OOppeerraattiioonn MMaannuuaall
CC11220000 DDVVBB--CC MMeetteerr
VVeerr::11..1111

WARRANTY
We provide a 12-month warranty against any defect in
materials and workmanship from the date of shipment.
This warranty is not transferable and not applicable to
the used or demonstration products. The obligation of
us arising from a warranty claim shall be limited to
repairing, or as an option, replacing without charge,
any assembly or component (except batteries and
chargers).
We shall have no responsibility for any defect or
damage caused by improper use, improper
maintenance or for any product which has been
repaired or altered by anyone other than us or an
authorized representative.
© Deviser Electronics Instrument Co., Ltd.
Deviser Part No.: C1200-DL
All rights reserved.
Printed in CHINA, January 2015.

INDEX
1. General Introduction ...................................... 1
2. Panel Introduction ......................................... 2
2.1 Appearance .......................................... 2
2.2 Keypad................................................. 3
2.3 Display Description ............................. 4
3. Power Supply ................................................ 5
3.1 Battery ................................................. 5
3.2 Charging .............................................. 6
4. Using the Instrument ..................................... 7
4.1 Level Test ............................................ 7
4.2 Tilt ....................................................... 8
4.3 Channel Scanning ................................ 9
4.4 C/N .................................................... 10
4.5 Trunk Voltage .................................... 10
4.6 Setup .................................................. 11
5. User Channel Plan ....................................... 20
5.1 Upload and Download Channel Plan. 20
6. Specification ................................................ 20
7. Accessories .................................................. 22


C1200 DVB-C Meter Operation Manual
1. General Introduction
C1200 DVB-C Meter is specially designed for
installation and field technicians seeking to quickly
ensure the quality of digital and analog cable services.
With Streamlined appearance design and simple user
interface, C1200 offers the most cost effective choice
for a variety of applications. The digital measurements
include, modulation error ratio (MER), and pre- and
post-FEC bit error rate (BER).It also possesses the
features expected in a good SLM including analog
channel video level, video-to-audio level, full scan, and
tilt etc.
This palm sized meter with only 350g weight allows the
filed technicians to work for 4 hours continuously.

C1200 DVB-C Meter Operation Manual
2. Panel Introduction
2.1 Appearance
Selection
USB Port
2-1

C1200 DVB-C Meter Operation Manual
2.2 Keypad
2-2
、 :Increase and decrease.
、 :Left and right circularly selection.
:Power on/off(hold it over 3 seconds to power off)
or Confirmation.
:Main Menu.
:Return to previous menu or cancel.
:Charger Indicator

C1200 DVB-C Meter Operation Manual
2.3 Display Description
Figure 2-3
Mode
Lock
Channel Name : The Frequency, Power Level,
MER and BER are displayed on the same screen.
Battery:Capacity of battery.

C1200 DVB-C Meter Operation Manual
3. Power Supply
3.1 Battery
With a built-in 7.4V /1.6AH Lithium battery, the
meter can continuously work for above 4 hours.
When the battery voltage drops below 6.0V,
C1200 will automatically power off and then
users must charge it with the attached charger
for about 3 hours.
NOTE:
1. Only use the charger provided with the meter.
2. Power off the meter when charging.
3.Lower temperature may cause the battery capacity
reduction, but does not damage the battery.
4. Replace a new battery when the battery working
time reduce.

C1200 DVB-C Meter Operation Manual
3.2 Charging
Charge the meter before the first time use. Please charge
the meter as follows:
1. Insert the charger output plug into C1200 DC charge
socket.
2. Connect the charger to AC 100V-240V Power and the
charger indicator of meter is with red light.
3. When indicator switch to green, the instrument has
been fully charged(It is suggested to charge extra one
hour after indicator switched to green, which will be
helpful to extend the battery life). Then you can
disconnect the power and pull out the charger output
plug.
NOTE: Only charge in the temperature 10℃~35℃.

C1200 DVB-C Meter Operation Manual
4. Using the Instrument
Power on C1200, as Figure 4-1.
Figure 4-1
These icons are listed in C1200 Main Interface: LEVEL,
TILT, SCAN, C/N and SETUP. Press”Left and Right”
to select the functions, press “ENTER” to enter the
function
4.1 Level Test
C1200 can measure both analog and digital
signal, as Figure 4-1-1Analog Signal
Measurement Interface and Figure 4-1-2 Digital
Signal Measurement Interface.

C1200 DVB-C Meter Operation Manual
Figure 4-1-1 Analog Signal Measurement
-BER/POST-BER
Figure 4-1-2 Digital Signal Measurement Interface
Press “Up and Down” to select CH,press “Left and
Right” to edit the Channel parameters.
4.2 Tilt
Tilt/Level list test is the effective solution to check the
flatness and splitter’s attenuation of cable system,
C1200 can get levels of 8 channels and observe the
measurement result and graph easily.

C1200 DVB-C Meter Operation Manual
Figure 4-2-1 Tilt
Figure 4-2-2 SETUP-T I LT
4.3 Channel Scanning
Figure 4-3 Channel Scanning
C1200 support channel scanning function in order to
test the flatness and amplitude of cable TV system
quickly.

C1200 DVB-C Meter Operation Manual
4.4 C/N
Figure 4-4 C/N
Press “Up and Down” to select CH,press “Left and
Right” to edit the Channel parameters.
4.5 Trunk Voltage
As Figure 4-5, you can get the Trunk Voltage in this
interface.
Figure 4-5

C1200 DVB-C Meter Operation Manual
4.6 Setup
Press to select “SETUP” in the main menu. Press to
setup interface as Figure 4-6.
Figure 4-6
4.6.1 System Information
The information of the instrument, Refer to Figure 4-6-1
It includes serial number, software version, hardware
version and so on.
Figure 4-6-1

C1200 DVB-C Meter Operation Manual
4.6.2 General
Press to select “Configure” in the figure 11 interface,
then press to setup interface, as figure 4-6-2.
Figure 4-6-2
1. Backlight
Set the backlight ON and OFF by pressing
, refer to Figure 4-6-3.
Figure 4-6-3
2. Shutdown Time
Set shutdown time for inactive keypad after 5 minutes,
15 minutes, 30minutes by pressing
or
or .

C1200 DVB-C Meter Operation Manual
Refer to figure 4-6-4.
Figure 4-6-4
3. Level Units
Set level unit dB
buttons. Refer to figure 4-6-5.
or
μV, dBmV or dBm by pressing
Figure 4-6-5

C1200 DVB-C Meter Operation Manual
4. LCD Contrast
As figure 4-6-6. Press or to adjust the
contrast .
4.6.3 Channel Plan Setup
A default Channel Plan is programmed in C1200 when
delivery. You can modify the Channel Plan parameters
in this interface. As Figure 4-6-7:
In the same time,you can also modify and edit the
Channel Plan through Toolbox software on PC,and up
Figure 4-6-6
Figure 4-6-7

C1200 DVB-C Meter Operation Manual
load the Channel Plan to C1200,or press “ENTER” to
edit the selected plan by hand.
In DIG channel press
STANDARD、FREQ、SR、BW、TYPE, press
enter into parameters edition and press
to STATUS 、TYPE 、
to
or
to input parameters.As Figure 4-6-8、Figure 4-6-9、
Figure 4-6-10:
Figure 4-6-8
Figure 4-6-9

C1200 DVB-C Meter Operation Manual
Figure 4-6-10
In ANA channel press to STATUS 、TYPE、
FREQ、OFFSET, press
edition and press
to enter into parameters
or to input parameters.
As Figure 4-6-11、Figure 4-6-12:
Figure 4-6-11

C1200 DVB-C Meter Operation Manual
Figure 4-6-12
4.6.4 LIMIT Setup
As Figure 4-6-13, you can press to VIDEO 、
VA 、 POWER 、 MER , press
parameters edition and press
parameters.
to enter into
or to input
Figure 4-6-13

C1200 DVB-C Meter Operation Manual
4.6.5 Battery State
The battery voltage is shown as a column graph as
Figure 4-6-14. When the voltage is lower than 0%,the
instrument will automatically power off.
Figure 4-6-14
4.6.5 Operation Mode
As Figure 4-6-15, you can set up the operation mode of
C1200 in this interface.
Figure 4-6-15
As Figure 4-6-16,C1200 provides 5 kinds of operation
mode for choice: 30s, 1min, 5min, 10min, ON. You can
set the mode by pressing
or and . If you

C1200 DVB-C Meter Operation Manual
prefer to measure continuously,please choose
“ON”,while if you only want to measure
occasionally,please choose the other 4 modes with the
proper measurement time you want,and these modes can
consume less power.
Figure 4-6-16

C1200 DVB-C Meter Operation Manual
Channel Scan,Tilt,Trunk Voltage
5. User Channel Plan
5.1 Upload and Download Channel Plan
The instrument can be connected with PC by USB cable
to upload and download channel plan.
6. Specification
Analog CATV
Frequency Range 5~1200MHz
Level
Accuracy
RBW
C/N
C/N Accuracy
Others
DVB-C
Frequency Range
Power Level
μV
2.0dB
3.0dB
200MHz
μV

C1200 DVB-C Meter Operation Manual
16/32/64/128/256QAM
(J.83A/C)
64/256QAM(J.83B)
2.0dB
MER
MER Accuracy
BER
Modulation Type
SR
Interface
RF Input
AC Adapter
USB
Battery
Capacity
Working Time
Charging Time
Other Specification
Dimension
Weight
2.0dB
-3~1E-9
Ω Typ e -F(f)
-USB
×93×42mm

C1200 DVB-C Meter Operation Manual
CD(Manual and Toolbox software)
7. Accessories
(PW09021915W) 1
Cable (P.900000421) 1
1
(PKS30004603) 1
(PK1S3000000) 1
-F(f) to Type-(f) adapter(P.121068J8J
1
1

C1200DVB‐CMeterOperationManual
Deviser (China) Deviser (US)
Address: No.8, Haitai Chuangxin 3
Hi-tech Industrial Development Area, Suite 606,San Jose, CA 95131, USA
Tianjin, China, 300392 Tel: +1 408 931 0948
Tel: +86 2764 5003 ext.803 http://www.deviserinstruments.com
http://www.deviserinstruments.com E-mail: sales@deviserinstruments.com
E-mail: overseasbiz@deviser.com.cn
rd
Road, Address: 780 Montague Expressway,