DeWalt DCT419 Instruction Manual

DCT419 12V Max* Hand-Held Wall Scanner Scanner mural portatif de 12V max* Escáner de pared portátil de 12 V Máx*
INSTRUCTION MANUAL GUIDE D'UTILISATION MANUAL DE INSTRUCCIONES
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO.
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, contáctenos.
1-800-4-DEWALT • www.dewalt.com
1
English
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE
Work Area Safety
a) Keep work area clean and well lit. Cluttered or dark areas
invite accidents.
b) Keep children and bystanders away while operating a
hand-held wall scanner. Distractions can cause you to lose control.
Personal Safety
a) Stay alert, watch what you are doing and use common
sense when operating a hand-held wall scanner. Do not use a hand-held wall scanner while you are tired or under the infl uence of drugs, alcohol or medication. A moment
of inattention while operating the hand-held wall scanner may result in serious personal injury.
b) Do not overreach. Keep proper footing and balance at
all times. This enables better control of the hand-held wall scanner in unexpected situations.
c) Dress properly. Do not wear loose clothing or jewelry.
Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in
moving parts.
Use and Care
a) Store an idle hand-held wall scanner out of the reach of
children and do not allow persons unfamiliar with the hand-held wall scanner or these instructions to operate the hand-held wall scanner. Hand-held wall scanners are
dangerous in the hands of untrained users.
b) Use the hand-held wall scanner, accessories and tool
bits, etc. in accordance with these instructions, taking into account the working conditions and the work to be
Defi nitions: Safety Guidelines
The defi nitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols.
DANGER: Indicates an imminently hazardous situation
which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation
which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. NOTICE: Indicates a practice not related to personal injury
which, if not avoided, may result in property damage.
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS OR ANY D
EWALT TOOL, CALL US TOLL FREE AT: 1-800-4-DEWALT (1-
800-433-9258).
WARNING: To reduce the risk of injury, read the instruction
manual.
Important Safety Instructions
• Read these instructions.
• Keep these instructions.
• Heed all warnings.
• Follow all instructions.
• Only use attachments/accessories specifi ed by the manufacturer.
• Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any way, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
2
English
performed. Use of the hand-held wall scanner for operations different from those intended could result in a hazardous situation.
Battery Tool Use and Care
a) Recharge only with the charger specifi ed by DEWALT. A
charger that is suitable for one type of battery pack may create a risk of fi re when used with another battery pack.
b) When battery pack is not in use, keep it away from other
metal objects like paper clips, coins, keys, nails, screws, or other small metal objects that can make a connection from one terminal to another. Shorting the battery terminals
together may cause burns or a fi re.
c) Under abusive conditions, liquid may be ejected from
the battery; avoid contact. If contact accidentally occurs, fl ush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause
irritation or burns.
Safety Information for Hand-Held Wall Scanners
WARNING: Do not disassemble or modify the hand-held wall
scanner. There are no serviceable parts inside. If you need
assistance, contact D
EWALT at 1-800-4-DEWALT (1-800-433-9258)
or go to http://www.dewalt.com on the Internet.
Do not operate the hand-held wall scanner in explosive
atmospheres, such as in the presence of fl ammable liquids, gases, or dust. Hand-held wall scanners create sparks which may
ignite the dust or fumes.
The hand-held wall scanner should only be used with
specifi cally designated D
EWALT batteries. Use of any other
batteries may create a risk of fi re.
Store the hand-held wall scanner out of reach of children and other untrained persons. Tools are dangerous in the hands of untrained users.
Do not disassemble the hand-held wall scanner. There are no user serviceable parts inside.
Do not remove or deface warning labels.
The hand-held wall scanner must remain in contact with the
wall surface during the entire scan.
Optimal operation of the hand-held wall scanner is possible only when the operating instructions are read and followed.
Do not attach any stickers on name plates to the sensor area on the back of the hand-held wall scanner. Metal stickers
especially could affect the measurement results.
Before turning on the hand-held wall scanner, ensure that its back surface is not moist. If required, wipe with a dry cloth before scanning.
Do not expose to extreme temperatures or variations in
temperature. In case of large variations in temperature, allow the unit to adjust to ambient temperature before powering on. Extreme and variations in temperature can impair the display
and accuracy of the tool.
Static electricity may lead to inaccurate detection of
electrical wires.
WARNING: Do not expose hand-held wall scanner or battery
to excessive heat such as sunshine, fi re or the like.
WARNING: Modifi cations not authorized by the manufacturer
may void user's authority to operate this device.
WARNING: The detector alone should not be relied on
exclusively to locate items below the scanned surface. Under
certain circumstances, the scanner may not identify all objects or the exact location of objects. Use other information sources to help locate items before penetrating the surface. Such additional sources include construction plans, visible points of entry of pipes and wiring
3
English
into walls, such as in a basement, and standard 16" (40 cm) and 24" (60 cm) stud spacing practices.
WARNING: You should always use caution when nailing, cutting or drilling in ceilings, walls and fl oors that may contain wiring or pipes near the surface. Shielded, dead or non-powered wires will not be detected as live wires. Remember that studs or
joists are normally spaced 16" (40 cm) or 24" (60 cm) apart and are usually 1-1/2" (38mm) in width. Beware of anything closer together or a different width. Always turn the power off when working near electrical wires. Also, shut off gas and water supplies.
WARNING: To reduce the risk of injury and electric shock,
always turn off power when working near electrical wires. Metal
shielded wires or those in metal conduit will not be detected. Use extreme caution in these circumstances or whenever live AC wiring is present. Test the functionality of the AC, detect on a well known power supply prior to measurement.
WARNING: Live wires deeper than 2" (50.8 mm) from the surface, in plastic conduit, behind plywood sheer wall or metallic wall coverings, cables operating at DC current or wires used in telecommunications and computer systems may not be detected. Wires that are not live may be detected as metal objects.
WARNING: Do not use the tool to detect AC voltage in un­insulated, exposed or free wires. Do not use as a substitute for a
volt meter.
WARNING: Detection values can be impaired through certain ambient conditions. These include the proximity of other equipment
that produce strong magnetic or electromagnetic fi elds, moisture, metallic building materials, foil laminated insulation materials or conductive wall paper or tiles. Use of transmitting systems such as WLAN, UMTS, radar, transmitting masts or microwaves can infl uence the measurements.
CAUTION: Do not use on humans or animals. This is not for
human or animal use and can cause injury if used.
CAUTION: When not in use, place hand-held wall scanner on its side on a stable surface where it will not cause a tripping or falling hazard. Some tools with large battery packs will stand upright
on the battery pack but may be easily knocked over.
• The label on your tool may include the following symbols. The
symbols and their defi nitions are as follows:
V ................... volts A ......................amperes
Hz ................. hertz W .....................watts
min ............... minutes
or AC .......... alternating
or DC ...direct current current
................. Class I Construction or AC/DC ... alternating
.....................
(grounded) ........................ or direct
................. Class II Construction current
(double insulated) no .................... no load
…/min .......... per minute speed
BPM ............. beats per minute
n ...................... rated
IPM ............... impacts per minute
........................ speed
RPM ............. revolutions per
.................... earthing
minute terminal
sfpm ............. surface feet
..................... safety alert
..................... per minute symbol
SPM .............strokes per minute
Detection through Special Surface Conditions
WALLPAPER
The hand-held wall scanner will function normally on walls covered with wallpaper or fabric, unless the materials are metallic foil, contain metallic fi bers or are still wet after application.
4
English
against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
Important Safety Instructions for All Battery Packs
When ordering replacement battery packs, be sure to include catalog number and voltage. Consult the chart at the end of this manual for compatibility of chargers and battery packs. The battery pack is not fully charged out of the carton. Before using the battery pack and charger, read the safety instructions below, then follow charging procedures outlined.
READ ALL INSTRUCTIONS
Do not charge or use battery in explosive atmospheres, such as in the presence of fl ammable liquids, gases or dust.
Inserting or removing the battery from the charger may ignite the dust or fumes.
• NEVER force battery pack into charger. DO NOT modify battery pack in any way to fi t into a non-compatible charger as battery pack may rupture causing serious personal injury.
PLASTER AND LATH
Due to the uneven thickness of plaster, it may be diffi cult to locate studs. It may be easier to identify the metal nail heads in the studs. If the plaster is reinforced with wire mesh, the hand-held wall scanner will not be able to reliably detect embedded materials behind it.
TEXTURED OR ACOUSTICAL WALLS AND CEILINGS
When scanning a wall or ceiling with an uneven surface, place thin cardboard on the surface and scan over the cardboard.
WOOD FLOORING, WOOD SUB-FLOORING AND DRYWALL OVER PLYWOOD
Due to the thickness of these materials, it may be diffi cult to detect a wood stud or joist. It may be easier to detect the metal nails that hold the materials to the stud or joist.
CARPETING
The hand-held wall scanner cannot detect studs or joists through carpeting. It may be easier to detect the metal nails that hold the materials to the stud or joist. NOTE: Sensing depth and accuracy can vary due to moisture, content of the materials, wall texture and paint.
Regulatory Notices
• This Class B digital apparatus complies with Canadian ICES-003.
• This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
5
English
Consult the chart at the end of this manual for compatibility of batteries and chargers.
• Charge the battery packs only in D
EWALT chargers.
DO NOT splash or immerse in water or other liquids.
• Do not store or use the tool and battery pack in locations
where the temperature may reach or exceed 105 °F (40 ˚C) (such as outside sheds or metal buildings in summer).
WARNING: Fire hazard. Never attempt to open the battery pack
for any reason. If battery pack case is cracked or damaged, do not insert into charger. Do not crush, drop or damage battery pack. Do not use a battery pack or charger that has received a sharp blow, been dropped, run over or damaged in any way (i.e., pierced with a nail, hit with a hammer, stepped on). Damaged battery packs should be returned to service for recycling.
WARNING: Fire hazard. Do not store or carry battery so
that metal objects can contact exposed battery terminals.
For example, do not place battery in aprons, pockets, tool boxes, product kit boxes, drawers, etc., with loose nails, screws, keys, etc.
Transporting batteries can possibly cause fi res if the battery terminals inadvertently come in contact with conductive materials such as keys, coins, hand tools and the like. The US
Department of Transportation Hazardous Material Regulations (HMR) actually prohibit transporting batteries in commerce or on airplanes (i.e., packed in suitcases and carry-on luggage) UNLESS they are properly protected from short circuits. So when transporting individual batteries, make sure that the battery terminals are protected and well insulated from materials that could contact them and cause a short circuit.
SPECIFIC SAFETY INSTRUCTIONS FOR LITHIUM ION (Li-Ion)
Do not incinerate the battery pack even if it is severely
damaged or is completely worn out. The battery pack can
explode in a fi re. Toxic fumes and materials are created when lithium ion battery packs are burned.
If battery contents come into contact with the skin, immediately wash area with mild soap and water. If battery liquid gets into the eye, rinse water over the open eye for 15 minutes or until irritation ceases. If medical attention is needed, the battery electrolyte is composed of a mixture of liquid organic carbonates and lithium salts.
Contents of opened battery cells may cause respiratory irritation. Provide fresh air. If symptoms persists, seek medical attention.
WARNING: Burn hazard. Battery liquid may be fl ammable if
exposed to spark or fl ame.
The RBRC™ Seal
The RBRC™ (Rechargeable Battery Recycling Corp oration) Seal on the nickel cadmium, nickel metal hydride or lithium ion batteries (or battery packs) indicate that the costs to recycle these batteries (or battery packs) at the end of their useful life have already been paid by D
EWALT.
In some areas, it is illegal to place spent nickel cadmium, nickel metal hydride or lithium ion batteries in the trash or municipal solid waste stream and the RBRC program provides an environmentally conscious alternative. RBRC™ in cooperation with D
EWALT and other battery users, has
established programs in the United States and Canada to facilitate the collection of spent nickel cadmium, nickel metal hydride or lithium ion batteries. Help protect our environment and conserve natural resources by returning the spent nickel cadmium, nickel metal hydride or lithium ion batteries to an authorized D
EWALT service center or to your local
retailer for recycling. You may also contact your local recycling center for information on where to drop off the spent battery. RBRC™ is a registered trademark of the Rechargeable Battery
Recycling Corporation.
6
English
Important Safety Instructions for All Battery Chargers
SAVE THESE INSTRUCTIONS: This manual contains important safety and operating instruc tions for battery chargers.
• Before using charger, read all instructions and cautionary markings on charger, battery pack, and product using battery pack.
WARNING: Shock hazard. Do not allow any liquid to get inside
charger. Electric shock may result.
CAUTION: Burn hazard. To reduce the risk of injury, charge only
D
EWALT rechargeable batteries. Other types of batteries may burst
causing personal injury and damage. NOTICE: Under certain conditions, with the charger plugged in to the power supply, the charger can be shorted by foreign material. Foreign materials of a conductive nature such as, but not limited to, grinding dust, metal chips, steel wool, aluminum foil, or any buildup of metallic particles should be kept away from charger cavities. Always unplug the charger from the power supply when there is no battery pack in the cavity. Unplug charger before attempting to clean.
WARNING:
DO NOT attempt to charge the battery pack with any chargers other than the ones in this manual. The charger and
battery pack are specifi cally designed to work together.
These chargers are not intended for any uses other than
charging D
EWALT rechargeable batteries. Any other uses may
result in risk of fi re, electric shock or electrocution.
Do not expose charger to rain or snow.
Pull by plug rather than cord when disconnecting charger. This will reduce risk of damage to electric plug and cord.
Make sure that cord is located so that it will not be stepped
on, tripped over, or otherwise subjected to damage or stress.
Do not use an extension cord unless it is absolutely necessary. Use of improper extension cord could result in risk of
fi re, electric shock, or electrocution.
When operating a charger outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
An extension cord must have adequate wire size (AWG or American Wire Gauge) for safety. The smaller the gauge number of the wire, the greater the capacity of the cable, that is 16 gauge has more capacity than 18 gauge. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. When using more than one extension to make up the total length, be sure each individual extension contains at least the minimum wire size. The following table shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
Minimum Gauge for Cord Sets
Ampere Rating
Volts Total Length of Cord in Feet (meters) 120V 25 (7.6) 50 (15.2) 100 (30.5) 150 (45.7)
240V 50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4) More Than
Not More
Than
AWG
0 6 18 16 16 14
610 18 16 14 12 10 12 16 16 14 12 12 16 14 12 Not Recommended
Do not place any object on top of charger or place the charger on a soft surface that might block the ventilation slots and result in excessive internal heat. Place the charger
in a position away from any heat source. The charger is ventilated through slots in the top and the bottom of the housing.
Do not operate charger with damaged cord or plug.
7
English
Do not operate charger if it has received a sharp blow, been dropped, or otherwise damaged in any way. Take it to an
authorized service center.
Do not disassemble charger; take it to an authorized service center when service or repair is required. Incorrect reassembly may result in a risk of electric shock, electrocution or fi re.
Disconnect the charger from the outlet before attempting any cleaning. This will reduce the risk of electric shock. Removing the battery pack will not reduce this risk.
NEVER attempt to connect two chargers together.
The charger is designed to operate on standard 120 V
household electrical power. Do not attempt to use it on any other voltage. This does not apply to the vehicular charger.
Chargers
Your tool uses a DEWALT charger. Be sure to read all safety instructions before using your charger. Consult the chart on the back cover of this manual for compatibility of chargers and battery packs.
Charging Procedure (Fig. 1)
1. Plug the charger into an
A
FIG. 1
appropriate outlet before inserting battery pack.
2. Insert the battery pack
(A) into the charger, as shown in Figure 1, making sure the pack is fully seated in charger. The red (charging) light will blink continuously indicating that the charging process has started.
3. The completion of charge will be indicated by the red light remaining ON continuously. The pack is fully charged and may be used at this time or left in the charger.
Indicator Light Operation
DCB106
PACK CHARGING
PACK CHARGED
DCB107, DCB112
PACK CHARGING
PACK CHARGED
HOT/COLD DELAY
Charge Indicators
HOT/COLD PACK DELAY DCB107, DCB112
The DCB107 and DCB112 chargers have a hot/cold delay feature. When the charger detects a battery that is hot, it automatically delays charging until the battery has cooled. When the charger detects a battery that is cold, it automatically delays charging until the battery has warmed. The red light will continue to blink, but a yellow indicator light will be illuminated during this operation. Once the battery has cooled, the yellow light will turn off and the charger will resume the charging procedure.
8
English
LEAVING THE BATTERY PACK IN THE CHARGER
The charger and battery pack can be left connected with the charge indicator showing Pack Charged.
WEAK BATTERY PACKS: Weak batteries will continue to function but should not be expected to perform as much work.
FAULTY BATTERY PACKS: This charger will not charge a faulty battery pack. The charger will indicate faulty battery pack by refusing to light or by displaying problem pack or charger. NOTE: This could also mean a problem with a charger.
Wall Mounting
DCB107, DCB112
These chargers are designed to be wall mountable or to sit upright on a table or work surface. If wall mounting, locate the charger within reach of an electrical outlet. Mount the charger securely using drywall screws at least 1" (25.4 mm) long, screwed into wood to an optimal depth leaving approximately 7/32" (5.5 mm) of the screw exposed.
Important Charging Notes
1. Longest life and best performance can be obtained if the battery pack is charged when the air temperature is between 65 °F and 75 °F (18–24 °C). DO NOT charge the battery pack in an air temperature below +40 °F (+4.5 °C), or above +105 °F (+40.5 °C). This is important and will prevent serious damage to the battery pack.
2. The charger and battery pack may become warm to touch while charging. This is a normal condition, and does not indicate a problem. To facilitate the cooling of the battery pack after use, avoid placing the charger or battery pack in a warm environment such as in a metal shed, or an uninsulated trailer.
3. If the battery pack does not charge properly: a. Check operation of receptacle by plugging in a lamp or other
appliance;
b. Check to see if receptacle is connected to a light switch which
turns power off when you turn out the lights;
c. Move charger and battery pack to a location where the
surrounding air temperature is approximately 65 °F–75 °F (18–24 °C);
d. If charging problems persist, take the tool, battery pack and
charger to your local service center.
4. The battery pack should be recharged when it fails to produce suffi cient power on jobs which were easily done previously. DO NOT CONTINUE to use under these conditions. Follow the charging procedure. You may also charge a partially used pack whenever you desire with no adverse affect on the battery pack.
5. Foreign materials of a conductive nature such as, but not limited to, grinding dust, metal chips, steel wool, aluminum foil, or any buildup of metallic particles should be kept away from charger cavities. Always unplug the charger from the power supply when there is no battery pack in the cavity. Unplug charger before attempting to clean.
6. Do not freeze or immerse charger in water or any other liquid.
WARNING: Shock hazard. Don’t allow any liquid to get inside
charger. Electric shock may result.
CAUTION: Never attempt to open the battery pack for any reason.
If the plastic housing of the battery pack breaks or cracks, return to a service center for recycling.
Storage Recommendations
1. The best storage place is one that is cool and dry away from direct sunlight and excess heat or cold.
9
English
2. For long storage, it is recommended to store a fully charged battery pack in a cool dry place out of the charger for optimal results.
NOTE: Battery packs should not be stored completely depleted of charge. The battery pack will need to be recharged before use.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
COMPONENTS (Fig. 2)
WARNING: Never modify the hand-held wall scanner or any part of
it. Damage or personal injury could result.
FIG. 2
B
A
C
D
F
E
K
H
I
G
J
N
A. 12V Max* Lithium-ion battery pack B. Handle C. Wheels D. Sensor area E. Center alignment line F. Display
G.
Power on/off button
H.
Left/up arrow button
I.
OK button
J.
Right/down arrow button
K.
Main menu button
INTENDED USE
The hand-held wall scanner is designed to help locate embedded materials behind a wall surface. It can be used on surfaces including drywall, plywood, OSB, ceramic tile, and concrete. Embedded materials detected include wood, ferrous metal, non­ferrous metal, plastic, and live electric (unshielded). The hand-held wall scanner is intended for indoor use only. Please read the entire manual before using the hand-held wall scanner. The hand-held wall scanner is a professional tool. DO NOT let children come into contact with the tool. Supervision is required when inexperienced operators use this tool.
10
English
Belt Hook (Fig.3) (Optional Accessory)
WARNING: To reduce the risk of serious
M
L
FIG. 3
personal injury, DO NOT suspend tool overhead or suspend objects from the belt hook. ONLY hang tool’s belt hook from a work belt.
WARNING: To reduce the risk of serious personal injury, ensure the screw (L) holding the belt hook is secure.
IMPORTANT: When attaching or removing the belt hook, use only the screw (L) that is provided. The belt hook (M) can be attached to either side of the tool using only the screw (L) provided, to accommodate left- or right-handed users. If the hook is not desired at all, it can be removed from the tool. To move the belt hook, remove the screw (L) that holds the belt hook in place, then reassemble on the opposite side.
OPERATION Installing and Removing the Battery Pack
(Fig.4)
NOTE: Make sure your battery pack is fully charged.
N
FIG. 4
A
To install the battery pack (A) into the tool handle, align the battery with the rails inside the tool’s handle and slide it into the handle until the battery pack is fi rmly seated in the tool and ensure that it does not disengage.
To remove the battery pack from the tool, press the release button (N) and fi rmly pull the battery pack out of the tool handle. Insert it into the charger as described in the charger section of this manual.
Getting Started (Fig. 2)
POWER ON/OFF
1. To turn on the hand-held wall scanner, press the power on/off
button (G) and hold for 0.5 seconds. Ensure that the unit is at
least 6" (150 mm) away from the wall when powering on and that the back surface is clear of hands or objects.
2. To turn off the hand-held wall scanner, press the power on/off button (G) and hold for 2 seconds.
The hand-held wall scanner will also power off automatically after 15minutes of inactivity.
INITIAL SETUP
Press the power button (G) to turn on the hand-held wall scanner. The fi rst time the hand-held wall scanner is powered on, it will prompt to select a language and construction type.
1. Press the right/down arrow button (J) or left/up arrow button (H) to highlight English, Spanish or French.
11
English
2. Press the OK button (I) to confi rm selection.
3. Press the right/down arrow button (J) or left/up arrow button (H) to highlight the Construction Type. Options include Residential/Wood Stud, Commercial/Steel Stud, or Concrete.
4. Press the OK button (I) to confi rm selection. The language and construction type will be saved. These setting can later be changed from the menu. See the Menu Options section of this manual for more information.
5. To initialize the hand-held wall scanner, ensure that the unit is off of the wall surface and that there is nothing such as a hand or other object on the back surface. Press the OK button (I) to complete the initialization process.
BASIC OPERATION
The hand-held wall scanner identifi es embedded materials behind a wall surface in two steps. During the fi rst pass over the wall surface, the pre-scan data mapping occurs. The hand-held wall scanner will automatically sense and calibrate for all embedded materials below the wall surface. When the direction of scan is reversed, the hand-held wall scanner will display the embedded materials identifi ed.
Step 1. Place unit on wall.
Pre-Scan Mapping: Move in a straight line across wall surface.
Step 2. Reverse scan direction
to display identifi ed embedded materials.
The hand-held wall scanner can analyze between a 1foot to 9.8foot (0.3m to 3 m) section of wall. The pre-scan data mapping process can begin in any direction. The hand-held wall scanner will automatically change to displaying embedded materials when the initial scan direction is reversed. The hand-held wall scanner can be used either horizontally or vertically.
12
English
SCANNING PROCESS
1. The screen below will indicate that the hand-held wall scanner is ready to start a new scan.
2. Place the hand-held wall scanner on the wall to start a new scan.
3. Move the hand-held wall scanner along the wall surface in a straight line. The screen below will appear indicating the pre-scan data mapping is in process.
4. The hand-held wall scanner has a scannable range of 9.8 feet (3meters) of wall section. The yellow memory bar will fi ll, indicating how much of the available range is used. As the distance limit is approached, the memory bar will turn red.
5. Reverse scanning direction to read the mapped data. The main viewing screen below will appear.
Ensure that the wheels are in contact with the wall surface during the entire pre-scan data mapping and scanning passes.
13
English
The hand-held wall scanner can also detect the presence of a metallic item (such as a drywall screw or nail plate) in a wood stud when Residential/Wood Stud is selected as the Construction Type. When a metallic item is detected in a wood stud, it will be indicated as below:
Scan at several heights to locate the metallic item.
NOTE: The metal sensing is located at the bottom of the unit. Live Electric Indication
When the hand-held wall scanner is in the vicinity of live electric, the lightning icon will blink. NOTE: If a power line is not live or shielded in metal conduit, it will not be detected as live electric. The hand-held wall scanner may detect the metal or plastic of the wire.
Construction Type
The appropriate construction type for each application can be selected in the menu. Options include: Residential/Wood Stud, Commercial/ Steel Stud, or Concrete. Selecting the construction type that most
MAIN VIEWING SCREEN
The main viewing screen contains several sections of information.
P
Q
R
O
S
O. Main Scanning Window P. Live Electric Indication Q. Construction Type R. Battery Fuel Gauge S. Tracking Bar
Main Scanning Window
The main scanning window (O) will give a graphical representation of the embedded material identifi ed below the wall surface. Embedded materials identifi ed include wood, ferrous metal, non­ferrous metal, and plastic.
14
English
accurately matches the application will help improve accuracy of detecting embedded materials.
Battery Fuel Gauge
The display on the hand-held wall scanner includes a battery fuel gauge (R) which consists of four yellow segments that indicate the level of charge remaining in the 12V Max* battery pack. When the level of charge in the battery is below the usable limit, the last segment of the battery fuel gauge will turn red to indicate that the battery will need to be recharged. NOTE: The battery fuel gauge is only an indication of the charge left on the battery pack. It does not indicate product functionality and is subject to variation based on product components, temperature and end-user application.
Tracking Bar
The tracking bar (S) at the bottom of the main viewing screen gives a macro overview of the number of embedded materials located during the pre-scan data mapping process. The current position of the hand-held wall scanner is indicated by the brackets and shaded area.
When the brackets reach the far left or right of the tracking bar, this indicates the end of the data mapped during the pre-scan process. At this point, the main scanning window (O) will also become dark.
The tracking bar can be helpful in indicating which way to move the hand-held wall scanner to identify additional embedded materials behind the wall surface.
Error Messages
SCANNING TOO FAST
If the scanning speed exceeds the maximum processing speed of the hand-held wall scanner, the below error message will appear:
Remove the hand-held wall scanner from the wall. When the "Begin Scanning" screen appears on the display, place the hand-held wall scanner on the wall to restart the scan.
15
English
SCANNING TOO SLOW
If the scanning speed is below the minimum processing speed of the hand-held wall scanner, the following error message will appear:
Remove the hand-held wall scanner from the wall. When the "Begin Scanning" screen appears on the display, place the hand-held wall scanner on the wall to restart the scan.
BATTERY LOW
If the 12V Max* battery pack is about to run out of charge, the following error message will appear:
Replace or recharge the 12V Max* battery pack.
LOST CONTACT WITH THE WALL SURFACE
If the hand-held wall scanner loses contact with the wall surface, the following error message will appear:
Remove the hand-held wall scanner from the wall. When the "Begin Scanning" screen appears on the display, place the hand-held wall scanner on the wall to restart the scan.
MAXIMUM DISTANCE EXCEEDED
The hand-held wall scanner has a maximum scanning range of 9.8feet (3meters). During pre-scan mapping, if the distance scanned exceeds the maximum distance, the following error message will appear:
Remove the hand-held wall scanner from the wall. When the "Begin Scanning" screen appears on the display, place the hand-held wall scanner on the wall to restart the scan.
16
English
Menu Options (Fig. 2)
Press the menu button (K) to view the menu options. NOTE: At any time, the menu button may be pressed to navigate up one level.
1. Press the right/down arrow button (J) or left/up arrow button (H) to highlight the menu option.
2. Press the OK button (I) to confi rm selection.
CONSTRUCTION TYPE
1. Press the right/down arrow button (J) or left/up arrow button (H) to highlight the Construction Type. Options include Residential/Wood Stud, Commercial/Steel Stud, and Concrete.
2. Press the OK button (I) to confi rm selection.
LANGUAGE SELECTION
1. Press the right/down arrow button (J) or left/up arrow button (H) to highlight English, French or Spanish.
2. Press OK (I) to confi rm selection.
VIEW TUTORIAL
The hand-held wall scanner includes a tutorial with tips for best practices. After completion of the tutorial, the hand-held wall scanner will return to the main menu.
DISPLAY VERSION
The hand-held wall scanner will display the product software version.
Press the OK button (I) to exit.
17
English
RESET FACTORY DEFAULTS NOTICE: Changing to default setup will erase current settings and
restore factory settings.
1. Press the right/down arrow button (J) or left/up arrow button (H) to highlight YES or NO.
2. Press the OK button (I) to confi rm selection.
3. If YES is selected, the hand-held wall scanner will ask for a second confi rmation to restore factory defaults. Ensure that the unit is at least 6" (150 mm) away from the wall and the back surface is clear of hands and objects. Press the right/down arrow button (J) or left/ up arrow button (H) to highlight YES or NO.
4. Press the OK button (I) to confi rm selection.
Operating Tips
• Use only DEWALT 12V Max* lithium-ion battery.
• Ensure the D
EWALT battery is in good working condition. If the
battery fuel gauge (R) on the main viewing screen has only one red segment lit, the battery needs to be recharged.
• Scan both horizontally and vertically to fully map out embedded materials behind the wall surface.
• To locate metal items in wood studs, such as nail plates or drywall screws, scan at several different heights.
• Scan uniformly without lifting from the surface of the wall.
• Always scan SLOWLY to achieve maximum sensitivity.
• Do not touch the surface being scanned with your other hand or any other part of the body as it could interfere with scanning.
• Refer to construction plans, visible exits of wires and pipes and construction techniques. Studs are normally spaced either 16" (40cm) or 24" (60 cm) apart and are 1-1/2" (38mm) wide. Doors and windows are often constructed with studs and headers which are closer together.
• Avoid scanning through wall surfaces which have inconsistent density such as carpet with padding, excessively thick plaster and lath, freshly painted walls or metallic wall coverings.
• Avoid wearing jewelry such as rings or watches. The metal may cause inaccurate detection.
• Protect against moisture and direct sunlight.
• Do not place stickers, decals, paint or name plates, especially metal ones, on the sensor area of the back of the tool.
18
English
MAINTENANCE Cleaning
WARNING: Blow dirt and dust off with clean, dry air at least once
a week. To minimize the risk of eye injury, always wear ANSI Z87.1 approved eye protection when performing this.
WARNING: Never use solvents or other harsh chemicals for
cleaning the non-metallic parts of the tool. These chemicals may weaken the plastic materials used in these parts. Use a cloth dampened only with water and mild soap. Never let any liquid get inside the tool; never immerse any part of the tool into a liquid.
CHARGER CLEANING INSTRUCTIONS
WARNING: Shock hazard. Disconnect the charger from the AC
outlet before cleaning. Dirt and grease may be removed from the exterior of the charger using a cloth or soft non-metallic brush. Do not use water or any cleaning solutions.
Troubleshooting
SITUATION PROBABLE CAUSE SOLUTION
Unit does not turn on
• No power to unit • Make sure 12V Max* battery pack is fully charged
• Fully seat the 12V Max* battery pack in the handle
Unit does not display embedded materials; says "Pre-Scan Data Mapping"
• Unit is in process of mapping scanned area
• Review the Scanning Process section of the manual
SITUATION PROBABLE CAUSE SOLUTION
Frequently getting "Lost Contact" error
• Need to re-initialize • Remove unit from the wall. When the "Begin Scanning" screen appears, press the OK button (I). Ensure that the unit is off of the wall surface and that there is nothing such as a hand or other object on the back surface. Press the OK button (I) to complete the initialization process.
No embedded materials detected or diffi culty in detecting embedded materials
• Too narrow of area
mapped
• Diffi culty in scanning
below special wall condition
• Re-map larger area
• Scan slowly
• Scan in a straight line
• Review the Detection
through Special Surface Conditions section of the
manual
• Scan in both the horizontal and vertical directions
• Ensure that the unit is at least 6" (150mm) away from the wall when powering on
Diffi culty in detection of metal
• Metal items too deep
• Scan in both horizontal and vertical straight lines. Metal sensitivity is increased when the metal object is parallel to the sensor. NOTE: The metal sensing is located at the bottom of the unit.
19
English
SITUATION PROBABLE CAUSE SOLUTION
Seemingly false metal detection
• Metal items such as jewelry are too close to sensor area
• Remove jewelry & re-scan
Diffi culty in scanning near door or windows
• Double or triple studs are common around doors and windows
• Detect outer edge instead
Area of voltage detected is larger than anticipated
• Static charge may be present on the wall surface
• Scan a smaller area
• Turn off the electrical circuit and identify metal wire instead
• Place your free hand on the wall to drain static
Electrical voltage not detected in area where it was thought to be
• Wires are shielded by metal conduit
• Wires are deeper than 3" (76mm)
• Wires are not live
• Cannot scan below special wall condition
• Review identifi ed metal in scanning window to determine metal conduit
• Plug an item into a wall outlet to verify live circuit
• Review the Detection
through Special Surface Conditions section of the
manual
Unexpected materials detected
• Materials or items on other side of wall
• Inspect other side of wall and remove any items from wall surface
• Check that the construction type selected most accurately matches the application
SITUATION PROBABLE CAUSE SOLUTION
Received error message: Too fast
• Scanning too fast • Scan slowly
Received error message: Lost surface contact
• Hand-held wall scanner lifted off wall surface
• Re-map area and repeat scanning
Cannot get a center line to appear
• Wall is thick or dense
• Review the Detection
through Special Surface Conditions section of the
manual
Screen freezes or won't turn on
• Software lockup • Insert a small object (i.e.,
paper clip end) into the reset button. The reset button is located on the back surface, under the label. There is a circle on the label indicating the reset location.
Accessories
WARNING: Since accessories, other than those offered by
D
EWALT, have not been tested with this product, use of such
accessories with this tool could be hazardous. To reduce the risk of injury, only D
EWALT recommended accessories should be used with
this product.
Recommended accessories for use with your tool are available at extra cost from your local dealer or authorized service center. If you need assistance in locating any accessory, please contact D
EWALT
Industrial Tool Co., 701 East Joppa Road, Towson, MD 21286, call 1-800-4-D
EWALT (1-800-433-9258) or visit our website: www.dewalt.
com.
20
English
RECOMMENDED ACCESSORIES
Please contact D
EWALT Industrial Tool Co., 701 East Joppa Road,
Towson, MD 21286, call 1-800-4-D
EWALT (1-800-433-9258) or visit
our website www.dewalt.com.
Repairs
The charger, battery pack and hand-held wall scanner are not serviceable. There are no serviceable parts inside the charger, battery pack or hand-held wall scanner.
To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment (including brush inspection and replacement) should be performed by a D
EWALT factory service center, a DEWALT authorized
service center or other qualifi ed service personnel. Always use identical replacement parts.
SPECIFICATIONS
Power Source DEWALT 12V Max* Lithium-ion
battery
Run-Time Approximately 4 hours Battery Charge Indicator Yes Temperature Range (Operating) 23°F to 113°F (-5°C to 45°C) Temperature Range (Storage) -25°F to 122°F (-32°C to 50°C)
Scans Through Drywall, plywood, OSB,
ceramic tile, and concrete
Detects Embedded Materials Wood, ferrous metal, non-
ferrous metal, plastic, and live electric (unshielded)
Maximum Wood Sensing Depth 1.5" (38mm) Maximum Non-Ferrous Metal Sensing Depth 3" (76mm) Maximum Ferrous Metal Sensing Depth 3" (76mm)
Maximum Plastic Sensing Depth 3" (76mm) Maximum Live Electric Sensing Depth 3" (76mm) Minimum Assumed Spacing Between
Embedded Materials
4" (102 mm)
Position Accuracy 1/2" (13mm) Display Type 3.5" (88.9mm) Color LCD Display Resolution 320x240 pixels Language Selection English, Spanish, French
Register Online
Thank you for your purchase. Register your product now for:
WARRANTY SERVICE: Registering your product will help you
obtain more effi cient warranty service in case there is a problem with your product.
CONFIRMATION OF OWNERSHIP: In case of an insurance loss,
such as fi re, fl ood or theft, your registration of ownership will serve as your proof of purchase.
FOR YOUR SAFETY: Registering your product will allow us to
contact you in the unlikely event a safety notifi cation is required under the Federal Consumer Safety Act.
Register online at www.dewalt.com/register.
Three Year Limited Warranty
DEWALT will repair, without charge, any defects due to faulty materials or workmanship for three years from the date of purchase. This warranty does not cover part failure due to normal wear or tool abuse. For further detail of warranty coverage and warranty repair information, visit www. dewalt.com or call 1-800-4-D
EWALT (1-800-433-9258). This warranty
does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specifi c
21
English
legal rights and you may have other rights which vary in certain states or provinces.
In addition to the warranty, D
EWALT tools are covered by our:
1 YEAR FREE SERVICE
D
EWALT will maintain the tool and replace worn parts caused by
normal use, for free, any time during the fi rst year after purchase.
2 YEARS FREE SERVICE ON D
EWALT BATTERY PACKS
DC9071, DC9091, DC9096, DC9280, DC9360, DC9180,
DCB120, DCB127, DCB201, DCB203 and DCB207
3 YEARS FREE SERVICE ON D
EWALT BATTERY PACKS
DCB200, DCB204, DCB205
D
EWALT BATTERY PACKS
Product warranty voided if the battery pack is tampered with in any way. D
EWALT is not responsible for any injury caused by tampering and
may prosecute warranty fraud to the fullest extent permitted by law.
90 DAY MONEY BACK GUARANTEE
If you are not completely satisfi ed with the performance of your DEWALT Power Tool, Laser, or Nailer for any reason, you can return it within 90 days from the date of purchase with a receipt for a full refund – no questions asked. LATIN AMERICA: This warranty does not apply to products sold in Latin America. For products sold in Latin America, see country specifi c warranty information contained in the packaging, call the local company or see website for warranty information.
FREE WARNING LABEL REPLACEMENT: If your warning labels become illegible or are missing, call 1-800-4-D
EWALT (1-800-433-
9258) for a free replacement.
Loading...