DieHard Portable Power 1150 Operator's Manual

Page 1
OPERATOR'S MANUAL
®
Portable Power 1150
Jump Starter/DC Power Source Air Compressor, inflator and AC Power
Model No.
200.71988
Read all Safety Rules and Operating Instructions, and follow them with each use of this product.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
00-99-000865/0808
Page 2
SECTION PAGE
1. iMPORTANT SAFETY iNSTRUCTiONS 1
2. PRODUCT FEATURES 2
3. CHARGING THE iNTERNAL BATTERY 3
4. JUMP-STARTING AVEHICLE ENGINE 4
5. DiGiTAL DISPLAY FUNCTIONS 5
6. POWERING A 12V DC DEVICE 5
7. USING THE USB PORT 6
8. USING THE BUILT-IN LIGHT 6
9. iNTERNAL BATTERY REPLACEMENT 7
10. USING THE AiR COMPRESSOR 7
11. USING THE iNFLATOR 8
12. ESTIMATED TiME FOR iNFLATiNG 8
13. USING THE DEFLATOR 8
14. BEFORE USING THE iNVERTER 9
15. USING THE iNVERTER 9
16. POWERING THE 110VAC DEVICE 10
17. EXAMPLE RUN-TIME CHART 10
18. STORAGE AND MAINTENANCE 11
19. SPECiFiCATiONS 12
20. AC POWER SPECiFiCATiONS 12
21. REPLACEMENT PARTS 12
DieHard One-year Full Warranty
When operated and maintained according to all supplied instructions, if this DieHard product fails due to a defect in material or workmanship within one year from the date of purchase, return it to any Sears store or other DieHard outlet in the United States for free replacement.
This warranty does not include light bulbs, or the inflator hose and adapters, which are expendable parts. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co., Hoffman Estates, IL 60179
FOR CUSTOMER ASSISTANCE OR REPLACEMENT PARTS, CALL TOLL-FREE BETWEEN 7 AM TO 4:30 PM CT
MONDAY THROUGH FRIDAY: 1-800-SEARS-64 (1-800-732-7764)
CONTAINS SEALED NON-SPILLABLE LEAD=ACID
BATTERY. MUST BE DISPOSED OF PROPERLY.
WARNING: Possible explosion hazard. Contact with
battery acid may cause severe burns and blindness. Keep out of reach of children.
Page 3
iMPORTANT: CHARGE iMMEDiATELY AFTER PURCHASE
IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL.
1.1 Charge the 1150% internal battery immediately upon purchase, every 30 days and after every use.
1.2 Use in a welt ventilated space.
1.3 Contains a sealed, non-spitlable lead-acid battery. Must be disposed of properly.
1.4 WARNING: Possible explosion hazard. Contact with battery acid may cause severe burns and blindness. Keep out of reach of children.
1.5 WARNING: Pursuant to California Proposition 65, this product contains chemicals known to the State of California to cause cancer and birth de-
fects or other reproductive harm.
1.6 WARNING: Failure to follow instructions may cause damage or an explo- sion. Read entire instruction manual before use. Always wear safety glass- es to protect your eyes during use.
.1.
Page 4
16
21
3 8
19 13
20
14 12
11
1. JUMP START ON/OFF Switch. Turn on to activate clamps and
USB.
2. Inverter/Compressor switch. This switch turns the inverter or air
compressor on and off.
3. Digital Display - indicates internal and vehicle's battery percentage of
charge and displays a code when improperly connected to battery.
The display also shows power out
when using the inverter.
4. Plastic lens cover
5. Two, light bulbs
6. Two, 12V DC power outlets
7. Two, 110VAC household power outlets.
8. USB port
9. Power Switch (Light/Display). This switch turns on the light or the in-
ternal battery status digital display.
10. Air compressor gauge
11. Air compressor hose
12. Air compressor accessory bag
13. Air compressor ball inflation adapter
14. Two, air compressor miscella- neous inflation adapters
15. ON/OFF inflator/deflator switch
16. High-flow inflator outlet
17. Inflator/deflator hose end adapter
18. High-flow deflator outlet
19. Inflator/deflator hose
20. Two cables with clamps
21. Male-to-male accessory 12V charging connector
22. Three inflator/deflator hose device adapters.
23. Wall Charger
.2.
Page 5
3.1
3.2
3.3
3.4
IMPORTANT:
'_CHARGE IMMEDIATELY AFTER PURCHASE '_KEEP FULLY CHARGED.
This Portable Power 1150 comes with a sealed, non-spitlabte DieHard
maintenance-free lead-acid battery. This internal battery is specifically designed to deliver high power jump-starting as welt as repetitive deep cycling performance.
To charge the Portable Power 1150's internal battery: Check the internal battery's charge level by pressing the switch marked
DISPLAY. The Digital Display wilt show the battery's percentage. Charge if under 100%
NOTE: Internal battery's percentage is most accurate when the Portable
Power 1150 has been disconnected from all devices and charging sources for 1 - 24 hours.
To charge, plug the (external) wall charger cord into the socket on the back of the 1150. Then, plug the wall charger into a 120V AC source.
CAUTION: Operating the Portable Power 1150 while the internal battery is being charged may cause permanent damage to the unit.
While the 1150 is charging, the battery's percentage of charge wilt be displayed. When the internal battery is fully charged, the display will show
100. Complete charging may take up to 48 hours. The 1150 is then ready
to use. Once the battery is fully charged, the internal charging circuitry automati-
cally switches to float-mode monitoring, which keeps the battery fully charged without overcharging.
The internal battery may also be charged while you drive using the male- to-male accessory cable (available separately, see "Accessories and Re- placement Parts" section of this manual). Insert one end of the accessory cable into the 12V DC power outlet and the other end into the vehicle's accessory outlet (lighter socket). Completely disconnect the accessory cable when the engine is not running.
.3.
Page 6
Use in a well-ventilated area. Keep hands, hair, clothing and jewelry clear of fan blades, belts, pulleys and other parts that may cause injury.
4.1 Turn ignition off before making cable connections.
4.2 Place the 1150 on a flat, stable surface near the vehicle battery and away from moving engine parts.
4.3 Connect the red clamp to the positive (+) terminal d the vehicle battery.
4.4
4.5
4.6
NOTE: In the rare case of jump-starting a vehicle that has a positive- grounded vehicle electrical system, connect the black clamp to the negative terminal of the vehicle battery. Then connect the red clamp to an unpainted and unmoving part of the vehicle chassis or engine block. If you are unsure of the nature of the vehicle's electrical grounding system,
check the owner's manual of the vehicle or call the Customer Technical Assistance number: 1-800-SEARS-64.
Connect the black clamp to an unpainted and unmoving part of the vehicle chassis or engine block. Do not connect to the carburetor, fuel lines or sheet-metal body parts. The Digital Display displays the vehicle's voltage.
CAUTION: If you have connected the clamps backwards, an audio alarm will sound. DO NOT turn the ON/OFF switch to the ON position. This could cause serious damage. Reverse the connections and the audio alarm wilt stop.
Turn ON the JUMP START ON/OFF switch and then turn key and crank the engine. If the engine does not start within 5-8 seconds, stop cranking and wait at least one minute before attempting to start the vehicle again. This permits the battery to cool down.
After the engine starts, make sure to turn OFF the Jump Start switch. Then disconnect the black clamp (-) and then the red clamp (+) in that
order.
4.7 Recharge the 1150 as soon as possible after use. CAUTION: To prevent sparking while the 1150 jump-start switch is in the
ON position, NEVER allow the clamps to touch together or to contact the same piece of metal. Never attempt to charge a frozen battery.
.4.
Page 7
5.1 Tocheckthe1150'sinternalbattery'sstatus,pushthepowerswitchon thefrontofthe1150totheDISPLAYposition.Thedisplaywillshowthe chargepercentageoftheinternalbattery.
5.2 Whenconnectedtothevehicle,thedisplayshowsthevehicle'sbattery voltage.WhenconnectedandintheONposition,thedisplayshowsthe
equalizedvoltagebetweenthevehicle'sbatteryandinternalbattery.If thedisplaybuttonispressed,thebatterypercentageisshown(insteadof voltage).
5.3 Whentheinverteristurnedonandbeingused,thedisplaywillshowthe totalwattageusedbythedevicebeingpoweredbytheinverter.
6.1
ThePortablePower1150isapowersourceforall12voltDCaccessories thatareequippedwitha12Vaccessoryplug.TheDCaccessoryoutlet hasa15-ampautomaticoverloadprotectioncircuitbreaker.Thebreaker wiltautomaticallyresetafteranoverloadoccurs.
To Operate a 12V DC Device:
Open the protective cover of the DC power outlet on the front panel of the
Portable Power 1150.
Ptug the 12V DC device into the DC power outlet, and turn the 12V DC device "ON" (if required).
If the 12V DC device draws more than 15A, the internal circuit breaker of the Portable Power 1150 will momentarily disconnect power to the device. If this occurs, unplug the device and the circuit breaker will auto- matically reset after several seconds.
The DC power outlet is internally wired directly to the internal battery. Extended operation of a 12V DC device may result in excessive battery
drain. Recharge immediately after unplugging the device.
.5.
Page 8
5.2 12V DC Electrical Device Example Run=Time Chart
Appliance Type Estimated Power Estimated
Time*
Fluorescent Lights, Cellular Phones 4 Watts 50 Hours Radios, Depth Finders, Fans 9 Watts 25 Hours Camcorders, DVD Players, Spotlights 15 Watts 13 Hours
Electrical Tools, Bilge Pumps 24 Watts 7.3 Hours Electric Coolers 48 Watts 4.5 Hours
Air Compressors, Car Vacuums 80 Watts 2 Hour
*NOTE: Estimated run-times. Actual time may vary. Times are based on the internal battery being new, fully charged and operating at room tem- perature.
The USB port on the 1150 provides up to 500mA at 5VDC.
7.1 Turn the JUMP START ON/OFF switch to the ON position.
7.2 Plug the device into the USB port on the front panel of the 1150.
7.3 Turn USB device ON.
7.4 Reverse these steps when finished using the USB port.
8.1
8.2
8.3
8.4
Position the 1150 on a flat, stable surface near the intended work area. Push the power switch to the LIGHT position. The light will turn on and
illuminate your work area. NOTE: With a fully charged internal battery, the built-in light should pro-
vide 18 to 30 hours of continuous, useful light.
Push power switch to the OFF position when work is completed.
Charge the 1150 as soon as possible after using the built-in light.
NOTE: With a fully charged internal battery, the built-in light should
provide 18 to 26 hours of continuous useful light, depending on ambient conditions.
.6.
Page 9
The 1150 is equipped with a built in door, located on the back of the unit, to make replacing the internal battery easy and efficient.
To order a replacement battery, call: 1-800-SEARS-64.
9.1 Be sure that all switches are in the OFF position.
9.2 Remove clamps from storage pegs on the back of the 1150.
9.3 Remove eight screws from the door.
9.4 Slide door out.
9.5 Remove the negative (first) and positive nuts and bolts securing the cable to the battery.
9.6 Push cables to the side and carefully slide battery out of the 1150.
9.7 Reverse steps for assembly. Make sure that the nuts and bolts securing the cables are tight.
CAUTION: Read instructions of the product being inflated before using the compressor. Avoid over inflation, do not exceed the manufacturer's recommended pressures. Do not leave the air compressor unattended during use.
10.1 Remove the air compressor hose from the storage compartment in the back of the Portable Power 1150. Install adapters as necessary.
10.2 Attach the air compressor hose to the product or accessory to be inflated by flipping down the lever.
10.3 Place the Inverter/Compressor Switch in the compressor position and
inflate product.
10.4 When the product is inflated to the proper air pressure (using the air com- pressor gauge) place the Inverter/Compressor Switch in the OFF position
and remove the hose.
10.5 Do not run for more than 10 minutes maximum at a time. Allow the 1150 to cool down for 10 minutes before using again.
NOTE: If the compressor overheats, the built-in thermal protection will turn
the unit off. Wait a few minutes and it will automatically restart.
NOTE: The air compressor is rated for 150 PSI.
10.6 Estimated Time for Inflating
Vehicle Tires 13" to 16" 6 to 24 minutes
Bike Tire 1 to 3 minutes Sports Balls 30 seconds
Use the air compressor gauge to ensure the proper pressure has been
reached. Do not over inflate.
.7.
Page 10
11.1
CAUTION:Readinstructionsoftheproductbeinginflatedbeforeusing theinflator.Avoidoverinflation,donotexceedthemanufacturer'srecom-
mendedpressures.Donotleavetheinflatorunattendedduringuse.
Attachthecorrugatedhosewithendadaptertothehigh-flowinflatoroutlet locateddirectlyabovetheinflatorON/ OFF switch on the back of
the 1150.
11.2 The main accessory adapter attached to the corrugated hose accommo- dates up to 4 sizes. If another size is needed an additional adapter can be attached to the end of the main accessory adapter.
11.3 Insert the adapter into the product to be inflated.
11.4 Push the inflator switch to the ON position and inflate product.
11.5 When product is inflated to the desired level, push the inflator switch to the OFF position and remove the adapter.
24" Beach Ball 1 to 3 minutes
Pool Raft 4 to 6 minutes Queen-size Air Mattress 4 to 8 minutes
2 Person Boat 8 to 10 minutes
*Times may vary depending on size and product features.
13.1 Attach the corrugated hose with the end adapter to the high-flow deflator outlet which is located on the right side of the 1150.
13.2 The main accessory adapter attached to the corrugated hose accommo- dates up to 4 sizes. If another size is needed, an additional adapter can be attached to the end of the main accessory adapter.
13.3 Insert the adapter into the item to be deflated.
13.4 Push the inflator switch to the ON position and deflate item.
13.5 When product is deflated to the desired level, push the inflator switch to the OFF position and remove the adapter.
,8,
Page 11
14.1
14.2
14.3
14.4
14.5
14.6
14.7
14.8
14.9
Important Safety Instructions: Keep the 1150 well ventilated in order to properly disperse heat generated
while it is in use. Make sure there are several inches of clearance around the top and sides and do not block the vents on the back of the 1150.
Make sure the 1150 is not close to any potential source of flammable
fumes, gases or clothing.
Keep the 1150 dry. DO NOT allow the 1150 to come into contact with rain or moisture.
DO NOT operate the 1150 if you, the 1150, the device being operated or any other surfaces that may come in contact with any power source are wet. Water and many other liquids can conduct electricity, which may lead to serious injury.
Do not place the 1150 on or near heating vents, radiators or other sources of heat.
Do not place the 1150 indirect sunlight. The ideal air temperature for operation is between 50° and 80°F.
Do not use inverter near open engine compartment where fumes or gases
may accumulate.
Do not modify the AC receptacles in any way.
It is important to know the continuous wattage of the device you plan to use with the inverter. The Portable Power 1150 must be used with devices
drawing 400 watts or less. If the wattage is not marked on the device, use only devices that draw less than 4 Amps of AC.
Devices like TVs, fans or electric motors require additional power to start (commonly known as the "starting or peak power"). The Portable Power
1150 can supply a momentary surge in wattage; however even devices rated less than the maximum 400 watts can exceed the inverters surge capability and cause an automatic overload shutdown.
Make sure the device you are using is compatible with a modified sine wave inverter.
CAUTION: Always run a test to establish whether the inverter will operate a particular piece of equipment or device,
NOTE: In the event of a power overload, the inverter is designed to auto-
matically shut down. This safety feature prevents damaging the inverter while testing devices and equipment with the 400-watt range.
Note: If powering more than one device, start one device at a time to avoid a power surge and/or inverter overload. The surge toad of each de- vice should not exceed the inverter's Continuous Operation wattage rate.
.9.
Page 12
16.1
16.2
16.3
To operate a 110V AC device: Open the protective cover of the AC power outlet on the front panel of the
Portable Power 1150.
Plug the 110V AC device into the AC power outlet, and place the Inverter/ Compressor Switch in the INVERTER position.
If the device does not operate properly when first connected to the in- verter, push the inverter rocker switch ON (I), OFF (0), and ON (I) again
in quick succession. If this procedure is not successful, it is likely that the
1150 inverter does not have the required capacity to operate the device
intended.
16.4 Charge the Portable Power 1150 as soon as possible after each use. CAUTION: Incorrect operation of your inverter may result in damage and
personal injury. The inverter output is 110V AC and can shock or electro- cute the same as any ordinary household AC walt outlet.
Appliance Type
Spotlights, Sump Pumps, DVD Players Faxes, TVs, Small Power Tools Computer Printer, Medium Power Tools, Blenders
The maximum continuous load is 400 watts.
Estimated Estimated
Power Time*
100 Watts 1.5 Hours 150 Watts 1.25 Hours
200 Watts 55 Minutes
*NOTE: Estimated run-times. Actual time may vary. Times are based on the internal battery being new, fully charged and operated at room tem- perature.
.10.
Page 13
18.1
IMPORTANT:
* CHARGE IMMEDIATELY AFTER PURCHASE * KEEP FULLY CHARGED.
Charge the 1150 internal battery immediately upon purchase, every 30 days and after every use.
All batteries are affected by temperature. The ideal storage temperature is between 40 and 70 degrees Fahrenheit. The internal battery will gradually self-discharge (lose power) over time and more quickly in warm environ-
ments. Leaving the battery in a discharged state may result in permanent battery damage. To ensure satisfactory performance and avoid permanent damage, charge the internal battery every month.
When the JUMP START ON/OFF switch is ON, the clamps are live and will produce arcing or sparking if they come in contact with each other. To prevent accidental arcing, always keep the clamps on the storage holders
and the JUMP START ON/OFF switch in the OFF position when not using
it to jump start a vehicle.
Replacing the built-in light To
1.
2.
3.
4.
replace the built-in light bulb:
Turn the light off.
Insert a standard (flat blade) screwdriver into one of the two slots along
the bottom of the plastic tens and GENTLY pop the tens out. Repeat for the other side.
Gently grasp the bulb and twist counter-clockwise one quarter-turn to unscrew the bulb.
5.
6.
Insert a replacement bulb of the same type and rating, and twist clock-
wise one quarter-turn to screw in the new bulb. Replace the tens cover. Test the light by switching the light on and off.
18.2 Customer Technical Assistance Customer technical assistance is available Monday-Friday, 7 am to 4:30
pm Central Time by phoning 1-800-SEARS-64.
11
Page 14
Internal Battery Type DieHard Maintenance-free AGM Lead-acid Nominal Voltage 12v DC Capacity 22 Ah DC Power Outlet (Max. Continuous Load) 15A per outlet Built-in Light Bulb (Replaceable) 5w/12v DC (Base type BA9S)
Jumper Cables 4-gauge AWG, 24 Inches
Dimensions (H xW x D) 12 H x 11.5 x 10.5 Inches Product Weight 24.5 Ibs.
Maximum Continuous Power 400 Watts Surge Capacity (Peak Power) 800 Watts
No Load Current Draw <0.4 Amps
Wave Form Modified Sine Wave
Input Voltage Range 10.5 - 15.5V DC
AC Outlets Two, 110V AC 3-Prong Grounded
Parts and customer technical assistance are available Monday-Friday, 7
am to 4:30 pm Central Time at 1-800-SEARS-64.
Air Compressor Accessory Kit: (3 Hose Adaptors) 00-99-000599
Inflator Accessory Kit: (Inflator / Deflator Hose, Unit End
and 3 Hose Adaptors) 00-99-000598
Male-to-Male Accessory Cable: 38-99-000834 Replacement Light Bulb: 00-00-000722
Lens Cover: 37-99-00382-0
Wall Charger: 93026681
Replacement Battery Kit: 2299001766
.12.
Page 15
,13,
Loading...