DeVilbiss FAC125, FA125 User Manual

OWNERS MANUAL FOR
PERMANENTLY LUBRICATED AIR COMPRESSOR
(For Home Use Only)
MODEL NO.
FA125
FAC125
SPECIFICATION CHART
MODEL NO.
Horsepower SCFM @ 40 psig SCFM @ 90 psig Cut-In Cut-Out Bore Stroke Voltage/Hertz/ Phase Minimum Branch Circuit Requirement *Fuse Type Amperage at Max. Load Tank Size
*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses.
FA125
1
3.7
2.7
100 PSI
125 PSI
1 3/4" 1 1/4"
115/60/1
15 AMPS
Quick Acting
10 AMPS
2.5 Gallon
FAC125
100 PSI
125 PSI
1 3/4" 1 1/4"
115/60/1
15 AMPS
Quick Acting
10 AMPS
2.5 Gallon
-----
3.7
2.7
TABLE OF CONTENTS
SAFETY GUIDELINES .......................................................... 1
WARRANTY ........................................................................ 2
WARNING CHART ........................................................... 3-4
GLOSSARY ......................................................................... 5
DUTY CYCLE ....................................................................... 5
STORAGE ............................................................................ 5
DESCRIPTION OF OPERATION ........................................... 6
INSTALLATION AND BREAK-IN
PROCEDURES ................................................................ 6-7
Location of Air Compressor ........................................ 6
Extension Cords .......................................................... 6
Voltage and Circuit Protection .................................... 6
Grounding Instructions ................................................7
Additional Regulators and Controls ............................ 7
Break-In Procedures ................................................... 7
OPERATING PROCEDURES ................................................ 8
TROUBLESHOOTING GUIDE ......................................... 9-10
COMPRESSOR PARTS LIST ............................................ 11
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and understand. This information relates to protecting YOUR
SAFETY and PREVENTING EQUIPMENT PROBLEMS. To
help you recognize this informa­tion, we use the symbols to the right. Please read the manual and pay attention to these sections.
Call our Toll Free Number 1-800-888-2468, Ext 2, then 1, to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs.
When ordering repair parts from your local Authorized Service Center, always give the following information:
• Model number of your compressor
• Part number and description of the item you wish to purchase
MGP-FA125-2A 9/18/99
URGENT SAFETY INFORMATION - A HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE.
IMPORTANT SAFETY INFORMATION - A HAZARD THAT MIGHT CAUSE SERIOUS INJURY OR LOSS OF LIFE.
Information for preventing damage to equipment.
Information that you should pay special attention to.
LIMITED WARRANTY
ONE YEAR FROM DATE OF PURCHASE
All merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user). Products covered under this warranty include: air compressors, *air tools, accessories, service parts, pressure washers, and generators used in consumer applications (i.e., personal residential household usage only).
Air compressors, *air tools, accessories, service parts, pressure washers, and generators used in commercial applications (income producing) are covered by a 90 day warranty.
DeVilbiss Air Power/ExCell Manufacturing will repair or replace, at DeVilbiss/ExCell’s option, products or components which have failed within the warranty period. Repair or replacement, and service calls on 60 and 80 gallon air compressors, will be handled by Authorized Warranty Service Centers and will be scheduled and serviced according to the normal work flow and business hours at the service center location, and depending on the availability of replacement parts.
All decisions of DeVilbiss Air Power Company/ExCell Manufacturing with regard to this policy shall be final.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
RESPONSIBILITY OF ORIGINAL PURCHASER (Initial User):
o
Retain original cash register sales receipt as proof of purchase for warranty work.
o
Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s).
o
Deliver or ship the product to the nearest DeVilbiss Air Power/ExCell Manufacturing Authorized Warranty Service Center. Freight costs, if any, must be paid by the purchaser.
o
Air compressors with 60 and 80 gallon tanks only will be inspected at the site of installation. Contact the nearest Authorized Warranty Service Center, that provides on-site service calls, for service call arrangement.
o
If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center, the purchaser should contact DeVilbiss Air Power Company/ExCell Manufacturing.
THIS WARRANTY DOES NOT COVER:
o
Merchandise sold as reconditioned, floor models and/or display models. Any damaged or incomplete equipment sold "as is".
o
Merchandise used as "rental" equipment.
o
Merchandise that has become inoperative because of ordinary wear, misuse, freeze damage, use of improper chemicals, negligence, accident, improper and/or unauthorized repair or alterations including failure to operate the product in accordance with the instructions provided in the Owners Manual (s) supplied with the product. *Air Tools: O-Rings and driver blades are considered ordinary wear parts, therefore, they are warranted for a period of 45 days from the date of purchase.
o
An air compressor that pumps air more than 50% during a one hour period is considered misuse because the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.
o
Merchandise sold by DeVilbiss Air Power/ExCell Manufacturing which has been manufactured by and identified as the product of another company. The product manufacturer's warranty will apply.
o
Repair and transportation costs of merchandise determined not to be defective.
o
Cost associated with assembly, required oil, adjustments or other installation and start-up cost.
o
ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
o
IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
Form: SP-100-F - 10/28/97
213 Industrial Drive • Jackson, TN 38301-9615
Telephone: 1-800-888-2468 , Ext. 2
FAX: 1-800-888-9036
2 - ENG
IMPORTANT SAFETY INSTRUCTIONS
• SAVE THESE INSTRUCTIONS •
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUC­TIONS BEFORE USING THIS EQUIPMENT.
HAZARD
RISK OF BURSTING
WHAT CAN HAPPEN
AIR TANK
THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT
IN A VIOLENT TANK EXPLOSION:
1. FAILURE TO PROPERLY DRAIN CONDENSED CAUSING RUST AND THINNING OF THE STEEL TANK.
2. MODIFICATIONS OR ATTEMPTED REPAIRS
3. UNAUTHORIZED MODIFICATIONS TO THE
PRESSURE SWITCH, SAFETY VALVE, OR
OTHER COMPONENTS WHICH
ANY
CONTROL TANK PRESSURE.
WATER FROM THE TANK,
TO THE TANK.
ATTACHMENTS & ACCESSORIES
EXCEEDING THE PRESSURE RATING OF AIR TOOLS, SPRAY GUNS, AIR OPERATED ACCES- SORIES, TIRES AND OTHER INFLATABLES CAN CAUSE THEM TO EXPLODE OR FLY APART,
AND COULD RESULT IN SERIOUS INJURY.
HOW TO PREVENT IT
DRAIN TANK DAILY OR AFTER EACH USE.
IF TANK DEVELOPS A LEAK, REPLACE IT IMMEDIATELY WITH A NEW TANK OR NEW COMPRESSOR OUTFIT.
NEVER DRILL INTO, WELD, OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS
ATTACHMENTS.
THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES. NEVER
MAKE ADJUSTMENTS OR PARTS SUBSTI­TUTIONS TO ALTER THE FACTORY SET
OPERATING PRESSURES.
FOLLOW THE EQUIPMENT MANUFACTUR­ERS RECOMMENDATION AND NEVER EXCEED THE MAXIMUM ALLOWABLE PRES­SURE RATING OF ATTACHMENTS. NEVER
USE COMPRESSOR TO INFLATE SMALL LOW-PRESSURE OBJECTS SUCH AS CHILDREN’S TOYS, FOOTBALLS, BASKETBALLS. ETC.
RISK OF
EXPLOSION OR FIRE
RISK OF
ELECTRICAL SHOCK
IT IS NORMAL FOR ELECTRICAL CONTACTS
WITHIN THE MOTOR AND PRESSURE SWITCH
TO SPARK.
IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION.
RESTRICTING ANY OF THE COMPRESSOR VENTILATION OPENINGS WILL CAUSE SERI­OUS OVERHEATING AND COULD CAUSE FIRE.
YOUR AIR COMPRESSOR IS POWERED BY ELECTRICITY. LIKE ANY OTHER ELECTRI- CALLY POWERED DEVICE, IF IT IS NOT USED PROPERLY IT MAY CAUSE ELECTRIC SHOCK.
ALWAYS OPERATE THE COMPRESSOR IN A WELL VENTILATED AREA FREE OF COM-
BUSTIBLE MATERIALS, GASOLINE OR SOL­VENT VAPORS.
IF SPRAYING FLAMMABLE MATERIALS, LO­CATE COMPRESSOR AT LEAST 20 FEET AWAY FROM SPRAY AREA. AN ADDITIONAL
LENGTH OF HOSE MAY BE REQUIRED.
STORE FLAMMABLE MATERIALS IN A SECURE LOCATION AWAY FROM COM­PRESSOR.
NEVER PLACE OBJECTS AGAINST OR ON TOP OF COMPRESSOR. OPERATE COM­PRESSOR IN AN OPEN AREA AT LEAST 12 INCHES AWAY FROM ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE
FLOW OF FRESH AIR TO THE VENTILATION OPENINGS.
NEVER OPERATE THE COMPRESSOR OUT­DOORS WHEN IT IS RAINING OR IN WET CONDITIONS.
NEVER OPERATE COMPRESSOR WITH COVER COMPONENTS REMOVED OR DAM-
AGED.
3 - ENG
CONTINUE NEXT PAGE
*
HAZARD
WHAT CAN HAPPEN
HOW TO PREVENT IT
RISK OF
ELECTRICAL SHOCK
RISK FROM
FLYING OBJECTS
RISK TO BREATHING
REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN RESULT IN SERIOUS INJURY OR DEATH BY ELECTROCUTION.
ELECTRICAL GROUNDING:
PROVIDE ADEQUATE GROUNDING TO THIS PRODUCT COULD RESULT IN SERIOUS INJURY OR DEATH FROM ELECTROCU­TION. SEE GROUNDING INSTRUCTIONS.
COMPRESSED AIR STREAM CAN
THE CAUSE SOFT TISSUE DAMAGE TO EX­POSED SKIN AND CAN PROPEL DIRT, CHIPS, OBJECTS AT PROPERTY DAMAGE OR PERSONAL INJURY.
THE COMPRESSED AIR FROM YOUR COMPRESSOR IS NOT SAFE FOR BREATH- ING! THE AIR STREAM MAY CONTAIN CARBON MONOXIDE, TOXIC VAPORS OR SOLID PARTICLES.
LOOSE PARTICLES AND SMALL
HIGH SPEED, RESULTING IN
FAILURE TO
ANY ELECTRICAL WIRING OR REPAIRS REQUIRE ON THIS PRODUCT SHOULD BE
PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE
WITH NATIONAL AND LOCAL ELECTRICAL CODES.
MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH THE COMPRESSOR IS CONNECTED PROVIDES PROPER ELEC­TRICAL GROUNDING, CORRECT VOLTAGE AND ADEQUATE FUSE PROTECTION.
ALWAYS WEAR ANSI Z87.1 APPROVED SAFETY GLASSES WITH SIDE SHIELDS
WHEN USING THE COMPRESSOR.
NEVER POINT ANY NOZZLE OR SPRAYER TOWARD ANY PART OF THE BODY OR AT OTHER PEOPLE OR ANIMALS.
NEVER INHALE AIR FROM THE COMPRES­SOR EITHER DIRECTLY OR FROM A
BREATHING DEVICE CONNECTED TO THE COMPRESSOR.
RISK FROM
MOVING PARTS
SPRAYED MATERIALS SUCH AS PAINT,
PAINT SOLVENTS, PAINT REMOVER, INSECTICIDES, WEED KILLERS, ETC.. CONTAIN HARMFUL VAPORS AND POI­SONS.
MOVING PARTS CAN CAUSE SERIOUS INJURY OR DAMAGE IF THEY COME INTO
CONTACT WITH YOU OR YOUR CLOTHING.
ATTEMPTING TO OPERATE OR REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND ELECTRICAL SHOCK.
A PORTABLE COMPRESSOR CAN FALL FROM A TABLE, WORKBENCH OR ROOF
CAUSING DAMAGE TO THE COMPRESSOR WHICH COULD EXPOSE YOU TO HAZARD­OUS MOVING OR ELECTRICAL PARTS.
THE COMPRESSOR CYCLES AUTOMATI­CALLY WHEN THE PRESSURE SWITCH IS IN THE ON/AUTO POSITION.
WORK IN AN AREA WITH GOOD CROSS­VENTILATION. READ AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON THE LABEL OR SAFETY DATA SHEETS FOR THE MATERIAL YOU ARE SPRAYING. USE A NIOSH/MSHA APPROVED RESPIRATOR
DESIGNED FOR USE WITH YOUR SPECIFIC APPLICATION.
DO NOT REMOVE THE PROTECTIVE COVERS FROM THIS PRODUCT. NEVER OPERATE THE COMPRESSOR WITH GUARDS OR COVERS WHICH ARE DAM-
AGED OR REMOVED.
ANY REPAIRS REQUIRED ON THIS PROD-
UCT SHOULD BE PERFORMED BY AUTHO­RIZED SERVICE CENTER PERSONNEL.
ALWAYS OPERATE COMPRESSOR IN A STABLE SECURE POSITION TO PREVENT
ACCIDENTAL MOVEMENT OF THE UNIT.
NEVER OPERATE COMPRESSOR ON A ROOF OR OTHER ELEVATED POSITION. USE ADDITIONAL AIR HOSE TO REACH HIGH LOCATIONS.
ALWAYS TURN OFF THE COMPRESSOR, BLEED PRESSURE FROM THE AIR HOSE AND TANK UNPLUG FROM ELECTRICAL OUTLET BEFORE PERFORMING MAINTE­NANCE OR ATTACHING TOOLS AND AC-
CESSORIES.
RISK OF BURNS
CTMCWPS — 5/1/97
TOUCHING EXPOSED METAL SUCH AS THE
COMPRESSOR HEAD OR OUTLET TUBE
CAN RESULT IN SERIOUS BURNS.
4 - ENG
NEVER TOUCH ANY EXPOSED METAL PARTS ON COMPRESSOR DURING OR IMMEDIATELY AFTER OPERATION. COM­PRESSOR WILL REMAIN HOT FOR SEV-
ERAL MINUTES AFTER OPERATION.
Loading...
+ 8 hidden pages