OPERATOR’S MANUAL
for DCBD120HC-(10/39)BD Series Dryers
The dryer must not be stored or installed where it will be exposed to water and/or weather.
WARNING: For your safety the infor­mation in this manual must be fol­lowed to minimize the risk of fire or explosion or to prevent property dam­age, personal injury
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Clear the room, building or area of all occupants.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
– Installation and service must be performed by
a qualified installer, service agency or the gas supplier.
Post the following “For Your Safety” caution in a prominent location:
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other a
It is important that yo u read this Manual and ret ain it for future reference. For service or replacement parts, contact the distributor in your area or the manufacturer.
FOR YOUR SAFETY
liance.
or loss of lif e.
Dexter Laundry Inc.
2211 West Grimes Avenue
Fairfield, Iowa 52556
AVERTISSEMENT. Assurez-vouz de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matérial, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
– QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment où vous trouvez.
• Évacuez la pièce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incendies.
– L’installation et l’entretien doivent être assures
par un installateur ou un service d’entretien qualifie ou par le fournisseur de gaz.
POUR VOTRE SÉCURITÉ
Ne pas ente poser ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
You, the purchaser, must post in a prominent loca­tion instructions to be followed in the event the user smells gas. Consult your local gas supplier for pro­cedure to be followed if the odor of gas is present.
TABLE OF CONTENTS
PAGE NO.
DRYER DIMENSIONS (Figure 1) ...............................................…..................... 3
UNCRATING ...........….................................................................…................. 6
DRYER INSTALLATION ................................................................................... 6
DRYER SHUTDOWN ....................................................................................... 10
DRYER CONTROLLER INTERFACE (Figure 3) …………………………………………………. 11
DRYER CONTROLLER FACTORY DEFAULT PROGRAM SETTING .......................... 12
DRYER FAULT CODES ..........................…........................................................ 12
TOUCH PAD DESCRIPTION .................…......................................................... 13
OPERATING INSTRUCTIONS ........................................................................... 15
TEMPORARY REVERSING DRYER CONTROLLER PROGRAMMING ........................16
PERMANENT REVERSING DRYER CONTROLLER PROGRAMMING ........................19
SERVICING DRYER .............................................…......................................... 21
PREVENTATIVE MAINTENANCE .......................…............................................. 22
WARNINGS ABOUT USE AND OPERATION
It is ABSOLUTELY ESSENTIAL that the dryer be grounded to a known earth (zero) ground. This is not only
for personal safety, but is necessary for proper operation.
DO NOT MODIFY THIS APPLIANCE. KEEP SHIELDS, GUARDS, AND COVERS IN PLACE. These safety
devices are provided to protect everyone from injury.
THIS DRYER IS EQUIPPED WITH AN OVER-TEMPERATURE THERMOSTAT located to the right of the motor on the rear of the cabinet. If the dryer cease to operate, refer to your “Service Procedure and Part s Data” book for instructions.
CHECK THIS THERMOSTAT WHEN INSTALLING THE DRYER to assure it is not tripped. Impacts such as rough handling in shipment, may trip the thermostat.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE while in operation.
THIS APPLIANCE SHALL NOT BE USED TO DRY OFF CLOTHES CONTAINING SOLVENTS OR DRY CLEANING
FLUIDS.
- 2 -
DRYER DIMENSIONS- FIGURE 1A
- 3 -
DRYER DIMENSIONS- FIGURE 1B
- 4 -
DRYER DIMENSIONS- FIGURE 1C
- 5 -
DRYER CAPACITY
Dryer Model Dry Weight Capacity DCBD120 120 lb (54.5 kg)
INSTALLATION AND OPERATING INSTRUCTIONS
INDUSTRIAL DRYER
UNCRATING
Tools required: 3/4” hex socket and ratchet driver and knife.
1. Remove the plastic wrap with knife. Remove cardboard rails, fillers and top cap.
2. Using a ratchet and a 3/4” socket, remove the (4) bolts attaching the wooden skid to the dryer cabinet. Save
the bolts for future moving of the dryer.
3. With a walking motion, move the dryer forward completely off the wooden skid. Save the skid for future
moving of the dryer.
Note: If the dryer is ever moved again, the dryer should be re-mounted on its pallet and its crating bolts re-
inserted and tightened, in the reverse order as above.
DRYER INSTALLATION
1. CODE CONFORMITY. All commercial dryer installations must conform with local codes or, in the absence
of local codes, with the latest edition of the National Fuel Gas Code ANSI Z223.1A. Canadian installations m ust comply with current Standard CAN/CGA-B149 (.1 or .2) Installation Code for Gas Burning Appliances or Equipment, and local codes if applicable. Australian installations must meet installation requirements and pipe sizing requirements of AS/NZA 5601. The appliance, when installed, must be electrically grounded in accordance with the latest edition of the National Electrical Code, ANSI/NFPA70, or, when installed in Canada, with Standard CSA C22.1 Canadian Electrical Code Part 1.
2. INSTALLATION CLEARANCES. This unit may be installed at the following alcove clearance. (millimeters)
I. Left Side 0”
II. Right Side 0” *
III. Back 18” (457) (Certified for 1” (25) clearance; however, 18” (457) clearance is necessary behind the belt guard to allow servicing and maintenance.)
IV. Front 48” (1220) (to allow use of dryer)
V. Top Refer to figure on the next page labeled “Vertical Clearance Dimensions”.
Certification allows 0” clearance at the top 1” (25) back from the front. However, a 1/4” (6) clearance is required to allow opening the upper service door.
A 10” (254) clearance is required from the top at all other points.
VI. Floor This unit may be installed upon a combustible floor. *Units may be installed in direct contact with an adjacent dryer, providing allowance is made for opening
upper and lower service doors. Do not obstruct the flow of combustion and ventilation air. Maintain minimum of 1” (25) clearance between duct and combustible material. Refer to installation label attached to the inside surface of the upper door of the dryer for other installation
information.
- 6 -
VERTICAL CLEARANCE DIMENSIONS
3. MAKE-UP AIR. Adequate make-up air (1250 CFM (35.4 m³/minute) for 60 Hz machines with 10” exhaust,
1450 CFM (41 m³/minute) for 60 Hz machines with 12” exhaust, 1000 CFM (28.3 m³/minute) for 50 Hz machines with 10”/12” exhaust) must be supplied to replace air exhausted by dryers on all types of installations. Provide a minimum of 2.25 ft² (0.2 m²) make-up air opening to the outside for each dryer. This is a net requirement of effective area. Screens, grills or louvers, which will restrict the flow of air, must be considered. Consult the supplier to determine the free area equivalent for the grill being used.
The source of make-up air should be located sufficiently away from the dryers to allow an even airflow to the air
intakes of all dryers. Multiple openings should be provided.
NOTE: The following considerations must be observed for gas dryer installations where dry cleaners are
installed. The sources of all make-up air and room ventilation air movement to all dryers must be located
away from any dry cleaners. This is necessary so that solvent vapors will not be drawn into the dr yer inlet ducts. Dry cleaner solvent vapors will decompose in contact with an open flame such as the gas flame present in clothes dryers. The decomposition products are highly corrosi ve and will cause damage to the dryer(s), ducts and clothes loads.
4. ELECTRICAL REQUIREMENTS. The electrical power requirements necessary to oper ate the unit satisf actorily are listed on the serial plate located on the back panel of each dryer. The electrical connection should be made to the terminal block in the rear control box assembly on the rear of the unit, using a wire size adequate to handle the amperage and voltage listed on the serial plate, but never smaller than No.12 AWG wire. It is absolutely necessary that the dryer be grounded to a known ground.
Individual circuit breakers for each unit are recommended. The wiring diagram is located on the belt guard on
the back of the machine.
- 7 -