digicon catrax fit Product Manual

Product manual
Copyright– Digicon S.A.
Electronic Control for Mechanics – 2014
All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, translated into any language or computer language in any electronic, magnetic, optical, chemical, manual way, or otherwise, without the express written permission from Digicon S.A.
Manual code: 069.31.201
English - Revision: 02
This manual was elaborated by: Digicon S.A. Electronic Control for Mechanics
Documentation Sector - EDS
Contents
1. Important instructions .........................................................................05
2. Orientations .......................................................................................06
3. Introduction .......................................................................................06
4. Features of atrax FitC ...........................................................................07
4.1 atrax Fit OperationC ...........................................................................08
5. Installation/Assembling Catrax Fit .........................................................09
5.1 Unboxing .........................................................................................09
5.2 Floor drilling .....................................................................................10
5.3 Colum fixation ..................................................................................10
5.4 Assembling the arms .........................................................................11
5.5 Access to Catrax Fit after assembling ....................................................12
5.5.1 Cover ...........................................................................................12
6. Optional items ...................................................................................13
6.1 Pictogram kit ...................................................................................13
6.2 Electric counter kit ............................................................................14
6.3 Power supply ...................................................................................16
6.4 Control board ...................................................................................17
6.4.1 Inputs ..........................................................................................20
6.4.1.1 Connection scheme .....................................................................21
6.4.1.2 Pictogram ..................................................................................21
6.4.1.3 Pictogram's connections ...............................................................21
6.4.2 Configuration of control board – Switch Ds1 .........................................22
6.4.3 Outputs ........................................................................................22
6.4.3.1 Return signals .............................................................................23
6.4.3.2 Electromagnets ...........................................................................23
6.4.3.3 Sound alarm...............................................................................23
6.4.4 Examples of some configurations ......................................................24
6.5 Anti-Panic System .............................................................................25
7. Maintenance ......................................................................................26
7.1 Preventive and corrective routine maintenance .......................................26
7.2 Defects and possible causes ................................................................28
8. Technical characteristics ......................................................................29
8.1 Dimensions ......................................................................................29
8.2 Other information ..............................................................................30
9. Warranty and Technical Assistance .........................................................31
05
1. mportant nstructionsI i
You can see, below, the symbols that will appear in this manual, signaling important moments. It is essential to pay attention to them.
TIP: Indicates something Digicon considers important.
CAUTION: Indicates a moment of extreme caution when
handling the equipment/product
ATTENTION: Indicates a moment when your observation skills should be extremely productive.
INFORMATION: Presents interesting facts about the purchased product.
QR CODE: Presents additional information or links with more details about the presented text
.
2. Orientations
Read the information and instructions of this manual carefully, before using the
product. This ensures the correct use of the equipment and maximum use of its technical features as well as a prolonged service life.
This product does not present sealing against the rain, that is, it is designed to be
used indoors.
Keep this manual for future consultations.Digicon reserves its right to alter its products at any moment to adapt them to more
recent technical advancements.
Digicon maintains its right to alter the information contained in this manual without
previous
notice.
Digicon does not provide any contractual warranty concerning the information in this
manual, and cannot be held responsible for errors it may contain and problems due to its use.
The information contained in this manual is exclusive property of Digicon and is
protected by copyright laws.
This manual cannot be reproduced, photocopied or translated, in its entirety or in
part, into any kind of medium, without Digicon's written consent.
3. Introduction
Following a new technological concept focused on solidity and reliability and counting with innovative design elements, with color variety and widely curved lines, Digicon has launched the line C Fit.atrax
C Fit serves most technologies of access control currently available at companies,atrax condominiums, clubs, and gyms. This manual presents a detailed description of the components and working of C Fit.atrax To see our complete catalogue, visit www.digicon.com.br
4. atraxFeatures of C Fit
C Fit, an access controller in the model mini turnstile (column type), presents threeatrax bidirectional, equidistant arms at 120 degrees with brushed stainless steel (AISI 304) finishing.
The column can present external 1020 carbon steel finishing with electrostatic painting in black or grey epoxy powder.
It has reinforced structure, fully rounded corners, and non-exposed screws, offering space and comfort for any access control solution. Standard holes for the fixation of additional electronic boards. Moreover, the clients, according to their needs, can add additional holes. Access to the support is done through a key with secret, whose removal and insertion are extremely easy. A plastic cover and a stainless steel sheet compose the upper panel. The cover, made of injected plastic, can be purchased in the colors green, burgundy, or black or in any other color desired, on demand. Optionally, the cover can present a slot for the reading of magnetic cards/badges and barcodes. The upper cover in stainless steel allows easy configuration and low-cost customization of the product. The sheet can also present slots for optional items, such as pictogram, display kit, or a combination of these items. Besides compatibility with most available technologies, Digicon can provide the following optional items: pictogram kit, counter kit, power supply, and control board.
INFORMATION: The turning of the turnstile can be blocked only with the activation of the electromagnets. If the turnstile has no power supply, the turning mechanism remains free.
4.1 C Fit Operationatrax
In the basic mechanism, C Fit has a two-dimensional rotation system with twoatrax 12 V electromagnets for activating the locks and two optical sensors that can provide the signal for the activation of the electromagnets and passage clearance. In the electronic model, which includes a microprocessor control board (optional), a signal enabling passage is sent through one of the inputs, depending on the passage direction. If this signal is recognized, the equipment will allow the turning of the arm of C Fit. After half of the turning is complete (60 degrees), a 400 millisecondsatrax returning signal will be sent, informing the passage direction. After the signal, the arm cannot be returned to the previous position. Depending on the C Fit model and configuration, if the passage is forced withoutatrax the enabling signal, an electromagnet will be activated to prevent turn. In addition, the equipment can emit a signal for a sound alarm and/or the exhibition of a red X on the upper panel display (models with pictogram). In this case, a return signal will be sent, indicating that the turnstile was forced, informing the direction of turn.
-Mechanisms of C Fit:atrax
5. Installing/Assembling C Fitatrax
5.1 Unboxing
As the items inside the package can vary (depending on the client's requests), it is important to perform a cautious visual inspection before installing and assembling the turnstile. A checklist that works as a guide during inspection accompanies all Digicon packages.
See below the parts that can compose C Fit:atrax
ATTENTION: To avoid losses, the screws and the wrenches used for assembling the C Fit are attached to the box containing the arms.atrax Before discarding the packing materials (cardboard and plastics), make sure all the items in the checklist are accounted for.
Left to right direction
Right to left direction
Arm
Lock
Cables passage
Steel sheet
Plastic co
ver kit
Column
5.2 Floor drilling
Before installing C Fit, check:atrax
-If there will be enough space.
-The place chosen for the installation.
-If there is a power source or electric socket nearby (ducts for connection);
-if the place chosen is adequate for the installation of the access controller (indoors);
-if there will be enough space (minimum 5 cm) between the rear of the C Fitatrax column and the wall. This space is important in order to provide access to the upper panel and plug's locks for the cables passage.
-if there will be enough space for the arms after C Fit is assembled.atrax
-If the floor is in conditions to receive anchor bolts (minimum of 4 cm of FCK15 M.P.A. concrete or equivalent).
5.3 Colum fixation
To fixate the column to the floor, observe the following steps:
1. drill the floor with 3/8” drills (then use a 12mm or the ½” drill). Make 4 external holes, according to the measures indicated in the image below:
ATTENTION: Since the C Fit's installation requires floor drilling, itatrax is important that the location be chosen carefully.
Measures in millimeters and inches.
120 (4,724")
54
(2,125")
51 (2,007")
230 (9,055")
ATTENTION: in the central slot, destined to the passage of cables, it is necessary to measure the cables according to the opening's size.
TIP: As an optional item, Digicon can provide a steel template for the fixation of Catrax Fit, containing the exact demarcations of the necessary holes.
2. Clean the holes, removing any debris from drilling.
3. Place the external part of the bolts in the holes. Leave about 25mm of the bolt out of the hole.
4. Position the column and fasten it to the floor with the four screws that accompany the bolts. Use a flex-head socket wrench with ¾'' or an articulated socket wrench.
5.4 Assembling the arms
After drilling the floor and assembling the column, it is possible to assemble the arms and
plastic covers. The image below shows the specific parts of C Fit's arms and upper frontalatrax cover.
TIP: We recommend the bolts by the brand Tecnart, model AF38110, 3/8x4''.
Screw M3x8
Screw M3x16
Upper plastic
cover
Flat washer M3
Arm
*Screwsaccess cover *Screw Allen M6x20 *Lock washer M6