units. It is recommended to connect the two power cords. However, only one cord may be used. IQOYA *SERV/LINK starts as soon as it is connected to the mains.
Using only one power supply unit triggers the buzzer of the power supply units. Connecting the second PSU stops the buzzer. In case the second PSU is not used, stop the buzzer by pressing the red button labelled “R.A” on the back panel. Note that this does not turn off the “Error” LED on the front panel and the PSU alarm on the LCD and WEB GUI.
5.5. Steps to follow to configure IQOYA *SERV/LINK
Set the global parameters of your IQOYA *SERV/LINK If IQOYA is used for encoding:
Adjust the parameters of the audio inputs
Declare the programs
Declare the IP services to be streamed over IP
Note that one program can be used by only one IP service.
If IQOYA is used for decoding:
Adjust the parameters of the audio outputs
Declare the IP services to be received from the network
Declare the programs to be decoded from the received IP services
Check the statuses and metrics on the output programs.
If IQOYA is used for transcoding:
16
IQOYA *SERV/LINK user manual
Declare the IP services to be received from the network
Declare the programs to be decoded from the received IP services, and assign them to internal audio buses.
Declare the input programs (select audio buses as the sources of these input programs)
Declare the IP services to be streamed over IP
Check the statuses and metrics on the output programs.
6. Note that IQOYA *LINK can simultaneously encode, decode, and transcode.
17
IQOYA *SERV/LINK user manual
7. Accessing IQOYA *SERV/LINK WEB pages
From a WEB browser, connect to the IQOYA *SERV/LINK WEB pages:
for a network connection through Eth0 port, enter https://192.168.0.100 (this is the default IP address of Eth0).
for a network connection through Eth1 port, enter https://192.168.1.100 (this is the default IP address of Eth1).
The WEB browser displays a message about security certificate. Select the option that allows to continue with this WEB server. Enter the requested username and password. The default administrator login is: username = iqoya password = iqoya
IQOYA *SERV/LINK supports three categories of users: Administrator, User, Read only
“Administrator” category A user from the “Administrator” category has all the access rights on the WEB pages. The login to the embedded WEB server as “Administrator” is:
- username: iqoya
- default password: iqoya Password can only be modified when logged as Administrator.
“User” category A user from the “User” category has limited access rights. “Write” access is limited to the audio parameters (audio format, source/target IP address and UDP port). The login to the embedded WEB server as “User” is:
- username: user
- default password: user Password can only be modified when logged as Administrator. Old password must be entered before entering the new one.
“Read-only” category A user from the Read-only category only has “Read” access rights. He cannot modify a single parameter of the codec. The login to the embedded WEB server as “Read-only” is:
- username: guest
- default password: guest Password can only be modified when logged as Administrator. Old password must be entered before entering the new one.
Once the login has passed, the “Properties” WEB page is displayed. This is the home page.
18
IQOYA *SERV/LINK user manual
Icon
Category
Description
Home page
Displays the properties of the unit as well as its software options
Preferences
Global parameters of the unit.
Audio I/Os
Audio inputs and outputs parameter settings: name, type selection, audio level adjustment, vu-meters)
Encoders
Settings of programs (encodings of audio inputs) and IP services (streaming of programs).
8. Configuration from the WEB pages
Click on the “value” field of a parameter to enter the edit mode. The background colour of all the parameters that can be modified becomes white. Select/enter the appropriate values for the parameters of the page, and click on “Apply” to confirm the settings, or “Cancel to ignore the changes.
9. WEB pages organization
The WEB pages are organized in categories which are always accessible from the left side of the WEB pages.
19
Decoders
Settings of IP services to be received, and associated audio programs to be decoded to the outputs.
Status
Display the status of all the encoders and decoders, as well as the alarms.
Help
Click on to display all the availables menus.
Move the mouse pointer above the menus to display the submenus. Click on a sub-menu to display the corresponding page.
9.1. “Preferences” category of menus
IQOYA *SERV/LINK user manual
20
9.1.1. Preferences -> System
Parameter
Read/Write
Meaning
Hostname
R / W
Logical name given to the device on the network.
Device Name
R / W
Name given to the equipment
Localization
R / W
Language
Serial number
R
Serial number of the unit. This number is set in factory and cannot be changed.
Firmware version
R
Version of the firmware running on the unit. The firmware can be update.
Date
R / W
Date and time of the unit.
Platform ID
R
Identifier of the unit. this number is required for applying firmware options.
Mono audio I/O channels
R
Number of mono audio inputs and outputs allowed by the license.
Mono audio bus channels
R
Number of mono channels allocated for the buses and allowed by the license. Buses are used for transcoding.
9.1.1.1. Preferences -> System -> Properties
IQOYA *SERV/LINK user manual
21
IQOYA *SERV/LINK user manual
9.1.1.2. Preferences -> System -> Audio Clock
This page allows defining the *SERV/LINK sampling clock source .
For a *SERV/LINK with AES/EBU I/Os, or both analog and AES/EBU I/Os, clock source can be:
internal: on-board clock
extracted from an AES/EBU input (AES In x - where x is the number of the AES/EBU input)
AES Sync: AES11 synchro input
Word clock input
For a *SERV/LINK with MADI I/Os clock source can be:
internal: on-board clock
MADI
Word clock input
Click on the “Device clock” field to selected the clock source.
Click on “Apply” to confirm your choice.
9.1.1.3. Preferences -> System -> Audio setup
This page allows setting the global audio parameters of IQOYA *SERV/LINK: sampling frequency, decoder backup switching criteria, silence detection on the audio inputs.
22
Loading...