Digi MIL-02F Installation Manual

Page 1
MIL•02F
Fiber•MAU FDX
Full-Duplex Fiber Optic
Transceiver
FIBER•MAU
Model: MIL•02F
ETHERNET FULL-DUPLEX
10BASE-FL
TRANSCEIVER
Power Required: 12 VDC 200 ma
FCC PART 15 CLASS A
COMPLIANT
CX
TX RX
PWR
TX RX
LINK
This guide includes the following information:
“Introduction” on page 2 “Installation” on page 2 “Configuration” on page 2 “DIP Switch” on page 2 “Jumper Settings” on page 3 “Diagnostic LEDs and Conditions Indicated” on page 3 “Legal” on page 4
With LinkSentry™
Ethernet/IEEE 802.3
Doc #: 90000108 Rev. A
Page 2
Install Guide
Introduction
The MIL-02F is an Ethernet, multi-mode fiber transceiver that comes equipped with diagnostic LEDs, an AUI male connector, and either an SC- or ST-type fiber connector.
Installation
1. Connect the fiber cables: Attach the fiber cables from the fiber network cabling to the fiber connectors on the MIL-02F.
2. Attach the 15-pin AUI connector from the MIL-02F to the DB-15 connector on the device you wish to connect to.
3. Tighten the latch screws to secure the unit.
4. Restart the computer. The
Note:
If the
PWR
LED did not illuminate, reinstall the MIL-02F. If it still does not illuminate , contact
our technical support department.
LED illuminates.
PWR
Configuration
The MIL-02F comes with configurable options, which include a 2-position DIP switch and a 3-pin jumper. The DIP switch is located on left-side of MIL-02F (while facing the device), and the jumper is located inside the device. To open the MIL-02F to access the 3-pin jumper:
1. For device's with ST-type connectors,u nscr ew the two hex nuts that secur e the ST-type connectors.
2. Slide the top-half of the enclosure off, over the fiber connectors.
The jumper is located on right-hand side of the device (Figure 1).
DIP Switch
The Link Sentry feature on the MIL-02F is configured through the 2-position DIP switch located on the side of the transceiver . Use a mechanical pencil to adjust the DIP switches.
LinkSentry transmits link pulses only if the receive side of the link is seen. This allows fault-tolerant transceivers and hubs to detect faulty cables or bad equipment. Settings for the DIP switch includes:
Switch 1 LinkSentry disabled (Default) LinkSentry enabled Switch 2 SQE disabled (Default) SQE enabled
Model: MIL-02F 2
Table 1: DIP Switch Settings
Up (off) Down (on)
Page 3
Install Guide
Jumper Settings
The 3-pin jumper forces the device into half- or full-duplex operation.
When pins 1 and 2 are covered, full-duplex is selected
When pins 2 and 3 are covered, half-duplex is selected (default)
DIP Switch
3-Pin jumper (with a jumper block installed)
Figure 1.Inside the MIL-02F
Diagnostic LEDs and Conditions Indicated
PWR (Power): Device is receiving power.
TX (Transmit): Packets are being transmitted over the network.
CX (Collision): Collisions are occurring on the network.
RX (Receive): Packets are being received from the network.
LINK (Link): The fiber optic link is good.
Model: MIL-02F 3
Page 4
Legal
Regulatory Approvals
FCC Class A
UL 1950
CSA 22 No. 950
EN60950
CE
– EN55022 Class B – EN50082-1
Canadian EMI Notice
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
European Notice
Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the commission of the European Community. Compliance with these directives implies conformity to the following European Norms:
EN55022 (CISPR 22) - Radio Frequency Interference
EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity
EN60950 (IEC950) - Product Safety
Digi International warrants to the original consumer or purchaser that each of its products, and all components thereof, will be free from defects in material and/or workmanship for a period of five years from the original factory shipment date. Any warranty hereunder is extended to the original consumer or purchaser and is not assignable.
Digi makes no express or implied warranties including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose, except as expressly set forth in this warranty. In no event shall Digi be liable for incidental or consequential damages, costs, or expenses arising out of or in connection with the performance of the product delivered hereunder. Digi will in no case cover damages arising out of the product being used in a negligent fashion or manner.
To Contact Digi
For prompt response when calling for service information, have the following information ready:
Product serial number and rev.
Date of purchase
Vendor or place of purchase
Reach Digi Technical Support at 408/744-2751 Or E-mail at “sun-tech@dgii.com”
Address: 1299 Orleans Drive
Sunnyvale, CA 94089 Voice: 408/744-2775 Fax: 408/744-2793 E-mail: info@dgii.com
Five-Year Limited Warranty
Doc #: 90000108 Rev. A