MODEL
HORSE POWER
RATED/SURGE WATTS
VOLTAGE
AMPERAGE
PHASE
HERTZ
ENGINE SPEED
MAX. AMBIENT TEMP.
FUEL CAPACITY
RUN TIME @ 50%/100%
This product is not equipped with a spark arresting muffler. If the product will be used around flammable
•
materials, or on land covered with materials such as agricultural crops, forest, brush, grass, or other similar
items, then an approved spark arrester must be installed and is legally required in the state of California. It is a
violation of California statutes section 130050 and/or sections 4442 and 4443 of the California Public Resources
Code, unless the engine is equipped with a spark arrestor, as defined in section 4442, and maintained in effective
working order. Spark arresters are also required on some U. S. Forest service land and may also be legally
required under other statutes and ordinances.
GBV4600
9
4600/5750
120/240
38.3A/19.2A
SINGLE
60 Hz
3600 RPM
104° F
6 GALLON
13.3/6.5 HR
Engine exhaust from this product contains chemicals known, in certain quantities, to cause cancer, birth defects or
•
other reproductive harm.
MGP-4600 6/13/95
DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615
INSTALLATION OF BATTERY ................................................. 15
In the unlikely event you should have a problem with this
product or if you are missing any parts, it is not necessary to
return it to the store where you purchased it. Simply call our
toll-free number and talk with our Service Representative.
OUR OFFICE HOURS ARE FROM
8:00 a.m. to 4:30 p.m. (CST)
MONDAY THROUGH FRIDAY
CALL TOLL-FREE 1-800-888-2468, EXT. 2
2
LIMITED WARRANTY
ONE YEAR FROM DATE OF PURCHASE
All merchandise manufactured by DeVilbiss Air Power Company is warranted to be free of defects in workmanship
and material which occur during the first year from the date of purchase by the original purchaser (initial user).
Products covered under this warranty include: air compressors, *air tools, accessories, service parts, pressure
washers, and generators used in consumer applications (i.e., personal residential household usage only).
Air compressors, *air tools, accessories, service parts, pressure washers, and generators used in commercial
applications (income producing) are covered by a 90 day warranty.
DeVilbiss Air Power will repair or replace, at DeVilbiss's option, products or components which have failed within the
warranty period. Repair or replacement, and service calls on 60 and 80 gallon air compressors, will be handled by
Authorized Warranty Service Centers and will be scheduled and serviced according to the normal work flow and
business hours at the service center location, and depending on the availability of replacement parts.
All decisions of DeVilbiss Air Power Company with regard to this policy shall be final.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
RESPONSIBILITY OF ORIGINAL PURCHASER (Initial User):
o
Retain original cash register sales receipt as proof of purchase for warranty work.
o
Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s).
o
Deliver or ship the product to the nearest DeVilbiss Air Power Authorized Warranty Service Center.
Freight costs, if any, must be paid by the purchaser.
o
Air compressors with 60 and 80 gallon tanks only will be inspected at the site of installation. Contact the nearest
Authorized Warranty Service Center, that provides on-site service calls, for service call arrangement.
o
If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center, the purchaser
should contact DeVilbiss Air Power Company.
THIS WARRANTY DOES NOT COVER:
o
Merchandise sold as reconditioned, floor models and/or display models. Any damaged or incomplete equipment
sold "as is".
o
Merchandise used as "rental" equipment.
o
Merchandise that has become inoperative because of ordinary wear, misuse, freeze damage, use of improper
chemicals, negligence, accident, improper and/or unauthorized repair or alterations including failure to operate
the product in accordance with the instructions provided in the Owners Manual (s) supplied with the product.
*Air Tools: O-Rings and driver blades are considered ordinary wear parts, therefore, they are warranted for a
period of 45 days from the date of purchase.
o
An air compressor that pumps air more than 50% during a one hour period is considered misuse because
the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is
30 minutes.
o
Merchandise sold by DeVilbiss Air Power which has been manufactured by and identified as the product of
another company. The product manufacturer's warranty will apply.
o
Repair and transportation costs of merchandise determined not to be defective.
o
Cost associated with assembly, required oil, adjustments or other installation and start-up cost.
o
ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM
ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
o
IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
This manual contains information
that is important for you to know
and understand. This information
relates to protecting YOUR
SAFETY and PREVENTING EQUIP-
MENT PROBLEMS. To help you
recognize this information, we
use symbols to the right. Please
read the manual and pay attention to these sections.
IMPORTANT SAFETY INSTUCTIONS
When using this product basic precautions should always be followed
URGENT SAFETY INFORMATION - A HAZARD
THAT WILL CAUSE SERIOUS INJURY OR LOSS
OF LIFE
IMPORTANT SAFETY INFORMATION - A HAZARD
THAT MIGHT CAUSE SERIOUS INJURY OR LOSS
OF LIFE.
Information for preventing damage to
equipment.
Information that you should pay special
attention to.
• SAVE THESE INSTRUCTIONS •
including the following:
RISK OF ELECTROCUTION AND FIRE
HAZARD
Attempting to connect generator directly
to the electrical system of any building
structure.
Inadequate electrical grounding of generator.
Back feeding electricity through a
building’s electrical system to the
outside utility feed lines could endanger repair persons attempting to
restore service.
Attempting to connect to the incoming
utility service could result in electrocution.
Restoration of electrical service while
the generator is connected to the incoming utility could result in a fire or
serious damage if a isolator switch is
not installed.
The failure of one of the generator’s
electrical devices, a broken wire, wet
surfaces, etc. could result in the entire
unit becoming electrically charged.
Contact with electrically charged
surfaces could result in electrocution.
HOW TO PREVENT ITWHAT COULD HAPPEN
To connect to a structures electrical
system in a safe manner and in compliance with local ordinances, it is
necessary to
have an isolator switch installed by a
qualified electrician.
Make sure that the unit is connected
to an appropriate electrical ground,
in accordance with the requirement
of the National Electric Code. See
page 12 for grounding instructions.
4
READ AND UNDERSTAND ALL WARNINGS BEFORE
ATTEMPTING TO OPERATE GENERATOR.
RISK OF ELECTROCUTION AND FIRE (cont’d)
HAZARD
Operation of generator in rain, wet, icy,
or flooded conditons.
Use of worn damaged, undersized or ungrounded extension cords.
Water is an excellent conductor of
electricity! Water which comes in
contact with electricty charged components can transmit electricity to the
frame and other surfaces, resulting in
electrical shock to anyone contacting
them.
Contact with worn or damaged extension
cords could result in electrocution.
Use of undersize extension cords could
result in overheating of the wires or attached items, resulting in fire.
Use of ungrounded cordsets could prevent operation of circuit breakers and result in electrical shock.
HOW TO PREVENT ITWHAT COULD HAPPEN
Operate generator in a clean, dry, well
ventilated area. Make sure hands are
dry before touching unit.
Inspect extension cords before use
and replace with new if required.
Use proper size (wire gauge) cordset
for application see chart on page 12.
Always use electrically grounded
cordset.
Placing generator on or against highly
conductive surface, such as a steel
walkway or metal roof.
Improper connection of items to generator.
Operation of unit when damaged, or
with guards or panels removed.
Accidental leakage of electrical current
could charge conductive surfaces in contact with the generator.
Exceeding the load capacity of the generator by attaching too many items, or
items with very high load ratings to it
could result in overheating of some items
or their attachment wiring resulting in fire
or electrical shock.
Attempting to use the unit when it has
been damaged, or when it is not functioning normally could result in fire or
electrocution.
Removal of guarding could expose
electrically charged components and
result in electrocution.
Place generator on low conductivity
surface such as a concrete slab.
Read the load rating chart and instructions on page 9. Make sure that the
summation of electrical loads for all
attachments does not exceed the
load rating of the generator.
Do not operate generator with mechanical or electrical problem. Have
unit repaired by an Authorized Service Center.
Do not operate generator with protective guarding removed.
5