1. Normal Keys Function........................................................................................................................................... 2
2. Preset Keys Function in Programming Mode .................................................................................................... 4
Table of Characters Code................................................................................................................................................. 6
1. Procedures of Password Setting............................................................................................................................ 8
2. Use Password .........................................................................................................................................................11
General Explanation........................................................................................................................................................16
Department Files .............................................................................................................................................................17
1. Program Department File ....................................................................................................................................17
2. Print Department File...........................................................................................................................................19
3. Delete Department File........................................................................................................................................20
Main Group Files.............................................................................................................................................................21
1. Program Main Group File....................................................................................................................................21
2. Print Main Group File ..........................................................................................................................................23
3. Delete Main Group File .......................................................................................................................................24
PLU Item Selection .........................................................................................................................................................25
PLU Programming...........................................................................................................................................................27
1. Program PLU File .................................................................................................................................................28
2. PLU [COPY] Function......................................................................................................................................... 65
3. Print PLU File........................................................................................................................................................66
4. Delete PLU File .....................................................................................................................................................68
Label Format List.............................................................................................................................................................69
1. EAN Barcode Format ..........................................................................................................................................70
1. PLU Assignment....................................................................................................................................................75
3. Function Key Assignment....................................................................................................................................79
Shop Name File................................................................................................................................................................ 91
1. Program Shop Name File.....................................................................................................................................91
2. Print Shop Name File ...........................................................................................................................................93
3. Delete Shop Name File......................................................................................................................................... 94
1. Program Advertisement File................................................................................................................................95
Date & Time Setting......................................................................................................................................................103
Special Message File ......................................................................................................................................................104
1. Program Special Message File............................................................................................................................104
2. Print Special Message File ..................................................................................................................................106
3. Delete Special Message File ...............................................................................................................................107
1. Program Ingredient File......................................................................................................................................108
Text File...........................................................................................................................................................................113
1. Program Text File................................................................................................................................................113
2. Print Text File ......................................................................................................................................................115
3. Delete Text File....................................................................................................................................................116
Free Format File.............................................................................................................................................................117
1. General Information ...........................................................................................................................................117
2. Print Area, Print Position and Print Angles ....................................................................................................118
3. Free Format Entry...............................................................................................................................................120
4. Test Printing.........................................................................................................................................................122
5. Item Data Position ..............................................................................................................................................123
6. Print Free Format File ........................................................................................................................................135
7. Delete Free Format File .....................................................................................................................................136
8. Sample of program a format by modifying the existing format...................................................................137
Place File .........................................................................................................................................................................143
1. Program Place File...............................................................................................................................................143
2. Print Place File .....................................................................................................................................................145
3. Delete Place File ..................................................................................................................................................146
Logo File .........................................................................................................................................................................147
SM-300 Operation Manual (Advance)
1. Pre-programming Logo Data ............................................................................................................................147
2. Program Display & Keys Function ..................................................................................................................148
4. Program Logo File...............................................................................................................................................150
5. Print Logo File .....................................................................................................................................................152
6. Delete Logo File ..................................................................................................................................................153
1. Program Tax File.................................................................................................................................................154
Country File ....................................................................................................................................................................163
1. Program Country File .........................................................................................................................................163
2. Print Country File................................................................................................................................................164
3. Delete Country File.............................................................................................................................................165
Cutting Hall File.............................................................................................................................................................166
1. Program Cutting Hall File..................................................................................................................................166
2. Print Cutting Hall File.........................................................................................................................................167
3. Delete Cutting Hall File......................................................................................................................................168
Slaughter House File .....................................................................................................................................................169
1. Program Slaughter House File...........................................................................................................................169
2. Print Slaughter House File .................................................................................................................................170
3. Delete Slaughter House File ..............................................................................................................................171
1. Program Kind File...............................................................................................................................................172
1. Program Category File........................................................................................................................................174
1. Program Breed File .............................................................................................................................................176
1. Program Traceability File ...................................................................................................................................180
Host Name Programming ............................................................................................................................................188
Credit Name Programming..........................................................................................................................................192
PRESET FUNCTION KEYS.............................................................................200
[ADVERTISEMENT] Function Key........................................................................................................................200
[PRICE DISCOUNT] Function Key.........................................................................................................................202
[PACK DATE] Function Key.....................................................................................................................................216
[- PACK DATE] Function Key ..................................................................................................................................218
[SELL-BY-DATE] Function Key...............................................................................................................................220
[QUANTITY SYMBOL] Function key.....................................................................................................................223
[QUANTITY] Function Key.......................................................................................................................................225
[UNIT PRICE CHANGE] Function key..................................................................................................................227
[REFUND] Function Key............................................................................................................................................229
[SHOP NAME] Function key .....................................................................................................................................231
[LOGO] Function Key.................................................................................................................................................232
[SELECT PRINT ITEM] Function key....................................................................................................................233
[SUB TOTAL] & [GRAND TOTAL] Function Key .............................................................................................235
[PACK QUANTITY] Function Key..........................................................................................................................237
[PRICE MARKDOWN] Function Key ....................................................................................................................239
[UNIT PRICE STORE] Function Key .....................................................................................................................254
[PLACE] Function Key ................................................................................................................................................256
[LABEL FORMAT 1] Function key ..........................................................................................................................259
SM-300 Operation Manual (Advance)
[LABEL FORMAT 2] Function key ..........................................................................................................................261
[PREPACK NON ADD] Function Key...................................................................................................................264
[MAIN GROUP NUMBER] Function Key.............................................................................................................267
[MANUAL WEIGHT] Function key.........................................................................................................................269
[ITEM CODE] Function Key.....................................................................................................................................272
[SWITCH KEY] Function Key...................................................................................................................................273
[REFERENCE PLU] Function Key..........................................................................................................................275
[PRINT KEY] Function Key ......................................................................................................................................276
[PLU REPEAT] Function Key ...................................................................................................................................277
[FLAG CODE] Function Key ....................................................................................................................................278
[CASH DRAWER OPEN] Function Key ................................................................................................................280
[TAX INFORMATION] Function Key ...................................................................................................................281
[UNIT PRICE OVERRIDE PASSWORD] Function Key...................................................................................283
[1/2 PRICE KEY] Function key ................................................................................................................................285
[CHEQUE TENDER KEY] Function Key.............................................................................................................286
[VOUCHER TENDER KEY] Function Key..........................................................................................................288
[CREDIT KEY] Function Key...................................................................................................................................289
[DIRECT DISCOUNT] Function Key.....................................................................................................................290
[INGREDIENT] Function key...................................................................................................................................292
[BATCH FILE PRINT] Function Key......................................................................................................................294
[BORN COUNTRY] Function Key ..........................................................................................................................296
[FATTEN COUNTRY] Function Key .....................................................................................................................298
[SLAUGHTER HOUSE] Function Key...................................................................................................................300
[CUTTING HALL] Function Key.............................................................................................................................303
[REFERENCE NUMBER] Function Key ...............................................................................................................305
1. DATE (SWEDISH)............................................................................................................................................305
[ORIGIN COUNTRY] Function Key.......................................................................................................................308
[TRACEABILITY SET] Function Key.....................................................................................................................310
[TRACEABILITY NO] Function Key......................................................................................................................317
[TRACEABILITY UPDATE] Function Key...........................................................................................................319
[TRACEABILITY CLEAR] Function Key ..............................................................................................................320
[LABEL / RECEIPT SWITCH KEY] Function Key............................................................................................321
[INVENTORY] Function Key ...................................................................................................................................322
[SPECIAL MESSAGE] Function key........................................................................................................................327
[DATE PRINT] Function Key ...................................................................................................................................329
[CASH IN or OUT] Function Key.............................................................................................................................330
[PRINT SELL-BY-DATE] Function Key ................................................................................................................331
[PRINT PLU TOTAL REPORT] Function Key ....................................................................................................332
[PRINT RECEIPT] Function Key.............................................................................................................................334
[LABEL PRINT WITHOUT REPORT] Function Key........................................................................................335
Supporting features contained in this document might be different for individual country specification.
Key Panel
Bench Type
Pole Type
1
SM-300 Operation Manual (Advance)
Key Functions
1. Normal Keys Function
Please refer to the followings for the detail explanation about each key function in Programming Mode.
ON/OFF KEY
or
NUMERIC KEYS
to
TARE KEY
CLEAR KEY
RE-ZERO KEY
or
PREPACK KEY
Turn display "ON" or "OFF".
Enter numeric data.
Set or Clear Tare value.
Select "NO" in S and Z Mode.
Item test print in S Mode.
For Back space or Clear numeric value.
Select "YES" in S and Z Mode.
Reset weight to ZERO.
Switch Manual mode and Pre-pack mode alternatively.
or
CHANGE KEY
or
MULTIPLLE KEY
or
(The mode status will be indicated in the P and M indicator.)
▪P - PRE-PACK MODE ▪M - MANUAL MODE
Calculate the Changed Amount.
Escape the Programming screen without saving data in S Mode.
Register the number of Non-Weight products.
Select programming item such as PLU data, Shop Name in S Mode.
Select Report Type in X Mode.
Select Data Transaction Type in Z Mode.
2
CLERK KEY
SM-300 Operation Manual (Advance)
VOID KEY
or
PLU KEY
or
FEED KEY
or
PRINT KEY
or
MODE SELECT KEY
Accumulate the Total Price.
Correct the sales data.
Call up PLU data in R Mode.
Store the programmed data in S Mode.
Feed Label or Receipt paper
Print out Label or Receipt.
Five Modes can be selected using this key.
or
•Indicator R - REGISTRATION MODE (All the sales transactions
are performed.)
• Indicator X - CHECK MODE (Printing out and sales report.)
• Indicator S - PROGRAM MODE (Programming preset data, such
as products, data, shop name, etc.)
• Indicator Z - TOTAL MODE (Clear sales data stored.)
• Indicator RXSZ (
Blink
) - Password Setting Mode (Set PASS
WORD for X, S, Z mode, set PASSWORD for PASSWORD MODE
when all indicators(R, X, S, Z) blink)
3
SM-300 Operation Manual (Advance)
2. Preset Keys Function in Programming Mode
Please refer to the followings for the detail explanation about each Preset key function in Programming
Mode.
Call up Preset data such as PLU Data or Function Data in Reg. Mode.
to
Enter Alphabetic data in S Mode (Program Mode).
Enter Report Type in X Mode (Report Mode).
Note 1: The following Preset Keys are used in entering Alphabetic for POLE TYPE.
Select Parameter Data such as Barcode type and print Label Format.
or
Move the cursor Change the entry to Left or Right.
Switch INSERT or OVERWRITE alternatively.
Switch Cap / Lower case.
Change Font size.
Backspace.
Delete the Data.
Select Code types (Preset key, ASCII Code, Teraoka Code, etc.) for enter
Commodity Descriptions, Commercial Message, and Shop Name etc.
*Please refer to Table of Characters Code.
4
SM-300 Operation Manual (Advance)
Note 2: The following Preset Keys are used for entering Character Parameter or Text Data for BENCH TYPE
when SPEC 274 set to 1 "OLD".
Select Parameter Data such as Barcode type and print Label Format.
or
Move the cursor Change the entry to Left or Right.
Switch INSERT or OVERWRITE alternatively.
Change Font size.
Backspace.
Delete the Data.
Select Code types (ASCII Code, Teraoka Code, etc.) for enter
Commodity Descriptions, Commercial Message, and Shop Name etc.
*Please refer to Table of Characters Code.
Note 3: The following Preset Keys are used for entering Character Parameter or Text Data for BENCH TYPE
when SPEC 274 set to 0 "NEW". (Allow enter A ~ Z by pressing preset keys and 0 ~ 9 by Numeric
Keypad.)
Select Parameter Data such as Barcode type and print Label Format.
or
Move the cursor Change the entry to Left or Right.
Switch INSERT or OVERWRITE alternatively.
Note: Only allow switch in ASCII Code or TERAOKA Code entries mode.
Change Font size.
Switch Cap / Lower case.
Backspace.
Select Code types (ASCII Code, Teraoka Code, etc.) for enter
Commodity Descriptions, Commercial Message, and Shop Name etc.
*Please refer to Table of Characters Code.
5
SM-300 Operation Manual (Advance)
Table of Characters Code
1. ASCII Code
The table shown below is the common use of characters of ASCII code in HEX value. Please enter the
hex value when entering commodity name, advertisement, shop name, clerk name, special message,
ingredient, text etc. when using the SM 300.
K L J I
18 19 1A 1B
SP ! " # $ % & ' ( )
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F
0 1 2 3 4 5 6 7 8 9 : ; < = > ?
30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
@ A B C D E F G H I J K L M N O
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F
P Q R S T U V W X Y Z ^ _
50 51 52 53 54 55 56 57 58 59 5A 5E 5F
a b c d e f g h i j k l m n o
61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F
p q r s t u v w x y z
70 71 72 73 74 75 76 77 78 79 7A
½
+ , - . /
Ç ü é â ä à ç ê ë è Ä
80 81 82 83 84 85 87 88 89 8A 8E
É æ Æ ô ö ù Ö Ü £ ƒ
90 91 92 93 94 97 99 9A 9C 9F
á í ó ú ñ Ñ ĔC° ã ∆ ρ
A0 A1 A2 A3 A4 A5 A9 AA AC AD AE AF
Ë ≠ Œ œ
B0 B1 B2 B3 B4 B5 B6 B7 B9 BD
 Ã
C1 C7
½
χ
ĉ Á À Ů Ó
6
SM-300 Operation Manual (Advance)
Ê È Í
D2 D4 D6
βÔ õ Õ Ú
E1 E2 E4 E5 E9
± ≥≤
F1 F2 F3 F4 F5 F6 F8
Left€ Right
§
€
°
Note: For Commodity Name, the small letter cannot print at receipt but will print capital letter.
2. TERAOKA Code
The table shown below is the common use of characters of TERAOKA code in numerical value. Please
enter the numerical value when entering commodity name, advertisement, shop name, clerk name, special
message, ingredient, text etc. when using the SM 300.
Space A B C D E F G H I
00 01 02 03 04 05 06 07 08 09
J K L M N O P Q R S
10 11 12 13 14 15 16 17 18 19
T U V W X Y Z , . -
20 21 22 23 24 25 26 27 28 29
0 1 2 3 4 5 6 7 8 9
30 31 32 33 34 35 36 37 38 39
@ ! ” # $ % & / ( )
40 41 42 43 44 45 46 47 48 49
’ < > + :
½
À Â È Ê
50 58 59 69 72 73 77 78 79 80
É Ô Ç ? → ←
81 82 83 96 97 98
7
SM-300 Operation Manual (Advance)
SETUP
Password Setting
This function is used to set password so only authorized person can access the modes for operation.
Password can be set for the following 4 modes and up to 6 digits can be entered as Password Code. [To
enable this programming mode, please set SPEC 64 to 0 (ALLOW) in advance.]
1) Enter Password Setting Mode from Stand-by Status.
press [PRINT] key again to go to next step (Password setting for S Mode).
*If not necessary to set password for X Mode, just
KEY TO PRESS DISPLAY
¼O
»
NET
X MODE PASSWORD: 0
P
NEW: 0-9 / CLEAR: *
M
X
2) Enter password code (Ex. 111) for Report Mode (X Mode).
KEY TO PRESS DISPLAY
¼O
»
NET
X MODE PASSWORD: 111
P
NEW: 0-9 / CLEAR: *
M
X
Note: To escape without saving the X Mode password setting, press [MODE] key to exit (Back to Stand-by
Status).
3) Save the password code for X Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
S MODE PASSWORD: 0
P
NEW: 0-9 / CLEAR: *
M
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
8
SM-300 Operation Manual (Advance)
Note: If not necessary to set password for S Mode, just press [PRINT] key again to go to next step (Password
setting for Z Mode) or press [MODE] key to Save & Exit from password setting mode.
9
SM-300 Operation Manual (Advance)
4) Enter password code (Ex. 222) for Programming Mode (S Mode) and save it.
KEY TO PRESS DISPLAY
¼O
»
NET
Z MODE PASSWORD: 0
P
NEW: 0-9 / CLEAR: *
M
Z
Note: If not necessary to set password for Z Mode, just press [PRINT] key again to go to next step (Password
setting for Password Mode of Password) or press [MODE] key to Save & Exit from password setting
mode.
5) Enter password code (Ex. 333) for Total Mode (Z Mode) and save it.
KEY TO PRESS DISPLAY
¼O
»
NET
PWD MD PASSWORD: 0
P
NEW: 0-9 / CLEAR: *
M
R
S
X
Z
6) Enter password code (Ex. 444) for Password Mode and save it.
for Password Mode, press [PRINT] key to save & exit.
*If not necessary to set password
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
PWD MD PASSWORD: 444
P
NEW: 0-9 / CLEAR: *
M
W
»
0.000 0.000.00
P
0.000
M
W
NET
¼O
NET
R
S
X
Z
R
AM
CH
PE
AM
CH
PE
10
SM-300 Operation Manual (Advance)
2. Use Password
For example:
1) Stand-by Status.
KEY TO PRESS DISPLAY
2) Enter programming Mode.
KEY TO PRESS DISPLAY
3) Enter Password Code (Ex. 222) for Programming Mode.
To enter Programming Mode.
¼O
W
»
NET
P
M
W
*Press [RE-ZERO] key with in 2 seconds after pressing [MODE] key.
¼O
»
NET
P
M
0.000 0.000.00
0.000
ENTER S MODE PASSWORD
PASSWORD:
R
S
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
ENTER S MODE PASSWORD
P
PASSWORD: ---
M
NET
4) Enter Programming Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU PROGRAMMING
P
ENTER PLU # 0
M
Note: A message "PWD NG" appears on the display for a second if enter wrong Password Code.
S
S
AM
CH
PE
AM
CH
PE
11
SM-300 Operation Manual (Advance)
3. Delete Password Code
For example:
1) Enter Password Setting Mode from Stand-by Status.
KEY TO PRESS DISPLAY
2) Enter password code (Ex. 444) for Password Mode of Password and entry password setting mode.
KEY TO PRESS DISPLAY
3) Delete password code for Report Mode (X Mode). *
new password you want and then press [PRINT] key to save it.
Delete password code for REPORT MODE (X Mode).
¼O
»
NET
¼O
NET
ENTER PWD MODE PWD
P
PASSWORD:
M
»
X MODE PASSWORD: 0
P
NEW: 0-9 / CLEAR: *
M
If you want to change the password code, enter the
R
S
X
Z
X
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
S MODE PASSWORD: 0
P
NEW: 0-9 / CLEAR: *
M
4) Save the data and exit from password setting mode.
press [PRINT] key to delete its.
*If you want to delete others Mode password code, just
KEY TO PRESS DISPLAY
¼O
W
»
NET
0.000 0.000.00
P
0.000
M
W
S
R
AM
CH
PE
AM
CH
PE
12
SM-300 Operation Manual (Advance)
Closing & Report
This function is used to clear the total data for report printing. The following 6 CLEAR nodes are available.
Key To Press Data File
CLEAR DAILY TRANSACTION
CLEAR MONTHLY TRANSACTION
CLEAR TERM TRANSACTION
*Note: TERM means the period from the last clear transaction to next clear transaction.
CLEAR ALL TRANSACTION (Clearing Daily, Monthly and Term Sales)
CLEAR TRACEABILITY TRANSACTION
*Note: To enable this Moe, SPEC 278 must set to YES.
CLEAR INVENTORY TRANSACTION
Note: By setting SPEC 65 set to 1, Store Summary Report will be printed before clearing Daily or Term
transaction data.
There are two ways to select the Transaction type by using different keys such as:
• Enter the Numeric key and then press [X] key.
• Press [X] key to select.
(Data processing: Daily Data J Monthly Data J Term Data J All Data J Traceability Report J
Inventory Report J Daily Data).
Transaction example:
To Clear TERM Transaction.
1) Enter Total Mode (“Z” Mode) from Stand-by-Status (REG. Mode).
seconds after pressing [MODE] key.
KEY TO PRESS DISPLAY
¼O
»
NET
* Press [RE-ZERO] key within two
TO CLEAR DAILY TRANS
P
PRESS PRINT KEY
M
13
Z
AM
CH
PE
SM-300 Operation Manual (Advance)
2) Enter Clear TERM Transaction mode.
KEY TO PRESS DISPLAY
¼O
»
TO CLEAR TERM TRANS
P
PRESS PRINT KEY
M
or
NET
3) Enter Clearing Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
CLEAR TERM TRANS?
P
PRESS: C(YES) / T(NO)
M
4) Clear the Transaction.
*If you want to cancel clearing transaction, press [TARE] key.
Z
Z
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
TO CLEAR TERM TRANS
P
PRESS PRINT KEY
M
5) Return to Stand-by Status.
KEY TO PRESS DISPLAY
¼O
W
»
0.000 0.000.00
P
0.000
M
W
NET
Z
R
AM
CH
PE
AM
CH
PE
14
SM-300 Operation Manual (Advance)
PROGRAM MODE
Programmable Files
In Programming Mode, there are two ways to select the Programming File by using different keys such as:
• Enter the Number and then press [X] key.
• Press [X] key or [−] key to select the Data File.
The files listed below can be programmed in PROGRAM Mode (S Mode).
Key To Press Data files Key To PressData files
[1] [X] PLU Programming[3] [1] [X] PLU Call Range Programming
[2] [X]
[3] [X]
[4] [X]
[5] [X]
[6] [X]
[7] [X]
[8] [X]
[9] [X]
[1] [0] [X]
[1] [1] [X]
[1] [2] [X]
Department Programming
Main Group Programming
Key Assignment
Shop Name Programming
Advertisement Programming
Clerk Programming
Date and Time Setting
Special Message Programming
Ingredients Programming
Text Programming
Free Format Programming
[3] [2] [X]
[3] [3] [X]
[3] [4] [X]
[3] [5] [X]
[3] [6] [X]
[3] [7] [X]
[3] [8] [X]
[3] [9] [X]
[4] [0] [X]
[4] [1] [X]
[4] [3] [X]
Secure Price Threshold
Job Batch Programming
Country Name Programming.
Cutting Hall Programming
Slaughter House Programming.
Traceability Programming
Host Name Programming
Payment Key Programming
Credit Name Programming
Cash Drawer (Cash IN / OUT)
Access Privileges Pigment
[1] [5] [X]
[1] [7] [X]
[1] [8] [X]
[1] [9] [X]
[2] [0] [X]
Place Programming
Logo Programming
Tax Programming
PLU Item Selection
Memory Status
15
[4] [6] [X]
[4] [7] [X]
[4] [8] [X]
[4] [9] [X]
Flexi Barcode programming
Kind File Programming
Category File Programming
Breed File Programming
SM-300 Operation Manual (Advance)
General Explanation
DEPARTMENT, MAIN GROUP and PLU files are connected as shown below. By the following linking
method, more detail and concrete information on sales transaction or pre-pack data can be got by printing
various reports.
DEPARTMENT FILE
DEPARTMENT file is the largest category whose items are like MEAT, FISH, VEGETABLE or
DELICATESSEN etc.
MAIN GROUP FILE
MAIN GROUP file is the middle category including items such as BEEF, PORK, CHICKEN, etc. You
can link a Main Group to a Department in the Main Group file. Tax Number can be assigned to a Main
Group. The assigned Tax Number will apply for all the PLU’s assigned to the Main Group.
PLU FILE
PLU File is the smallest category including items such as BEEF SLICE, BEEF SHOULDER and
BEEF SIRLOIN. You can link the PLU to a Main Group in the PLU programming file.
16
SM-300 Operation Manual (Advance)
Department Files
Department file is used for categorizing Main Groups. Department Number between 1 ~ 99 are available
for programming. The Main Groupsthat are not linked to any Department will be assigned to
Department Number 97 automatically. Maximum 16 characters per file are available and each with 1 line.
Note:
a) Non-PLU data (weighing items) will be assigned to Department file No.98.
b) Non-PLU data (Non-weighing items) will be assigned to Department file No.99.
c) The Department names programmed are not printed on the label or receipt but are for
reporting.
1. Program Department File
1) Stand-by Status.
KEY TO PRESS DISPLAY
¼O
W
»
NET
0.000 0.000.00
P
0.000
M
W
2) Enter programming Mode.
KEY TO PRESS DISPLAY
¼O
»
PLU PROGRAMMING
P
ENTER PLU # 0
M
NET
3) Select Department programming mode.
KEY TO PRESS DISPLAY
¼O
»
DEPARTMENT
NET
or
PROGRAMMING
P
ENTER DEPARTMENT # 0
M
R
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
17
SM-300 Operation Manual (Advance)
4) Enter new Department Number (Ex. 1) programming mode. *For edit, enter existing Dept. Number.
KEY TO PRESS DISPLAY
¼O
»
NET
DEPT # 01 P:KEY
P
CHAR 1:
M
S
AM
CH
PE
5) Enter Department Name (Ex. MEAT) by press the Preset Keys.
KEY TO PRESS DISPLAY
¼O
»
NET
DEPT # 01 P:KEY
P
W
CHAR 5:MEAT
M
S
Note: Please refer to Preset Keys Function in Programming Mode and Table of Characters Code for Department
Name entries by using ASCII Code (A) or TERAOKA Code (T).
AM
CH
PE
6) Save the data.
*If you want to exit without saving data, press [CHANGE] key and then follow by [CLEAR] key.
KEY TO PRESS DISPLAY
¼O
»
DEPARTMENT
NET
PROGRAMMING
P
ENTER DEPARTMENT # 0
M
S
AM
CH
PE
18
SM-300 Operation Manual (Advance)
2. Print Department File
The following operation is used for checking Department Data programmed. The report is printed on
receipt paper and there are two different print types, Full report & Single report. The Full report
includes all the programmed data, and the Single report only includes one data.
Single Report Printing
1) At Department programming mode, enter existing Department Number (Ex. 3) then print out report
*If you want to stop printing, press [FEED] key.
KEY TO PRESS DISPLAY
¼O
»
DEPARTMENT
NET
¼O
»
NET
¼O
»
NET
PROGRAMMING
P
ENTER DEPARTMENT # 3
M
PRINTING ,,,
P
M
DEPARTMENT
PROGRAMMING
P
ENTER DEPARTMENT # 0
M
Full Report Printing
1) At Department programming mode, print out full report.
S
S
S
*If you want to stop printing, press [FEED] key.
AM
CH
PE
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PRINTING ,,,
P
M
DEPARTMENT
PROGRAMMING
P
ENTER DEPARTMENT # 0
M
19
S
S
AM
CH
PE
AM
CH
PE
SM-300 Operation Manual (Advance)
3. Delete Department File
When the MAIN GROUP FILE exists under the Department File, the Department Code data cannot be
deleted. In addition, the Department Code number 97, 98 and 99 cannot be deleted.
1) At Department programming mode, enter existing Department Number (Ex. 3) to be deleted.
KEY TO PRESS DISPLAY
¼O
»
DEPARTMENT
NET
PROGRAMMING
P
ENTER DEPARTMENT # 3
M
2) Enter deleting mode.
KEY TO PRESS DISPLAY
¼O
»
NET
DELETE?
P
PRESS: C(YES) / T(NO)
M
3) Delete Department Number 3.
*If you want to cancel the deletion, press [TARE] key to exit.
S
S
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
DEPARTMENT
NET
PROGRAMMING
P
ENTER DEPARTMENT # 0
M
S
AM
CH
PE
20
SM-300 Operation Manual (Advance)
Main Group Files
Main Group is the middle category and can be assigned to a Department. The Main Group file is used for
categorizing the PLU's. Main Group Number of 1 ~ 999 are available for programming. PLU's that are
not linked to any Main Group Number will be assigned to the Main Group Number 997 automatically.
TAX is assigned to every Main Group. The assigned TAX will apply for all the PLU's assigned to the
Main Group. Up to 250 data can be programmed in Main Group file. Maximum 16 characters per file are
available and each with 1 line.
Note:
a) Non-PLU data of Weighing items will be assigned to main group file No.998.
b) Non-PLU data of Non-weighing items will be assigned to main group file No.999.
c) The Main Group names programmed are not printed on the label or receipt but are for
reporting.
1. Program Main Group File
1) At Programming Mode, select Main Group programming mode and enter new Main Group Number
(Ex. 3) programming mode. *For edit, enter existing Main Group Number.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
MAIN GROUP
PROGRAMMING
P
ENTER MAIN GROUP # 0
M
MAIN GROUP # 003
P
LINKED TO DEPT # 97
M
S
S
2) Enter the existing Department Number (Ex. No.1), if not necessary to change the Department
Number, just press [PRINT] key to enter next step.
KEY TO PRESS DISPLAY
¼O
»
NET
MAIN GROUP # 003
P
TAX # 0
M
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
21
SM-300 Operation Manual (Advance)
3) Enter the existing TAX Number (Ex. No.1), if not necessary to link the Tax Number, press [PRINT]
key to enter next step.
Note: This procedure will skip if SPEC 603 is set to "NO TAX".
KEY TO PRESS DISPLAY
¼O
»
NET
MAIN GROUP # 003
P
TRACEABILITY# 0
M
S
AM
CH
PE
4) Enter existing Traceability Number (Ex. 36), if not necessary to link the Traceability Number, just press
[PRINT] key to enter next step.
Note: This procedure will skip if SPEC 258 is set to "NO".
KEY TO PRESS DISPLAY
¼O
»
NET
MAIN GROUP #003 P:KEY
P
CHAR 1:
M
S
AM
CH
PE
5) Enter Main Group Name as the same procedure as Department Name entry(Ex. BEEF).
KEY TO PRESS DISPLAY
¼O
»
MAIN GROUP #003 P:KEY
P
W
CHAR 5:BEEF
M
NET
6) Save the data.
*If you want to exit without saving data, press [CHANGE] key and then follow by [CLEAR] key.
KEY TO PRESS DISPLAY
¼O
»
MAIN GROUP
NET
PROGRAMMING
P
ENTER MAIN GROUP # 0
M
S
S
AM
CH
PE
AM
CH
PE
22
SM-300 Operation Manual (Advance)
2. Print Main Group File
The following operation is used for checking Main Group Data programmed. The report is printed on
receipt paper and there are two different print types, Full report & Single report. The Full report
includes all the programmed data, and the Single report only includes one data.
Single Report Printing
1) At Main Group programming mode, enter existing Main Group Number (Ex. 3) then print out report
*If you want to stop printing, press [FEED] key.
KEY TO PRESS DISPLAY
¼O
»
MAIN GROUP
NET
¼O
»
NET
¼O
»
NET
PROGRAMMING
P
ENTER MAIN GROUP # 3
M
PRINTING ,,,
P
M
MAIN GROUP
PROGRAMMING
P
ENTER MAIN GROUP # 0
M
Full Report Printing
1) At Main Group programming mode, print out full report.
S
S
S
*If you want to stop printing, press [FEED] key.
AM
CH
PE
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PRINTING ,,,
P
M
MAIN GROUP
PROGRAMMING
P
ENTER MAIN GROUP # 0
M
23
S
S
AM
CH
PE
AM
CH
PE
SM-300 Operation Manual (Advance)
3. Delete Main Group File
When the PLU FILE exists under the Main Group File, the Main Group Code data cannot be deleted. In
addition, the Main Group Code number 997, 998 and 999 cannot be deleted.
1) At Main Group Programming Mode, enter existing Main Group Number (Ex. 3) to be deleted.
KEY TO PRESS DISPLAY
¼O
»
MAIN GROUP
NET
PROGRAMMING
P
ENTER MAIN GROUP # 3
M
2) Enter deleting mode.
KEY TO PRESS DISPLAY
¼O
»
NET
DELETE?
P
PRESS: C(YES) / T(NO)
M
3) Delete Main Group Number 3.
*If you want to cancel the deletion, press [TARE] key to exit.
S
S
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
MAIN GROUP
NET
PROGRAMMING
P
ENTER MAIN GROUP # 0
M
S
AM
CH
PE
24
SM-300 Operation Manual (Advance)
PLU Item Selection
Unnecessary PLU parameters will be skipped automatically due to auto-skip function, it is possible to set
only necessary parameter for PLU File Programming. The following parameters are available for Plu File
Programming.
ParametersParametersParametersParameters
Label Format 1 Tare Special Message 2ND Price
Label format 2 Quantity Ingredient Percentage Tare
Barcode Selection Quantity Unit Place No. Traceability
Barcode Flag Data Discount Status Image Storage Temperature
Barcode Item Code Discount Date Bonus Pack. Indicator
Main Group Entry Discount Time ITF Selection Multi Barcode 1
Sell By Date Mark down Status Reference PLU No. Multi Barcode 2
Sell Time Discount Limit 1 Security PLU Total Multi Barcode 1
Used By Date Discount Limit 2 Coupled PLU Total Multi Barcode 2
Packed Date Special Message No. Discount day of the week Unit Price Selection
Packed Time Ingredient No. EAN 5 Digit ADD-ON Text
Cost Commodity Name TAX No.
1) At Programming Mode, select PLU Item Selection Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU ITEM SELECTION
P
ENTER: 0
M
S
2) Enter parameter selection mode.
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
LABEL FORMAT 1
P
USE X KEY -> DISABLE
M
25
S
AM
CH
PE
SM-300 Operation Manual (Advance)
3) Select parameter Example: Main Group Entry and ENABLE it.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
MAIN GROUP ENTRY
P
USE X KEY -> DISABLE
M
MAIN GROUP ENTRY
P
USE X KEY -> ENABLE
M
S
S
Note: Press [PRINT] key to next parameter or [-] key to previous parameter and select ENABLE or DISABLE for
parameters, which to be used or not in Plu Programming.
AM
CH
PE
AM
CH
PE
4) After finish setting, save it.
*If you want to exit without saving, press [CHANGE] key follow by [CLEAR] key.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU ITEM SELECTION
P
ENTER: 0
M
S
AM
CH
PE
26
SM-300 Operation Manual (Advance)
PLU Programming
The following items can be programmed in PLU PROGRAMMING mode. The format chosen for the
PLU will decide what items can be programmed in the PLU file. The items which print areas are not set
on the selected format will skip automatically or not printed on label. (If the item doesn't appear on the
PLU programming, check whether the parameter is set to ENABLE in PLU Item Selection
1. UNIT PRICE
21. SPECIAL MESSAGE BY PLU
.
2. LABEL FORMAT 1
3. LABEL FORMAT 2
4. COMMODITY NAME
5. ITF BARCODE DATA
6. BARCODE TYPE
7. FLAG CODE
8. ITEM CODE
9. EAN ADD-ON
10. MAIN GROUP NUMBER
11. SELL BY DATE / TIME
12. USED BY DATE
13. PACKED DATE / TIME
14. COST PRICE
15. PLU TARE
16. QUANTITY UNIT
27. REFERENCE PLU NUMBER
35. SERIAL NUMBER
22. INGREDIENT BY PLU
23. PLACE NUMBER
24. IMAGE NUMBER
25. COUPLED PLU NUMBER
26. TAX NUMBER BY PLU
28. SECURITY PLU
29. 2ND PRICE
32. STORAGE TEMPERATURE 1 & 2
34. UCC/EAN PREFIX
36. MULTI BARCODE 1
30. PERCENTAGE TARE
31. TRACEABILITY NUMBER
33. PACKAGING INDICATOR
17. QUANTITY
18. PLU DISCOUNT
19. SPECIAL MESSAGE NUMBER
20. INGREDIENT NUMBER
37. MULTI BARCODE 2
38. TOTAL MULTI BARCODE 1&2
39. TEXT NUMBER
40. BONUS POINT
27
SM-300 Operation Manual (Advance)
1. Program PLU File
PLU data is programmed by following procedure as below.
*If the selected 1st or 2nd label format does not have print area for the PLU items, the item will be skipped automatically
or not printed on label.
1) Enter Programming mode from Stand-by Status.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU PROGRAMMING
P
ENTER PLU # 0
M
S
2) Enter new PLU Number (Ex. 10) you want. *Maximum 6 digits of PLU Number can be entered.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU PROGRAMMING
P
ENTER PLU # 10
M
S
3) Enter PLU file programming mode.
[CLEAR] key
*To exit without saving data, press [CHANGE] key and follow by
KEY TO PRESS DISPLAY
¼O
»
NET
PLU #000010
P
U,PRC: 0,00 /KG
M
S
UNIT PRICE ENTRY
Unit Price per-kg (Weighing Item) is used to calculate the total price with the place weight and Unit Price
per-PCS (Non-Weighing Item) is used to calculate total price with Quantity. Maximum 6 digits can be
entering for Unit Price.
1) Enter Unit Price value (Ex. $ 1.23). For Non-weighing Item, press Preset key Number 7 ([P7]) or
Preset Key Number 8 ([P8]) to change /KG to /PCS.
KEY TO PRESS DISPLAY
*Unit Price per-100g can be set at the SPEC 600.
¼O
»
NET
PLU #000010
P
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
AM
CH
28
SM-300 Operation Manual (Advance)
M
PE
29
SM-300 Operation Manual (Advance)
UNIT PRICE OVERRIDE
Note: Used [MODE] key to toggle flags of UNIT PRICE OVERRIDE, NO PRICE CHANGE or
BLANK (PRICE CHANGE) in Individual PLU if Spec 178 & 244 set to YES. The following
messages will appear as below:
a) Unit Price Override per-PLU (SPEC 178 = YES), allow to change the Unit Price of the PLU
temporally by press the number keys at Registration Mode.
DISPLAY
¼O
»
NET
PLU #000010 UP OVERRID
P
U,PRC: 1,23 /KG
M
S
Image under plu price programming
b) No Price Change per-PLU (SPEC 244 = YES), not allow using Function keys to change the
Unit Price at Registration Mode (Ex. Constant Discount Function keys, Unit Price Override &
Unit Price Change function key).
AM
CH
PE
DISPLAY
¼O
»
NET
PLU #000010 NO PC CHG
P
U,PRC: 1,23 /KG
M
S
AM
CH
PE
Image under plu price programming
c) Price Change per-PLU (SPEC 244= YES), allow using Function keys to change the Unit
Price at Registration Mode. But not allow Direct Unit Price Override by press the number key.
DISPLAY
¼O
»
NET
PLU #000010
P
U,PRC: 1,23 /KG
M
Image under plu price programming
S
AM
CH
PE
2) Save the data and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU: 000010
P
LABEL FORMAT 1:DEF/T8
M
Label Format 1 Entry
S
AM
CH
PE
30
SM-300 Operation Manual (Advance)
Select an existing label format for 1
st
Label (Ex. T7) by pressing preset key [P7] or [P8]. Another way to
select the Label Format is by enter the label format number by numeric keys. (Please refer to Label
Format List).
*The default label format 1 can be set at the SPEC 24.
1) Select Label Format you want (Ex. T7).
KEY TO PRESS DISPLAY
or x 7 times
¼O
»
NET
PROGRAM PLU: 000010
P
LABEL FORMAT 1:T7 / 7
M
S
AM
CH
PE
2) Save and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU: 000010
P
LABEL FORMAT 2: NO USE
M
S
AM
CH
PE
Label Format 2 Entry
The default label format 2 can be set at Spec 217 and only exist Free Format (F1 ~ F99) can be enter for
nd
label format. *If not necessary to set Label Format 2, press [PRINT] key to next step.
the 2
1) Select Label Format you want (Ex. F1) by enters the Label Format Number and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
PROGRAM PLU: 000010
P
LABEL FORMAT 2: F1 / 1
M
»
PLU #000010 P:KEY
P
M3/26/01:
M
S
S
AM
CH
PE
AM
CH
PE
Commodity Name Entry
Maximum 4 lines can be programmed for Commodity Name and number of lines or maximum of
characters entry is depends on the Character Size entry or size of the print area. If selected label without
print area for Commodity Name, maximum 1 line of 46 characters can be enter for receipt printing
(Maximum 2 lines of 25 letters of Commodity Name can be printed on receipt paper).
1) Enter the Commodity Name (Ex. BEEF SIRLOIN) by Preset Key and go to next selection.
31
SM-300 Operation Manual (Advance)
KEY TO PRESS DISPLAY
¼O
• • • • • • •
»
NET
¼O
»
NET
PLU # 000010 P:KEY
P
W
M3/14/01:BEEF SIRLOIN
M
PLU # 000010 P:KEY
P
M3/26/02:
M
S
S
Note: Please refer to Preset Keys Function in Programming Mode and Table of Characters Code for Commodity
Name entries by using ASCII Code (A) or TERAOKA Code (T).
AM
CH
PE
AM
CH
PE
nd
2) Enter the commodity description data in the 2
row if necessary. If not, press [PRINT] key without data
and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
P
SELECT ITF(1:Y/0:N)? 0
M
S
AM
CH
PE
Select ITF Barcode Data
When ITF Barcode Data been select, the parameter of EAN 5 Digits Add-On will skipped and default
barcode data to ITF Barcode format can be set at SPEC 331.
1) Select “NO PRINT” ITF Barcode Format.
and follow by [PRINT] key.
*If you want to print ITF Barcode Data on label, press [1] key
KEY TO PRESS DISPLAY
¼O
»
NET
PLU # 000010 BAR CODE
P
32
S
AM
CH
SM-300 Operation Manual (Advance)
M
PE
33
SM-300 Operation Manual (Advance)
Barcode Type Entry
The default Item barcode type can be set at Spec 0 and print Right Side Data of the barcode type can be
set at Spec 1. The following selections are available:
0: QUANTITY
1: PRICE
(*Before Tax or After Tax can be set at Spec 2 and print PRICE After Tax on Item Label can be set
at Spec 659).
2: WEIGHT
3: USER PROGRAMMABLE
4: ORIGINAL PRICE
5: WEIGHT / QUANTITY
6: UNIT PRICE
7: UNIT PRICE AFTER DISCOUNT
1) Select the Barcode Data you want (Ex. F1F2 CCCCC 0 XXXX CD) and go to next parameter.
want barcode data by default, just press [PRINT] key to go to next step.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PLU # 000010 BAR CODE
P
F1F2 CCCCC 0 XXXX CD
M
PROGRAM PLU # 000010
P
FLAG CODE: DEFAULT >>
M
S
S
*If you
AM
CH
PE
AM
CH
PE
Note: Please refer to Barcode List to select the barcode type you want.
Barcode Flag Entry
The Default Flag Data can be set at SPEC 3 ~ 6 and the Flag data consists of one or two digits, which
depends on the selected Barcode type.
1) Enter Flag Code manually setting mode, then enter new Flag Code you want (Ex. 22) and go to next
parameter.
KEY TO PRESS DISPLAY
or
*If not necessary to change the Flag Code, just press [PRINT] key to go to next step.
¼O
»
NET
¼O
NET
PROGRAM PLU # 000010
P
ENTER FLAG CODE: 02
M
»
PROGRAM PLU # 000010
34
S
S
AM
CH
PE
AM
SM-300 Operation Manual (Advance)
P
ENTER ITEM CODE: 00000
M
CH
PE
35
SM-300 Operation Manual (Advance)
Item Code Entry
Maximum Digits of Item Code entry is depends on the Barcode type selected and if you want the Item
Code automatically same as the PLU Number, SPEC 191 must set to "YES" in advance.
1) Enter Item Code you want (Ex. 10161) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PROGRAM PLU # 000010
P
ENTER ITEM CODE: 10161
M
PROGRAM PLU # 000010
P
EAN ADD-ON(1:Y/0:N)? 0
M
S
S
EAN Add-On Barcode Data Entry
This parameter will skip if parameter of Select ITF Barcode Data set to PRINT.
1) Select “NO PRINT” for EAN ADD-ON Barcode data on label.
and follow by press [PRINT] key.
*To select “PRINT”, just press [1] key
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
P
MAIN GROUP CODE: 997
M
S
Main Group Code Entry
The PLU will be linked to the programmed Main Group Number. If the PLU in not linked to a Main
Group, then the PLU will be assigned to Main Group Number 997 by default. Main Group Code will
print on item label if selected label format with print area for Main Group Code.
1) Enter existing Main Group Number (Ex. 111) and next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PROGRAM PLU # 000010
P
MAIN GROUP CODE: 111
M
PROGRAM PLU # 000010
S
S
AM
CH
PE
AM
CH
PE
AM
36
SM-300 Operation Manual (Advance)
P
SELL BY DATE(1:Y/0:N)1
M
CH
PE
37
SM-300 Operation Manual (Advance)
Sell-by-Date & Sell Time Entry
Maximum value 999 can be enter for Sell-by-Date.
Note:
• The Sources of Sell-by-Date (FROM CURRENT DATE or FORM PACKED DATE) can be select at
SPEC 109.
•If Sell-by-Date enter more than 90days, print DAY of Sell-by-Date on item label can be select at SPEC
142.
• Program Sell by Date or Sell by Time for individual PLU can be select at SPEC 152 (Use [X]key to
toggle).
• Print ZERO or PLU Setting Sell-by-Date on label in MANUAL MODE can be select at SPEC 201.
• Print Format of Year on label can be select at SPEC 17 and print digits of Year on label can select at
SPEC 141.
• Print Format of Month on label can be select at SPEC 197.
• Print Format of Time on label can be select at SPEC 233.
• Print Date Title on label can be set at SPEC 167.
1) Select “PRINT” Sell-by Date on item label.
PRINT” Sell-by Date on item label.
*Press [0] key and follow by [PRINT] key to select “NO
KEY TO PRESS DISPLAY
¼O
»
NET
PLU #000010 SELL BY DT
P
FROM CURRENT DATE: 0
M
2) Enter days for Sell-by-Date (Ex. 3 days) and go to next parameter.
skip if selected format with out print area for Sell Time.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
PLU #000010 SELL BY DT
P
FROM CURRENT DATE: 3
M
»
PROGRAM PLU # 000010
P
SELL TIME(1:Y/0:N)? 1
M
3) Select “PRINT” Sell Time on Item Label.
PRINT” Sell Time on item label.
*Press [0] key and follow by [PRINT] key to select “NO
AM
S
CH
PE
*The parameter for SELL TIME will
AM
S
CH
PE
AM
S
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
38
S
AM
SM-300 Operation Manual (Advance)
P
(0:CLOCK /1:MANUAL) 0
M
CH
PE
39
SM-300 Operation Manual (Advance)
4) Select manually enter Sell Time.
*Press [0] key and follow by [PRINT] key to select “Current Time”.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU #000010 SELL TIME
P
ENTER 00:00
M
S
AM
CH
PE
5) Enter Sell Time you want (Ex. 1330 = 1:30PM) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PLU #000010 SELL IME
P
ENTER 13:30
M
PROGRAM PLU # 000010
P
USED BY DATE(1:Y/0:N)0
M
S
S
AM
CH
PE
AM
CH
PE
Used By Date Entry
Maximum 999 days can be entering and this parameter will skip if selected label format with out print area
for Used by Date.
1) Select “PRINT” Used-by Date on item label.
PRINT” Used-by Date on item label.
*Press [0] key and follow by [PRINT] key to select “NO
KEY TO PRESS DISPLAY
¼O
»
PROGRAM PLU # 000010
P
USED DATE: 0
M
NET
2) Enter days for Used-by-Date (Ex. 10 days from Current Date) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
PROGRAM PLU # 000010
P
USED DATE: 10
M
»
PROGRAM PLU # 000010
P
PACKED DATE(1:Y/0:N)?1
M
NET
¼O
NET
40
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
SM-300 Operation Manual (Advance)
Packed Date & Packed Time Entry
Maximum 999 days can be entering for Packed Date.
Note:
• Print PLU setting packed date on item label in Manual Mode can be select at SPEC 654.
• Not allow entering DAY of the Packed Date more than DAY of the Sell-by-Date, if SPEC 109 is set to
FROM CURRENT DATE.
1) Select “PRINT” Packed Date on item label.
PRINT” Packed Date on item label.
KEY TO PRESS DISPLAY
¼O
»
NET
P
M
2) Enter days for Packed-Date (Ex. 2 days) and go to next parameter.
will skip if selected format with out print area for Packed Time.
*Press [0] key and follow by [PRINT] key to select “NO
PROGRAM PLU # 000010
PACKED DATE: 0
*The parameter of PACKED TIME
S
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
PROGRAM PLU # 000010
P
PACKED TIME(1:Y/0:N)?1
M
NET
3) Select “PRINT” Packed Time on item label.
PRINT” Packed Time on item label.
*Press [0] key and follow by [PRINT] key to select “NO
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
P
(0:CLOCK /1:MANUAL) 0
M
4) Select manually enter Packed Time.
*Press [0] key and follow by [PRINT] key to select “Current Time”.
KEY TO PRESS DISPLAY
¼O
»
PLU000010 PACKED TIME
P
ENTER 00:00
M
NET
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
41
SM-300 Operation Manual (Advance)
5) Enter Packed Time you want (Ex. 700 =7:00AM) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
P
COST: 0,00
M
S
AM
CH
PE
Cost Price Entry
Cost Price is the buying price by store, so the Cost value must be equal or less than the Unit Price.
1) Enter Cost value (Ex. $0.73) and go to next parameter.
*Parameter of PLU Tare will appear.
KEY TO PRESS DISPLAY
¼O
»
PROGRAM PLU # 000010
P
COST: 0,73
M
»
PROGRAM PLU # 000010
P
SET TARE VALUE: 0,000
M
NET
¼O
NET
Note: For Non-Weight Item, the parameter of Quantity Unit Entry will appear.
S
S
AM
CH
PE
AM
CH
PE
DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
P
QUANTITY UNIT>> NO SYM
M
S
AM
CH
PE
PLU Tare Entry
This parameter appears for Weighing Item only (For Unit Price /kg or /100g) and for Non-Weighing
Item, this parameter will skip. To enable PLU Tare Entry, Spec 647: PLU TARE must set to ALLOW
and in PLU ITEM SELECTION, the parameter of the PLU TARE must set to ENABLE in advance.
*Please refer to PLU Item SelectionNote:
• Tare value will print on item label if the selected label format will print area for Tare value and SPEC 642
must set to ALLOW in advance.
• Maximum PLU Tare value is depends on SPEC 638 setting.
1) Enter Tare value (Ex. 10g) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
SELECT DISCOUNT TYPE
42
S
AM
SM-300 Operation Manual (Advance)
P
>> NO DISCOUNT
M
CH
PE
43
SM-300 Operation Manual (Advance)
Quantity Unit Entry
Quantity Unit Entry is for Non-Weighing Item (For Unit Price /PCS) to select type of the Quantity
Symbol and printed on receipt paper or Item Label at Pre-pack Mode. For Weighing Item, this parameter
will skip.
Note: Print PLU setting Quantity Unit on label in Manual Mode, SPEC 98 & 99 must set to ALLOW and SPEC
169 must set to YES in advance.
1) Select Unit Symbol you want (Ex. FOR) and
KEY TO PRESS DISPLAY
Note: Refer the following rotation to select the Quantity Symbol by press Preset key number 7 or Preset key
number 8.
go to next parameter.
¼O
»
NET
¼O
NET
PROGRAM PLU # 000010
P
QUANTITY UNIT>> FOR
M
»
PROGRAM PLU # 000010
P
QUANTITY: 0
M
S
S
AM
CH
PE
AM
CH
PE
Quantity Entry
Quantity Entry is for Non-weighing Item to set Quantity value for those items. Maximum 9999 can be
entering. For Weighing Item, this parameter will appear only when SPEC 166: AVERAGE PRICE & WEIGHT LABEL FUNCTION set to ENABLE.
1) Enter
Quantity value (Ex. 5) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
PROGRAM PLU # 000010
P
QUANTITY: 5
M
»
SELECT DISCOUNT TYPE
P
>> NO DISCOUNT
M
S
S
AM
CH
PE
AM
CH
PE
44
SM-300 Operation Manual (Advance)
Discount Type Entry
To enable PLU Discount, the Spec 100: Program PLU Discount must set to ALLOW and in PLU
ITEM SELECTION, all parameters of the Discount Status must set to ENABLE in advance.
*Please refer to PLU Item Selection
1) Select Discount type you want (Ex. Unit Price Discount).
KEY TO PRESS DISPLAY
¼O
»
SELECT DISCOUNT TYPE
P
>> U, PRICE DISCOUNT
M
NET
Note: Refer the following rotation to select the Discount Type by press Preset key number 7 or Preset key
number 8.
S
AM
CH
PE
2) Enter 1ST limit discount data.
*Refer to Table 1 at next page.
KEY TO PRESS DISPLAY
¼O
»
NET
U, PRICE DISCOUNT
P
1ST MIN (Kg): 0,000
M
st
3) Enter the 1
enter the Quantity value for the 1
limit of weight data (Ex. 500g) and go to next parameter. *For Non-Weighing item, please
st
MIN (PCS).
KEY TO PRESS DISPLAY
¼O
»
U, PRICE DISCOUNT
P
1ST MIN (Kg): 0,500
M
»
U, PRICE DISCOUNT
P
1ST DISCOUNT : 0,00
M
NET
¼O
NET
st
4) Enter the Discount Unit Price for the 1
limit (Ex. $1.10) and go to next parameter.
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
U, PRICE DISCOUNT
P
2ND MIN (Kg): 99,999
M
45
S
AM
CH
PE
SM-300 Operation Manual (Advance)
Table 1
Discount Type Formula Example
Free Item
To called up PLU with 0 Unit
Price and allow issuing a receipt or
label, SPEC 231 must set to
"ALLOW" in advance.
Unit Price Discount
To select Formula (1) or
Formula (2) can be decided by
SPEC 124 Setting.
Price = 0 Total Price = 0
(1) Unit Price = Original Unit
Price - Unit Price discount
amount.
(2) Unit Price = Unit Price
discount amount.
Unit Price % Discount
Unit Price = Original Unit
Price x (100% - % Discount)
Total Price DiscountTotal Price = Original Price -
Price Discount Amount
Original Unit Price = $ 10.00
Unit Price discount amount = $2.00
(1) Unit Price = $10.00 - $2.00 =
$8.00
(2) Unit Price = $2.00
Original Unit Price = $ 10.00
% Discount = 20%
Unit Price = $10.00 x (100% - 20%)
= $8.00
Original Total Price = $10.00
Price Discount Amount = $2.00
Total Price = $10.00 - $2.00 = $8.00
Total Price % Discount Total Price = Original Total
Price x (100% - % Discount)
Original Total Price = $10.00
% Discount = 20%
Total Price = $10.00 x (100% - 20%)
= $8.00
Fixed Price Discount Total Price = Fixed Price
Amount
Original Total Price = $10.00
Fixed Price Amount = $8.00
Total Price = $8.00
5) Enter the 2nd limit of weight data (Ex. 1kg) and go to next parameter.
enters the Quantity value for the 2
[PRINT] key to go to next step.
nd
MIN (PCS). If not necessary to enter 2nd limit of discount, just press
KEY TO PRESS DISPLAY
¼O
»
U, PRICE DISCOUNT
P
2ND DISCOUNT: 1,10
M
NET
*For Non-Weighing item, please
AM
S
CH
PE
46
SM-300 Operation Manual (Advance)
47
SM-300 Operation Manual (Advance)
6) Enter the Discount Unit Price for the 2nd limit (Ex. $1.00) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
MARKDOWN TYPE (0-3): 0
P
NO MARKDOWN
M
S
7) Select the Markdown type (Ex. Price & Unit Price Markdown) by press the Numeric and go to next
parameter.
Price will be crossed with 2lines.
*If markdown is selected, the original price & discount price will print on item label and the Original
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
MARKDOWN TYPE (0-3): 3
P
P, & U, P, MARKDOWN
M
»
U, PRICE DISCOUNT
P
START DATE 00-00-00
M
S
S
MARKDOWN TYPE
[0]- NO Markdown. [1]- Unit Price Markdown. [2]- Price Markdown.
AM
CH
PE
AM
CH
PE
AM
CH
PE
[3]- Price & Unit Price Markdown.
Discount Schedule Setting
Discount schedule setting is available by setting the following items in PLU Discount Mode.
st
(1) 1
TRAGET WEIGHT / QUANTITY (First limit)
(2) DISCOUNT PRICE for first limit.
nd
(3) 2
TRAGET WEIGHT / QUANTITY (Second limit)
(4) DISCOUNT PRICE for second limit.
(5) START DATE / TIME of the set discount price.
(6) END DATE / TIME of the set discount price.
(7) DISCOUNT DAY OF THE WEEK to select discount price for the day of the week.
With the discount schedule, the flexible discount price setting can be programmed and the sales loss by
forgetting returning the discount price to the original price can be avoided.
48
SM-300 Operation Manual (Advance)
1) Enter start date (Ex. 020504 = 2 May 2004) and go to next parameter.
*Date format is depending on Spec
17 setting.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
U, PRICE DISCOUNT
P
START DATE: 02-05-04
M
U, PRICE DISCOUNT
P
START TIME: 00:00
M
S
S
Note: If not necessary to program Discount Schedule, just press [PRINT] key to next parameter you want.
2) Enter start time (Ex 1100 =11:00AM) and go to next parameter.
176 setting.
*Discount Time type is depend on Spec
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
U, PRICE DISCOUNT
P
START TIME: 11:00
M
U, PRICE DISCOUNT
P
END DATE: 00-00-00
M
S
S
3) Enter the End Date (Ex. 090205 = 9 May 2004) and go to next selection.
AM
CH
PE
AM
CH
PE
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
U, PRICE DISCOUNT
P
END DATE: 09-05-04
M
»
U, PRICE DISCOUNT
P
END TIME: 00:00
M
NET
¼O
NET
4) Enter End Time (Ex. 1400 = 2:00PM) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
DISC ON: S M T W T F S
P
ENTER: 0 0 0 0 0 0 0
M
NET
49
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
SM-300 Operation Manual (Advance)
5) Select Discount Day of the week (Ex NO DISCOUNT on FRIDAY) and go to next parameter.
*0-
Discount or 1- No Discount.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
DISC ON: S M T W T F S
P
ENTER: 0 0 0 0 0 1 0
M
PROGRAM PLU # 000010
P
ENTER SP, MSG# 0
M
S
S
AM
CH
PE
AM
CH
PE
Special Message Number Entry
Special message number can be selected from master special message data programmed in advance.
Special message number only can be entered when free format (F1~F99) with special message print area is
selected for the PLU. This parameter will skip if selected label format with out print area for Special
Message.
1) Enter existing Special Message Number (Ex. 12) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PROGRAM PLU # 000010
P
ENTER SP, MSG# 12
M
PROGRAM PLU # 000010
P
ENTER INGREDIENT# 0
M
S
S
Ingredient Number Entry
Ingredient Number can be selected from master Ingredients data programmed in advance. Ingredient
Number only can be entered when free format (F1~F99) with ingredient print area is selected for the
PLU. This parameter will skip if selected label format with out print area for Ingredient.
1) Enter existing Ingredient Number (Ex. 41) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
PROGRAM PLU # 000010
P
ENTER INGREDIENT# 41
M
PLU000010SP MSG/P:KEY
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
50
NET
P
S1/26/01:
M
SM-300 Operation Manual (Advance)
AM
S
CH
PE
51
SM-300 Operation Manual (Advance)
Programming of Individual Special Message
Special message by PLU is the special message data programmed in a PLU, and only applied for the PLU.
Maximum 30 lines can be programmed for Special message and number of lines or maximum of
characters entry is depends on the Character Size entry or size of the print area. This parameter will skip if
selected label format with out print area for Special Message.
Note: If you want print Individual Special message on item label for the PLU, the parameter of Special Message
Number Entry must set to “0”.
1) If necessary to print Individual Special Message, enter the Individual Special Message Data (Ex.
TODAY SPECIAL) as the same procedure as Commodity Name entry. If not, just press [PRINT] key
to go to next parameter.
KEY TO PRESS DISPLAY
• • • • • • • • •
¼O
»
NET
¼O
»
NET
PLU000010SP MSG/P:KEY
P
W
S1/13/01:ODAY SPECIAL
M
PLU000010SP MSG/P:KEY
P
W
S1/26/02:
M
S
S
AM
CH
PE
AM
CH
PE
2) Enter Special Message Data in the 2
nd
row if necessary. If not, press [PRINT] key go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU000010 INGR P:KEY
P
S1/24/01:
M
S
AM
CH
PE
Programming of Individual Ingredient
Individual Ingredient is the ingredient data programmed in a PLU, and only applied for the PLU.
Maximum 99 lines can be programmed for Ingredient data and number of lines or maximum of characters
entry is depends on the Character Size entry or size of the print area. This parameter will skip if selected
label format with out print area for Ingredient data.
Note: If you want print Individual Ingredient data on item label for the PLU, the parameter of Ingredient Number
Entry must set to “0”.
1) If necessary to print Individual Ingredient, enter the Individual Ingredient Data (Ex. SUGAR) as the
same procedure as Commodity Name entry.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU000010 INGR P:KEY
52
S
AM
P
W
S1/19/01:SUGAR
M
SM-300 Operation Manual (Advance)
CH
PE
53
SM-300 Operation Manual (Advance)
2) Go to next selection.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU000010 INGR P:KEY
P
W
S1/24/02:
M
S
AM
CH
PE
nd
3) Enter Ingredient Data in the 2
row if necessary. If not, press [PRINT] key go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
P
ENTER PLACE# 0
M
S
AM
CH
PE
Place Number Entry
Place Number can be select from Master Place data programmed in advance. If the selected label format
without print area for Place data, the place data will print on 1
print area.
1) Enter existing Place number (Ex. 10) and go to next parameter.
st
line of the free room of Commodity name
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
P
ENTER IMAGE 1 # 0
M
S
AM
CH
PE
Image Number Entry
Image can be printed on a Free Format with the image print area. Maximum 10 images (Image # 1 to 10)
can be printed on one label. To select the favorite image for the PLU, the images must be downloaded in
the machine in advance. The Image 1 to 10 will skip if selected label format without print area for its.
Note: Image copy from Free Format can be set at SPEC 156.
1) Enter existing Image Number for Image 1 (Ex. 10) and then go to next parameter.
number 7 or Preset key number 8 to search the existing Images number.
KEY TO PRESS DISPLAY
¼O
»
COUPLED PLU# 0
P
M
NET
*Press Preset key
S
AM
CH
PE
54
SM-300 Operation Manual (Advance)
55
SM-300 Operation Manual (Advance)
Coupled PLU Number Entry
Coupled PLU Number is used for Accumulate only and for Non-weighing Item, press [X] key to select
"AUTO COPY QTY" (The message will show on bottom row of the display).
1) Enter Coupled PLU No. (Ex. PLU No. 1) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
P
ENTER TAX# 0
M
S
AM
CH
PE
Individual Tax Number Entry
TAX Number can be select from Master TAX data programmed in advance. If the PLU Tax number
have be enter, the Tax Rate for the PLU will follow the Tax Number setting, not follow Tax Number
linked to the Main Group Number.
1) Enter existing Tax Number (Ex. 2) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000010
P
REFERENCE PLU# 0
M
S
Reference PLU Number
This parameter is for call up referred plu for printing. In Registration Mode call up a plu, then press
Reference PLU function key, it display the referred plu for.
To enable this parameter set SPEC 204 to ENABLE.
1) Enter Reference PLU Number (Ex. 2) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
PROGRAM PLU # 000010
P
REFERENCE PLU# 2
M
»
PROGRAM PLU # 000010
P
SECURITY PLU(1:Y/0:N)0
M
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
56
SM-300 Operation Manual (Advance)
Security PLU Entry
This parameter is for Enable or Disable PLU Security. Security PLU must set to ENABLE in advance.
*Please refer to PLU Item Selection
1) Select “Yes” for PLU Security enter 1,
*if no need security set to NO, enter 2
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
PROGRAM PLU # 000010
P
SECURITY PLU(1:Y/0:N)1
M
»
PROGRAM PLU # 000010
P
2ND PRICE 0,00
M
S
S
AM
CH
PE
AM
CH
PE
2ND Price Entry
2ND PRICE can be programmed as like “UNIT PRICE” but only can be used when [1/2] function
key is pressed at Registration mode. When [1/2] function key is pressed after call up the PLU (*Please
refer to [1/2] Function key), the quantity will become the half of the original quantity.
To enable this parameter set SPEC 237 to ALLOW.
1) Enter 2
nd
Price value (Ex. 0.55) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PROGRAM PLU # 000010
P
2ND PRICE 0,55
M
PROGRAM PLU # 000010
P
PERCENTAGE TARE 0.00
M
S
S
AM
CH
PE
AM
CH
PE
Percentage Tare Entry
This parameter appears for Weighing Item only (For Unit Price /kg or /100g) and for Non-Weighing
Item, this parameter will skip. Percentage tare function work, when weight loaded on platter. To enable
Percentage Tare Entry, Spec 687: PROPORTIONAL TARE must set to ALLOW and in PLU ITEM
57
SM-300 Operation Manual (Advance)
SELECTION, the parameter of the PERCENTAGE TARE must set to ENABLE in advance.
refer to PLU Item Selection
*Please
Note:
• Percentage Tare value will print on item label if the selected label format will print area for Proportional
Tare value and SPEC 642 must set to ALLOW in advance.
• Maximum PLU Tare value is depends on SPEC 638 setting.
1) Enter Percentage Tare value (Ex. 30%) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PROGRAM PLU # 000010
P
PERCENTAGE TARE 30.00
M
PLU000010 TRACEABILITY
P
(YES - 1 / NO - 0): 0
M
S
S
AM
CH
PE
AM
CH
PE
Traceability Setting
The Traceability Setting is to select print Traceability Information of Beef item on Label or Receipt
printing. To enable this parameter, SPEC 258: BEEF LABELLING must set to YES in advance. The
Traceability Information will not printed on label, if selected label format with print area for Traceability
items.
1) Select “PRINT” Traceability Information.
*For Non-Beef Item, please set to NO.
KEY TO PRESS DISPLAY
2) Enter existing Traceability Number (Ex. 24) and then go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
¼O
»
PROGRAM PLU # 000010
P
TRACEABILITY # 0
M
PROGRAM PLU # 000010
P
TRACEABILITY # 24
M
PROGRAM PLU # 000010
58
S
S
AM
CH
PE
AM
CH
PE
SM-300 Operation Manual (Advance)
NET
P
TEMPERATURE 1ST: NON
M
S
AM
CH
PE
STORAGE TEMPERATURE 1ST & 2nd LIMIT
The Storage Temperature will not printed on label if selected label format without print area for Storage
Temperature.
1) Enter Temperature for 1
KEY TO PRESS DISPLAY
2) Enter Temperature for 2
press [PRINT] key go to next parameter.
st
limit (Ex. – 10 ºC) and go to next parameter.
¼O
»
NET
¼O
NET
¼O
NET
nd
limit (Ex. 10 ºC) and go to next parameter. *If not necessary to set 2
PROGRAM PLU # 000010
P
TEMPERATURE 1ST: 10
M
»
PROGRAM PLU # 000010
P
TEMPERATURE 1ST: - 10
M
»
PROGRAM PLU # 000010
P
TEMPERATURE 2ND: NON
M
S
S
S
nd
limit, just
AM
CH
PE
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
PLU #000010 PACK, INDI
P
PACKAGING INDICATOR: 0
M
S
Serial Shipping Container Code
Serial Shipping Container Code consists of Packaging, UCC/EAN, and Serial Number. Used for
UCC/EAN 128 Barcode Printing
The General Code Structure ex. P MMMMMMM SSSSSSSSS C 1 <- - - 7 - - - > <- - 9 - - > 1
P = Packaging Indicator S..S = Serial number
M..M = UCC/EAN Prefix/Company Number C = Data Check Digit
59
AM
CH
PE
SM-300 Operation Manual (Advance)
Packaging Indicator
To enable programming for Packaging Indicator, Multi Barcode print area muse be set in advance. 0 to 9
can be entering for Packaging Indicator.
1) Enter Packaging Indicator value you want (Ex. 5) and go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
PLU #000010 PACK, INDI
P
PACKAGING INDICATOR: 5
M
»
PLU #000010 UCC/EAN PR
P
UCC/EAN PREFIX: 0
M
S
S
AM
CH
PE
AM
CH
PE
UCC/EAN PREFIX
To enable programming for UCC/EAN Prefix, Multi Barcode print area muse be set in advance in Free
Format Programming.
1) Enter UCC/EAN value you want (Ex. 125) and then go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
PLU #000010 UCC/EAN PR
P
UCC/EAN PREFIX: 125
M
»
PLU #000010 SERIAL NO
P
SERIAL NO : 0
M
NET
¼O
NET
Serial Number Entry
To enable programming for Serial Number, Multi Barcode print area muse be set in advance.
1) Enter Serial Number that you want (Ex. BC12033) and then go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU #000010 SERIAL NO
P
SERIAL NO : BC12033
M
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
60
SM-300 Operation Manual (Advance)
¼O
»
NET
M1BAR EAN128A/ A:
P
W
CHAR 1:
M
S
AM
CH
PE
Multi Barcode 1 Entry
There has 3 type of Barcode EAN 128A, EAN 128B and EAN128C can be select in Multi Barcode
programming mode. Maximum 16 alphanumeric (ASCII Code only) can be entered for barcode type for
EAN 128A and EAN 128B.
Note: Press Preset Key [X] to select the Barcode Type (EAN 128A t EAN 128B t EAN 128C t EAN 128A).
1) Enter Barcode data by using PRESER KEY (Ex. ABCDEF1234567890) as same as Department Name
entry and next parameter.
KEY TO PRESS DISPLAY
¼O
• • • • • • • • • • • • •
»
NET
¼O
»
NET
M1BAR EAN128A/ P:KEY
P
CHAR17:CDEF1234567890
M
M2BAR EAN128A/ A:
P
W
CHAR 1:
M
S
S
Note: Program EAN 128A & 128B is same procedure. For EAN 128C, please refer to Multi Barcode 2 Entry.
Multi Barcode 2 Entry
1) Select EAN 128C for Multi Barcode 2 and then select F CD.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
M2BAR F CD EAN128C
P
W
M
P
M
W
M2BAR F CD EAN128C
W
F CD
W
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
AM
CH
PE
61
SM-300 Operation Manual (Advance)
2) Select the Barcode type you want (Ex. 01 and 13).
KEY TO PRESS DISPLAY
¼O
»
M2BAR F(01) AN128C
P
W
F (01)CD
M
W
»
M2BAR F(03) EAN128C
P
W
F (01)(03)CD
M
W
NET
¼O
NET
3) Go to next selection.
KEY TO PRESS DISPLAY
¼O
»
NET
Note: Refer the following rotation to select the Barcode Type by press Preset key [X].
M1TTL EAN128A/ A:
P
W
CHAR 1:
M
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
F CD t 01 t 13 t 15 t 17 t 30 t 31XX t 32XX t 10 t 251 t 422 t 423 t 424 t 425 t
426 t 7030 t 7031 t F CD
Total Multi Barcode 1 & 2 Entry
Procedure to program Total Multi Barcode 1 and Total Multi Barcode 2 is same as Multi Barcode 1 & 2
Entry.
1) Program A123456 for Total Multi Barcode 1 (EAN 128A) and F (15) XXXXXX (17) XXXXXXCD
for Total Multi Barcode 2 (EAN128C).
KEY TO PRESS DISPLAY
• • • • •
¼O
»
NET
¼O
»
NET
¼O
»
NET
¼O
»
NET
M1TTL EAN128A/ P:KEY
P
W
CHAR 8:A123456
M
M2TTL F CD EAN128C
P
W
M
W
M2TTL F(15) EAN128C
P
W
F (15)CD
M
W
M2TTL F(17) EAN128C
P
W
S
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
AM
CH
62
SM-300 Operation Manual (Advance)
M
W
¼O
»
NET
PLU #000010
P
ENTER TEXT 1 # DEFAUL
M
S
PE
AM
CH
PE
Text Number Entry
Text is used for printing the fixed data on label such as ‘Unit Price’, ‘Packed Date’. To enable this parameter
(PLU Text), SPEC 320: PLU LINK TO TEXT FIELD must set to ENABLE in advance. To print
programmed text, the selected label format must with print area for Text and Text must set to ENABLE
in advance in
PLU Item Selection. To Program Text, check Text File Programming
1) Enter existing Text Number (Ex. 5) and then go to next parameter.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
PLU #000010
P
ENTER TEXT 1 # 5
M
»
PROGRAM PLU # 000010
P
BONUS POINT: 0
M
S
S
AM
CH
PE
AM
CH
PE
Bonus Point Entry
Bonus point given per item (weight item per/kg and non-wt per pcs) and it is printed on label
1) Enter Bonus Point value (Ex. 15)
KEY TO PRESS DISPLAY
¼O
»
PROGRAM PLU # 000010
P
BONUS POINT: 15
M
NET
2) Save the data and the display will back to PLU Programming Mode.
data, press [CHANGE] key follow by [CLEAR] key.
S
*If you want to exit without saving
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
PLU PROGRAMMING
P
ENTER PLU # 0
M
63
S
AM
CH
PE
SM-300 Operation Manual (Advance)
64
SM-300 Operation Manual (Advance)
2. PLU [COPY] Function
The programmed PLU data can be easily copied into a new PLU. The function is very useful to save time or
avoid mistake for the similar PLU data programming, especially in case of long description of Ingredients.
1) At PLU Programming Mode, enter new PLU Number (Ex. 100) programming mode.
KEY TO PRESS DISPLAY
¼O
»
PLU #000100
P
U,PRC: 0,00 /KG
M
NET
2) Enter PLU Copy Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
PROGRAM PLU # 000100
P
COPY FROM PLU # 0
M
3) Enter the existing PLU number of copy source (Ex. 10).
File.
*Modify the PLU Data as same as Program PLU
S
S
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
PLU #000010
P
U,PRC: 1,23 /KG
M
NET
4) After complete modify the PLU data, save it.
KEY TO PRESS DISPLAY
¼O
»
NET
PLU PROGRAMMING
P
ENTER PLU # 0
M
S
S
AM
CH
PE
AM
CH
PE
65
SM-300 Operation Manual (Advance)
3. Print PLU File
The following operation is used for checking PLU Data Programmed. The report is printed on receipt
paper or label and there are two different print types, Single Report or PLU TEST PRINTING
RANGE.
Note: Print out PLU data as item label when scale set to LABEL MODE and print PLU items list when scale set to
RECEIPT MODE.
Single Report Printing
1) At PLU Programming Mode, enter PLU Number (Ex. 10) for Single report printing.
KEY TO PRESS DISPLAY
¼O
NET
2) Print out Report for PLU Number 10.
»
PLU PROGRAMMING
P
ENTER PLU # 10
M
*If you want to stop printing, press [FEED] key.
S
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
PRINTING,,,
P
M
»
PLU PROGRAMMING
P
ENTER PLU # 0
M
*The message of “PRINTING . . .”
not appear when scale set to Label
Mode.
NET
¼O
NET
S
S
AM
CH
PE
AM
CH
PE
66
SM-300 Operation Manual (Advance)
PLU Test Printing Range
1) Enter PLU TEST PRINT mode.
KEY TO PRESS DISPLAY
¼O
»
NET
2) Enter Lower Range (Ex. 10) and go to next selection.
KEY TO PRESS DISPLAY
¼O
NET
3) Enter Upper Range (Ex. 100).
*If you want to cancel printing, press [CHANGE] key follow by [CLEAR] key.
PLU TEST PRINT
P
LOWER RANGE: 0
M
»
PLU TEST PRINT
P
UPPER RANGE: 999999
M
S
S
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
PLU TEST PRINT
P
UPPER RANGE: 100
M
NET
4) Print out Report.
between PLU No. 10 ~ 100 will print out).
*If you want to stop printing, press [FEED] key.(Note: Only existing PLU Number in
KEY TO PRESS DISPLAY
¼O
»
PRINTING,,,
P
M
»
PLU PROGRAMMING
P
ENTER PLU # 0
M
*The message of “PRINTING . . .”
not appear when scale set to Label
Mode.
NET
¼O
NET
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
67
SM-300 Operation Manual (Advance)
4. Delete PLU File
1) At PLU Programming Mode, enter PLU Number (Ex. 100) to be deleted.
KEY TO PRESS DISPLAY
¼O
»
NET
2) Enter deleting mode.
KEY TO PRESS DISPLAY
¼O
NET
3) Delete PLU Number 100.
*If you want to cancel the deletion, press [TARE] key to exit.
PLU PROGRAMMING
P
ENTER PLU # 100
M
»
DELETE?
P
PRESS: C(YES) / T(NO)
M
S
S
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
PLU PROGRAMMING
P
ENTER PLU # 0
M
S
AM
CH
PE
68
Label Format List
The table shown below is Standard Label Format List.
1st Label Format
Number
0 Not Available DEFAULT
1 Not Available T1 60 X 28
2 Not Available T2 60 X 31
3 Not Available T3 60 X 34
4 Not Available T4 60 X 40
5 Not Available T5 60 X 43
6 Not Available T6 60 X 46
7 Not Available T7 60 X 49
8 Not Available T8 60 X 55
2nd Label Format
Number
SM-300 Operation Manual (Advance)
For STD Countries Label Size (mm)
Label size set in
specification setting
9 Not Available T9 60 X 37
10 Not Available T10 60 X 40
11 Not Available T11 60 X 43
12 Not Available T12 60 X 49
13 Not Available S 40 X 28
14 Not Available A 40 X 46
15 Not Available B 40 X 46
16 Not Available C 40 X 62.5
17 1 F1 -
18 2 F2 -
19 3 F3 -
20 4 F4 -
21 5 F5 -
22 6 F6 -
23 7 F7 -
24 8 F8 -
25~115 9~99 F9~F99 -
Note: F1 to F99 --- available only when free format is programmed.
69
SM-300 Operation Manual (Advance)
Barcode List
1. EAN Barcode Format
NO. Bar Code Type NO.Bar Code Type
0 F1F2 CCCCC XCD XXXX CD 17 F1F2 CC XXXXXXXX CD
1 F2 CCCCCC XCD XXXX CD 18 CCC WWWW PPPPP CD
2 F1F2 CCCCC 0 XXXX CD 19 NON BARCODE
3 F1F2 CCCCCC XXXX CD 20 F1F2 CCCCC PCD XXXX CD
4 F1F2 CCCCC XXXXX CD 21 F1F2 RRRRR XXXXX CD
5 F2 CCCCCC XXXXX CD 22 F2 CCCCC XXXXXX CD
6 F2 CCCCC XXXXXX CD 23 FFF CCCC PPPPP CD
7 F1F2 CCCCCCCCCC CD 24 F1F2 CCCCC WWWWW CD
8 F1F2 CCCC XXXXXX CD 25 F2 CCCCC WWWWW 0 CD
9 F1F2 CCCCC CD 26 F1F2 CCCCCC WWWWW CD
10 F2 CC XXXX CD 27 NO BARCODE
11 NON BARCODE 28 F1F2 CCC XXXXXXX CD
12 F1X2 CCCCC XCD XXXX CD 29 F2 CCCCCCC WWWW CD
13 F1X2 CCCCCC XXXX CD 30 F1F2 CC NNN PPPPP CD
14 F1F2 CCCC XCD XXXXX CD 31 F1F2 C NNNN PPPPP CD
15 F2 CCCCC XCD XXXXX CD
16 F1F2 CCC XXXXXXX CD
F: Flag data
C: Item Code No.
X: Price or Quantity or Weight or Not Used (selected in USER SET UP)
W: Weight
P: Price
N: Receipt or Label serial number
CD: Check digit
Note: For Barcode type of 30 & 31, C = Fixed number by Spec 9 setting.
70
SM-300 Operation Manual (Advance)
2. ITF Barcode Format
NO. Bar Code Type NO. Bar Code Type
0 FF CCCCC XXXX WWWW CD 17
0FF CC XXXXXXXX WWWWWWWW
CD
1 F CCCCCC XXXX WWWW CD 18 0CCC WWWW PPPPP CD
2 0FF CCCCC 0 XXXX WWWW CD 19 CCCCCCC XXXXXXX
3 0FF CCCCCC XXXX WWWW CD 20 FF CCCCC XXX WWWW CD
4 FF CCCCC XXXXX WWWWW CD 21 FF RRRRR XXXXX WWWWW CD
5 F CCCCCC XXXXX WWWWW CD 22 F CCCCC XXXXXX WWWWW CD
6 0F CCCCC XXXXXX WWWWWW CD 23 FFF CCCC PPPPP WWWWW CD
7 0FF CCCCCCCCCC CD 24 FF CCCCC WWWWW PPPPP CD
8 0FF CCCC XXXXXX WWWWWW CD 25 F CCCCC WWWWW PPPPPP CD
9 FF CCCCC CD 26 FF CCCCCC WWWWW XXXXX CD
10 F CC XXXX WWWW CD 27 CCCCCCC XXXXXXX WWWWWW
11 NON BARCODE 28 FF CCC XXXXXXX WWWWW CD
12 FX CCCCC XXXX WWWW CD 29 F CCCCCCC WWWW PPPPP CD
13 0FX CCCCCC XXXX WWWW CD 30 NON ITF BARCODE
14 0FF CCCC XXXXX WWWWW CD 31 NON ITF BARCODE
15 0F CCCCC XXXXX WWWWW CD
16 FF CCC XXXXXXX WWWWWWW CD
W's - will be Weight for Weight Item, or Quantity for Non-Weight Item.
X's - can be Quantity, Price, Weight or user programmable depending on SPEC 01 setting at ITEM
BARCODE SPECS of USER SETUP.
If Spec 01 set to User Programmable, the last byte of EAN Data (7
X's definitions as follow:
LAST BYTE OF EAN DATA X's
?0(HEX) PRICE
?1(HEX) WEIGHT
?2(HEX) QUANTITY
?3(HEX) ORIGINAL PRICE
th
byte) determines
71
SM-300 Operation Manual (Advance)
Memory Status
The following operation is used for checking the number of existing PLU and remaining programmable
PLU.
1) At Programming Mode, select Memory Status Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
58 PLU PROGRAMMED
P
CAN ADD 4751 MORE
M
PLU
S
AM
CH
PE
72
SM-300 Operation Manual (Advance)
PLU Call Range Programming
The following operation is used to control a range of plu during plu call up in registration mode.
Example: Range of Plu 1 ~ 200 and save it
1) At Programming Mode, select PLU Call Range Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
¼O
NET
¼O
NET
2) At Registration Mode, call up PLU above range Ex. PLU 255.
message and if within range it show the plu.
PLU CALL LOWER RANGE
P
(0 – 999996): 0
M
»
PLU CALL LOWER RANGE
P
(0 – 999996): 1
M
»
PLU CALL UPPER RANGE
P
(0 – 999996): 200
M
»
PLU CALL LOWER RANGE
P
(0 – 999996): 1
M
* Calling plu above range will display error
S
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
W
»
0.000 0.000.00
P
0.000
M
W
W
»
PLU NOT IN RANGE
P
M
W
NET
¼O
NET
73
R
R
AM
CH
PE
AM
CH
PE
SM-300 Operation Manual (Advance)
Secure Price Threshold
1) At Programming Mode, select Secure Price Threshold Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
2) Select Unit Price ex: 2 and enter security price = 3.00
KEY TO PRESS DISPLAY
¼O
NET
¼O
NET
3) Save data and back to Secure Price Threshold Mode.
SECURE PRICE THRESHOLD
P
(NO:0 /TP:1 /UP:2) 0
M
»
SECURE PRICE THRESHOLD
P
(NO:0 /TP:1 /UP:2) 2
M
»
P
ENTER: 3.00
M
SECURITY PRICE
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
SECURE PRICE THRESHOLD
P
(NO:0 /TP:1 /UP:2) 0
M
S
AM
CH
PE
74
SM-300 Operation Manual (Advance)
Key Assignment
The preset keys assignment can speed up operation in REGISTRATION MODE. PLU Number, Clerk key,
Function keys and Preset Tare can be assigned on preset key.
1. PLU Assignment
Assign PLU Number to Preset Key
PLU Number can be assigned to a preset key to call up PLU data by pressing the assigned preset key on
Registration Mode.
For example:
1) At PLU Programming Mode, select PLU # Assignment Mode.
KEY TO PRESS DISPLAY
2) Enter PLU Number 10 by numeric key.
Assign PLU Number 10 to Preset Key Number 1.
¼O
»
NET
ASSIGN PLU # 0
P
TO DESTINED PRESET KEY
M
S
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
ASSIGN PLU # 10
P
TO DESTINED PRESET KEY
M
S
3) Press the Preset Key Number 1.
KEY TO PRESS DISPLAY
¼O
»
NET
ASSIGN PLU # 0
P
TO DESTINED PRESET KEY
M
Note: If assigning PLU Number 50 to the Preset key No. 1 has been already programmed, the PLU No. 50 will
replace the old data of Preset Key No. 1, but PLU Number cannot replace the preset key are already assign
for Function Key, Clerk Key or Preset Tare.
S
AM
CH
PE
AM
CH
PE
75
SM-300 Operation Manual (Advance)
Print Preset Key Assignment
The following operation is used for checking Preset Key Assignment. The report is printed on receipt
paper and there are two different print types, FULL Report & SINGLE Report. The Full report
includes all the programmed data and the Single report only includes one data.
Single Report Printing
1) At PLU # Assignment Mode, enter the Preset Key Number (Ex. 1) and then print out report.
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
¼O
NET
ASSIGN PLU # 1
P
TO DESTINED PRESET KEY
M
»
PRINTING,,,
P
M
»
PLU PROGRAMMING
P
ENTER PLU # 0
M
Full Report Printing
1) At PLU # Assignment Mode, print out report for all Preset key.
[FEED] key.
*If you want to stop printing, press
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
PRINTING,,,
P
M
»
PLU PROGRAMMING
P
ENTER PLU # 0
M
76
S
S
AM
CH
PE
AM
CH
PE
SM-300 Operation Manual (Advance)
Delete Preset Key Assignment
This operation is to delete the Preset Key assignment by entering the Number of the Preset Key at PLU
Number Assignment Mode.
1) At PLU # Assignment Mode, enter the Preset Key Number (Ex. 1) to be deleted.
KEY TO PRESS DISPLAY
¼O
»
NET
ASSIGN PLU # 1
P
TO DESTINED PRESET KEY
M
2) Enter deleting mode.
KEY TO PRESS DISPLAY
¼O
»
NET
DELETE?
P
PRESS: C(YES) / T(NO)
M
3) Delete Preset Key number 1 assignment.
*If you want to cancel the deletion, press [TARE] key to exit.
S
S
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
ASSIGN PLU # 0
P
TO DESTINED PRESET KEY
M
S
AM
CH
PE
77
SM-300 Operation Manual (Advance)
2. Clerk Key Assignment
Clerk key is used to accumulate the sales data of the operator that has been assigned for the clerk key.
There are 5 default Clerk Keys (C9995:[+A]), (C9996:[+B]), (C9997:[+C]), (C9998:[+D]), ([C9999]:
[PRINT] key) available. If you want to use other Clerk key, you need to assign the Clerk keys programmed
in advance on preset keys.
For example:
1) At PLU # Assignment Mode, enter the Assign Clerk Mode.
KEY TO PRESS DISPLAY
2) Enter Clerk Number 10 by numeric key and assign to Preset Key you want (Ex. [P32]).
Assign Clerk Number 10 to Preset Key Number 32.
¼O
»
NET
ASSIGN CLERK # 0
P
TO DESTINED PRESET KEY
M
S
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
ASSIGN CLERK # 10
P
TO DESTINED PRESET KEY
M
ASSIGN CLERK # 0
P
TO DESTINED PRESET KEY
M
S
S
Note 1: Clerk data allow replace the preset keys are already assigned for PLU Number but cannot replace the preset
keys are already assigned for Function Key, Clerk Key or Preset Tare.
Note 2: If you want to delete the Clerk key are assign to the Preset key, please refer to Delete Preset Key
Assignment or Delete Function Key Assignment.
AM
CH
PE
AM
CH
PE
3) Set other Clerk key to preset key if necessary. If not, back to PLU # Assignment Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
ASSIGN PLU # 0
P
TO DESTINED PRESET KEY
M
S
AM
CH
PE
78
SM-300 Operation Manual (Advance)
3. Function Key Assignment
Function Keys File
To use the following function keys, the function keys should be assigned on preset key in function
assignment mode in advance.
Key To
Press
[0] CLEAR FUNCTION KEY Clear the assignment Function key or Clerk key.
[1] ADVERTISEMENT
[2] PRICE DISCOUNT
[3] PRICE % DISCOUNT
Function Remarks
Print Advertisement Message along with commodity name on
the label in MAN & PPK Mode. (SPEC 67 set to ENABLE)
Set Discount value from Total Price in Accumulation mode.
(SPEC68 set to ENABLE and SPEC 653 set to ALLOW)
* Total Price - Discount Value
Set the percentage of Discount from Total Price in
Accumulation mode. (SPEC69 set to ENABLE and SPEC
653 set to ALLOW)
* Total Price - Total Price x Discount %
Set Discount value from Unit Price in Registration. (SPEC 70
[4] U.PRICE DISCOUNT
[5] U.P. % DISCOUNT
set to ENABLE)
* Unit Price - Discount Value
Set the Percentage of discount from Unit Price in
Registration. (SPEC 71 set to ENABLE)
Unit Price - Unit Price x Discount %
*
[6] PACK DATE
[7] - PACK DATE
[8] SELL BY DATE
Change the packed date on label in MAN & PPK mode.
(SPEC 72 set to ENABLE & for MANUAL Mode, SPEC
654 must set to ALLOW).
* Packed date = Actual Date + Entered days.
Change the packed date on label in MAN & PPK mode.
(SPEC 73 set to ENABLE & for MANUAL Mode, SPEC
654 set to ALLOW).
* Packed date = Actual Date - Entered days.
Change the sell by date on label in MAN & PPK mode.
(SPEC 74 set to ENABLE)
* Sell by Date = Actual Date + Entered days.
79
SM-300 Operation Manual (Advance)
Key To
Press
Function Remarks
Change Unit Symbol for Non-weighing item in PPK mode.
[9] QUANTITY SYMBOL
(SPEC 75 set to ENABLE & change Unit Symbol for NonWeight Item in MANUAL Mode, SPEC 169 set to PRN IN
MAN MODE).
[1][0] QUANTITY
[1][1] UNIT PRICE CHANGE
Change Quantity for Non-weighing item in PPK mode. (SPEC
76 set to ENABLE).
Change Unit Price in MAN & PPK mode. (SPEC 77 set to
ENABLE).
[1][2] REFUND Refund the item in MAN Mode. (SPEC 78 set to ENABLE)
[1][3] SHOP NAME
[1][4] LOGO
Change Shop Name for Label in MAN & PPK mode. (SPEC
79 set to ENABLE & SPEC 26 set to PRINT).
Change Logo for Label in MAN & PPK mode. (SPEC 80 set
to ENABLE).
[1][5] SELECT RPINT ITEM
[1][6] SUB-TOTAL
[1][7] GRAND TOTAL
[1][8] PACK QUANTITY
[1][9] PRICE MARKDOWN
[2][0] PRICE % MARKDOWN
[2][1] U. PRICE MARKDOWN
Select PLU data to be printed on label in MAN & PPK mode.
(SPEC 81 set to ENABLE).
Print Sub-Total label of the packed item in PPK mode. (SPEC
84 set to ENABLE).
Print Grand Total label of the packed item in PPK mode.
(SPEC 85 set to ENABLE).
Set the number of Pack Quantity in PPK mode. (SPEC 66 set
to ENABLE).
Set Markdown Price in MAN & PPK mode. (SPEC 105 set to
ENABLE and SPEC 653 set to ALLOW).
* Total Price = Mark Down Value
Set Total Price by entering Markdown % in MAN & PPK
mode.
(SPEC 106 set to ENABLE and SPEC 653 set to ALLOW).
* Total Price = Total Price x Mark Down %
Set Markdown Unit Price in MAN & PPK mode. (SPEC 107
set to ENABLE)
* Unit Price = Mark Down Value
80
SM-300 Operation Manual (Advance)
Key To
Press
Function Remarks
[2][2] U. P. % MARKDOWN
[2][3] UNIT PRICE STORE
[2][4] PLACE
[2][5] LABEL FORMAT 1
[2][6] LABEL FORMAT 2
[2][7] PREPACK NON ADD
[2][8] MAIN GROUP NUMBER
Set Unit Price by entering markdown % in MAN & PPK
mode. (SPEC 108 set to ENABLE)
* Unit Price = Unit Price x Mark Down %
Store the unit Price entered in registration mode into the PLU.
(SPEC 103 set to ENABLE).
Print the place of production of Commodity on label. (SPEC 82
set to ENABLE).
Change Label format 1 in MAN & PPK Mode.
(SPEC 146 set to ENABLE).
Change Label format 2 (Free Format Label only) in MAN &
PPK Mode. (SPEC 146 set to ENABLE).
Print packed Item Non-Add in Grand Total in PPK Mode.
(SPEC 147 set to ENABLE)
Enter Main Group Number for Manual Price Entry in MAN
& PPK Mode. (SPEC 149 set to ENABLE).
[3][1] SET MANUAL WEIGHT
[3][2] ITEM CODE
[3][4] EURO CURRENCY SW
[3][5] SWITCH KEY
[3][7] REFERENCE PLU
[3][8] PRINT KEY
[3][9] PLU REPEAT
[4][0] FLAG CODE
Set Manual Weight for Weight Item in PPK Mode. (SPEC
677 set to ENABLE).
Change the Item Code on Label in MAN & PPK Mode.
(SPEC 162 set to ENABLE).
To display Euro Second Price in Reg. Mode. (SPEC 171 set
to EURO)
Switch Unit Price of Weight Item to Non-Weight Item and
vice verse.(SPEC 185 set to ENABLE)
To call up Reference PLU when the PLU program with
Reference PLU Number in MAN & PPK Mode. (SPEC 204
set to ENABLE).
Print Label in MAN & PPK or Receipt in Acc. Mode. (SPEC
205 set to ENABLE).
Repeat the PLU after print in MAN Mode. (SPEC 210 set to
ENABLE).
Change the Flag Code on Label in MAN & PPK Mode.
(SPEC 213 set to ENABLE).
81
SM-300 Operation Manual (Advance)
Key To
Press
Function Remarks
[4][1] CASH DRAWER OPEN
[4][2] TAX INFORMATION
[4][3] UP OVERRIDE PASSWD
[4][5] 1/2 PRICE KEY
[4][6] CHEQUE TENDER KEY
[4][7] VOUCHER TENDER KEY
[4][8] DIRECT DISCOUNT
Open Cash Drawer with out SALES in MAN & PPK Mode.
(SPEC 222 set to ENABLE).
Print Tax Information on Receipt paper. (SPEC 221 set to
ENABLE).
Change Unit Price in MAN & PPK Mode. (SPEC 227 set to
ENABLE).
Half Price for Non-Weight Item in MAN & PPK Mode.
(SPEC 237 set to ALLOW).
Payment in Amount Tender Mode. (SPEC 239 set to
ENABLE).
Payment in Amount Tender Mode. (SPEC 240 set to
ENABLE).
PLU of Unit Price or Unit Price % Discount in MAN & PPK
Mode. (SPEC 242 set to ENABLE).
[4][9] INGREDIENT Change the Ingredient Data on Label in MAN & PPK Mode.
[5][7] CREDIT KEY
Payment in Amount Tender Mode. (SPEC 239 set to
ENABLE).
[5][8] BATCH FILE PRT To print a / few particular PLUs at one time.
[5][9] BORN COUNTRY
[6][0] FATTEN COUNTRY
[6][1] SLAUGHTER HOUSE
[6][2] CUTTING HALL
[6][3] REFERENCE NO
[6][4] ORIGIN COUNTRY
Change Born Data on Label in MAN & PPK Mode. (SPEC
258 set to YES)
Change Fatten Data on Label in MAN & PPK Mode. (SPEC
258 set to YES)
Change Slaughter House ID and Country Data on Label in
MAN & PPK Mode. (SPEC 258 set to YES)
Change Cutting Hall ID and Country Data on Label in MAN
& PPK Mode. (SPEC 258 set to YES)
Change Reference Number (Date or Free Code) on Label in
MAN & PPK Mode. (SPEC 258 set to YES)
Change Origin Country on Label in MAN & PPK Mode.
(SPEC 258 set to YES)
82
SM-300 Operation Manual (Advance)
Key To
Press
Function Remarks
[6][5] TRACEABILITY SET
[6][6] TRACEABILITY NO
[6][9] LBL/RCT SWITCH KEY
[7] [1] TRACE UPDATE FUNC
[7] [6] INVENTORY FUNCTION
[7] [7] TRACEABILITY CLEAR
[7] [8] SP MSG FUNCTION
Change All Traceability Data on Label in MAN & PPK Mode.
(SPEC 258 set to YES)
Change the Traceability Data on Label in MAN & PPK
Mode. (SPEC 258 set to YES)
To switch label mode to receipt mode or receipt mode to
label mode in MAN & PPK MODE.
To update Traceability number to PLU File. (SPEC 298 set
to YES)
To select Inventory Mode in Registration Mode.
To clear Traceability Information printing in Registration
mode.
Change the Special Message Data on Label in MAN & PPK
Mode.
[7] [9] DATE PRINT FUNC
To disable or enable Sell-by Date and Packed Date on Label
in MAN & PPK Mode.
[8] [1] FUNC:CASH IN/OUT To Cash IN or OUT in MAN & PPK Mode.
[8] [2] PRINT SELL BY DATE
To disable or enable Sell-by Date on Label in MAN & PPK
Mode.
[8] [4] PRINT PLU TTL REPORT Print PLU Report in Registration Mode.
[8] [5] PRINT RECEIPT To disable or enable Receipt printing.
[8] [6]
LABEL PRT W/O
REPORT
Print item label without update Transaction data to Report.
83
SM-300 Operation Manual (Advance)
Function Key Assignment
Function keys are used to change the original programmed data (unit price, advertisement message, sell by
date, etc.) at one touch operation, when issuing labels. Using function keys, operator can issue necessary
labels speedier, convenient without suffering the work and time loss to reset the data.
There are two ways to select the Function Key Type by using different keys such as:
• Enter the number of the Function Key.
• Press [X] or [−] key to search the Function Key.
1) At PLU # Assignment Mode, enter the Assign Function Key Assignment Mode.
KEY TO PRESS DISPLAY
¼O
»
ASSIGN FUNCTION KEY
P
X-> CLEAR FUNCTION KEY
M
NET
2) Select PRICE DISCOUNT function by search and then assign to Preset Key number 25.
S
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
ASSIGN FUNCTION KEY
P
X-> PRICE DISCOUNT
M
ASSIGN FUNCTION KEY
P
X-> CLEAR FUNCTION KEY
M
S
S
3) Select UNIT PRICE CHANGE function by entering number of the function key and then assign to
Preset Key number 26.
# Assignment Mode.
* Set each function key to preset key if necessary. If not, press [PLU] key back to PLU
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
ASSIGN FUNCTION KEY
P
X-> UNIT PRICE CHANGE
M
ASSIGN FUNCTION KEY
P
X-> CLEAR FUNCTION KEY
M
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
AM
CH
PE
Note: Function Key allow replace the preset keys are already assigned for PLU Number but cannot replace the
preset keys are already assigned for Function Key, Clerk Key or Preset Tare.
84
SM-300 Operation Manual (Advance)
85
SM-300 Operation Manual (Advance)
Delete Function Key Assignment
There are two different ways to delete the Function Key assignment on preset keys. The following
operation as below is to delete the Preset Key Assignment for Function Key, Clerk key and Preset Tare in
Function Key Assignment. For another way to delete the Function Key assignment, please refer to Delete
Preset Key Assignment at PLU Assignment.
Note: If the PLU Number assign to the Preset Key, the preset key cannot be delete in Function Key Assignment.
1) At Function Key Assignment.
KEY TO PRESS DISPLAY
¼O
»
NET
ASSIGN FUNCTION KEY
P
X-> CLEAR FUNCTION KEY
M
2) Press the Preset Key to be deleted (Ex. [P1] for Clerk # 10).
S
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
DELETE CLERK
P
PRESS: C(YES) / T(NO)
M
3) Delete the Preset Key Number 1.
*If you want to cancel deletion, press [TARE] key.
KEY TO PRESS DISPLAY
¼O
»
NET
ASSIGN FUNCTION KEY
P
X-> CLEAR FUNCTION KEY
M
4) Delete others preset key assignment if necessary. If not, back to PLU # Assignment Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
ASSIGN PLU # 0
P
TO DESTINED PRESET KEY
M
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
86
SM-300 Operation Manual (Advance)
4. Macro Keys Assignment
Macro function key is used to recall operation done during Macro mode.
For example:
Number 17.
1) At PLU # Assignment Mode, enter to Preset Keys + PLU Key to Assign Macro Mode.
KEY TO PRESS DISPLAY
2) Assign Macro Function Key (Preset Keys + PLU Key to Assign Macro) to Preset Key you wants (Ex.
[P17]). * It goes to Registration Mode, but it actually in Macro Mode.
Assign Macro function key (Preset Keys + PLU Key to Assign Macro) to Preset Key
¼O
»
NET
PRESET KEYS + PLU KEY
P
TO ASSIGN MACRO
M
S
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
W
»
NET
0.000 0.000.00
P
0.000
M
W
R
AM
CH
PE
3) Do any operation (without touching PLU key) Ex. Call up PLU and Print, change between mode, do
accumulation.
KEY TO PRESS DISPLAY
and then
and then
¼O
»
NET
¼O
»
NET
¼O
»
NET
0.200 25.005.00
P
0.000 FRIED POTATOES
M
W
TO CLEAR DAILY TRANS
P
PRESS PRINT KEY
M
CLERK #9996: 5 ITEMS
P
PRICE : 13.23
M
W
R
Z
R
B
AM
CH
PE
AM
CH
PE
AM
CH
PE
4) Press PLU key to Store operation and go to Registration Mode.
KEY TO PRESS DISPLAY
¼O
»
PRESET KEYS + PLU KEY
87
R
SM-300 Operation Manual (Advance)
NET
¼O
»
NET
P
TO ASSIGN MACRO
M
W
0.200 0.000.00
P
0.000
M
W
R
AM
CH
PE
AM
CH
PE
5) Press key that Assign been assign Macro Function Key (Preset Keys + PLU Key to Assign Macro) (Ex.
[P17]). * It redoes operation done in the Macro Mode
KEY TO PRESS DISPLAY
¼O
»
NET
0.200 25.005.00
P
0.000 FRIED POTATOES
M
W
R
AM
CH
PE
88
SM-300 Operation Manual (Advance)
5. Payment Key Assignment
Payment key is used to control printing usage, printing type and printing information made for
registration, accumulation (subtotal) and change mode. If you want to use payment key, you need to
assign the programmed payment keys
For example:
Assign Payment Number 20 to Preset Key Number 17.
1) At PLU # Assignment Mode, enter to Payment Assign Mode.
KEY TO PRESS DISPLAY
2) Enter Clerk Number 20 by numeric key and assign to Preset Key you want (Ex. [P17]).
on preset keys in advance
¼O
»
NET
PAYMENT ASSIGN 0
P
PAYMENT # AND PRESET
M
S
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
»
NET
PAYMENT ASSIGN 20
P
PAYMENT # AND PRESET
M
PAYMENT ASSIGN 0
P
PAYMENT # AND PRESET
M
S
S
Note 1: Payment data allow replace the preset keys are already assigned for PLU Number but cannot replace the
preset keys are already assigned for Function Key, Clerk Key, Payment Key or Preset Tare.
Note 2: If you want to delete the Payment key assign to the Preset key, please refer to Delete Preset Key
Assignment or Delete Function Key Assignment.
AM
CH
PE
AM
CH
PE
89
SM-300 Operation Manual (Advance)
6. Preset Tare Assignment
Preset Tare is to use to program a knowing Tare value in advance for Registration Mode to call up by
pressing the assigned Preset Key (Such as Digital Tare operation). To use the Preset Tare value, SPEC 647: PLU TARE must set to ALLOW in advance and maximum Tare Weight can be assign to the preset
Key is depending on SPEC 638: TARE RANGE setting.
1) At PLU # Assignment Mode, enter the Assign Preset Tare Mode.
KEY TO PRESS DISPLAY
¼O
»
TARE ASSIGN 0
P
TO DESTINED PRESET KEY
M
NET
2) Enter Tare value you want (Ex. 50g) and assign to the Preset Key you want (Ex. [P27]).
KEY TO PRESS DISPLAY
¼O
»
TARE ASSIGN 50
P
TO DESTINED PRESET KEY
M
»
TARE ASSIGN 0
P
TO DESTINED PRESET KEY
M
NET
¼O
NET
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
PE
Note 1: Preset Tare allow replace the preset keys are already assigned for PLU Number but cannot replace the
preset keys are already assigned for Function Key, Clerk Key or Preset Tare.
Note 2: If you want to delete the Preset Tare are assign to the Preset key, please refer to Delete Preset Key
Assignment or Delete Function Key Assignment.
3) Set other Tare value to preset key if necessary. If not, back to PLU # Assignment Mode.
KEY TO PRESS DISPLAY
¼O
»
NET
ASSIGN PLU # 0
P
TO DESTINED PRESET KEY
M
S
AM
CH
PE
90
SM-300 Operation Manual (Advance)
Shop Name File
Shop Name data will be printed on Label or Receipt can be programmed in this file. The maximum number
of characters possible to enter varies according to the size of print area or character size entry. Up to 32 Shop
Names can be programmed with each 3 lines as maximum and number of line is depends on the Character
Size entry.
The default Shop Name print on label can be set at SPEC 46 & print centering of shop name on label can be
select at SPEC 250 and default Shop Name print on Receipt can be set at SPEC47 & printing position can
be select at SPEC251.
1. Program Shop Name File
1) At Programming Mode, select Shop Name programming mode and then enter new Shop Name
number (Ex. 3) programming mode.
KEY TO PRESS DISPLAY
st
2) Enter 1
line of Shop Name data as the same procedure as Commodity Name entry (Ex. DIGI
STORE) and save it.
*For edit, enter existing Shop Name number.
¼O
»
SHOP NAME
NET
PROGRAMMING
P
ENTER SHOP #(1-32): 0
M
¼O
»
NET
SHOP NAME #0003 P:KEY
P
S4/47/01:
M
S
S
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
SHOP NAME #0003 P:KEY
P
W
S4/37/01:DIGI STORE
M
»
SHOP NAME #0003 P:KEY
P
W
S4/47/02:
M
• • • • • •
NET
¼O
NET
3) Enter Shop Name data in the 2
[CHANGE] key follow by [CLEAR] key.
nd
line if necessary. If not, save it. *If you want to exit without saving, press
KEY TO PRESS DISPLAY
¼O
»
SHOP NAME
NET
PROGRAMMING
P
91
S
S
S
AM
CH
PE
AM
CH
PE
AM
CH
SM-300 Operation Manual (Advance)
M
PE
92
SM-300 Operation Manual (Advance)
2. Print Shop Name File
The Shop Name report can be printed on receipt paper. You can print a FULL Report that includes all
programmed Shop Names or print a Single Report that only includes one Shop Name data.
Single Report Printing
1) At Shop Name programming mode, enter existing Shop Name Number (Ex. 3) then print out report
*If you want to stop printing, press [FEED] key.
KEY TO PRESS DISPLAY
¼O
»
SHOP NAME
NET
¼O
»
NET
¼O
»
NET
PROGRAMMING
P
ENTER SHOP #(1-32): 0
M
PRINTING,,,
P
M
SHOP NAME
PROGRAMMING
P
ENTER SHOP #(1-32): 0
M
Full Report Printing
1) At Shop Name programming mode, print out full report.
S
S
S
*If you want to stop printing, press [FEED] key.
AM
CH
PE
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
NET
¼O
NET
PRINTING,,,
P
M
»
SHOP NAME
PROGRAMMING
P
ENTER SHOP #(1-32): 0
M
93
S
S
AM
CH
PE
AM
CH
PE
SM-300 Operation Manual (Advance)
3. Delete Shop Name File
1) At Shop Name programming mode, enter existing Shop Name Number (Ex. 3) to be deleted.
KEY TO PRESS DISPLAY
¼O
»
SHOP NAME
NET
PROGRAMMING
P
ENTER SHOP #(1-32): 3
M
2) Enter deleting mode.
KEY TO PRESS DISPLAY
¼O
»
NET
DELETE?
P
PRESS: C(YES) / T(NO)
M
3) Delete Shop Name Number 3.
*If you want to cancel the deletion, press [TARE] key to exit.
S
S
AM
CH
PE
AM
CH
PE
KEY TO PRESS DISPLAY
¼O
»
SHOP NAME
NET
PROGRAMMING
P
ENTER SHOP #(1-32): 0
M
S
AM
CH
PE
94
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.