Dickson Industrial SC3 User Manual

Page 1
DICKSON
SC3
Temperature Chart Recorder Operation
Contents:
Product Applications and Useful Features Product Specications Charts & Accessories Calibrations Operating Instructions / Getting Started Troubleshooting Warranty / Factory Service & Returns
DICKSON
Useful Features
Applications &
Product
Specications
Product
Accessories
Charts &
Calibrations Operating
Rev. 06/03
Getting Started
Instructions /
Troubleshooting Warranty/
Factory Service
& Returns
Page 2
Rev. 06/03
Product Applications
The SC3 sets a new standard for compact recorders while providing the accuracy and resolution required for regulatory compliance and quality control. The reusable SC3 is rugged enough to withstand the rigors of transportation and storage applications. Best of all, its unbeatable low price makes temperature recording affordable for virtually any application.
Useful Features
DICKSON
Useful Features
Applications &
Product
• Rugged case ideal for transportation and storage applications
• F/C Switchable, 24 hour/7 day Switchable
• Easy user calibration
• Security slots for recorder security
• Special ranges for refrigerators, freezers, incubators and ambient conditions
• Optional tamper seals can be used to insure the integrity of the chart
• Compact (less than 4” tall /wide) and durable
• Operates for up to 2 years on a single “AA” battery
• Direct sensing, no remote probe, compact enough to be placed almost any where
Specications
Product
Accessories
Charts &
Calibrations Operating
Getting Started
Instructions /
Troubleshooting Warranty/
Rev. 06/03
Factory Service
& Returns
Page 3
Product Specications
DICKSON
Useful Features
Applications &
Product
Temperature Sensor: Precise spiral wound bi-metallic strip transducer Recorder Accurac y: ±4˚F (±2.5˚C) over full scale Ambient Operating Temperature: -22 to +122˚F (-30 to +50˚C) Response Time: 11 minutes to move 63% of full scale in air moving 5’ per second Temperature Ranges: (˚F or ˚C depending on chart installed) -14 to +32˚F (-25 to 0˚C),
+4 to +50˚F (-15 to +10˚C), +22 to +68˚F (-5 to +20˚C), +50 to +96˚F (+10 to +35˚C), +76 to +122˚F (+25 to +50˚C)
Recording Time : 24 hour or 7 day Power Supply: Single “AA” battery, up to 2 years average life Resolution: Not less than 1” per +55˚F in 1˚C or 2˚F steps Mounting: Free standing, wall mounted or suspended Chart Size: 3” (75mm) DIA Dimensions: 3.667” x 3.667” x 2.232” (93mm x 93mm x 57mm) Weight : 0.5 lbs. (227 g) Includes: Battery, pen and instruction manual
Specications
Product
Accessories
Charts &
Calibrations Operating
Getting Started
Instructions /
Troubleshooting Warranty/
Rev. 06/03
Factory Service
& Returns
Page 4
Rev. 06/03
Charts
°F and °C Switchable 7 Day 7 Day 24 Hour 24 Hour Range °F Chart °C Chart °F Chart °C Chart
-14 to +32°F / -20 to 0°C C302 C310 C301 C309 +4 to +50°F / -15 to +20°C C304 C312 C303 C311 +22 to +68°F / -5 to +20°C C320 C318 C319 C317 +50 to +96°F / +10 to +35°C C306 C341 C305 C313 +76 to +122°F / +25 to +50°C C308 C316 C307 C315
DICKSON
Useful Features
Applications &
Product
Accessories
Description Order #
NIST Traceable Calibration 3-pt. (new unit) N300 A2LA Accredited Calibration 3-pt. (new unit) N400 Pens (6 red) P222 Locking Wall Mount Case A715 Waterproof Pouch A711
Specications
Product
Accessories
Charts &
Calibrations Operating
Getting Started
Instructions /
Troubleshooting Warranty/
Rev. 06/03
Factory Service
& Returns
Page 5
Calibration Services - New Units
N100 - NIST Traceable Calibration 1-Point: Includes documentation to one Dickson pre -selected point on new units only.
N300 - NIST Traceable Calibration 3- Point : Includes documentation of three Dickson pre-selected points (a high, medium, and low) on new units only.
N400 - Deluxe A2L A Accredited NIST Traceable Calibration 3-Point: ISO Guide 25/A2LA Docu­mentation of 3 pre- selected points of as found data before and after calibration for Dickson temperature and/or humidity instrumentation on new units only.
N995 - NIST User Selected Temperature Points: Documentation of one customer specied point. Should be selected in addition to one of the above calibration options.
The Importance and Benets of Regular Calibrations
Once you begin to use your precision Dickson instrumentation, regular calibrations are necessary to ensure accurate readings.
The following Calibration Services are available:
N150 - NIST Traceable Calibration 1- Point: Includes documentation to one Dickson pre-selected point after re -calibration.
N350 - NIST Traceable Calibration 3 -Point: Includes documentation of three Dickson pre-selected points (a high, medium, and low) after re-calibration.
N450 - Deluxe A2LA Accredited NIST Traceable Calibration 3-Point: ISO Guide 25/A2LA Docu­mentation of 3 pre- selected points of as found data before and after calibration for Dickson temperature and/or humidity instrumentation.
N995 - NIST User Selected Temperature Points: Documentation of one customer specied point. Should be selected in addition to one of the above calibration options.
DICKSON
Useful Features
Applications &
Product
Specications
Product
Accessories
Charts &
Calibrations Operating
Why should I recalibrate my instrumentation? Over time dirt, dust and normal handling can throw your precision instrumentation out of calibration. Regu­lar calibrations ensure that you receive the most accurate readings possible.
How often should I recalibrate my instrumentation? Depending on the environment your instrument is used in and how often it is handled you will want to recalibrate your instrument every 6 to 12 months. Instruments in environments where there are extreme tem­peratures, wide temperature ranges, humidity or pressure variations, high condensation, dirt, dust and other debris will require calibration at least ever y 6 months. Instruments that are frequently moved or in locations with heavy machinery that cause vibrations should also be calibrated at least every 6 months.
Why should I return my instrument to Dickson for calibration? Dickson calibrates your instrument at the factory using proprietary production/calibration software that guarantees proper calibration.
Our Capabilities Dickson is the rst manufacturer of humidity and temperature instrumentation to receive A2LA accreditation. We are also NIST Traceable; our procedures conform to MIS-STD-45662A, ANSI /NCSL 2540-1-1994, ISO/ IEC Guide 25 and ISO10012. We are experts in the manufacture and calibration of humidity and temperature instruments.
Fast Service: Our turnaround time is 3 days or less so you receive not only expert service but fast service as well.
Easy: We make it easy for you! No phone calls for Return Authorization Numbers are required. We remind you when your instrument is due for calibration. You simply send in the completed Calibration Order Form with your unit for calibration with freight prepaid to Dickson.
Rev. 06/03
Getting Started
Instructions /
Troubleshooting Warranty/
Factory Service
& Returns
Page 6
Rev. 06/03
Getting Started
• Place chart on recorder
• Set time by inserting a coin into chart hub and turning clockwise until the current hour is referenced to the time index clip. (Time index clip is directly to the right and below the pen tip).
• Remove protective pen cap. The chart movement is self-starting and runs continuously. Allow unit to stabilize in environment for 15 minutes.
Pen Replacement
Slide the used pen cartridge off and slide the new one on. Typical pen life is one year.
Battery Replacement
The battery compartment is located on the back of the recorder. The recorder uses a standard “AAA” battery for up to two years of battery life.
• Insert new battery with the positive end down
Chart Rotation Speed
DICKSON
Useful Features
Applications &
Product
Specications
Product
Accessories
Charts &
The unit has a switchable clock, you can change the speed from a 7 day to a 24 hour rotation and from a 24 hour to a 7 day rotation. Make sure the right chart is selected for your rotation. Simply move the switch located on the back of the unit to the speed that ts your application.
Calibrations Operating
Getting Started
Instructions /
Troubleshooting Warranty/
Factory Service
& Returns
Rev. 06/03
Page 7
Troubleshooting
Pen Tension
If the pen is not touching the paper, remove red pen and push the metal pen arm down near the middle of the arm. If that does not work unscrew the pen arm from the recorder and bend the pen arm down. Make sure the unit is in a stable environment, replace the pen arm at the same spot from where it was removed.
Chart Does Not Rotate
If the chart is not rotating make sure the center strip of the chart is inserted properly into the black center hub of the recorder making sure the chart is not torn or ripped. If the chart is properly installed and there is still no rotation the clock needs to be replaced, please call customer ser vice for a return authorization number.
DICKSON
Useful Features
Applications &
Product
Specications
Product
Accessories
Charts &
Calibrations Operating
Rev. 06/03
Getting Started
Instructions /
Troubleshooting Warranty/
Factory Service
& Returns
Page 8
Warranty
Dickson warrants that the products it sells will be free from defects in material and workmanship under normal use and service for a period of twelve months after delivery. In the event of a claim under this warranty, the product or part must be returned to the factory for repair or replacement (shipping pre- paid) with a Return Authorization Number (see Return Information above). It will be repaired at Dickson’s option without charge. This warranty DOES NOT cover routine calibration, pen, chart and battery replacement. The foregoing warranty and remedy are exclusive and in lieu of all other warranties either expressed or implied. Dickson shall not be liable for consequential or incidental damages resulting from failure or malfunction of its products. Dickson makes no warranty for products not manufactured by it or for any products modied by buyer, or subject to misuse or neglect.
DICKSON
Useful Features
Applications &
Product
Factory Service & Returns
Contact the factory (630 -543 -3747) for a Return Authorization (RA) Number before returning any instrument. The model number, serial number and a purchase order number will be requested before an RA number is issued.
• Carefully repack the instrument, label the outside of the box with the RA# and return the instrument (freight pre- paid) to Dickson.
• All instruments that do not have the RA# clearly marked on the outside of the box will be refused. When returning instruments for credit, please include all accessories in shipment.
• Calibration/Freight charges are non- refundable.
NOTE: Dickson shall not be liable for consequential or incidental damages resulting from failure or malfunction of its products.
Customer Satisfaction
Dickson takes pride in providing you, the customer, with the highest quality instrumentation. We welcome the opportunity to help you in any way possible. Whether it be a question or a new idea in documentation, the Dickson Company would like to hear your response. Please call our Customer Service Department at 1-800-323-2448 or (630) 543-3747 (in Illinois).
Software Return Policy
IMPORTANT-Read your Software License Agreement carefully before installing software. DIckson will accept returns for replacement of defective disks and CDs only.
Specications
Product
Accessories
Charts &
Calibrations Operating
Getting Started
Instructions /
Troubleshooting Warranty/
Rev. 06/03
Factory Service
& Returns
DICKSON
930 South Westwood Avenue
Addison, Illinois 60101
Phone: ( 630) 543-3747 • E-mail: DicksonCSR@ dicksonweb.com
Loading...