4. Attach the cables from the peripheral devices to the SCSI Terminal
Server.
5. Connect the power supply and/or power cord to an AC outlet.
6. Power up the network server and its peripherals.
7. Check to see that the SCSI Terminal Server is operating correctly.
Note: See the Troubleshooting section below for common installation problems.
Rack Mount Installation
For the SCSI Terminal Server 1032, a rack mount kit is included. The
rack mount brackets may be installed at either the front or rear of the unit.
To install each bracket, do the following:
1. Remove the two screws on the side of the cabinet.
CAUTION: To prevent electric shock, do not remove the module
cover. There are no user-serviceable parts inside. Refer
servicing to qualified personnel only.
2. Align the holes of the bracket with the vacated holes in the cabinet.
Use the screws to fasten the bracket to the cabinet.
Rack Mount Considerations
When doing a rack mount installation consider the following:
• Cumulative power requirements of the unit and other equipment
installed in the rack. Do not overload rack supply circuits.
• Safety and stability. Always stack the rack from bottom up to ensure
a stable and safe rack.
• Air flow in the rack. Make sure the unit’s ambient temperature does
not exceed 95°F (35°C).
• Grounding. Earth ground the unit reliably to the rack system. The
earth ground connection must be maintained when the supply connection is other than a direct connection to the branch circuit.
EIA - 232 Connectors
Many EIA-232 serial devices implement their serial ports with DB-25
connectors. The SCSI Terminal Server units have serial ports implemented with 8-pin RJ-45 modular jacks, with each signal using EIA-232
voltage levels. The figures below shows the pinouts of all these connector
types
Note: The SCSI Terminal Server RJ-45 pin configuration is different
from the configuration of the RJ-45 connectors used on other Digi products. RJ-45 cables designed for other Digi products must not be used
with Digi SCSI Terminal Server.
EIA-232 DTE and DCE Pinouts
Troubleshooting
If the SCSI Terminal Server does not operate properly, check the list
below for some common installation problems
.
• The most frequent problem is duplicate SCSI ID numbers. The SCSI
adapter card is usually set to #7. Make sure the SCSI Terminal
Server module ID number is not conflicting with that number.
• Check the cable to see that it is properly inserted and is completely
seated. The pins in the SCSI cable are delicate and can be easily bent
if not inserted carefully. It might be necessary to disconnect the cable
to inspect for bent pins.
• Inspect the power cord to verify it is inserted completely and the
power is turned on.
Software License Agreement
LICENSE. Digi grants to you only a non-assignable, nonexclusive and non-transferable license to use the
software contained on this media (her ei n after “Digi Software”) subject to the terms and conditions of this
Software License Agreement. Your use will be limited to an object code version of the Digi Software.
Your use of the Digi Software will be limited to one computer. The license will commence on the day you
receive the Digi Software and will continue until this license is terminated by its own terms and conditions. You may make one copy of the Digi Software, but only for archival or backup purposes, and if you
do make that additional copy, you agree to reproduce all copyright and other proprietary rights notices that
appear on the Digi Software. You are granted only a limited license to use the Digi Software, and Digi
retains all right, title, interest and ownership in and to the Digi Software, which includes all rights arising
under the patent, copyright, trade secret or trademark laws of the United St ates or any foreign jurisdiction.
CONFIDENTIALITY
. You unders t and and agree that the Digi Software contains valuable confidential
and trade secret information which is the extremely valuable property of Digi. You agree to expend all
necessary efforts to ensure that the Digi Software is not disclosed or made av ailable to any third party or
any employee or contractor that doesn’t have a need to know.
REVERSE ENGINEERING
. YOU AGREE NOT TO DISASSEMBLE, DECOMPILE OR REVERSE
ENGINEER THE DIGI SOFTWARE UNDER ANY CIRCUMSTANCES.
WARRANTIES
. Digi warrants only that: (a) the media upon which you receive DIGI Software will be free
of defects in material and workmans hip for a period of ninety (90) days from your receipt of the DIGI
Software; and (b) that if the DIGI Software is supplied to you electronically, and there is an error in transmission, and you inform us of that error within ninety days of your receipt of the DIGI Software, Digi will
re-transmit the Software to you. You understand and agree that except as stated above, the DIGI Software
is supplied as is, and Digi expressly disclaims all other warranties, guarantees, or remedies whether
express, implied or statutory, including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose.
LIABILITY LIMITATIONS
. Under no circumstances will Digi or any of its distributors or suppliers be
liable for loss of data, re procu reme nt co sts, lost re ven ue o r pro fi ts or a ny oth er sp eci al, inci den tal or co ns equential damages, even if those damages were foreseeable or you have informed Digi of a potential liability. Digi’s total liability to you for damages for any reason shall not exceed the price actually paid to Digi
by you for the product associated wit h th e Software.
TITLE AND OWNERSHIP
. You acknowledge and agree that Digi retains all right, title and interest in and
to the Software. You agree to indemnify, defend and hold harmless Digi against any loss suffered or
expenditure made by Digi arising from an assertion of an interest in or title to the Digi Software by you
and against any breach by you of any copyright , patent rights, or any other rights in the Digi Software.
TERMINATION
. You acknowle dge and agree that Digi may terminate your license and use of the Digi
Software without notice if, at any time, you fail to comply with a material term or condition of this Software License Agreement. Immediately upon termination of this license, you will return all copies of the
Digi Software to Digi, together with all documentation, modifications and enhancements thereto, or at
Digi’s request, destroy all copies of the Digi Software documenta t ion, modifications and enhancements in
your possession. You understand and agree that in the event of termination, Digi may use computer hardware, software or other methods to render the Digi Software inoperable.
ASSIGNMENT
. You may not assign this license without the prior written consent of Digi. Digi may
assign the Digi Software to any third party at its discretion, but will provide you with written notice in the
event of such assignment.
CHOICE OF LAW AND VENUE
. This Software License Agreement shal l be governed and construed in
accordance with the laws of the State of Minnesota. Any controversy or claim arising out of or related to
this license and/or your us e of th e Dig i So ftware s hal l b e ve nue d in Min nesot a St at e D istr ic t Cour t, Cou nty
of Hennepin or the United States Distri ct Court for the District of Minnesota.
MAINTENANCE AND SUPPORT
. Any software maintenance or support services provided to you by
Digi, are provided at Digi’s discretion, and Digi reserves the right to di scontinue and/or commence charg-
ing fees for maintenance or support services at any time. YOU ALSO UNDERSTAND AGREE THAT
ANY MAINTENANCE OR SUPPORT SERVICES PROVIDED TO YOU BY DIGI ARE PROVIDED
AS IS, AND DIGI MAKES NO REPRESENTATIONS OR WARRANTIES WITH REGARD TO
THOSE SERVICES.
Proprietary Rights N o t ice
Digi, Digi Internation al , t he Di gi log o, Re alPo r t an d Por tS er ver ar e trade ma rk s or reg ist e red tr ade mark s of
Digi International Inc. in the Unite d States and other countries. All other brand and product names are
trademarks or registered t rademarks of their respective holders.
This manual is copyrighted material proprietary to Digi International Inc. Copying of this manual without
the express written consent of Digi International Inc. is prohibited and will be treated as copyright
infringement.
Copyright
© 2000 Digi International Inc. All Rights Reserved. http://www.digi.com
Disclaimer
This manual may contain inaccurate or erroneous information. This manual is subject to change at any
time. This manual, including all information contained herein, is provided “as is” without warranty of
any kind, either express or implied, including, but not limited to, any implied warrantees of merchantability or fitness for particular purpose. Digi International Inc. makes no representations, warranties, or
commitments with regard to any data or information contained in this manual. If you rely on data or
information contained in this manual, such reliance is at your own risk.
RJ-45 Pin Signal DB-25 Pin DTE Use DCE Use
1 RTS (out) 4 output input
2 DSR (in) 6 input output
3 DCD (in) 8 input output
4 RxD (in) 3 input output
5 TxD (out) 2 output input
6 SG 7 ground ground
7 DTR (out) 20 output input
8 CTS (in) 5 input output
13
1
14
25
Ma le D B-25
13
1
14
25
Female DB-2 5