Contents

Contents ............................................................................................................................................... 2
Figures .................................................................................................................................................. 3
Terms and Definitions ......................................................................................................................... 4
References ........................................................................................................................................... 4
1 Introduction.................................................................................................................................... 5
1.1 Certification Mode ................................................................................................................. 5
1.2 Network Mode ....................................................................................................................... 5
1.3 OTP Mode ............................................................................................................................. 6
2 How to Connect ............................................................................................................................. 6
2.1 USB to Serial Driver .............................................................................................................. 6
3 DA16200 SDK or Firmware Selection .......................................................................................... 6
4 How to Run GUI with DA16200 EVK ............................................................................................ 7
4.1 Connection and Running....................................................................................................... 7
4.2 COM Port and Baud Rate Configuration............................................................................... 9
4.3 RF Certification Mode ......................................................................................................... 10
4.4 TX Test Mode ...................................................................................................................... 11
4.5 RX Test Mode ..................................................................................................................... 13
5 Network Mode .............................................................................................................................. 14
5.1 Station Mode ....................................................................................................................... 15
5.2 AP Mode ............................................................................................................................. 17
5.3 Data Transfer (TCP/UDP) ................................................................................................... 19
5.3.1 TCP Server .......................................................................................................... 19
5.3.2 TCP Client ........................................................................................................... 20
5.3.3 UDP Session ....................................................................................................... 21
5.3.4 Data Exchange .................................................................................................... 21
5.3.5 Data Transfer on DPM Mode ............................................................................... 22
5.4 MQTT Client ........................................................................................................................ 24
5.4.1 Configuration ....................................................................................................... 24
5.4.2 Data Exchange .................................................................................................... 25
5.4.3 MQTT on DPM Mode ........................................................................................... 25
5.5 TLS Setting ......................................................................................................................... 26
6 OTP Mode Setup .......................................................................................................................... 27
Revision History ................................................................................................................................ 28
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
3 of 29
© 2021 Dialog Semiconductor

Figures

Figure 1: DA16200 EVK GUI ................................................................................................................. 5
Figure 2: Development Kit Connections ................................................................................................ 7
Figure 3: AT GUI ................................................................................................................................... 8
Figure 4: RS232 Setup - Disconnected ................................................................................................. 9
Figure 5: RS232 Setup - Connected ..................................................................................................... 9
Figure 6: Debug Console - Connected .................................................................................................. 9
Figure 7: Certification Mode Configuration .......................................................................................... 10
Figure 8: Tx Test Mode Configuration ................................................................................................. 11
Figure 9: Debug Console - TX Mode ................................................................................................... 11
Figure 10: Start and Stop TX ............................................................................................................... 12
Figure 11: Debug Console - Start TX .................................................................................................. 12
Figure 12: Debug Console - Stop TX .................................................................................................. 12
Figure 13: Rx Configuration................................................................................................................. 13
Figure 14: Network Mode Configuration .............................................................................................. 14
Figure 15: Setup Window - Station Mode ............................................................................................ 15
Figure 16: Station Mode - SCAN ......................................................................................................... 15
Figure 17: Station Mode - Choose AP and Connect ........................................................................... 16
Figure 18: Debug Console - Connect to AP ....................................................................................... 16
Figure 19: Setup Window - AP Mode .................................................................................................. 17
Figure 20: AP Configuration ................................................................................................................ 18
Figure 21: Debug Console - AP Configuration ................................................................................... 18
Figure 22: DHCP Configuration .......................................................................................................... 18
Figure 23: Debug Console - DHCP Configuration .............................................................................. 19
Figure 24: Data Transfer Tab .............................................................................................................. 19
Figure 25: TCP Server Open ............................................................................................................... 19
Figure 26: TCP Server Connection with a Client ................................................................................ 20
Figure 27: TCP Client Connection to a Server .................................................................................... 20
Figure 28: UDP Session Open ............................................................................................................ 21
Figure 29: TCP Server Data Transfer ................................................................................................. 21
Figure 30: TCP Client Data Transfer ................................................................................................... 22
Figure 31: UDP Session Data Transfer ............................................................................................... 22
Figure 32: TCP/UDP Data Reception .................................................................................................. 22
Figure 33: DPM Mode Setting ............................................................................................................. 22
Figure 34: MQTT Client Tab ................................................................................................................ 24
Figure 35: MQTT PUBLISH Transfer .................................................................................................. 25
Figure 36: MQTT PUBLISH Reception ............................................................................................... 25
Figure 37: TLS Setting Tab ................................................................................................................. 26
Figure 38: OTP Mode .......................................................................................................................... 27
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
4 of 29
© 2021 Dialog Semiconductor

Terms and Definitions

AP Access Point AT AT Command Interpreter Software Subsystem, or Attention CoAP Constrained Application Protocol DHCP Dynamic Host Configuration Protocol EVK Evaluation Kit GUI Graphical User Interface HTTP Hyper Text Transfer Protocol MFC Microsoft Foundation Class MQTT Message Queuing Telemetry Transport OTP One Time Programmable PC Personal Computer QFN Quad Flat No-lead SDK Software Development Kit SSID Service Set IDentifier STA STAtion TCP Transmission Control Protocol TLS Transport Layer Security UART Universal Asynchronous Receiver Transmitter UDP User Datagram Protocol USB Universal Serial Bus

References

[1] DA16200, Datasheet, Dialog Semiconductor [2] DA16200, SDK Programmer Guide, User Manual, Dialog Semiconductor [3] DA16200, EVK User Guide, Dialog Semiconductor [4] DA16200, AT Command User Guide, Dialog Semiconductor
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
5 of 29
© 2021 Dialog Semiconductor

1 Introduction

The DA16200 GUI tool lets users control the DA16200 EVK in a GUI environment. There are three modes of operation: Certification mode, Network mode and OTP mode (see Figure 1).
Figure 1: DA16200 EVK GUI

1.1 Certification Mode

This mode is for Wi-Fi RF test (Tx power, Rx sensitivity, etc.) also known as “TEST Mode”.

1.2 Network Mode

With Network mode, the Station or AP mode of the DA16200 is tested.
AP mode: Soft-AP test with configurable parameters like SSID, security, DHCP Server, etc.
Station mode: STA test to search and connect to an Access Point and check/test the STA
function
After the network mode is set, the user can test the TCP/UDP or the MQTT and manage the TLS certificates.
Data Transfer: message exchange through the TCP Server/Client, and UDP session
MQTT Client: message exchange through the MQTT protocol
TLS Setting: management of TLS certificate that is set (e.g. Root CA, Client Certificate, Client
Private Key)
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
6 of 29
© 2021 Dialog Semiconductor

1.3 OTP Mode

This mode is for power calibration and temperature calibration with OTP memory location.

2 How to Connect

2.1 USB to Serial Driver

The DA16200 evaluation board supports USB to serial interface. The user connects to DA16200 EVK with the PC through a micro-USB cable and then two COM ports will be detected automatically.
One (UART0) is for console command and the other (UART1) is for AT command. Normally, the higher number COM port is for AT commands and the lower number COM port is for the console.
Required the FT232 Driver installation for Windows In most cases, it will be installed automatically
The FTDI driver for the FT2232 FTDI chip used on DA16200 EVK is available for download at the following link: http://www.ftdichip.com/Drivers/CDM/CDM21224_Setup.zip
See the EVK User Guide [3] to find information about the UART1 port. AT GUI tool uses UART1
port.
To update with a new DA16200 firmware, see the DA16200 EVK User Guide [3].

3 DA16200 SDK or Firmware Selection

There are a number of types of SDK and firmware for DA16200 such as Generic and Manufacture that can be found in DA16200 SDK/Image packages. Consider the kinds of tests you plan to determine which SDK or firmware should be picked up.
Certification or OTP Mode: SDK: DA16200_SDK_Manufacture_QFN_xxx.zip Firmware: DA16200_IMG_Manufacture_QFN
Network Mode: SDK: DA16200_SDK_Generic_QFN xxx.zip
The __SUPPORT_ATCMD__ where can be found in config_generic_sdk.h file should be
enabled.
[\src\customer\config_generic_sdk.h]
// AT-CMD features
#define __SUPPORT_ATCMD__ // Support AT-CMD
Firmware: ATCMD firmware should be picked such as
DA16200_IMG_Generic_QFN_ATCMD, DA16200_IMG_Generic_FcCSP_LP_ATCMD or DA16200_IMG_Generic_FcCSP_NP_ATCMD depending on SoC package type.
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
7 of 29
© 2021 Dialog Semiconductor

4 How to Run GUI with DA16200 EVK

4.1 Connection and Running

DA16200 AT GUI program is a single executable file.
NOTE
If there is an error with the message “a DLL file (e.g. vcruntime140.dll or mfc1400u.dll) is missing”, then install
Microsoft Visual Studio redistributable package (https://www.microsoft.com/en­us/download/details.aspx?id=48145) or copy the .dll file into the Windows system folder (C:\Windows\System32 or C:\Windows\SysWOW64).
The program setup sequence is:
1. Connect the DA16200 Development Kit to the host PC as shown in
2.
3. Figure 2.
Figure 2: Development Kit Connections
NOTE
See the EVK User Guide [3] to know which port to use.
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
8 of 29
© 2021 Dialog Semiconductor
4. Start the AT GUI program.
Figure 3: AT GUI
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
9 of 29
© 2021 Dialog Semiconductor

4.2 COM Port and Baud Rate Configuration

1. When the AT GUI program runs, the connection status is red (not connected). If the program does not detect any COM port, click the Refresh button to refresh the COM Port. See Figure 4.
Figure 4: RS232 Setup - Disconnected
2. Select a COM port and click the OPEN button and wait for a few seconds. See Figure 5 and
Figure 6.
The connection status will soon change to a green color and the Connection Status field
shows “Connected” in a green color. This means that communication is OK.
Figure 5: RS232 Setup - Connected
In the Debug Console window (in the black box), the message “Echo on” is shown.
Figure 6: Debug Console - Connected
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
10 of 29
© 2021 Dialog Semiconductor

4.3 RF Certification Mode

To enable certification mode:
1. Open the Settings tab. See Figure 7.
2. In the RF Mode area, select the Certification Mode check box.
Figure 7: Certification Mode Configuration
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
11 of 29
© 2021 Dialog Semiconductor

4.4 TX Test Mode

1. Open the Certification Mode tab. See Figure 8.
Figure 8: Tx Test Mode Configuration
2. Click the Mode Select button (Figure 8). A confirmation message is shown as in Figure 9. This is a normal state.
Figure 9: Debug Console - TX Mode
3. Select the Data Rate, Channel, and Power for the purpose of the test.
Packet mode: this is the normal test mode with packet generation mode. Offers the
possibility to adjust duty of RF Burst at time domain
Cont mode: Continuous TX out mode. This mode is for TX power test etc. In this mode, TX
packet is generated continuously over 95% duty cycle
CW mode: Only single sinewave tone out mode. This mode is for freq err check Data Rate: Choose modulation type to test Power: Select or tune the power level. (“0” step is Maximum). The difference between power
steps is about 0.8~1 dB/1step
Size: You can adjust the duty rate with this number. However, the size is not linear as the
number, so to set the exact number you need equipment like a spectrum analyzer to check the value. (Equipment setting is set to zero span setting or burst mode setting)
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
12 of 29
© 2021 Dialog Semiconductor
To do TX packet generation:
To start and stop TX packet generation, use the Start TX button and the Stop TX button. If you
want to make changes for another condition, click Stop TX before a new test is started.
Start TX
Stop TX
Figure 10: Start and Stop TX
For example: there is a test setting with 802.11n MCS7, channel 1, 100 bytes packet and power grade 0.
When the Start TX button is clicked, messages as shown in Figure 11 will be shown.
Figure 11: Debug Console - Start TX
When you click the Stop TX button, messages as shown in Figure 12 will be shown.
Figure 12: Debug Console - Stop TX
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
13 of 29
© 2021 Dialog Semiconductor

4.5 RX Test Mode

The settings are made in the RX Setting area. See Figure 13.
Channel: Support CH1 ~ CH13
Test Time: Maximum 3600 s (Duration is 1 second fixed)
Figure 13: Rx Configuration
RX Packet Rate FCS + PHY + Overflow packet / Total packet = Error rate
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
14 of 29
© 2021 Dialog Semiconductor

5 Network Mode

To enable network mode:
1. Open the Settings tab.
2. Select the Network Mode checkbox. See Figure 14.
Figure 14: Network Mode Configuration
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
15 of 29
© 2021 Dialog Semiconductor

5.1 Station Mode

1. In the Mode Select: field, select Station Mode. See Error! Reference source not found..
The network mode is changed. Next, DA16200 reboots and the station mode setup window
opens. See Figure 15.
Figure 15: Setup Window - Station Mode
2. Click the Scan button to scan APs. See Figure 16.
Figure 16: Station Mode - SCAN
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
16 of 29
© 2021 Dialog Semiconductor
3. When scanning is finished, choose one AP in the list. See Figure 17.
4. Click the Connect button.
5. If required by the security mode of the AP, fill in a password or key index.
Figure 17: Station Mode - Choose AP and Connect
Figure 18: Debug Console - Connect to AP
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
17 of 29
© 2021 Dialog Semiconductor

5.2 AP Mode

1. In the Mode Select field, select AP Mode. See Error! Reference source not found..
The network mode changes, DA16200 reboots and the AP Mode setup window opens. See
Figure 19.
Figure 19: Setup Window - AP Mode
2. Set the fields SSID, Password, Country, Channel, and Security mode. See Figure 20.
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
18 of 29
© 2021 Dialog Semiconductor
3. Click the Confirm button.
Figure 20: AP Configuration
The Debug Console window messages appears as shown in Figure 21.
Figure 21: Debug Console - AP Configuration
4. In the DHCP Server area, make the required settings for the IP addresses and click the Confirm button. See Figure 22.
When a client is connected, the MAC address will be shown as in Figure 23.
Figure 22: DHCP Configuration
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
19 of 29
© 2021 Dialog Semiconductor
Figure 23: Debug Console - DHCP Configuration

5.3 Data Transfer (TCP/UDP)

The DA16200 GUI tool provides data transfer functions with TCP/UDP. Before messages are sent with this tool, connect the DA16200 to an access point as shown in Section 5.1. Then click the Data Transfer tab. If DA16200 succeeds to connect to an AP, the IP address will be filled in. See Figure 24.
Figure 24: Data Transfer Tab
The DA16200 provides three kinds of sessions: TCP server, TCP client, and UDP session. The user can use these three simultaneously.

5.3.1 TCP Server

To use TCP server, fill in a port number and click the Connect button on the TCP Server line. When a server is opened, the X will change to O. See Figure 25.
Figure 25: TCP Server Open
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
20 of 29
© 2021 Dialog Semiconductor
The user can connect to the DA16200 TCP server with tools for data exchange like the IO Ninja. When a client connects successfully, its information will be shown as in Figure 26. The DA16200 TCP server can accept up to eight client sessions.
Figure 26: TCP Server Connection with a Client

5.3.2 TCP Client

To connect to a TCP server, fill in the IP address and port number of the server and click the Connect button on the TCP Client line. When the DA16200 TCP client succeeds to connect, the X will change to O. See Figure 27.
Figure 27: TCP Client Connection to a Server
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
21 of 29
© 2021 Dialog Semiconductor

5.3.3 UDP Session

To open a UDP session, fill in a port number and click the Start button. When the DA16200 TCP client succeeds to connect, the X will change to O. See Figure 28. TODO:
Figure 28: UDP Session Open

5.3.4 Data Exchange

To send a message to a peer, first select a session. Each session is slightly different in method.
TCP Server: Select the TCP Server checkbox Select the destination IP in the drop-down list
Type a message Click the Send button (see Figure 29)
Figure 29: TCP Server Data Transfer
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
22 of 29
© 2021 Dialog Semiconductor
TCP Client: Select the TCP Client checkbox Type a message Click the Send button (see
Figure 30)
Figure 30: TCP Client Data Transfer
UDP Session: Select the UDP Session checkbox Enter the destination IP and port number
Type a message Click the Send button (see Figure 31)
Figure 31: UDP Session Data Transfer
When a session receives a message from a peer, the message is shown in the message window. See Figure 32.
Figure 32: TCP/UDP Data Reception

5.3.5 Data Transfer on DPM Mode

The DA16200 GUI provides TCP/UDP sockets operation in DPM (DA16200 power-save) mode. See
Figure 33.
Figure 33: DPM Mode Setting
DPM Button: DPM mode Start / End
DPM_STATUS: DPM state (Disabled / DPM init… / DPM Sleep / DPM wake-up)
Sleep Button: DA16200 returns to DPM sleep state (only available DPM wake-up state)
To initiate TCP/UDP sockets in DPM mode:
1. Open sockets user wants to.
2. Click the DPM button to start DPM mode.
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
23 of 29
© 2021 Dialog Semiconductor
3. After all sockets are ready in DPM mode, the DPM_STATUS will change to "DPM sleep".
When DA16200 in DPM sleep state receives a TCP or UDP messages from a peer, it is shown in the message window like in Figure 32.
To send a message in DPM Sleep status:
1. Wake up DA16200 with the switch. The DPM_STATUS will change to "DPM wake-up".
2. Select the session to send, type a message, and click the Send button.
3. After sending messages, click the Sleep button. The DPM_STATUS will change to "DPM sleep".
To exit DPM mode:
1. Wake up DA16200 with the switch. The DPM_STATUS will change to "DPM Wake-up".
2. Click the Sleep button. The DPM_STATUS will change to "Disabled".
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
24 of 29
© 2021 Dialog Semiconductor

5.4 MQTT Client

The DA16200 GUI tool provides data transfer functions with MQTT protocol. Before messages are sent with this tool, connect the DA16200 to an access point as shown in Section 5.1. Click the MQTT
Client tab.

5.4.1 Configuration

Before a connection is made to an MQTT broker, set the required fields for the connection information. See Figure 34.
Figure 34: MQTT Client Tab
Broker IP address Broker port number Subscriber topics (up to 4) Publisher topic Sending PINGREQ cycle (second) Login ID
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
25 of 29
© 2021 Dialog Semiconductor
Login password MQTT QoS (0~2) TLS use (0 or 1) Reset all configuration to default
When the DA16200 MQTT client succeeds to connect, the letter X will change to O. Moreover, the user can send a PUBLISH message to the broker or receive a message.

5.4.2 Data Exchange

To exchange a message with the broker, connect the MQTT Client. To send a PUBLISH, type the message and click the PUBLISH button. See Figure 35.
Figure 35: MQTT PUBLISH Transfer
When the client receives a message from the broker, the message is displayed in the message window. See Figure 36.
Figure 36: MQTT PUBLISH Reception

5.4.3 MQTT on DPM Mode

The DA16200 GUI provides MQTT client operation in DPM mode. There is the DPM mode setting as shown in Figure 33 in MQTT Client tab.
To initiate MQTT client in DPM mode:
1. After setting up, connect to a MQTT Broker.
2. Click the DPM button to start DPM mode.
3. After the MQTT client session is ready in DPM mode, the DPM_STATUS will change to "DPM sleep".
When DA16200 in DPM sleep state receives a PUBLISH from the broker, it is shown in the message window like Figure 36.
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
26 of 29
© 2021 Dialog Semiconductor
To send a message in DPM Sleep status:
1. Wake up DA16200 with the switch. The DPM_STATUS will change to "DPM wake-up".
2. Type a message and click the PUBLISH button.
3. After sending messages, click the Sleep button. The DPM_STATUS will change to "DPM sleep".
And to exit DPM mode:
1. Wake up DA16200 with the switch. The DPM_STATUS will change to "DPM Wake-up".
2. Click the Sleep button. The DPM_STATUS will change to "Disabled".

5.5 TLS Setting

The user can store a TLS certificate that is set with this tool for MQTT, HTTPs, CoAPs, and so on. There are three kinds of items: Root CA, Client Certificate, and Private Key.
DA16200 can only process Privacy Enhanced Mail type(.pem). To enter the certificates directly, input the text and click the Upload button with the TLS item selection. If this is done successfully, <Content exists> will appear in the window. See Figure 37.
If the user has TLS certificate files with PEM type, click File Search and select the file. The text will be loaded in the window.
Figure 37: TLS Setting Tab
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
27 of 29
© 2021 Dialog Semiconductor

6 OTP Mode Setup

To enable OTP mode:
1. Open the OTP Mode tab.
2. Click the OPT Enable checkbox
The current OTP data is as shown in Figure 38.
Figure 38: OTP Mode
Power calibration and temperature calibration has been completed for the chipset by Dialog and it
may not need to be done by the customer.
Freq Offset cal: the range of frequency offset calibration is 0x0 ~ 0x7F. MAC Address setup
DA16200 has 4 slots to store MAC addresses. The 1st slot is written by Dialog. The user can use 3 slots to write their own MAC address. The MAC address written in the OTP must be an even number. it is used for WLAN0 MAC address (for STA interface), and the next number is automatically used for WLAN1 MAC address (for Soft-AP interface).
To write the MAC address, give a MAC address in the first empty slot and click the Write button, then the new address substitutes for the previous address.
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
28 of 29
© 2021 Dialog Semiconductor

Revision History

Revision
Date
Description
1.5
06-Jan-2021
Revised as the user interface changes of the tool.
1.4
21-Aug-2020
4.3.5 Data Transfer on DPM Mode Modification
4.4.3 MQTT on DPM Mode Modification Figure 36: MQTT Client Tab Change Figure 45: Solution Explorer Tab
1.3
06-Apr-2020
TCP/UDP, MQTT, and TLS added, GUI Build added
1.2
31-Oct-2019
Finalized for publication
1.1
15-Oct-2019
Editorial review
1.0
03-Jul-2019
Preliminary DRAFT Release
UM-WI-004
DA16200 AT GUI Tool
Revision 1.5
06-Jan-2021
29 of 29
© 2021 Dialog Semiconductor
Status Definitions
Status
Definition
DRAFT
The content of this document is under review and subject to formal approval, which may result in modifications or additions.
APPROVED or unmarked
The content of this document has been approved for publication.
Disclaimer
Unless otherwise agreed in writing, the Dialog Semiconductor products (and any associated software) referred to in this document are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or malfunction of a Dialog Semiconductor product (or associated software) can reasonably be expected to result in personal injury, death or severe property or environmental damage. Dialog Semiconductor and its suppliers accept no liability for inclusion and/or use of Dialog Semiconductor products (and any associated software) in such equipment or applications and therefore such inclusion and/or use is at the customer’s own risk.
Information in this document is believed to be accurate and reliable. However, Dialog Semiconductor does not give any representations or warranties, express or implied, as to the accuracy or completeness of such information. Dialog Semiconductor furthermore takes no responsibility whatsoever for the content in this document if provided by any information source outside of Dialog Semiconductor.
Dialog Semiconductor reserves the right to change without notice the information published in this document, including, without limitation, the specification and the design of the related semiconductor products, software and applications. Notwithstanding the foregoing, for any automotive grade version of the device, Dialog Semiconductor reserves the right to change the information published in this document, including, without limitation, the specification and the design of the related semiconductor products, software and applications, in accordance with its standard automotive change notification process.
Applications, software, and semiconductor products described in this document are for illustrative purposes only. Dialog Semiconductor makes no representation or warranty that such applications, software and semiconductor products will be suitable for the specified use without further testing or modification. Unless otherwise agreed in writing, such testing or modification is the sole responsibility of the customer and Dialog Semiconductor excludes all liability in this respect.
Nothing in this document may be construed as a license for customer to use the Dialog Semiconductor products, software and applications referred to in this document. Such license must be separately sought by customer with Dialog Semiconductor.
All use of Dialog Semiconductor products, software and applications referred to in this document is subject to Dialog Semiconductor’s Standard
Terms and Conditions of Sale, available on the company website (www.dialog-semiconductor.com) unless otherwise stated.
Dialog, Dialog Semiconductor and the Dialog logo are trademarks of Dialog Semiconductor Plc or its subsidiaries. All other product or service names and marks are the property of their respective owners.
© 2021 Dialog Semiconductor. All rights reserved
Contacting Dialog Semiconductor
United Kingdom (Headquarters)
Dialog Semiconductor (UK) LTD
Phone: +44 1793 757700
Germany
Dialog Semiconductor GmbH
Phone: +49 7021 805-0
The Netherlands
Dialog Semiconductor B.V.
Phone: +31 73 640 8822
North America
Dialog Semiconductor Inc.
Phone: +1 408 845 8500
Japan
Dialog Semiconductor K. K.
Phone: +81 3 5769 5100
Taiwan
Dialog Semiconductor Taiwan
Phone: +886 281 786 222
Hong Kong
Dialog Semiconductor Hong Kong
Phone: +852 2607 4271
Korea
Dialog Semiconductor Korea
Phone: +82 2 3469 8200
China (Shenzhen)
Dialog Semiconductor China
Phone: +86 755 2981 3669
China (Shanghai)
Dialog Semiconductor China
Phone: +86 21 5424 9058
Email:
enquiry@diasemi.com
Web site:
www.dialog-semiconductor.com
Loading...