Step 1 Location
Select a location in a cavity beneath a kitchen cupboard ensuring the area is clean and level. Care should be taken not to store perishable goods in the cupboard directly above the heater unit
Supply should be through a 2 pipe pumped central heating system
Step 3 Electrical supply
Warning: This application must be earthed A fused (5amp) electrical spur with a switch should be fitted in an easily accessible
position
.
Note: Electrical installation must comply with local or national regulations
1
Page 3
Step 4 Preparation
This product is normally fitted directly onto the floor.Once the position has been
decided, mark out and cut
the plinth to the dimensions as shown below
.
AB3203
320mm 100 mm
A= Width of cutout B= Height of cutout
• Floor mounting
• Plinth mounting
Step 5 Water Connections
Fit the valve end of the flexible hoses to the Plinth Heater and the other ends to the central heating flow and return pipe work. Note the direction of flow arrows on the valves are not important in this application
System
y
pipe work
Flexible hoses
Isolating Valves
2
Page 4
• Air vent screw
Step 6 System Venting
Fill the System and vent the air from the heat exchanger using the air vent screw. Close the vent screw ensuring that there are no leaks.
Step 7 Fitting
Ensuring that the flexible hoses do not kink and the electrical cable is not in contact with any
hot surfaces slide the plinth heater under the cupboard until the front edge is just behind the line of the plinth. Replace the plinth and pull the heater through the opening till the front edge projects 8mm through the plinth.
8mm
3
Page 5
Step 8 Fitting the Grill
Screw the Grill to the front of the Plinth Heater using the 2 shorter screws at point “A” Secure the grill to the plinth using the longest screws at point “B”
A
B
Operation
Switch the unit on at the socket. Set the heating switch to the red disc position. Select the fan speed to Low or Boost. The fan will start to rotate provided hot water is circulating through the heat exchanger at or above 43degrees C. If the central heating system has just been switched on there may be a delay in the fan starting till the system reaches 43degrees C. When the central heating system switches off and the system temperature drops below 43degrees C the fan will stop automatically. During the summer the plinth heater can be used for air circulation without heat. Set the heating switch to the Blue disc position. In this position the fan will run until the unit is manually reset.
“0” Winter switch “1” Summer switch
“I” Low
4
0” Of
f
“II” Boost
Page 6
Maintenance
Before any maintenance is carried out on the unit the electrical supply must be isolated. Maintenance should be restricted to dust and lint removal around the unit.
Do not tamper with any electrical parts
A installer should be used for other maintenance requirements.
Technical Data
Test Pressure: 20 bar Maximum working pressure:10 bar Electrical supply: 220-240 V – 50 Hz. Water connections: 15mm compression