DeVilbiss FAC125, FA125 User Manual

OWNERS MANUAL FOR
PERMANENTLY LUBRICATED AIR COMPRESSOR
(For Home Use Only)
MODEL NO.
FA125
FAC125
SPECIFICATION CHART
MODEL NO.
Horsepower SCFM @ 40 psig SCFM @ 90 psig Cut-In Cut-Out Bore Stroke Voltage/Hertz/ Phase Minimum Branch Circuit Requirement *Fuse Type Amperage at Max. Load Tank Size
*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses.
FA125
1
3.7
2.7
100 PSI
125 PSI
1 3/4" 1 1/4"
115/60/1
15 AMPS
Quick Acting
10 AMPS
2.5 Gallon
FAC125
100 PSI
125 PSI
1 3/4" 1 1/4"
115/60/1
15 AMPS
Quick Acting
10 AMPS
2.5 Gallon
-----
3.7
2.7
TABLE OF CONTENTS
SAFETY GUIDELINES .......................................................... 1
WARRANTY ........................................................................ 2
WARNING CHART ........................................................... 3-4
GLOSSARY ......................................................................... 5
DUTY CYCLE ....................................................................... 5
STORAGE ............................................................................ 5
DESCRIPTION OF OPERATION ........................................... 6
INSTALLATION AND BREAK-IN
PROCEDURES ................................................................ 6-7
Location of Air Compressor ........................................ 6
Extension Cords .......................................................... 6
Voltage and Circuit Protection .................................... 6
Grounding Instructions ................................................7
Additional Regulators and Controls ............................ 7
Break-In Procedures ................................................... 7
OPERATING PROCEDURES ................................................ 8
TROUBLESHOOTING GUIDE ......................................... 9-10
COMPRESSOR PARTS LIST ............................................ 11
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and understand. This information relates to protecting YOUR
SAFETY and PREVENTING EQUIPMENT PROBLEMS. To
help you recognize this informa­tion, we use the symbols to the right. Please read the manual and pay attention to these sections.
Call our Toll Free Number 1-800-888-2468, Ext 2, then 1, to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs.
When ordering repair parts from your local Authorized Service Center, always give the following information:
• Model number of your compressor
• Part number and description of the item you wish to purchase
MGP-FA125-2A 9/18/99
URGENT SAFETY INFORMATION - A HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE.
IMPORTANT SAFETY INFORMATION - A HAZARD THAT MIGHT CAUSE SERIOUS INJURY OR LOSS OF LIFE.
Information for preventing damage to equipment.
Information that you should pay special attention to.
LIMITED WARRANTY
ONE YEAR FROM DATE OF PURCHASE
All merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user). Products covered under this warranty include: air compressors, *air tools, accessories, service parts, pressure washers, and generators used in consumer applications (i.e., personal residential household usage only).
Air compressors, *air tools, accessories, service parts, pressure washers, and generators used in commercial applications (income producing) are covered by a 90 day warranty.
DeVilbiss Air Power/ExCell Manufacturing will repair or replace, at DeVilbiss/ExCell’s option, products or components which have failed within the warranty period. Repair or replacement, and service calls on 60 and 80 gallon air compressors, will be handled by Authorized Warranty Service Centers and will be scheduled and serviced according to the normal work flow and business hours at the service center location, and depending on the availability of replacement parts.
All decisions of DeVilbiss Air Power Company/ExCell Manufacturing with regard to this policy shall be final.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
RESPONSIBILITY OF ORIGINAL PURCHASER (Initial User):
o
Retain original cash register sales receipt as proof of purchase for warranty work.
o
Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s).
o
Deliver or ship the product to the nearest DeVilbiss Air Power/ExCell Manufacturing Authorized Warranty Service Center. Freight costs, if any, must be paid by the purchaser.
o
Air compressors with 60 and 80 gallon tanks only will be inspected at the site of installation. Contact the nearest Authorized Warranty Service Center, that provides on-site service calls, for service call arrangement.
o
If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center, the purchaser should contact DeVilbiss Air Power Company/ExCell Manufacturing.
THIS WARRANTY DOES NOT COVER:
o
Merchandise sold as reconditioned, floor models and/or display models. Any damaged or incomplete equipment sold "as is".
o
Merchandise used as "rental" equipment.
o
Merchandise that has become inoperative because of ordinary wear, misuse, freeze damage, use of improper chemicals, negligence, accident, improper and/or unauthorized repair or alterations including failure to operate the product in accordance with the instructions provided in the Owners Manual (s) supplied with the product. *Air Tools: O-Rings and driver blades are considered ordinary wear parts, therefore, they are warranted for a period of 45 days from the date of purchase.
o
An air compressor that pumps air more than 50% during a one hour period is considered misuse because the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.
o
Merchandise sold by DeVilbiss Air Power/ExCell Manufacturing which has been manufactured by and identified as the product of another company. The product manufacturer's warranty will apply.
o
Repair and transportation costs of merchandise determined not to be defective.
o
Cost associated with assembly, required oil, adjustments or other installation and start-up cost.
o
ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
o
IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
Form: SP-100-F - 10/28/97
213 Industrial Drive • Jackson, TN 38301-9615
Telephone: 1-800-888-2468 , Ext. 2
FAX: 1-800-888-9036
2 - ENG
IMPORTANT SAFETY INSTRUCTIONS
• SAVE THESE INSTRUCTIONS •
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUC­TIONS BEFORE USING THIS EQUIPMENT.
HAZARD
RISK OF BURSTING
WHAT CAN HAPPEN
AIR TANK
THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT
IN A VIOLENT TANK EXPLOSION:
1. FAILURE TO PROPERLY DRAIN CONDENSED CAUSING RUST AND THINNING OF THE STEEL TANK.
2. MODIFICATIONS OR ATTEMPTED REPAIRS
3. UNAUTHORIZED MODIFICATIONS TO THE
PRESSURE SWITCH, SAFETY VALVE, OR
OTHER COMPONENTS WHICH
ANY
CONTROL TANK PRESSURE.
WATER FROM THE TANK,
TO THE TANK.
ATTACHMENTS & ACCESSORIES
EXCEEDING THE PRESSURE RATING OF AIR TOOLS, SPRAY GUNS, AIR OPERATED ACCES- SORIES, TIRES AND OTHER INFLATABLES CAN CAUSE THEM TO EXPLODE OR FLY APART,
AND COULD RESULT IN SERIOUS INJURY.
HOW TO PREVENT IT
DRAIN TANK DAILY OR AFTER EACH USE.
IF TANK DEVELOPS A LEAK, REPLACE IT IMMEDIATELY WITH A NEW TANK OR NEW COMPRESSOR OUTFIT.
NEVER DRILL INTO, WELD, OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS
ATTACHMENTS.
THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES. NEVER
MAKE ADJUSTMENTS OR PARTS SUBSTI­TUTIONS TO ALTER THE FACTORY SET
OPERATING PRESSURES.
FOLLOW THE EQUIPMENT MANUFACTUR­ERS RECOMMENDATION AND NEVER EXCEED THE MAXIMUM ALLOWABLE PRES­SURE RATING OF ATTACHMENTS. NEVER
USE COMPRESSOR TO INFLATE SMALL LOW-PRESSURE OBJECTS SUCH AS CHILDREN’S TOYS, FOOTBALLS, BASKETBALLS. ETC.
RISK OF
EXPLOSION OR FIRE
RISK OF
ELECTRICAL SHOCK
IT IS NORMAL FOR ELECTRICAL CONTACTS
WITHIN THE MOTOR AND PRESSURE SWITCH
TO SPARK.
IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION.
RESTRICTING ANY OF THE COMPRESSOR VENTILATION OPENINGS WILL CAUSE SERI­OUS OVERHEATING AND COULD CAUSE FIRE.
YOUR AIR COMPRESSOR IS POWERED BY ELECTRICITY. LIKE ANY OTHER ELECTRI- CALLY POWERED DEVICE, IF IT IS NOT USED PROPERLY IT MAY CAUSE ELECTRIC SHOCK.
ALWAYS OPERATE THE COMPRESSOR IN A WELL VENTILATED AREA FREE OF COM-
BUSTIBLE MATERIALS, GASOLINE OR SOL­VENT VAPORS.
IF SPRAYING FLAMMABLE MATERIALS, LO­CATE COMPRESSOR AT LEAST 20 FEET AWAY FROM SPRAY AREA. AN ADDITIONAL
LENGTH OF HOSE MAY BE REQUIRED.
STORE FLAMMABLE MATERIALS IN A SECURE LOCATION AWAY FROM COM­PRESSOR.
NEVER PLACE OBJECTS AGAINST OR ON TOP OF COMPRESSOR. OPERATE COM­PRESSOR IN AN OPEN AREA AT LEAST 12 INCHES AWAY FROM ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE
FLOW OF FRESH AIR TO THE VENTILATION OPENINGS.
NEVER OPERATE THE COMPRESSOR OUT­DOORS WHEN IT IS RAINING OR IN WET CONDITIONS.
NEVER OPERATE COMPRESSOR WITH COVER COMPONENTS REMOVED OR DAM-
AGED.
3 - ENG
CONTINUE NEXT PAGE
*
HAZARD
WHAT CAN HAPPEN
HOW TO PREVENT IT
RISK OF
ELECTRICAL SHOCK
RISK FROM
FLYING OBJECTS
RISK TO BREATHING
REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN RESULT IN SERIOUS INJURY OR DEATH BY ELECTROCUTION.
ELECTRICAL GROUNDING:
PROVIDE ADEQUATE GROUNDING TO THIS PRODUCT COULD RESULT IN SERIOUS INJURY OR DEATH FROM ELECTROCU­TION. SEE GROUNDING INSTRUCTIONS.
COMPRESSED AIR STREAM CAN
THE CAUSE SOFT TISSUE DAMAGE TO EX­POSED SKIN AND CAN PROPEL DIRT, CHIPS, OBJECTS AT PROPERTY DAMAGE OR PERSONAL INJURY.
THE COMPRESSED AIR FROM YOUR COMPRESSOR IS NOT SAFE FOR BREATH- ING! THE AIR STREAM MAY CONTAIN CARBON MONOXIDE, TOXIC VAPORS OR SOLID PARTICLES.
LOOSE PARTICLES AND SMALL
HIGH SPEED, RESULTING IN
FAILURE TO
ANY ELECTRICAL WIRING OR REPAIRS REQUIRE ON THIS PRODUCT SHOULD BE
PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE
WITH NATIONAL AND LOCAL ELECTRICAL CODES.
MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH THE COMPRESSOR IS CONNECTED PROVIDES PROPER ELEC­TRICAL GROUNDING, CORRECT VOLTAGE AND ADEQUATE FUSE PROTECTION.
ALWAYS WEAR ANSI Z87.1 APPROVED SAFETY GLASSES WITH SIDE SHIELDS
WHEN USING THE COMPRESSOR.
NEVER POINT ANY NOZZLE OR SPRAYER TOWARD ANY PART OF THE BODY OR AT OTHER PEOPLE OR ANIMALS.
NEVER INHALE AIR FROM THE COMPRES­SOR EITHER DIRECTLY OR FROM A
BREATHING DEVICE CONNECTED TO THE COMPRESSOR.
RISK FROM
MOVING PARTS
SPRAYED MATERIALS SUCH AS PAINT,
PAINT SOLVENTS, PAINT REMOVER, INSECTICIDES, WEED KILLERS, ETC.. CONTAIN HARMFUL VAPORS AND POI­SONS.
MOVING PARTS CAN CAUSE SERIOUS INJURY OR DAMAGE IF THEY COME INTO
CONTACT WITH YOU OR YOUR CLOTHING.
ATTEMPTING TO OPERATE OR REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND ELECTRICAL SHOCK.
A PORTABLE COMPRESSOR CAN FALL FROM A TABLE, WORKBENCH OR ROOF
CAUSING DAMAGE TO THE COMPRESSOR WHICH COULD EXPOSE YOU TO HAZARD­OUS MOVING OR ELECTRICAL PARTS.
THE COMPRESSOR CYCLES AUTOMATI­CALLY WHEN THE PRESSURE SWITCH IS IN THE ON/AUTO POSITION.
WORK IN AN AREA WITH GOOD CROSS­VENTILATION. READ AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON THE LABEL OR SAFETY DATA SHEETS FOR THE MATERIAL YOU ARE SPRAYING. USE A NIOSH/MSHA APPROVED RESPIRATOR
DESIGNED FOR USE WITH YOUR SPECIFIC APPLICATION.
DO NOT REMOVE THE PROTECTIVE COVERS FROM THIS PRODUCT. NEVER OPERATE THE COMPRESSOR WITH GUARDS OR COVERS WHICH ARE DAM-
AGED OR REMOVED.
ANY REPAIRS REQUIRED ON THIS PROD-
UCT SHOULD BE PERFORMED BY AUTHO­RIZED SERVICE CENTER PERSONNEL.
ALWAYS OPERATE COMPRESSOR IN A STABLE SECURE POSITION TO PREVENT
ACCIDENTAL MOVEMENT OF THE UNIT.
NEVER OPERATE COMPRESSOR ON A ROOF OR OTHER ELEVATED POSITION. USE ADDITIONAL AIR HOSE TO REACH HIGH LOCATIONS.
ALWAYS TURN OFF THE COMPRESSOR, BLEED PRESSURE FROM THE AIR HOSE AND TANK UNPLUG FROM ELECTRICAL OUTLET BEFORE PERFORMING MAINTE­NANCE OR ATTACHING TOOLS AND AC-
CESSORIES.
RISK OF BURNS
CTMCWPS — 5/1/97
TOUCHING EXPOSED METAL SUCH AS THE
COMPRESSOR HEAD OR OUTLET TUBE
CAN RESULT IN SERIOUS BURNS.
4 - ENG
NEVER TOUCH ANY EXPOSED METAL PARTS ON COMPRESSOR DURING OR IMMEDIATELY AFTER OPERATION. COM­PRESSOR WILL REMAIN HOT FOR SEV-
ERAL MINUTES AFTER OPERATION.
GLOSSARY
SCFM or CFM: Standard Cubic Feet per Minute; a unit of measurement of air delivery.
PSIG or PSI: Pounds per square inch gauge.
CUT-IN PRESSURE: While the motor is off, air tank
pressure drops as you continue to use your accessory. When the tank pressure drops to approximately 100 PSI the motor will restart automatically. The low pressure at
DUTY CYCLE
which the motor automatically re-starts is called "cut-in pressure."
CUT-OUT PRESSURE: When you turn on your air com­pressor and it begins to run, air pressure in the air tank begins to build. It builds to approximately 125 PSI before the motor automatically shuts off .The high pressure at which the motor shuts off is called "cut-out pressure."
All DeVilbiss Air Power manufactured air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps air more than
STORAGE
When you have finished using the air compressor:
1. Set the "ON/OFF" switch to "OFF" and unplug the cord.
2. Review the "Operating Procedures" section (page 8). Be sure to drain the water from the air tank.
50% of one hour is considered misuse, because the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 min­utes.
3. Protect the electrical cord and air hose from damage by winding them loosely around the air compressor.
4. Store the air compressor in a clean and dry location.
5 - ENG
DESCRIPTION OF OPERATION
Air Compressor Pump: To compress air, the piston moves up and down in the cylinder. On the downstroke, air is drawn in through the intake valves. The exhaust valves remain closed. On the upstroke of the piston, air is compressed. The intake valves close and compressed air is forced out through the exhaust valves, through the outlet tube, through the check valve and into the air tank. Working air is not available until the compressor has raised the tank pressure above that required at the air outlet.
Check Valve: When the air compressor is operating, the check valve is “open”, allowing compressed air to enter the air tank. When the air compressor reaches “cut-out” pressure, the check valve “closes”, allowing air pressure to remain inside the air tank.
Pressure Switch: The pressure switch automatically starts the motor when the tank pressure drops below the factory set “cut-in” pressure. It stops the motor when the air tank pressure reaches the factory set “cut-out” pressure.
Regulator: The air pressure coming from the air tank is controlled by the regulator. Turn the regulator knob clock­wise to increase pressure and counterclockwise to decrease pressure. To avoid minor readjustment after making a change in pressure setting, always approach the desired pressure from a lower pressure. When reducing from a higher to a lower setting, first reduce to pressure less than that desired, then bring it up to the desired pressure.
Depending on the air requirements of each particular accessory, the outlet regulated air pressure may have to be adjusted while operating the accessory.
Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less or equal to the tank pressure. See “Operat­ing Procedures”.
Tank Pressure Gauge: The tank pressure gauge indi­cates the reserve air pressure in the tank.
Cooling System: This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.
Air Intake Filter: This unit requires no air filter due to the unique design of the air intake system.
Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.
On/Auto-Off Switch: Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use.
INSTALLATION AND BREAK-IN PROCEDURES
Location of the Air Compressor
Your compressor comes to you completely assembled and ready for use. Operate the air compressor in a dry, clean, cool and well ventilated area. The air compressor pump and case are designed to allow for proper cooling. Clean or blow off dust or dirt that collects on the air compressor. A clean air compressor runs cooler and provides longer service. The ventilation openings on your air compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.
Voltage and Circuit Protection
See front cover.
6 - ENG
Extension Cords
Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor.
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade ground­ing plug, and a 3-slot receptacle that will accept the plug on the compressor.
in good condition.
no longer than 50 feet.
14 gauge (AWG) or larger. (Wire size increases as gauge number decreases.) 12 AWG, 10 AWG and 8 AWG may also be used. DO NOT USE 16 OR 18 AWG.
INSTALLATION AND BREAK-IN
PROCEDURES
GROUNDING INSTRUCTIONS
RISK OF ELECTRICAL SHOCK! IN THE EVENT OF A SHORT CIRCUIT, GROUNDING REDUCES THE RISK OF SHOCK BY PROVIDING AN ESCAPE WIRE FOR THE ELECTRIC CURRENT. THIS AIR COMPRESSOR MUST BE PROPERLY GROUNDED.
The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug. The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. The outlet must have the same configuration as the plug. See illustration. DO NOT USE AN ADAPT-
ER.
Inspect the plug and cord before each use. Do not use if there are signs of damage.
IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.
Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outlet should be installed by a qualified electrician.
If repairing or replacing cord or plug, the grounding wire must be kept separate from the current-carrying wires. Never connect the grounding wire to a flat blade plug terminal. The grounding wire has insulation with an outer surface that is green - with or without yellow stripes.
If these grounding instructions are not completely under­stood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.
Additional Regulators and Controls
Since the air tank pressure is usually greater than that which is needed, a regulator is employed to control the air pressure ahead of any individual air driven device.
Separate air transformers which combine the function of air regulation, moisture and dirt removal should be used where applicable.
Break-in Procedures
Serious damage may result if the following break-in instructions are not closely followed.
This procedure is required:
1. Before the air compressor is put into service.
2. When the check valve is replaced.
a. Set the pressure switch lever to the "OFF"
position.
b. Plug the power cord into the correct branch
circuit receptacle.
c. Turn the regulator clockwise, opening it fully, to
prevent air pressure build-up in the tank.
d. Move the pressure switch lever to "ON/AUTO".
The compressor will start.
e. Run the compressor for 15 minutes. Make sure
the regulator is open and there is no tank pressure build-up.
f. After 15 minutes, close the regulator by turning
knob counterclockwise. The air receiver will fill to cut-out pressure and the motor will stop. The compressor is now ready for use.
7 - ENG
OPERATING PROCEDURES
1. Before attaching air hose or accessories, make sure the OFF/AUTO lever is set to “OFF” and the air regulator or shut-off valve is closed.
2. Attach hose and accessories.
TOO MUCH AIR PRESSURE CAUSES A HAZARDOUS RISK OF BURSTING. CHECK THE MANUFACTURER'S MAXIMUM PRES­SURE RATING FOR AIR TOOLS AND ACCESSORIES. THE REGULATOR OUTLET PRESSURE MUST NEVER EXCEED THE MAXIMUM PRESSURE RATING.
3. Turn the OFF/AUTO lever to “AUTO” and allow tank pressure to build. Motor will stop when tank pressure reaches “cut-out” pressure.
4. Open the regulator by turning it clockwise. Adjust the regulator to the correct pressure setting. Your com­pressor is ready for use.
5. Always operate the air compressor in well-ventilated areas; free of gasoline or other solvent vapors. Do not operate the compressor near the spray area.
When you are finished:
6. Set the “OFF/AUTO” lever to “OFF”.
7. Turn the regulator counterclockwise and set the outlet pressure to zero.
8. Remove the air tool or accessory.
9. Open the regulator and allow the air to slowly bleed from the tank. Close the regulator when tank pressure is approximately 20 psi.
10. Drain water from air tank.
WATER WILL CONDENSE IN THE AIR TANK. IF NOT DRAINED, WATER WILL CORRODE AND WEAKEN THE AIR TANK CAUSING A RISK OF AIR TANK RUPTURE.
NOTE
If drain cock valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.
11. After the water has been drained, close the drain cock or drain valve. The air compressor can now be stored.
8 - ENG
TROUBLESHOOTING GUIDE
PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES. PERSONAL INJURY MAY OCCUR. PRIOR TO ATTEMPTING ANY REPAIRS, UNPLUG THE COMPRESSOR AND BLEED OFF TANK AIR PRESSURE.
PROBLEM
Excessive tank pressure - safety valve pops off.
Air leaks at fittings. Tube fittings are not tight enough. Tighten fittings where air can be heard escaping.
Air leaks at or inside check valve.
Air leaks at pressure switch release valve.
CAUSE
Pressure switch does not shut off mo­tor when compressor reaches “cut­out” pressure.
Pressure '"cut-out" too high. Return the outfit to an authorized dealer to check and
Defective or dirty check valve.
Defective pressure release valve.
CORRECTION
Move the pressure switch lever to the “OFF” position. If the outfit doesn’t shut off, unplug. If the electrical contacts are welded together, replace the pressure switch.
adjust, or replace switch.
Check fittings with soapy water solution. DO NOT
OVER-TIGHTEN.
A defective check valve results in a constant air leak at the pressure release valve when there is pressure in the tank and the compressor is shut off. Remove and clean or replace check valve. DO NOT OVER-
TIGHTEN.
Remove and replace the release valve.
Air leaks in air tank or at air tank welds.
Pressure reading on the regu­lated pressure gauge drops when an accessory is used.
Defective check valve.
Defective air tank.
It is normal for “some” pressure drop to occur.
9 - ENG
A defective check valve results in a constant air leak at the pressure release valve when there is pressure in the tank and the compressor is shut off. Remove and clean or replace check valve. DO NOT OVER-
TIGHTEN.
Air tank must be replaced. Do not repair the leak.
DO NOT DRILL INTO, WELD OR OTHERWISE MODIFY AIR TANK OR IT WILL WEAKEN. THE TANK CAN RUPTURE OR EXPLODE.
If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions on page 6.
NOTE
Adjust the regulated pressure under flow conditions (while accessory is be­ing used).
TROUBLESHOOTING GUIDE (Continued)
PROBLEM
Air leak from safety valve.
Knocking Noise
Compressor is not supplying enough air to operate accesso­ries.
Motor will not run.
CAUSE
Possible defect in safety valve.
Defective check valve.
Prolonged excessive use of air.
Compressor is not large enough for air requirement.
Hole in hose.
Check valve restricted.
Air leaks. Tighten fittings. (See Air Leaks Section of Trou-
Tank pressure exceeds pressure switch “cut-in” pressure.
Wrong gauge wire or length of exten­sion cord.
CORRECTION
Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced.
Remove and clean, or replace.
Decrease amount of air usage.
Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor.
Check and replace.
Remove and clean, or replace.
bleshooting Guide.)
Motor will start automatically when tank pressure drops below “cut-in” pressure of pressure switch.
Check for proper gauge wire and cord length.
Regulator knob has continuous air leak. Regulator will not shut off at air outlet.
Remove and clean, or replace.Check valve stuck open.
Loose electrical connections. Check wiring connection inside pressure switch and
terminal box area.
Paint spray on internal motor parts.
Possible defective motor.
Fuse blown, circuit breaker tripped.
Damaged regulator.
Have checked at an Authorized Warranty Service Center. Do not operate the compressor in the paint spray area. See flammable vapor warning.
Have checked at an Authorized Warranty Service Center.
1. Check fuse box for blown fuse and replace, if necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
2. Check for proper fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or operate the compressor in its own branch circuit.
Replace regulator.
10 - ENG
PARTS LIST
OUTLET
PRESSURE GAUGE
PRESSURE
SWITCH
SAFETY VALVE
REGULATOR
AIR TANK
DRAIN VALVE (Not Shown)
TANK PRESSURE
GAUGE
AIR HOSE
COMPRESSOR
ASSEMBLY
CHECK VALVE (Not Shown)
ISOLATOR
AIR HOSE
PARTS AVAILABLE FOR THIS UNIT
DESCRIPTION PART NUMBER
REGULATOR..........................................CAC-4296-1
TANK PRESSURE GAUGE ......................GA-345
OUTLET PRESSURE GUAGE .................GA-345
SAFETY VALVE .....................................TIA-4150
DRAIN VALVE ........................................SS-2707
CHECK VALVE........................................ CAC-1275
ORDER PRESSURE SWITCH
ASSEMBLY .............................................DAC-4105-2 (100 to 125 PSI)
ISOLATOR ...............................................SST-5314-1 (4 used)
AIR HOSE ................................................H-7040-1
11 - ENG
OWNERS MANUAL FOR
PERMANENTLY LUBRICATED AIR COMPRESSOR
(For Home Use Only)
MODEL NO.
FA125
FAC125
WARRANTY
This product is covered by the DeVilbiss one year limited warranty. The warranty can be found in the General Manual or is available upon request.
Attach Sales Receipt Here.
Retain Original Sales Receipt as Proof of Purchase for Warranty Repair Work.
DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615
Loading...