26
Unit Weight Entry
DIGITAL ENTRY
25. Enter Unit Weight Value with numeric
keys Ex.) 3.756kg/1000pcs.
(5) 3.756
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8
26. Press [UNIT WEIGHT] key. *1
* 0.0000 3.7560 0
∇ ∇ ∇
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8
UNIT WEIGHT SAMPLING
25’. Place sample pieces on scale.
Ex.) 0.015kg
* 0.0150 0. 0
∇ ∇
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8
26’. Enter sample number with numeric keys.
*2 Ex) 15
(2) 15
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8
27’. Press [PIECES] key. *3
---ADD 12
(The number of pieces needed appears in
display.)
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8
28’. Add the required pieces more and press
[PIECES] key again.
* 0.0270 0.9970 27
∇ ∇
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8
Note: *1) The unit weight value should be Unit Weight/1,000.
Note: *2) If using a sample of 10 pcs., press PIECES key without entering a number of
sample.
Note:*3) To have accurate unit weight calculation, the sample weight must be more
than the insufficient range of the scale. (Insufficient range = 0.0% ~ 0.7 % of
scale capacity) If sample weight is less than the range, the number of pieces
required for accurate sampling would be displayed in PROCEDURE 27.
The procedure on 27 and 28 will be skipped if sample weight is sufficient.