DFE TrueTension TI17C, TrueTension TI18C Instruction Manual

DOVER FLEXO ELECTRONICS, INC.
ISO 9001 CERTIFIED
INSTRUCTION MANUAL
TT
RUE ENSION
TENSION INDICATOR
with Quik-Cal
Model TI17CV in Vertical Mounting Bracket
Model TI18CV-COV in Vertical Mounting Bracket with Cover
Model TI18CH Horizontal Card
5 YEAR WARRANTY
217 Pickering Road
Rochester, NH 03867-4630 U.S.A.
For assistance, please call:
TECHNICAL SERVICE - Installations, Start-Up, Troubleshooting, Repairs, Field
Service, Returns. techsupport@dfe.com
CUSTOMER SERVICE - Replacement Parts, Individual Products, Questions about
Orders, Manuals. customerservice@dfe.com
SALES - Product Information, Systems Application Questions, and
placing orders for standard products and special systems.
sales@dfe.com
Telephone: (603) 332-6150 Fax: (603) 332-3758
E-mail: info@dfe.com Internet: www.dfe.com
©2018 Dover Flexo Electronics, Inc. All rights reserved. Dover Flexo Electronics has made reasonable effort to ensure accuracy of this document. However NO WARRANTY, whether expressed or implied, is given regarding the completeness or correctness of information in this document. Dover Flexo Electronics shall not be liable for damages of any kind arising from the use or misuse of this document. Dover Flexo Electronics reserves the right to make changes, additions, and deletions to this document without notice and without obligation.
NEW!
QUIK-CAL™ PUSHBUTTON ZERO-SET AND CALIBRATION-SET
The new Ti17C and Ti18C tension indicators/transducer interfaces are built with a new labor-saving technology called Quik-Cal! They do not have potentiometers for zero and calibration settings. Instead, they have pushbuttons. Push the button once, for one second, and you are done!
No tension display is needed. No screwdriver is needed. No second-person is needed.
ZERO SET
The weight of the transducer roll produces an output that is not caused by web tension. This is not desirable because it is not a tension measurement. To set the output of the indicator to zero when there is no tension, just press the ZERO button for one second.
You can even eliminate the need to press the ZERO button! The indicator can automatically set the output to zero when power is turned on. Just change a jumper setting on the circuit board.
CAL SET
The weight you select for calibration determines the full-scale tension signal output. The indicator automatically multiplies the weight by the built-in calibration ratio to calculate full output.
The calibration ratio is the ratio of the calibration weight to the tension at full output.
The standard calibration ratio is 1:10, or 10%. So if you hang a 15 lb. weight and push the CAL button, the indicator will produce full output at 150 lbs. tension.
A calibration ratio of 25% is available for low tensions. (This is selected by a jumper on the circuit board). Use of a 15 lb. calibration weight will produce full output at 60 lbs. tension.
STABILITY is another benefit of this technology. The zero and calibration settings are stored digitally, so there is no drift over time and temperature variations as there can be with potentiometers.
Read Section 3.3 for details.
The Ti17C is C marked in its full enclosure version with cover.
The Ti18C is
C marked in all configurations.
The Ti17C and Ti18C are UL/cUL Listed in their full enclosure version
with cover.
-a-
-b-
TABLE OF CONTENTS
SECTION ONE PRODUCT DESCRIPTION
1.1 General Description ........................................ 1
1.2 Exploded View of Ti17C and Ti18C ............................ 1
1.3 Specifications ............................................. 2
1.4 Environmental Conditions .................................... 3
1.5 Standard Features ......................................... 3
1.6 Options .................................................. 4
1.7 Accessories .............................................. 5
SECTION TWO INSTALLATION
2.1 Dimensions............................................... 6
2.2 Selection of Mounting Location ............................... 7
2.3 Safety & EMC Requirements ................................. 7
2.4 Installation Instructions ...................................... 9
2.5 Transducer Voltage Selection ................................ 10
2.6 Tension and Meter Output Selection ........................... 10
2.7 Standard Electrical Connections .............................. 11
2.8 Tension Limit Switch External Relay Connections ................. 12
SECTION THREE CALIBRATION AND SETUP
3.1 Preparation ............................................... 13
3.2 Mechanically Zero the Tension Meter .......................... 13
3.3 Calibrate the Output for Accuracy ............................. 13
3.4 Calibration and Adjustment of Tension Limit Switch ............... 15
SECTION FOUR OPERATING INSTRUCTIONS ............................... 17
SECTION FIVE CARE AND MAINTENANCE ................................. 18
SECTION SIX TROUBLESHOOTING GUIDE ................................ 19
SECTION SEVEN REPLACEMENT PARTS .................................... 20
APPENDICES
APPENDIX: A Location of Jumpers and Adjustments (Figures 17, 18) ............. 21
B Electrical connections (Figures 19, 20) ......................... 22
C Transducer Electrical Connections (Figures 21-24) ............... 24
D Typical Tensions of Various Materials .......................... 28
E Environmental Terms ...................................... 29
Terms and Conditions of Sale and Shipment .................... 30
Declaration of Conformity - Ti17C ............................. 31
Declaration of Conformity - Ti18C ............................. 32
Index .................................................... 33
LIST OF ILLUSTRATIONS
FIGURE PAGE
1 Exploded View of Horizontal Mounting Style ..................... 1
2 Exploded View of Vertical Mounting Style ....................... 2
3 Horizontal Mounting Dimensions .............................. 6
4 Vertical and Open Bracket Mounting Dimensions ................. 6
5 Accessory Tension Meter Dimensions .......................... 7
6 Accessory Tension Meter Enclosure Dimensions ................. 7
7 Cover Stud Hardware ....................................... 8
8 Transducer Voltage Jumpers ................................. 10
9 Tension and Meter Output Jumpers ............................ 10
10 Standard Electrical Connections .............................. 11
11 Tension Limit Switch External Relay Connections ................. 12
12 Ti17C / Ti18C PC Board ..................................... 13
13 Web Path ................................................ 14
14 Tension Limit Switch Board Adjustments .......................15
15 Tension Limit Switch Test Point Values ......................... 16
16 Replacement Part Numbers .................................. 20
17 Ti17C / Ti18C PC Board .................................... 21
18 Optional Tension Limit Switch Board ........................... 21
19 Standard Electrical Connections .............................. 22
20 Optional TLS External Relay Electrical Connections ............... 23
21 Models C, RS, & UPB Transducer Wiring ....................... 24
22 RFA Transducer Wiring ..................................... 25
23 TR & NWI Transducer Wiring ................................. 26
24 LT Transducer Wiring ....................................... 27
SECTION 1
PRODUCT DESCRIPTION
1.1 GENERAL DESCRIPTION
The True Tension™ Ti17C and Ti18C Tension Indicators are designed to provide an isolated interface between any type of DFE tension transducer and a variable speed drive system, computer, tension recorder, or other devices for tension control and display purposes. They also have a separate output to allow the user to connect an analog meter to indicate operating tension. A single terminal block plugs into the circuit card, to which all external connections are made. This plug-in feature allows for easy field installation and servicing.
Models Ti17C and Ti18C are available with three mounting configurations and a choice of 0-10 Vdc or 4­20mA isolated outputs. Quik-Cal standard.
The only difference between the Ti17C and the Ti18C indicators is their power input requirements. The Ti17C operates on 115Vac 60Hz (230Vac 50Hz optional) and the Ti18C operates on 24Vdc, power supplied separately.
pushbutton zero and calibration comes standard. Dual calibration is also
The Ti17C is
configurations.
The Ti17C and Ti8C are UL/cUL LISTED in their full enclosure version with cover.
n
WARNING: The isolated output is designed to prevent ground loops and noise. It is not intended or
approved for safety isolation of hazardous voltages. Do not install unit where the isolated circuit and chassis ground are more than 40Vpk differential.
WARNING: Ti17C models are designed for single phase AC operation only. Do not connect them across
n
three phase lines or to three phase circuits to prevent product damage and potential hazard.
C marked in its full enclosure version with cover. The Ti18C is C marked in all
1.2 EXPLODED VIEWS OF Ti17C and/or Ti18C
Figure 1 - EXPLODED VIEW OF HORIZONTAL MOUNTING STYLE
1
1.2 EXPLODED VIEWS OF Ti17C and/or Ti18C continued...
Figure 2 - EXPLODED VIEW OF VERTICAL MOUNTING STYLE
1.3 SPECIFICATIONS
Power Input: Voltage: .............. Ti17C = 120/230VAC +/- 10%, 50/60Hz, Single Phase
AC operation only for Ti17C.
..............
Typical Current: ..............
.............. 240 VAC, 50/60 Hz = 0.053/0.025 Amp AC
..............
Maximum Current: ..............
..............
Tension Signal Outputs: .............. 0 to +10Vdc OR 4 to 20mA (jumper selectable), both
.............. 0 to +10Vdc capable of over-range, -15% to 120% of full
.............. 0 to +10Vdc max loading is 5mA. This requires a
.............. 4-20mA capable of over-range, -15% to 120% of full
Ti18C = 24 Vdc +/- 10%.
Ti17C = 120 VAC, 50/60 Hz = 0.102/0.047 Amp AC
Ti18C = 0.058Amp DC.
Ti17C = 120/230 VAC = 0.160/0.080 Amp AC
Ti18C = 0.50 Amp DC
isolated from input power and transducer circuit.
scale (-1.5Vdc to 12Vdc), to indicate over-range or error conditions.
2000 Ohm or greater input resistance for equipment connected to this output.
scale (1.6mA to 23mA), to indicate over-range or error conditions.
2
1.3 SPECIFICATIONS continued...
Tension Signal Outputs: continued... .......... 4-20mA max loop resistance is 500 Ohms.
.............. 0 to 1mA meter output with adjustable damping for
optional tension meter.
Output response Time .............. ~ 4 milliseconds (4.13 ms)
Weight: .............. 0.5 lbs (0.23 kg) horizontal, 2.0 lbs (0.91 kg) vertical
Transducer Signal Input: .............. 0.5Vdc at rated load per pair (1.00Vdc for XRE option).
Transducer Excitation: .............. 5Vdc (10Vdc for the XRE option) jumper selectable.
Accuracy: .............. Max error of 1% over temperature range. 0.1% Typical.
Zero (Tare) Range: .............. Minimum 95% of transducer rating.
Calibration Range: .............. Minimum 50 : 1.
Ambient Temperature Range: .............. 32°F to 104°F (0°C to 40°C).
Accessory tension meter types: .............. Analog 1mA, 3.5" (DFE P/N: 722-1385), or meter in
enclosure for CE models (DFE P/N: 723-2682).
Standard tension meter scales: .............. 0 to: 1, 5, 10, 25, 50, 100, 150, 250, 500, 1000.
1.4 ENVIRONMENTAL CONDITIONS (Ref. Appendix E for Environmental Term definitions)
This equipment is safe for use under the following conditions:
Indoor use.
Altitude up to 6500 ft (2000 meters).
Temperature range: 32° F to 104° F (0° C to 40° C).
Maximum relative humidity 95% over the temperature range (non-condensing).
Main supply voltage fluctuations not to exceed +/-10% of the nominal voltage.
Main supply transient overvoltages according to overvoltage category II of IEC 60364-4-443.
Pollution Degree 2 in accordance with EN61010-1:2001.
1.5 STANDARD FEATURES
SOME OF THESE FEATURES REQUIRE CONFIGURATION OR EXTERNAL WIRING. REFER TO SECTION 2.4 FOR INSTALLATION INSTRUCTIONS AND SECTION 2.7 FOR WIRING.
Quik-Cal™ push-button zero and calibration eliminates pot adjustments to make calibrating simple and fast.
0 to +10V Tension Output OR 4 to 20mA Tension Output. Proportional to tension. Used as an input to a
controller or instrumentation system. Both are isolated outputs standard. See Section 3.1 for installation and
adjustment.
WARNING: The isolated output is designed to prevent ground loops and noise. It is not intended or approved
n for safety isolation of hazardous voltages. Do not install unit where isolated circuit and chassis ground are more than 40Vpk differential.
0-1mA Tension Output. A separate output with adjustable damping, used for driving an optional analog
tension meter.
Adjustable Meter Damping. Used to adjust the responsiveness of the optional analog tension meter. Does
not affect the 0-10V/4-20mA output.
Power Voltage Selection. The Ti17C Interface / Indicator is designed to operate at either the standard
115Vac or the optional 230Vac. The Ti18C operates on 24Vdc.
Easily serviceable. The unit can easily be removed after unplugging the mating connector.
Small size. Fits where many other products cannot.
3
1.5 STANDARD FEATURES continued...
Output Isolated from Earth Ground. Isolation is provided between the output circuit and transducer ground,
simplifying installations.
Dual Calibration. Allows two calibration settings. Dual calibration example applications:
a. One set of transducers operating in a wide tension range. Dual calibration and dual meter scale is used to
enhance the resolution of indicated tension.
b. One set of transducers that may be subject to two different wrap angles or web paths. In this case a dual
meter scale may, or may not, be required.
Screw Clamp Mating Terminal Block Connector. Allows easy connection of external wiring.
Status LED. Green LED flashes to verify ZERO and CALIBRATION, and indicates presence of power and
proper circuit operation. If power is on and no faults are detected, LED will be on solid. LED will flash
momentarily to indicate acceptance of a ZERO or CALIBRATION button push.
Short Circuit Protection. Unit automatically protects transducer excitation and tension output from short
circuits or excessive loading. If a short circuit is detected, the unit will safely shut that portion of the circuit
off until the fault is cleared. Unit automatically recovers when the fault is removed.
1.6 OPTIONS
SOME OF THESE OPTIONAL FEATURES REQUIRE CONFIGURATION OR EXTERNAL WIRING. REFER TO SECTION 2.4 FOR INSTALLATION INSTRUCTIONS AND SECTION 2.7 FOR WIRING.
0-100 Microamp Output (100M). 0-100 microamp output to drive tension meter. Jumper selectable.
25% Calibration Weight (25CW). Used when 25% of full scale calibration weight is desired instead of the
standard 10% calibration weight. Jumper selectable to 10% or 25%.
230 Volt Input (230). 230Volt, 50 Hz AC power input. Ti17C only.
n
WARNING: Ti17C models are designed for single phase AC operation only. Do not connect them across
three phase lines or to three phase circuits to prevent product damage and potential hazard.
Auto Zero (AZ). Unit will auto zero the output on each power up. Jumper selected on or off.
Cover (COV). Cover restricts access to board and provides complete enclosure. V version only.
n
WARNING: Ti17C models require the full case and properly installed cover for CE approval. Operating
without a properly installed cover as directed in section 2.3 invalidates CE approval and may pose a shock
hazard.
WARNING: Ti17C and Ti18C models require the full case and properly installed cover for UL/cUL
n
Listing. Operating without a properly installed cover as directed in section 2.3 invalidates UL/cUL Listing
and may pose a shock hazard.
DIN Rail Clip (DRC). To be used with 35 mm DIN rail. V version only.
4 to 20mA Output (I420). Isolated 4-20 mA current output, used in place of isolated 0 to +10V output.
Jumper selected between 0 to +10V and 4-20mA.
Tension Limit Switch (TLS). An open collector output actuates at a pre-set adjustable trip point. Can be used
as a web break detector, or high tension warning. A red LED activates on the front panel when TLS is
triggered. Low and high trip points are independently adjustable. Trigger delay is adjustable.
WARNING: TLS must not be used to switch hazardous voltages. It is rated for 24Vdc Maximum.
n
Maximum current is 250mA. Ensure a proper dropping resistor is used to limit current to 250mA or less.
Excess current or voltage can permanently damage the product and may pose a shock or fire hazard.
Extended Range (XRE). 10 Vdc excitation for Extended Range transducers. Allows measurement of much
lower tension than usual. Transducers must also have the XR option. Jumper selectable to 5Vdc or 10Vdc.
4
1.7 ACCESSORIES
Remote Tension Meter. Analog, 1 mA (DFE P/N: 722-1385) supplied as a single unit. Must be installed by
user. This meter is also available in its own enclosure (DFE P/N: 723-2682) for CE compliant models. See
Specifications for standard scales. Any other meter scale can be made for an additional charge
IMPORTANT: Both Ti17C and Ti18C models require a meter in enclosure along with a properly shielded
!
cable to maintain CE approval if an accessory meter is used. See Section 2.3 for more information.
5
SECTION 2
2.1 DIMENSIONS inches (mm)
INSTALLATION
Figure 3 - HORIZONTAL MOUNTING DIMENSIONS
Figure 4 - VERTICAL BRACKET MOUNTING DIMENSIONS
6
Figure 5 - ACCESSORY TENSION METER DIMENSIONS (DFE Part# 722-1385)
Figure 6 - ACCESSORY TENSION METER ENCLOSURE DIMENSIONS (DFE Part# 723-2682)
2.2 SELECTION OF MOUNTING LOCATION
To ensure safety and proper operation, the Ti17C or Ti18C must be located away from dusty or wet environ­ments. The Ti17C or Ti18C Horizontal configuration should be installed in a cabinet or enclosure. The vertical mount configuration should be mounted to a secure wall or surface that can support in excess of 10 lbs. (4.6 kg).
2.3 SAFETY AND EMC REQUIREMENTS
n WARNING If this equipment is not connected or operated in the manner specified, the operating safety of this unit or of connected equipment cannot be guaranteed.
WARNING: The isolated output is designed to prevent ground loops and noise. It is not intended or approved
n for safety isolation of hazardous voltages. Do not install unit where isolated circuit and chassis ground are more than 40Vpk differential.
WARNING: Ti17C models require the full case and cover for CE approval and UL/cUL Listing. Operating
n without a properly installed cover invalidates CE approval and UL/cUL Listing and may pose a shock hazard.
7
2.3 SAFETY AND EMC REQUIREMENTS continued...
n
WARNING: Ti17C and Ti18C models require the full case and properly installed cover for UL/cUL Listing.
Operating without a properly installed cover invalidates UL/cUL Listing and may pose a shock hazard.
The cover installation hardware must be fully installed per the following:
The male stud sticking out of the cover requires solid ground bonding to the case for safety. See Figure 7. An M3 star washer (DFE P/N 124-0040) must be installed over the stud before inserting the cover into the base enclosure. After inserting the cover with the M3 star wedged between case and cover, install the three remaining pieces of hardware. Place another M3 star (DFE P/N 124-0040) on the stud first, a split lock washer (DFE P/N
124-0080) second, and the nut (DFE P/N 125-0012) last. Tighten the nut to 0.79N-m (7 in-Lb) of torque for
proper compression and retention. Install the other three M3 screws into the cover to complete the installation.
NOTE: This process needs to be performed any time the cover is removed to ensure safety from shock hazards.
To minimize the need to remove the cover for wiring changes or installation, consider using the accessory Spring Clamp Mating Terminal Block (DFE P/N: 721-2152). This allows wiring changes without removing the cover.
Figure 7 - COVER STUD HARDWARE INSTRUCTIONS
! IMPORTANT: The DFE Model Ti17C you have purchased has been tested and meets the European Union's
Low Voltage Directive, EMC Directive, and is UL/cUL LISTED only when the available enclosure and cover have been purchased and when installation is done correctly. For safety reasons, it is necessary to use appropriate wiring for your line voltage connections and for safety grounding. Make your ground connection between a reliable earth ground and the safety ground of your indicator using a wire with a gauge of at least 16
2
AWG (or a cross-sectional area of at least 1mm voltage connections with wire gauge of at least 16 AWG (or a cross-sectional area of at least 1mm
) and insulation rating of at least 600V. Make your AC line
2
) and insulation rating of at least 600V for each conductor. Secure this wiring to prevent inadvertent removal or strain on the input terminal.
An external switch or circuit breaker is required for power disconnection on the Ti17C, and it is
recommended that this switch or circuit breaker be near the equipment, and be well labeled.
In addition, to meet the EMC Directive, a proper transducer installation, including shielded cables must also
be used. The following is a list of cables available from DFE which meet this requirement:
721-0084 CN 3-conductor cable for type C, RS, THN, and UPB transducers. Use 2 cables, 1 cable per transducer. 721-0964 CN 6-conductor cable for type RFA, LT, VNW, and TR and NW transducers. 721-0984 CN 6-conductor cable for NWI and TR2 (prior to Oct. 2010). Other cables manufactured by DFE also meet this requirement. Contact DFE for more information.
8
2.3 SAFETY AND EMC REQUIREMENTS continued...
In addition to the transducer cable shielding, a shielded meter cable (DFE P/N: 721-0967, 15 ft., other lengths available) and meter in enclosure (DFE P/N: 723-2682) are required to meet the EMC directive when an accessory meter is used.
Cable shielding must be attached to the SHIELD connection on the terminal block, or to an appropriately grounded enclosure. If you wish to assemble your own cables, contact DFE for assembly instructions.
! IMPORTANT: The DFE Model Ti18C you have purchased has been tested and meets the European Union's
Low Voltage Directive and EMC Directive only when installation is done correctly. To meet the EMC Directive, a proper transducer installation, including shielded cables must be used. The following is a list of cables available from DFE which meet this requirement:
721-0084 CN 3-conductor cable for type C, RS, THN, and UPB transducers. Use 2 cables, 1 cable per
transducer.
721-0964 CN 6-conductor cable for type RFA, LT, VNW, and TR and NW transducers.
721-0984 CN 6-conductor cable for NWI and TR2 (prior to Oct. 2010).
Other cables manufactured by DFE also meet this requirement. Contact DFE for more information.
In addition to the transducer cable shielding, a shielded meter cable (DFE P/N: 721-0967, 15 ft., other lengths available) and meter in enclosure (DFE P/N: 723-2682) are required to meet the EMC directive when an accessory meter is used.
Cable shielding must be attached to the SHIELD connection on the terminal block, or to an appropriately grounded enclosure.
In addition to the above, the DFE Model Ti18C is UL/cUL LISTED only in its full enclosure version with cover.
2.4 INSTALLATION INSTRUCTIONS
Drill your mounting holes for the mounting style you will be using. Be sure to allow ample clearance beside or in front of the unit for tool access and for wiring.
If you are using the vertical mounting style without the DIN rail option, drill and tap 2 holes 2.26" (57.4 mm) apart vertically. Insert your M4 or #8 screws and tighten. When tight, reverse them out 3 turns. Place the enclosure keyholes over the screw heads and lower unit into place. Tighten the screws. If you are using the horizontal mounting style, mount the indicator circuit card to your panel. If an optional analog meter is used, drill mounting holes per dimensions in Figure 4 or Figure 5.
9
2.5 TRANSDUCER VOLTAGE SELECTION (Refer to Figure 8)
The tension transducers are excited by either the standard 5 Vdc or, 10 Vdc with the Extended Range option or LT (low tension) transducer.
!!CAUTION Do NOT use the 10 Vdc excitation unless the transducers are LT type transducers or have the
extended range option! The transducers MAY be DAMAGED!
Set the transducer excitation jumpers as follows:
5 Vdc - Jumper on JP1, pins 1-2. 10 Vdc (XRE) - Jumper on JP1, pins 2-3.
Figure 8 - TRANSDUCER VOLTAGE JUMPERS
2.6 TENSION AND METER OUTPUT SELECTION
Verify that your Ti17C or Ti18C is setup with the correct tension and meter output.
For Tension Output see jumpers JP2 and JP3 on the main board. (Figure 9 below). If 0-10V is required, place jumpers on pins 1 to 2 on both JP2 and JP3. If 4-20mA is required, place jumpers on pins 2 to 3 on both JP2 and
NOTE: Both jumpers must be in the same position or incorrect operation will result.
JP3.
Jumper JP4 determines the output level to the accessory meter on TB1 pins 4(+) to 6(-). The default position (for use with 0-1mA meters) is the mA position. For 0-100μA meters, move the jumper to the μA position.
Figure 9 - TENSION and METER OUTPUT JUMPERS
10
2.7 ELECTRICAL CONNECTIONS - STANDARD
The indicator is designed to provide a 0-1mA damped meter output, and either a 0-10V isolated OR a 4-20mA isolated output.
Make your wiring connections as follows:
1. The insulation rating of all line voltage wiring must be at least 600V
2. Keep line voltage wiring physically separated from signal wiring at the terminal block and at any other point
in the installation.
3. Connect cable shields to the Shield terminal on TB1 (Pin 11).
Figure 10 - STANDARD ELECTRICAL CONNECTIONS
11
2.8 TENSION LIMIT SWITCH EXTERNAL RELAY CONNECTIONS (Option)
Figure 11 - TLS EXTERNAL RELAY CONNECTIONS (Option)
12
SECTION 3
CALIBRATION and SETUP
3.1 PREPARATION
1. Select an appropriate calibration weight. Remember that the weight determines the value of web tension that
will produce full output of the Ti17C/Ti18C. A 15lb. weight will result in full output at 150 lbs. tension. (If
the optional cal. ratio of 25% is used, a calibration weight of 15 lbs. will result in a full output at 60 lbs.
tension). A spring scale can also be used, but absolute accuracy may be reduced.
2. Get a length of rope, wire, or cable of appropriate length. It must NOT be extensible (stretchy). This will
cause inaccurate calibration.
3. If you wish to use a calibration ratio of 25%, locate jumper JP6 on the PCB and move it to the 25% position.
3.2 MECHANICALLY ZERO THE TENSION METER
(This step is necessary only if the optional analog tension meter is to be used).
Turn off power to the Ti17C or Ti18C and observe whether the tension meter needle rests at 0. If not, turn the adjustment screw on the rear of the meter as required to set the meter needle at 0 on the scale.
3.3 CALIBRATE THE OUTPUT FOR ACCURACY
Figure 12 - Ti17C and/or Ti18C PC BOARD (enlarged for clarity)
1.
ZERO: Ensure nothing is hanging on or pressing on the tension roll (including the calibration rope). Press the
ZERO pushbutton on the unit front panel for at least 1 second. The unit will store the tension zero one
second after the button is pressed. The unit will flash the green LED (located to the left of JP1) to indicate
the zero has been stored. Release the button. The output will produce 0Vdc or 4mA depending upon the
output selected. The tension meter (if attached) will read zero.
13
3.3 CALIBRATE THE OUTPUT FOR ACCURACY continued...
2.
CALIBRATION: Fasten one end of the rope in the machine and thread the other end around the transducer roll
in exactly the same path the web will take. Be sure the rope does not pass around any driven rolls, drag bars,
or anything else that can affect tension. Ideally the rope should hit an idler roll immediately before and after
the tension sensing roll. It does not have to pass over any other rollers once these three are strung. Refer to
Figure 13.
1. Attach the weight to the free end of the rope as shown in Figure 13. The weight should not touch anything. Wait for the weight to stop swinging.
Figure 13 - WEB PATH
2. Press the CAL pushbutton on the unit front panel for at least 1 second. The unit will store the calibration information one second after the button is pressed. The unit will flash the green LED (located to the left of JP1) to indicate the calibration has been stored. The output will read 1.0Vdc or 5.6mA (For 10% calibration percentage) or 2.5Vdc or 8mA (For 25% calibration percentage). The meter will read 10% of full scale or 25% depending upon JP6 setting.
3. Remove the weight and observe the output. It should read 0Vdc or 4mA with nothing touching the tension sensing roller, and if steps 2.1 to 2.3 above were done correctly.
METER DAMPING: If the optional analog meter is used, adjust the MTR DAMP potentiometer while the
3. machine is running to minimize needle movement. Damping only affects the 0-1mA meter output and not the 0-10Vdc or 4-20mA isolated outputs. (See Fig. 12).
DUAL CALIBRATION: For dual calibration only, connect a jumper between terminals 3 and 7 of TB1 and
4. repeat steps 1 (ZERO) through 2 (CALIBRATION). This sets zero and cal for circuit B. Note: You must keep JP6 (Cal % jumper) in the same position for both calibration runs. When the TB1-3/7 jumper is installed, “B” calibration is active. With CAL A/B tied to ground, ZERO and CAL button presses apply to “B”. With nothing connected to CAL A/B, the unit defaults to “A” calibration.
AUTO-ZERO: If you want the unit to automatically re-zero every time power is applied, move jumper JP7 to
5. pins 2-3 (Auto-Zero ON). The default is Auto-Zero OFF (JP7 Pins 1-2). (See Fig. 12).
!CAUTION: Auto-Zero must be used with care. If power can be cycled to the unit (for any reason) while the
web is resting on the tension roller, Auto-Zero should NOT be activated. The unit will store the updated tension input as the new zero on power up. This can damage the web as the actual tension would be higher than reported by the unit.
6. Manual re-zero can be performed at any time. Simply ensure nothing is touching the tension roller, and press ZERO until the green LED (to the left of JP1) flashes, then release. The zero setting is updated, and the CALIBRATION is maintained.
!CAUTION: Do NOT press ZERO or CAL pushbuttons while the web is running. The unit will store ZERO
or CALIBRATION and the old settings will not be recovered. The only way to recover CALIBRATION is to perform this procedure starting at step 1.
The output calibration is now complete.
14
3.4 CALIBRATION AND ADJUSTMENT OF TENSION LIMIT SWITCH OPTION
The Tension Limit Switch (TLS) option is used to provide a visual LED indication when the tension output
exceeds one value or goes below another value. You can also connect an external relay as shown in Section 2.8 to sound an external alarm, turn the machine off, and so forth.
To calibrate the TLS card, you need to know your system’s full scale tension indication (TFULL). You also
need to decide what you want for your Low tension trip point (TLO) and your high tension trip point (THI). Note that you can set up TLS for one and not the other or both.
NOTE: Your system should be calibrated to measure tension prior to setting up TLS. TLS will not activate
properly if the unit has not been zeroed and calibrated.
!CAUTION: Do NOT press ZERO or CAL push buttons during this procedure. Pressing the CAL button will
invalidate your calibration. Pressing the ZERO button will re-zero the unit. This will not invalidate the calibration, but can cause incorrect zero tension readings if anything is touching the tension sensing roller when the button is pressed.
See Figure 14 or 18 for adjustment locations.
Figure 14 - TENSION LIMIT SWITCH BOARD ADJUSTMENTS
Set Delay: If TLS is to be used, first decide the desired trip delay. This is the amount of time the unit will
1. wait after the tension output crosses the high or low threshold before activating the LED and Open Collector line (TB1 Pin 10). The minimum delay is 32mSec, while the maximum delay is 5 seconds. Most applications should use a delay of 1 second or longer to avoid nuisance trips caused by tension transients. The delay is set by adjusting potentiometer RT802 on the TLS option card.
NOTE: The delay only applies to triggering ON. If TLS is already active, it will turn off immediately when
tension returns to a level between both trip points.
Attach the positive voltmeter lead to the DELAY test point in front of potentiometer RT802 on the TLS option card. Attach the negative voltmeter lead to the ground test point on the TLS option card (test point with ground symbol). The voltage between these two points is equal to the delay in seconds. To set a delay of 1 second, adjust RT802 until 1VDC is read on the voltmeter. For a delay of 4 seconds, adjust RT802 until 4VDC is read on the voltmeter.
Set TLS Low Trip Point: (If only TLS high is needed, turn RT800 25 turns counterclockwise to disable TLS
2. Low. Skip to step 3 after disabling TLS Low.)
NOTE: TLS low is turned off when the LOW test point voltage is 0.1VDC or below.
To set the TLS low trip point, web the process material in the exact path it will run during machine operation. With the web stopped (zero line speed), subject the web to the tension level you desire for TLS low trip point.
15
3.4 CALIBRATION AND ADJUSTMENT OF TENSION LIMIT SWITCH OPTION continued...
A. If the TLS LED is off after setting your tension level, TLS low is either deactivated, or set below the
tension level you have achieved. Slowly turn RT800 clockwise until the LED turns on. Now, slowly turn RT800 counterclockwise until the LED turns off. Your TLS low trip point is now set to the low tension level.
B. If the TLS LED is on after setting your tension level, the TLS low trip point is above your tension level.
Slowly turn RT800 counterclockwise until the LED turns off. Your TLS low trip point is now set to the low tension level.
NOTE: If you are unable to subject the web material to the low tension trip point at zero speed, see the table
in Figure 16 below to set the trip point using a multi-meter only.
3.
Set TLS High Trip Point: (If only TLS low is needed, turn RT801 25 turns clockwise to disable TLS High.)
NOTE: TLS High is turned off when the HIGH test point voltage is 0.1VDC or below. It is also turned off
when HIGH test point is within 0.1VDC of the 5V power voltage rail.
To set the TLS high trip point, web the process material in the exact same path it will run during machine operation. With the web stopped (zero line speed), subject the web to the tension level you desire for TLS high trip point.
A. If the TLS LED is off after setting your tension level, TLS high is either deactivated, or set above the
tension level you have achieved. Slowly turn RT801 counterclockwise until the LED turns on. Now, slowly turn RT801 clockwise until the LED turns off. Your TLS high trip point is now set to the high tension level.
B. If the TLS LED is on after setting your tension level, the TLS high trip point is below your tension level.
Slowly turn RT801 clockwise until the LED turns off. Your TLS high trip point is now set to the high tension level.
NOTE: If you are unable to subject the web material to the high tension trip point at zero speed, see the table
in Figure 15 below to set the trip point using a multi-meter only.
TLS TRIP PERCENTAGE
OF FULL OUTPUT
5% 0.35V 0.35V
10% 0.58V 0.58V
20% 1.05V 1.05V
30% 1.51V 1.51V
40% 2.00V 2.00V
50% 2.48V 2.48V
60% 2.95V 2.95V
70% 3.45V 3.45V
80% 3.91V 3.91V
90% 4.38V 4.38V
95% 4.62V 4.62V
Figure 15 - TENSION LIMIT SWITCH TEST POINT VALUES
TLS LOW TESTPOINT VDC
(RT800)
TLS HIGH TESTPOINT VDC
(RT801)
16
SECTION 4
Your tension interface / indicator will indicate tension in your system without any further operator intervention. It is a good idea to make a check at roughly one month intervals to verify that no one has changed the calibration. See Section 3 for calibration and setup.
OPERATING INSTRUCTIONS
17
SECTION 5
It is not necessary to perform any type of maintenance on the indicator. However, you may find it worthwhile to observe whether there is a buildup of dust, debris, or moisture on or near the unit after a period of time. If so, you may consider putting the unit in a more appropriate location.
CARE AND MAINTENANCE
18
SECTION 6
Most problems are caused by incorrect installation and misapplication of the equipment. It is very important
to be sure these factors are correct before making any changes to calibration and jumper settings.
The green status LED (located to the left of JP1-ref. Fig 12, pg. 13) indicates the operating status of the unit.
It should be on steadily within one second of power application. The green status LED should not be flashing during operation except when pressing ZERO or CALIBRATION pushbuttons (LED will flash once indicating acceptance of ZERO or CAL). Continuous flashing is an indication of a problem, contact DFE technical support if this condition is observed.
If the green status LED is not lit when power is applied, check fuses on the Ti17C or Ti18C. If they need to
be replaced, use the correct values listed below (all fuses 5mm x 20mm type):
Ti17C (2 Fuses):
Ti18C (1 Fuse): 500mA, 250V IEC Fast Acting
n
WARNING: Equipment must be disconnected from HAZARDOUS LIVE voltage before changing the fuses.
115V Operation 230V Operation
160mA, 250V IEC Fast Acting 80mA, 250V IEC Fast Acting
(DFE P/N: 108-0082) (DFE P/N: 108-0091)
(DFE P/N: 108-0097)
TROUBLESHOOTING GUIDE
n
WARNING: Only replace fuses with the correct size, value, and speed rating. Use of non-certified fuses or
fuses with incorrect ratings invalidates CE approval and or UL/cUL LISTING of the product. Incorrect fusing
MAY CAUSE A SHOCK OR FIRE HAZARD.
The test points on the circuit card can provide an indication of proper operation or problems if they exist.
Typical voltages on the test points follow:
Voltmeter positive lead Voltmeter negative lead Typical Voltage
TP1 TP3 15.5 Vdc
TP9 TP3 5Vdc
TP4 (+EXC) TP3 5Vdc (STD), 10.1Vdc (XR)
TP5 TP11 0-10Vdc output, changes depending on
tension input and ZERO/CAL settings.
Some variation of the listed voltages should be expected. If any voltage deviation greater than 10% of typical
is measured, contact DFE technical support for assistance.
If you have any problems with the functions on your Ti17C or Ti18C Tension Indicator, please call Technical
Service at 603-332-6150 or Fax 603-332-3758. E-mail: techsupport@dfe.com.
DFE’s experienced technicians are responsible to ensure that you are satisfied with your DFE equipment.
They will be pleased to assist you.
19
SECTION 7
See diagram below for separate components.
n
WARNING: When replacing fuses, use only fuses with ratings as shown below. Failure to do this may compromise
personal safety and may create a fire hazard!
REPLACEMENT PARTS
Figure 16 - REPLACEMENT PART NUMBERS
20
Appendix A: Locations of Jumpers and Adjustments
List of Jumpers: JP1 - Transducer Excitation: 5V std, 10V XRE. JP2 - Tension Output - 0-10V or 4-20mA..
Default is 0-10V. Must match JP3
JP3 - Tension Output; 0-10V or 4-20mA. Must
match JP2.
JP4 - Meter Output; 0-1mA or 0-100μA. Default
is 0-1mA.
JP5 - 115VAC or 230VAC input. Ti17C only.
Factory set..
JP6 - Calibration weight to total tension
percentage; 10% or 25%. Default is 10%.
JP7 - Auto Zero; OFF or ON. Default is OFF.
Figure 17 - Ti17C / Ti18C PC BOARD with JUMPER LIST AND LOCATIONS
(Enlarged for clarity)
Figure 18 - OPTIONAL TENSION LIMIT SWITCH BOARD (Enlarged for clarity)
21
Appendix B: Electrical Connections
Ti17C/Ti18C STANDARD CONNECTIONS:
Make your wiring connections as follows:
1. The insulation rating of all line voltage wiring must be at least 600V.
2. Keep line voltage wiring physically separated from signal wiring at the terminal block and at any other point in the installation.
3. Connect cable shields to earth ground.
Figure 19 - STANDARD ELECTRICAL CONNECTIONS
22
TENSION LIMIT SWITCH EXTERNAL RELAY CONNECTIONS (Option):
Figure 20 - TLS EXTERNAL RELAY CONNECTIONS (OPTION)
23
Appendix C: Transducer Electrical Connections
Figure 21 - MODELS C, RS, & F TRANSDUCER WIRING
24
Figure 22 - RFA TRANSDUCER WIRING
25
Figure 23 - TR & NW TRANSDUCER WIRING
26
Figure 24 - LT TRANSDUCER WIRING
27
Appendix D: Typical Tensions for Various Materials
TYPICAL TENSIONS FOR WEB MATERIALS
ACETATE 0.5 lb. per mil per inch of width
FOIL Aluminum 0.5 lb. per mil per inch of width
Copper 0.5 lb. "
CELLOPHANE 0.75 lb. per mil per inch of width
NYLON 0.25 lb. per mil per inch of width
PAPER 15 lb * 0.4 lb. per inch of width
20 lb 0.5 lb. " 30 lb 0.75 lb. " 40 lb 1.25 lb. " 60 lb 2.0 lb. " 80 lb 3.0 lb. " 100 lb 4.0 lb. "
* based on 3000 sq. ft. ream
PAPERBOARD 8pt 3.0 lb. per inch of width
12pt 4.0 lb. " 15pt 4.5 lb. " 20pt 5.5 lb. " 25pt 6.5 lb. " 30pt 8.0 lb. "
POLYETHYLENE 0.12 lb. per mil per inch of width
POLYESTER (Mylar) 0.75 lb. per mil per inch of width
POLYPROPYLENE 0.25 lb. per mil per inch of width
POLYSTYRENE 1.0 lb. per mil per inch of width
RUBBER
SARAN 0.15 lb per mil per inch of width
STEEL
GAUGE AT 25% STRETCH AT 50% STRETCH
10 mil 1.75 3.68 12 mil 1.10 2.03
16.5 mil 4.09 8.17 26 mil 2.47 4.97
GAUGE - INS UNWIND-PSI REWIND-PSI
0.001 -0.005 1000 4000
0.006 -0.025 850 3500
0.026 -0.040 750 3000
0.041 -0.055 650 2600
0.058 -0.070 550 2200
0.071 -0.090 450 1800
0.091 -0.120 450 1400
0.121 -0.140 400 1200
0.141 -0.165 400 1000
0.166 -0.200 400 900
0.201 -0.275 400 800
0.276 -0.380 300 700
VINYL 0.05 lb. per mil per inch of width *** For laminated webs, sum the tension for the individual webs and add 0.1 lb per inch of width.
28
Appendix E: Environmental Terms
OVERVOLTAGE CATEGORY: Classification of parts of installation systems or circuits with standardized limits
for transient overvoltages, dependent on the normal line voltage to earth.
POLLUTION: Any addition of foreign matter, solid, liquid or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity.
POLLUTION DEGREE 2: Normally only non-conductive POLLUTION occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
29
TERMS AND CONDITIONS OF SALE AND SHIPMENT
1. THE COMPANY
Dover Flexo Electronics, Inc. is hereinafter referred to as the Com­pany.
2. CONFLICTING OR MODIFYING TERMS No modification of, additions to or conflicting provisions to these
terms and conditions of sale and shipment, whether oral or written, incorporated into Buyer's order or other communications are binding upon the Company unless specifically agreed to by the Company in writing and signed by an officer of the Company. Failure of the Company to object to such additions, conflicts or modifications shall not be construed as a waiver of these terms and conditions nor an acceptance of any such provisions.
3. GOVERNING LAW
This contract shall be governed by and construed according to the laws of the state of New Hampshire, U.S.A. The parties agree that any and all legal proceedings pursuant to this contract shall take place under the jurisdiction of the courts of the State of New Hamp­shire in the judicial district of Strafford County.
4. PENALTY CLAUSES Penalty clauses of any kind contained in orders, agreements or any
other type of communication are not binding on the Company unless agreed to by an officer of the Company in writing.
5. WARRANTY
Dover Flexo Electronics,Inc. warrants, to the original Buyer, its' products to be free of defects in material and workmanship for five years from date of original shipment. Repairs on products are warranted for 90 days from date of shipment. During the warranty period the Company will repair or replace defective products free of charge if such products are returned with all shipping charges prepaid and if, upon examination, the product is shown to be defec­tive. This warranty shall not apply to products damaged by abuse, neglect, accident, modification, alteration or mis-use. Normal wear is not warranteed. All repairs and replacements under the provisions of this warranty shall be made at Dover Flexo Electronics or at an authorized repair facility. The Company shall not be liable for ex­penses incurred to repair or replace defective products at any other location or by unauthorized persons or agents. This warranty con­tains all of the obligations and warranties of the Company. There are no other warranties, either expressed or implied. No warranty is given regarding merchantability or suitability for any particul purpose. The Company shall not be liable in either equity or law for consequential damages, losses or expenses incurred by use of or inability to use its' products or for claims arising from same. No warranty is given for products of other manufacturers even though the Company may provide these products with its' own or by them­selves. The provisions of this warranty can not be changed in any way by any agent or employee of the Company. Notice of defects must be received within the warranty period or the warranty is void. The warranty is void if the serial number tag is missing or not readable.
6. PAYMENTS
Standard terms of credit are net 30 days from date of shipment, providing satisfactory credit is established with the Company. Amounts past due are subject to a service charge of 1.5% per month or portion thereof or 18% per annum. The Company reserves the right to submit any unpaid late invoices to a third party for collection and Buyer shall pay all reasonable costs of such col­lection in addition to the invoice amount. All quoted prices and pay­ments shall be in U.S. Dollars.
If the Company judges that the financial condition or payment practices of the Buyer does not justify shipment under the standard terms or the terms originally specified, the Company may require full or partial payment in advance or upon delivery. The Company re­serves the right to make collection on any terms approved in writing by the Company's Finance Department. Each shipment shall be considered a separate and independent transaction and payment therefore shall be made accordingly. If the work covered by the purchase order is delayed by the Buyer, upon demand by Company
ar
payments shall be made on the purchase price based upon percentage of completion.
7. TAXES
Any tax, duty, custom, fee or any other charge of any nature whatsoever imposed by any governmental authority on or measured by any transaction between the Company and the Buyer shall be paid by the Buyer in addition to the prices quoted or invoiced.
8. RETURNS
Written authorization must be obtained from the Company's factory before returning any material for which the original Buyer expects credit, exchange, or repairs under the Warranty. Returned material (except exchanges or repairs under the Warranty) shall be subject to a minimum re-stocking charge of 8%. Non-standard material or other material provided specially to the Buyer's specification shall not be returnable for any reason. All material returned, for whatever reason, shall be sent with all freight charges prepaid by the Buyer.
9. SHIPPING METHOD AND CHARGES
All prices quoted are EXW the Company's factory. The Company shall select the freight carrier, method and routing. Shipping charg­es are prepaid and added to the invoice of Buyers with approved credit, however the Company reserves the right to ship freight­collect if it prefers. Shipping charges will include a charge for packaging. Company will pay standard ground freight charges for items being returned to Buyer which are repaired or replaced under the Warranty. Claims of items missing from a shipment must be received, in writing, within 30 days of original shipment
10. CANCELLATION, CHANGES, RESCHEDULING
Buyer shall reimburse Company for costs incurred for any item on order with the Company which is cancelled by the Buyer. Costs shall be determined by common and accepted accounting practices.
A one-time hold on any item ordered from the Company shall be allowed for a maximum of 30 days. After 30 days, or upon notice of a second hold, Company shall have the right to cancel the order and issue the appropriate cancellation charges which shall be paid by Buyer. Items held for the Buyer shall be at the risk and expense of the Buyer unless otherwise agreed upon in writing. Company reserves the right to dispose of cancelled material as it sees fit without any obligation to Buyer.
If Buyer makes, or causes to make, any change to an order the Company reserves the right to change the price accordingly.
11. PRICES
Prices published in price lists, catalogs or elsewhere are subject to change without notice and without obligation. Written quoted prices are valid for thirty days only.
12. EXPORT SHIPMENTS
Payment for shipments to countries other than the U.S.A. and Canada or to authorized distributors shall be secured by cash in advance or an irrevocable credit instrument approved by an officer of the Company. An additional charge will apply to any letter of credit. There will also be an extra charge for packaging and documentation.
13. CONDITION OF EQUIPMENT
Buyer shall keep products in good repair and shall be responsible for same until the full purchase price has been paid.
14. OWNERSHIP
Products sold are to remain the property of the Company until full payment of the purchase price is made.
terms.9 1/25/18
30
DECLARATION OF CONFORMITY
We,
Dover Flexo Electronics 217 Pickering Road Rochester, NH 03867 USA Tel: (603) 332-6150 Fax: (603) 332-3758
declare under our sole responsibility that the product:
Ti17CV Web Tension Interface (with (COV) option),
manufactured after the date: 4 September 2007, and to which this declaration relates, is in conformity with the following standards or other normative documents:
EN 55011: Radiated and Conducted Emissions, Class A EN 61326-1:2006: Electromagnetic compatibility - Generic immunity standard EN 61000-4-2: Electrostatic Discharge, 4kV Contact / 8kV Air Discharge EN 61000-4-3: Radiated Susceptibility, Level 3 Annex D EN 61000-4-4: Electrical Fast Transient Immunity, Level 3 EN 61000-4-5: Surge Immunity, Level 3 EN 61000-4-6: Conducted Susceptibility, Level 2 EN 61000-4-8: Magnetic Field Immunity EN 61000-4-11: Voltage Interrupt Immunity
following the provisions of Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of the member states relating to electromagnetic compatibility (the "EMC Directive"); and also
EN 61010-1:2001: Safety requirements for electrical equipment for measurement, control, and laboratory use.
following the provisions of Council Directive 73/23/EEC on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits (the "Low Voltage Directive").
The Technical Construction File is maintained at:
Dover Flexo Electronics 217 Pickering Road Rochester, NH 03867 USA
Per Annex II R of the Machinery Directive (89/392/EEC):
The machinery, product, assembly, or sub-assembly covered by this Declaration of Conformity must not be put into service until the machinery into which it is to be incorporated has been declared in conformity with the provisions of the applicable Directive(s).
Date of issue: 4 September, 2007 Place of issue: Rochester, NH USA
Signed:_____________________________________________
Brian Dow, Engineering Manager
31
8012184.doc
DECLARATION OF CONFORMITY
We,
Dover Flexo Electronics 217 Pickering Road Rochester, NH 03867 USA Tel: (603) 332-6150 Fax: (603) 332-3758
declare under our sole responsibility that the product:
Ti18C Web Tension Interface,
manufactured after the date: 4 September 2007, and to which this declaration relates, is in conformity with the following standards or other normative documents:
EN 55011: Radiated Emissions, Class A EN 61326-1:2006: Electromagnetic compatibility - Generic immunity standard EN 61000-4-2: Electrostatic Discharge, 4kV Contact / 8kV Air Discharge EN 61000-4-3: Radiated Susceptibility, Level 3 Annex D
following the provisions of Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of the member states relating to electromagnetic compatibility (the "EMC Directive"); and also
EN 61010-1:2001: Safety requirements for electrical equipment for measurement, control, and laboratory use.
following the provisions of Council Directive 73/23/EEC on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits (the "Low Voltage Directive").
The Technical Construction File is maintained at:
Dover Flexo Electronics 217 Pickering Road Rochester, NH 03867 USA
Per Annex II R of the Machinery Directive (89/392/EEC):
The machinery, product, assembly, or sub-assembly covered by this Declaration of Conformity must not be put into service until the machinery into which it is to be incorporated has been declared in conformity with the provisions of the applicable Directive(s).
Date of issue: 4 September, 2007 Place of issue: Rochester, NH USA
Signed:_____________________________________________
Brian Dow, Engineering Manager
8012185.doc
32
INDEX
0-1 mA ........................................................... 3, 4
0-10 Volt Tension Output .............................. 3, 4
0-100μA ........................................................4, 10, 21
230 Volt Power .............................................. 3, 5, 19
4-20mA .......................................................... 3, 5
AC Power Connections ................................ 4,11, 22
Accessories ................................................... 5
Auto Zero .......................................................5
Cables ........................................................... 8, 9
Calibration,
range ......................................................... 3
tension meter ............................................. 13
Care and Maintenance .................................. 18
CE Mark .................................................. 1, 5, 7, 8, 9
Circuit Card ................................................. 1, 20, 21
connector .................................................. 1, 5, 20
Cover .......................................................... 2, 5, 8, 20
Declaration of Conformity .............................. 31,32
Descriptions ................................................... 1
Dimensions .................................................... 6-7
Din Rail Clip ................................................... 2, 5, 6
Disassembly .................................................. 1-2
Dual Calibration ............................................. 4, 14
Electrical Connections
standard. .................................................... 11, 22
optional ...................................................... 12, 23
transducer .................................................. 24-27
Enclosure ...................................................... 2, 6, 20
Environmental Conditions ............................. 3
terms .......................................................... 30
Excitation ..................................................... 3, 10, 11
Exploded View ............................................... 1-2
Extended Range ............................................ 3, 5
Fuses ......................................................... 13, 20-21
Operating Instructions ................................... 17
Options .......................................................... 5
Output Response Time ................................. 3
Outputs,
0-1 mA ....................................................... 3, 4
4-20mA ...................................................... 3, 5, 22
0 to +10V ................................................... 3, 4, 22
Power Voltage ............................................... 4, 5
PC Boards ..................................................... 20, 21
Quik-Cal
Replacement Parts ........................................ 20
Safety Requirements ..................................... 7
Set-up ............................................................ 13
Specifications ................................................ 3
Standard Features ......................................... 4
Tension Limit Switch .................... 1, 5, 12, 15-16, 21
Tension Meter ................................................ 3,13
Temperature Range ...................................... 3
Terminal Block Connector ........................ 1, 2, 5, 20
Terms & Conditions of Sale ........................... 30
Test Points .................................................... 19
Transducer,
Troubleshooting ............................................. 19
Typical Tensions ............................................ 28
UL/cUL Listing .................................. 1, 6, 7, 8, 9, 19
Warranty ........................................................30
Weight ........................................................... 3
...................................................... a, 1, 4
output ......................................................... 10, 11
cables ........................................................ 8, 9
connections ............................................... 24-27
excitation .................................................. 3, 10, 11
input ...........................................................3
Input ............................................................... 3
Installation ..................................................... 6
Isolation from Earth Ground .......................... 4
Meter,
analog ........................................................ 3
calibration .................................................. 13-14
damping ..................................................... 4, 14
dimensions ................................................ 7
mechanical Zero ........................................ 13
meter scales .............................................. 3
non-standard meter scales ........................ 5
output selection ......................................... 10
remote tension meter ................................. 5
Mounting Location ......................................... 7
Zero ............................................................... 13
range ......................................................... 3
33
217 PICKERING ROAD
ROCHESTER, NEW HAMPSHIRE 03867-4630 U.S.A
TEL: 603-332-6150
FAX: 603-332-3758
E-mail: info@dfe.com Internet: www.dfe.com
CANADA
MEXICO
UNITED KINGDOM
TAIWAN
KOREA
AUSTRALIA
SOUTH AFRICA
CHINA
©2018 DOVER FLEXO ELECTRONICS, INC DOC 801-2169 R8 ALL RIGHTS RESERVED PRINTED IN USA
Loading...