DGFLOW PRESFLO User Manual

10183307A_rev.02
0 50 100 150 200 l/min
0 5 10 15
m H
2
O
PRESFLO
B
50066/115 ~230 / 50 - 60 16 A
1.5 Bar
SN 15060002
B
50066/115 ~230 / 50 - 60 16 A
1.5 Bar
SN 15060002
RUEN FR DEIT ES
ELECTRONIC PUMP CONTROLLER
PRESFLO
®
is a device that starts and stops the pump to which it is tted, thus replacing traditional pressure switch / surge tank systems. The pump is started when, as a tap is turned on, the pressure within the system drops below the “start-up pressure” (Pm), and is stopped when the ow
USER’S MANUAL
rate required is zero or less than the “shut-off ow rate” (Qa). PRESFLO
®
’s electronics protect the pump against unsuitable operating conditions such as dry running or repeated start­ups due to leaks.
Technical specications
Operating conditions
A. Compatible/non compa­tible uids
PRESFLO
®
is suitable for use with clean water and chemical­ly non-aggressive liquids. If the uid contains impurities, a lter should be tted upstream.
B. Environmental conditions
PRESFLO
®
should not be used where there is the risk of an explosion. The temperature of the location should range between 0°C and 40°C, and the humidity should not exceed 90%.
C. Power supply
Make sure that the variation
in the power supply is never more or less than 10 % of the RATING value. Higher values may cause
damage to the electronic components. PRESFLO
®
can only be used
with single-phase pumps.
Working area
Flow rate
Pressure
Shut-off ow rate
Start-up pressure
2 l/min (0,5 gpm)
Red =
Blue =
Yellow =
Qa
Pm
Safety regulations
Before installing or using PRESFLO
®
, read this manual carefully and thoroughly. The pump should be installed and serviced by qualied per­sonnel, responsible for making the hydraulic and electrical connections in compliance with the relevant regulations. DGFLOW
®
shall not be held lia­ble for any damage relating to, or resulting from, an improper use of the product, or for any damage relating to, or resulting from, servicing or repairs carri­ed out by unqualied personnel and/or with non-OEM spare parts. The warranty, which is valid for 24 months from the date of purchase, will no longer be applicable should the product suffer damage as a conse­quence of the use of non-OEM spare parts, tampering or improper use. When starting the installation, check the following:
- the power supply is switched off.
- the power lines can withstand the maximum current.
- the cable bushings and circuit board cover have been properly assembled and secured ( see Electrical Connections ).
- Power supply network must be tted with proper protection device (fuse or magneto­thermal relay) upstream of PRESFLO
®
When servicing the product, check the following:
- the system is not pressurised (turn a tap on)
- the power supply is switched off.
Emergency Stop
When in use, the pump can be stopped in the event of an emergency: press STOP/RESTART.
PRESFLO
®
is put STAND-BY.
Never disassemble
water accumulator
Water accumulator
Losses
- Voltage: ~230 Volt / ~115 Volt
- Frequency: 50-60 Hz
- Current: 10A, max 12A for 3 sec.
- Current: 12A, max 16A for 3 sec.
- Protection grade: IP 65
-
Start-up pressure (Pm):
0,8/1,5/2,2 bar
(12/22/32 psi)
- Shut-off ow rate (Qa): 2 litres/min (0,5 gpm)
- Connections: 1” BSP / 1” NPT
- Maximum working pressure: 10 bar (145 psi)
- Bursting pressure: 40 bar (580 psi)
- Weight: 650 g
- Protection against:
- dry running (automatic restart)
- repeated start-ups
- Max room temperature: 40°C
- Max liquid temperature: 55°C
- Type of drive: 1C
- Max manual operations on push button: 1000
- Max automatic operations on relay: 100000
- Class 3A PTI
- Pollution degree : 2
- Max rated voltage pulse: 2,5 kV
- 230V 12A for EMC test
- Pressure operating differential: 10 bar
Before installing, the product, check that the RATINGS correspond with those required.
2,2 bar (32 psi) 1,5 bar (22 psi) 0,8 bar (12 psi)
Preliminary checks
Take the PRESFLO
®
out of the packaging and check the following:
- check for damage,
- check the RATINGS corre­spond with those required,
- that the cable bushings and screws are in place,
- that PRESFLO
®
’s inlets and outlets are clean and free of any packaging materials,
- that the check valve moves smoothly.
Hydraulic connections
the joint in two pieces allows rapid connection to the system. DO NOT apply sealant inside the 2-piece joint because it already has an internal o-ring.
Orientation
PRESFLO
®
can be installed at any angle depending on the ow direction, as indicated in the diagrams.
Position
PRESFLO
®
can either be tted directly to the pump outlet or anywhere along the delivery line. Never install taps between the pump and PRESFLO
®
. Do not install a non-return valve between PRESFLO
®
and the taps, meanwhile it is possible, although not necessary, to in­stall a non-return valve on the suction piping of the pump.
Installation
Red =
Blue =
Yellow =
Attention
The pressure applied by the water column above PRESFLO
®
must not exceed that of the pump start-up pressure (Pm). If, for example, PRESFLO
®
is installed at a height 15 m (50 ft) below that of the highest tap in the sy­stem, the pressure detected by PRESFLO
®
will be approxima­tely 1.5 bar (22 psi). A model with Pm = 2.2 bar (32 psi) should, therefore, be installed in order to guarantee that the pump is started when a tap is turned on.
Attention
The maximum pressure produced by the pump must be at least 1 bar (15 psi) higher than the start-up pressure (Pm). If the pressure produced by the pump is too low, PRESFLO
®
will stop the pump and indicate a ‘dry running’ error message.
First start-up
Priming the pump
For instructions on how to prime (ll) the pump, see the pump manual.
Attention
PRESFLO
®
is tted with a check valve: do not use the PRESFLO
®
’s outlet to ll the pump for priming.
Switching the pump on
The red (Power On) LED lights up; PRESFLO
®
instantly detects that there is no pressure within the system and starts the pump (the green ‘Pump On’ LED lights up). If, within 15 seconds of starting up, PRESFLO
®
does not detect the correct priming of the pump, it stops the pump and indicates a ‘dry running’ error message.
Attention
When the pump is star­ted for the rst time, it
may have to be run for longer in order to complete the priming procedure.
Press the STOP/RESTART button
to restart the pump and complete the priming procedure.
Motor
Line
Nut
Seal
Cable bushing
Attention! The cable bushings and circuit board cover must be properly assembled and secured in order to guarantee IP 65 grade protection of the electrical components.
Electrical con­nections
The electrical connections should be made as indicated in the diagram which can also be found on the inside of the circuit cover.
NOTE 1 - DRY RUN PROTECTION = there is no ow and the pressure is lower than that of the pump start-up pressure (Pm). It occurs when there is no water. After 15 seconds PRESFLO
®
stops the pump and indicates an ERROR message. PRESFLO
®
AUTOMATICALLY tries to resume NORMAL SERVICE at intervals of increasing time (1, 15, 30, 60 minutes and successively once every hour - 24 H for AU/NZ -). If PRESFLO
®
detects any pressure and/or ow, NORMAL SERVICE is resumed, otherwise, the pump is stopped again until the next attempt is made. A MANUAL attempt to resume NORMAL SERVICE can be made at any time.
NOTE 2 - EXCESSIVE STARTS = the repeated stopping and starting of the pump at intervals of less than 1 minute from each other. This occurs when the ow rate is less than 2 litres/min. This may cause damage to the pump. In event of small leaks (dripping),
PRESFLO
®
’s water accumulator guarantees that the pump starts/ stops at time intervals of over 1 minute (less than 60 starts/hour) and that FREQUENT START-UP errors do not occur. In the event of a major leak or extended use at excessively low ow rates (less than 2 litres/min), the pump may be started/stopped as often as once every few seconds, putting the pump at risk of damage. In this case, after about 40 minutes, PRESFLO
®
stops the pump for the following 30 minutes (in order to let it cool down) and indicates an ERROR message. If the time interval between the starts-stops is more than 10 seconds (and therefore poses less of a risk to the pump), PRESFLO
®
will allow the pump to be used for more than 30 minutes. Once that enough time has passed to allow the pump to cool down it is restarted AUTOMATICALLY. The pump may be restarted MANUALLY any time.
20 m (65 ft) 12 m (40 ft) 6 m (20 ft)
1
2a
2c
2b
3
4a
4b
Operation
PRESFLO® is switched off.
Press briey or hold down = nothing happens
Power is restored = PRESFLO
®
resumes NORMAL SERVICE and starts the pump (if necessary).
No power supply
The system is pressurised. All taps are turned off. There is no demand for water. PRESFLO
®
detects an assembly pressure higher than that of the start-up pressure (Pm) and no ow. Press briey = the pump is started manually and runs for a few seconds before stopping again. Hold down = lthe pump is put STAND­BY. For instructions on how to reactivate the pump, see point 3. A tap is turned on = as soon as the pressure falls below the start-up pressure (Pm), the pump is started.
NORMAL SERVICE: the pump is inactive.
The pump has been stopped manually. The pump will remain inactive until a new command is given.
Press briey
= nothing happens.
Hold down
= the pump resumes NORMAL SERVICE. See points 2a - 2b.
The system has just ceased to require water. All taps are closed. The pump is still in operation. The system is pressurized. PRESFLO
®
detects a system pressure higher than the start-up pressure (Pm) and no ow. Press briey or hold down = the pump is stopped and put in STAND-BY To reset see point 3. If the absence of ow lasts for a few seconds the pump is stopped
STAND-BY
NORMAL SERVICE: pump during shutdown
See NOTE 1) PRESFLO
®
has detected that the pump is dry running and has therefore stopped it TEMPORARILY. Press briey = the pump is started and manually and resumes NORMAL SERVICE. See points 2a - 2b.
Hold down
= the pump is put STAND-BY. For instructions on how to reactivate the pump, see point 3.
ERROR: stopped temporarily due to DRY RUNNING
The assembly requires water. One or more taps are turned on. PRESFLO
®
detects a ow; the assembly pressure is normally higher than the START-UP pressure, but it may also be lower. Press briey or hold down = the pump is stopped and put STAND-BY. For instructions on how to reac­tivate the pump, see point 3. The taps are turned off = Sif there is no ow for a few seconds, the pump is stopped.
NORMAL SERVICE: the pump is running
(see NOTE 2) PRESFLO
®
has detected that the pump starting-up too often and has therefore stopped it TEMPORARILY. Press briey = the pump is started and manually and resumes NORMAL SERVICE. See points 2a - 2b.
Hold down
= the pump will not restart and goes OUT OF ORDER. The pump is put STAND-BY. For instructions on how to reactivate the pump, see point 3.
ERROR: temporary shut down due to FREQUENT START UP
= Off = On = Flashing
5
6
3
2
4
1
Made in Italy by
DGFLOW srl Via Emilia, 5 46030 Bigarello (Mantova) Italy tel. +39 0376 340922 fax. +39 0376 249525 info@dgow.it - www.dgow.it
CODE: V / Hz: I max: P start:
B
50066/115 ~230 / 50 - 60 16 A
1.5 Bar
SN 15060002
Exploded view of spare parts
Attention: when ordering spare
parts, always state the position n° from the diagram below and the product code number found in the pressure-ow regulator technical data table. 1 - Circuit board cover 2 - Pressure gauge 3 - Circuit board 4 - Cable bushings 5 - Valve unit 6 - two-pieces joint with OR
Article
Version
Size
Disposal
When disposing of any PRESFLO
®
parts, adhere to the relevant laws and regulations in force in the country in which the equipment is being used. Do not dispose of any polluting parts in the environment.
Statement of Compliance: we declare, under our own respon­sibility, that the product in question is in compliance with the fol­lowing European Directives and national implementation provisions
2014/35/CE Low Voltage Directive 2011/65/CE (RoHS) 2012/19/CE - 2003/108/CEE (WEEE) 2014/30/CE Electromagnetic Compati­bility Directive (EMC) EN 60730-2-6 EN 61000 6-3
Bigarello 01.06.16
DGFLOW S.r.l. President Stefano Concini
Problems Signals Possible causes Solutions PRESFLO
®
will not turn on
No power Check the electrical connections
The pump will not start when a tap is turned on
PRESFLO
®
model with an inadequate start-up pressure (Pm) for the chosen application.
Relocate PRESFLO
®
to another position
Install a model with a higher start-up pressure (Pm)
Faulty electrical connections or pump out of service
Check the electrical connections and that the pump is working
PRESFLO
®
“STAND-BY” Reset PRESFLO® (See Operation, point 3).
PRESFLO
®
in temporary shut down due to “DRY RUNNING” due to lack of water
Wait for the automatic restart or press START to restart manually (See Operation, point 4a)
Maximum pump pressure is insufcient
Replace the pump with one with more suitable characteristics
Install a model with a lower start-up pressure (Pm)
PRESFLO
®
in temporary shut down due to “FREQUENT START-UP”
Wait for the automatic restart or press START to restart manually (See Operation, point 4b). Remove any cause of leakage from system or install an expansion tank
The pump delivers no or low pressure
Filters or pipes may be partly blocked Check the water pipes
PRESFLO
®
’s valve will not open completely
Check that the valve is not blocked by any foreign objects and clean if necessary
The pump stops and starts repeatedly
Leaks within the system (less than the shut-off ow rate Qa)
Check the hydraulic connections and repair any leaks. If a leak cannot be repaired, install an expansion tank
The pump will not stop
The ow rate is higher than the shut-off ow rate (Qa)
Make sure that all taps are turned off and that there are no leaks within the system
PRESFLO
®
’s check valve will not close or is damaged
Check that the valve is not blocked by any foreign objects and clean if necessary