Product description
Humidity Sensor allows you to protect your
building and belongings by monitoring the
temperature and humidity levels in any room,
and receive immediate alerts if the climate
uctuates to unsafe levels.
By supervising the indoor climate, the wireless
Humidity Sensor helps maintain the ideal
comfort level and protect interior, electronics,
musical instruments, furniture, artwork, and
any other humidity-sensitive household item.
Getting started
• Open the sensor by pushing the switch and
pulling the top of the casing.
NOTE: Do not remove the product label as it contains important information.
• Insert two AA batteries respecting the
polarities.
• The Humidity Sensor will start searching
(up to 15 minutes) for a ZigBee network to
join.
• Make sure that the ZigBee network is open for joining devices and will accept this Humidity Sensor.
• If the scanning has timed out, a short press on the button will restart it.
Placement
PLACE THE SENSOR
• Indoors at a temperature between 0-50°C.
• In a room, where it is necessary to detect humidity.
• On a wall, where it is reachable for the battery testing and maintenance.
WALL
50 cm
150 cm
DO NOT PLACE THE SENSOR
• On the ceiling
• Behind obstacles, e.g. curtains.
• Under direct sunlight or bright light.
• Close to radiators.
Close to electromagnetic elds.
Installation
1. Open the casing of the Humidity Sensor
and remove the batteries.
NOTE: Be aware that electronics are sensitive to static electricity, so aim to discharge before touching, and avoid touching any components inside the device.
2. Use double-sided tape or screws to attach
the sensor on the wall.
3. Insert batteries respecting the polarities.
4. Make sure that the Humidity Sensor has
joined a network before closing the casing.
Resetting
Resetting is needed if you want to connect
your Humidity Sensor to another gateway or
if you need to perform a factory reset to avoid
abnormal behavior.
STEPS FOR RESETTING
1. Open the casing of the Humidity Sensor.
2. Press and hold the button until the LED
ashes continuously.
3. Release the button.
4. Resetting process is complete when the
LED starts to blink.
Battery replacement
• Open the casing of the Humidity Sensor to
replace the batteries.
• Replace the batteries respecting the
polarities.
• Close the casing of the sensor.
CAUTION: When removing cover for battery
change - Electrostatic Discharge (ESD) can
harm electronic components inside
Fault nding & cleaning
• In case of a bad or wireless weak signal,
change the location of the Humidity Sensor.
Otherwise you can relocate your gateway
or strengthen the signal with a smart plug.
Other information
• Do not paint the sensor.
at the end of life. This is electronic waste
which should be recycled.
All rights reserved.
Develco Products assumes no responsibility
for any errors, which may appear in this
manual.Furthermore, Develco Products
reserves the right to alter the hardware,
software, and/or specications detailed
herein at any time without notice, and Develco
Products does not make any commitment to
update the information contained herein. All
the trademarks listed herein are owned by
their respective owners.
Distributed by Develco Products A/S Olof Palmes Allé 40 8200 Aarhus Denmark
CE certication
CE certication
The CE mark axed to this product conrms
its compliance with the European Directives
which apply to the product and, in particular,
its compliance with the harmonized standards
and specications.
IN ACCORDANCE WITH THE DIRECTIVES
• Radio & Telecommunications Terminal Equipment Directive 1999/5/EC
• EMC Directive 2004/108/EC
• RoHS Directive 2011/65/EU
Other certications
Other certications
ZigBee Home Automation certied
FCC statement
FCC statement
Changes or modications to the equipment not
expressly approved by the party responsible
for compliance could void the user’s authority
to operate the equipment.
NOTE: This equipment has been tested and
found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instructions, may cause harmful interference
to radio communications. However, there is no
guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful
interference to radio or television reception,
which can be determined by turning the
equipment o and on, the user is encouraged
to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on
a circuit dierent from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/
TV technician for help.
This device complies with FCC RF radiation
exposure limits set forth for an uncontrolled
environment. The antenna used for this
transmitter must be installed to provide a
separation distance of at least 20 cm from
all persons and must not be co-located
or operating in conjunction with any other
antenna or transmitter.
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired operation.
IC statement
IC statement
English
This device complies with Industry Canada’s
Licence-Exempt RSSs. Operation is subject to
the following two conditions:
1. This device may not cause interference, and
2. this device must accept any interference,
including interference that may cause undesired
operation of the device.
Français
Le présent appareil est conforme aux CNR
d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage;
2. l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le
fonctionnement.
ISED statement
ISED statement
Innovation, Science and Economic
Development Canada ICES-003 Compliance
Label: CAN ICES-3 (B)/NMB-3(B).
Loading...