DEV 2813, DEV 2851, DEV 2811, DEV 2853 Customer's Manual

Page 1
Customer Documentation
DEV 2811 (C-Band, 1:8)
DEV 2813 (C-Band, 1:16) DEV 2851 (Ku-Band, 1:8)
DEV 2853 (Ku-Band, 1:16)
DEV Systemtechnik GmbH
Grüner Weg 4A
61169 Friedberg
GERMANY
Tel: +49 6031 6975 100
Fax: +49 6031 6975 114
support@dev-systemtechnik.com
www.dev-systemtechnik.com
Revision: 2017-12-14
DEV 91-0042-E
Page 2
Customer Documentation DEV 281x, DEV 285x
2 Copyright DEV Systemtechnik GmbH 2007-2017
TABLE OF CONTENTS
1 REVISION HISTORY ------------------------------------------------------------------------------- 2 2 INTRODUCTION ------------------------------------------------------------------------------------ 3
2.1 Warranty ----------------------------------------------------------------------------------------------- 3
2.2 Limitation of Warranty ------------------------------------------------------------------------------ 3
3 PRODUCT DESCRIPTION ----------------------------------------------------------------------- 4
3.1 Product Drawings ------------------------------------------------------------------------------------ 5
3.1.1 DEV 2811 -------------------------------- -------------------------------------------------------------- 5
3.1.2 DEV 2813 -------------------------------- -------------------------------------------------------------- 5
3.1.3 DEV 2851 -------------------------------- -------------------------------------------------------------- 6
3.1.4 DEV 2853 -------------------------------- -------------------------------------------------------------- 6
4 INSTALLATION INSTRUCTIONS--------------------------------------------------------------- 7
4.1 Scope of Delivery ------------------------------------------------------------------------------------ 7
4.2 Installation of the Product -------------------------------------------------------------------------- 7
4.2.1 Mechanical Integration of the Product ---------------------------------------------------------- 7
4.2.2 Grounding and Power Connection --------------------------------------------------------------- 7
4.2.3 Connection of RF Cables -------------------------------------------------------------------------- 8
4.3 Maintenance of the Product ---------------------------------------------------------------- ------- 8
5 OPERATION OF THE PRODUCT -------------------------------------------------------------- 9 6 ERROR INDICATION------------------------------------------------------------------------------- 9 7 CONNECTORS -------------------------------------------------------------------------------------- 9 8 TECHNICAL DATA --------------------------------------------------------------------------------- 9 9 CONFORMANCE DECLARATIONS --------------------------------------------------------- 10
9.1 Certificate of Conformance ---------------------------------------------------------------------- 10
9.2 EU Declaration of Conformity ------------------------------------------------------------------- 13
10 GLOSSARY ----------------------------------------------------------------------------------------- 14 11 NOTES ----------------------------------------------------------------------------------------------- 14
1 REVISION HISTORY
Revision (Date)
Author
Short Description
A (07-Mar-2007)
WP
Initial version
B (04-Sep-2008)
WP
Complete rework to new document format
C (10-Mar-2009)
WP
Minor corrections
D (08-Oct-2014)
WP
Complete rework, integration of DEV 285x
E (14-Dec-2017)
WP
Minor changes
Page 3
Customer Documentation DEV 281x, DEV 285x
Copyright DEV Systemtechnik GmbH 2007-2017 3
2 INTRODUCTION
Thank you for purchasing a distribution amplifier DEV 28fx. This customer documentation is intended to familiarize you with the installation and operation of the device.
The DEV 28fx is a series of 1:8 (DEV 28f1) or 1:16 (DEV 28f3) distribution amplifiers designed for professional use. The DEV 281x products are used to distribute small C-Band signals in the range 3.2…4.2 GHz and the DEV 285x products are used to distribute small Ku-Band signals in the range
10.95…12.75 GHz. DEV Systemtechnik GmbH declares that this equipment meets all relevant
standards and rules. The unit carries a CE mark.
Please read all instructions before installation or usage of the product!
2.1 WARRANTY
The product has a warranty against defects in material and workmanship for a period of two years from the date of shipment. During the warranty period DEV Systemtechnik will, at its option, either repair or replace the product if it turns out to be defective.
For warranty service or repair, the product must be returned to DEV Systemtechnik. The customer has to pay shipping charges to DEV Systemtechnik and DEV Systemtechnik will pay shipping charges to return the product to the customer. However, the customer is obliged to pay all duties, all taxes, and all other additional costs arising from the shipment of the product.
2.2 LIMITATION OF WARRANTY
The preceding warranty does not apply to defects resulting from:
improper site preparation or site maintenance; improper or inadequate interfacing of the product; unauthorized modification or misuse of the product; improper or inadequate maintenance of the product; operation beyond the environmental conditions specified for the product.
Warning: Disconnect the unit from any external power line before opening of the housing. In any case, the unit is to be opened by especially trained people, only.
Page 4
Customer Documentation DEV 281x, DEV 285x
4 Copyright DEV Systemtechnik GmbH 2007-2017
3 PRODUCT DESCRIPTION
This customer documentation covers the following products:
DEV 2811 1:8 Distribution Amplifier; 3.2…4.2 GHz; 50 Ohm, SMA (f)DEV 2813 1:16 Distribution Amplifier; 3.2…4.2 GHz; 50 Ohm, SMA (f)
DEV 2851 1:8 Distribution Amplifier; 10.95…12.75 GHz; 50 Ohm, SMA (f)DEV 2853 1:16 Distribution Amplifier; 10.95…12.75 GHz; 50 Ohm, SMA (f)
All distribution amplifiers are designed in a way, that the signal applied to the input port is routed to an amplifier and then split into 8 or 16 output signals.
All products are delivered in a 1 RU chassis, are equipped with female 50 Ohm SMA connectors for the input and output ports, and provide redundant power supplies.
Po w er S upp ly 1 Po w er S upp ly 2 Fa ilure
1 2 3
On the right at the front side of the chassis, three LEDs are located signalizing the power supply operating status of the device:
"Power Supply 1" LED (1)
If this green LED is on, the first power supply unit provides a secondary voltage feeding the device partially.
"Power Supply 2" LED (2)
If this green LED is on, the second power supply unit provides a secondary voltage feeding the device partially.
"Failure" LED (3)
This red LED is on if either the first or the second power supply unit does not deliver any secondary voltage. The reason for this can be a defective power supply, a defective primary protection fuse, or a missing primary voltage.
Page 5
Customer Documentation DEV 281x, DEV 285x
Copyright DEV Systemtechnik GmbH 2007-2017 5
3.1 PRODUCT DRAWINGS
As stated above there are available four different product versions. Structural and from the layout, the different versions are very similar.
3.1.1 DEV 2811
Front View:
DEV 28 11
1:8 Distr ibut ion A mpl ifier 3.2. ..4.2 GHz
Pow er S upp ly 1 Pow er S upp ly 2 Fail ure
1 2 3
1
Green LED indicating the operation of "Power Supply 1"
2
Green LED indicating the operation of "Power Supply 2"
3
Red LED indicating a "Failure" of one of the power supplies
Rear View:
Fus e 2 A T
WA RN ING :
Disco nnec t pow er befor e ope ning!
Fus e 2 A T
100 ...24 0 V ~
50/60 Hz
40 V A
1
No D C!
Com 8
7
653
21 4
G
P1 Inp ut
Ou tput s
F1 F2P2
G
Grounding bolt
P
1
AC plug for power supply unit 1
F
1
Fuse for power supply unit 1
P
2
AC plug for power supply unit 2
F
2
Fuse for power supply unit 2
Input
Input port labeled "Com", SMA (f)
Outputs
Output ports labeled "1"…"8", SMA (f)
3.1.2 DEV 2813
Front View:
Pow er S upp ly 1 Pow er S upp ly 2 Fail ure
DEV 28 13
1:16 Dis tribu tion Amp lifie r 3.2 ...4.2 GH z
1 2 3
1
Green LED indicating the operation of "Power Supply 1"
2
Green LED indicating the operation of "Power Supply 2"
3
Red LED indicating a "Failure" of one of the power supplies
Rear View:
Fus e 2 A T
WA RN ING :
Disco nnec t pow er befor e ope ning!
Fus e 2 A T
100 ...24 0 V ~
50/60 Hz
40 V A
No D C!
Com
87653
21 4
1615
14
13
11
109
12
G
P1 Inpu t
Ou tput s
F1 F2P2
G
Grounding bolt
P
1
AC plug for power supply unit 1
F
1
Fuse for power supply unit 1
P
2
AC plug for power supply unit 2
F
2
Fuse for power supply unit 2
Input
Input port labeled "Com", SMA (f)
Outputs
Output ports labeled "1"…"16", SMA (f)
Page 6
Customer Documentation DEV 281x, DEV 285x
6 Copyright DEV Systemtechnik GmbH 2007-2017
3.1.3 DEV 2851
Front View:
Pow er S upp ly 1 Pow er S upp ly 2 Fail ure
DEV 28 51
1:8 Dis trib utio n A mp lifi er 1 0.9 5… 12 .75 GH z
1 2 3
1
Green LED indicating the operation of "Power Supply 1"
2
Green LED indicating the operation of "Power Supply 2"
3
Red LED indicating a "Failure" of one of the power supplies
Rear View:
Fus e 2 A T
WA RN ING :
Disco nnec t pow er befor e ope ning!
Fus e 2 A T
100 ...24 0 V ~
50/60 Hz
40 V A
1 234
5 678
No D C!
Com
G
P1 Inp ut
Ou tput s
F1 F2P2
G
Grounding bolt
P
1
AC plug for power supply unit 1
F
1
Fuse for power supply unit 1
P
2
AC plug for power supply unit 2
F
2
Fuse for power supply unit 2
Input
Input port labeled "Com", SMA (f)
Outputs
Output ports labeled "1"…"8", SMA (f)
3.1.4 DEV 2853
Front View:
Pow er S upp ly 1 Pow er S upp ly 2 Fail ure
DEV 28 53
1:16 Di stri but ion Am pli fier 10. 95… 1 2.7 5 G Hz
1 2 3
1
Green LED indicating the operation of "Power Supply 1"
2
Green LED indicating the operation of "Power Supply 2"
3
Red LED indicating a "Failure" of one of the power supplies
Rear View:
Fus e 2 A T
WA RN ING :
Disco nnec t pow er befor e ope ning!
Fus e 2 A T
100 ...24 0 V ~
50/60 Hz
40 V A
1 234
5 678
9 10
11 121314
15 16
No D C!
Com
G
P1 Inp ut
Ou tput s
F1 F2P2
G
Grounding bolt
P
1
AC plug for power supply unit 1
F
1
Fuse for power supply unit 1
P
2
AC plug for power supply unit 2
F
2
Fuse for power supply unit 2
Input
Input port labeled "Com", SMA (f)
Outputs
Output ports labeled "1"…"16", SMA (f)
Page 7
Customer Documentation DEV 281x, DEV 285x
Copyright DEV Systemtechnik GmbH 2007-2017 7
4 INSTALLATION INSTRUCTIONS
4.1 SCOPE OF DELIVERY
1 * DEV 2811, or DEV 2813, or DEV 2851, or DEV 2853 1 * Customer documentation (this document)
4.2 INSTALLATION OF THE PRODUCT
4.2.1 Mechanical Integration of the Product
For the integration in a 19" rack, the rack slots must be prepared with rails for the chassis. After inserting the chassis in the rack, fix the chassis with 4 screws to the rack at its rack mount flanges.
Warning: It is not permitted to fix the chassis on the rack mount flanges, only.
4.2.2 Grounding and Power Connection
The chassis needs to be connected to the 19" rack via a ground wire. The grounding bolt is located on the left at the rear side of the product:
Fu se 2 A T
WARNIN G :
Disco nn ect p owe r be for e opening !
Fu se 2 A T
10 0...240 V ~
50 /60 H z
40 VA
G
P1 F1 F2P2
Take off the upper nut and the first washer of to the grounding bolt (labeled "G" in the figure above). Then connect the grounding cable, which must have a ring tongue terminal matching for the M4 fastening bolt. The washer and the nut then have to be tightened again.
Finally, connect two power cords to the primary connectors (labeled "P1" & "P2"). It is recommended to use two separately fused phases of the available electrical outlets.
Note: It is highly recommended to power up the device after the installation of
the RF cables (please refer to chapter 4.2.3)!
The power lines are fused separately; the fuse holders (labeled
"F1" & "F2") are located below the corresponding power inlet ("P1" & "P2"). If a fuse has to be exchanged, unplug the device completely and use 2 A T 5*20 mm glass fuses for replacement only!
Page 8
Customer Documentation DEV 281x, DEV 285x
8 Copyright DEV Systemtechnik GmbH 2007-2017
4.2.3 Connection of RF Cables
Apply strain relieves to the RF cables which are to be connected to the chassis in a way, that the connectors of the device are not stressed mechanically.
When connecting RF cables to the chassis, each connector is to be tightened with a torque wrench adjusted to 1 Nm (141.6 ozf-in), which is the recommended torque to be applied to 50 Ohm SMA connectors.
Note:
Best signal quality is achieved by connecting the signal receivers
symmetrically to the outputs
- 1…4 & 5…8 of a 1:8 splitter (DEV 2811, DEV 2851)
- 1…4 / 5…8 & 9…12 / 13…16 of a 1:16 splitter (DEV 2813, DEV 2853) and by connecting 50 Ohm SMA loads to the unused ports
If all cables are connected, the device can be powered up.
4.3 MAINTENANCE OF THE PRODUCT
The product is maintenance-free. Cleaning the surface of the chassis should be done carefully with a dry lint­free cloth.
Page 9
Customer Documentation DEV 281x, DEV 285x
Copyright DEV Systemtechnik GmbH 2007-2017 9
5 OPERATION OF THE PRODUCT
After going through the installation steps as described above, the device is ready to use. There are no elements (buttons etc.) to be operated after power-up. The power supply operating status of the device is indicated via LEDs, which were already presented in chapter 3.
6 ERROR INDICATION
As the only hardware error indication just the "Failure" LED (please refer to chapter 3) is available for this type of devices.
7 CONNECTORS
AC Power Plugs
Connector: IEC rubber connector (male) IEC 60320 C14 Connector screws: none
AC Power Plug
Pin
Functionality
Pin 1
L (Live/Phase)
Pin 2
PE (Protective Earth)
Pin 3
N (Neutral)
8 TECHNICAL DATA
The technical data is stated in the spec sheet; please refer to
www.dev-systemtechnik.com.
1
2
3
Page 10
Customer Documentation DEV 281x, DEV 285x
10 Copyright DEV Systemtechnik GmbH 2007-2017
9 CONFORMANCE DECLARATIONS
9.1 CERTIFICATE OF CONFORMANCE
Since DEV Systemtechnik develops and produces in Germany, the Certificate of Conformance for each product or product series is to be issued in German (as stated on the next page).
For the ease of comprehension, the harmonized standards that were taken into consideration during development and production are listed here in English:
DIN EN 50083-2:2016-03 Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment; German version EN 50083-2:2012 + A1:2015 DIN EN 55022:2011-12 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement (CISPR 22:2008, modified); German version EN 55022:2010 DIN EN 55024:2016-05 Information technology equipment - Immunity characteristics - Limits and methods of measurement (CISPR 24:2010 + Cor.:2011 + A1:2015); German version EN 55024:2010 + A1:2015 DIN EN 61000-3-2:2015-03 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) (IEC 61000-3-2:2014); German version EN 61000-3-2:2014 DIN EN 61000-3-3:2014-03 Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations, and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection (IEC 61000-3-3:2013); German version EN 61000-3-3:2013 DIN EN 62368-1:2016-05 Audio/video, information and communication technology equipment - Part 1: Safety requirements (IEC 62368-1:2014, modified + Cor.:2015); German version EN 62368-1:2014 + AC:2015
Page 11
Customer Documentation DEV 281x, DEV 285x
Copyright DEV Systemtechnik GmbH 2007-2017 11
Konformitätserklärung nach
EMV-Richtlinie (2014/30/EU)
Niederspannungsrichtlinie (2014/35/EU)
Der Hersteller: DEV Systemtechnik GmbH Grüner Weg 4A 61169 Friedberg
erklärt hiermit in alleiniger Verantwortung, dass nachfolgend bezeichnete Produkte in denen von uns in Verkehr gebrachten Ausführungen:
Bezeichnung der Produkte: Aktive C-Band oder Ku-Band Splitter 1:8 oder 1:16 Produktnummern DEV 2811, DEV 2813, DEV 2851, DEV 2853 Baujahr: ab 2008
auf die sich diese Erklärung bezieht, mit den folgenden Normen übereinstimmen. Bei der Konzipierung und beim Bau der Geräte wurden die folgenden harmonisierten Normen
berücksichtigt: DIN EN 50083-2:2016-03 Kabelnetze für Fernsehsignale, Tonsignale und interaktive Dienste -
Teil 2: Elektromagnetische Verträglichkeit von Geräten; Deutsche Fassung EN 50083-2:2012 + A1:2015 DIN EN 55022:2011-12 Einrichtungen der Informationstechnik - Funkstöreigenschaften - Grenzwerte und Messverfahren (CISPR 22:2008, modifiziert); Deutsche Fassung EN 55022:2010 DIN EN 55024:2016-05 Einrichtungen der Informationstechnik - Störfestigkeitseigenschaften - Grenzwerte und Prüfverfahren (CISPR 24:2010 + Cor.:2011 + A1:2015); Deutsche Fassung EN 55024:2010 + A1:2015 DIN EN 61000-3-2:2015-03 Elektromagnetische Verträglichkeit (EMV) - Teil 3-2: Grenzwerte - Grenzwerte für Oberschwingungsströme (Geräte-Eingangsstrom ≤16 A je Leiter) (IEC 61000-3-2:2014); Deutsche Fassung EN 61000-3-2:2014 DIN EN 61000-3-3:2014-03 Elektromagnetische Verträglichkeit (EMV) - Teil 3-3: Grenzwerte - Begrenzung von Spannungsänderungen, Spannungsschwankungen und Flicker in öffentlichen Niederspannungs-Versorgungsnetzen für Geräte mit einem Bemessungsstrom ≤16 A je Leiter, die keiner Sonderanschlussbedingung unterliegen (IEC 61000-3-3:2013); Deutsche Fassung EN 61000-3-3:2013 DIN EN 62368-1:2016-05 Einrichtungen für Audio/Video-, Informations- und Kommunikationstechnik - Teil 1: Sicherheitsanforderungen (IEC 62368-1:2014, modifiziert + Cor.:2015); Deutsche Fassung EN 62368-1:2014 + AC:2015
DEV Systemtechnik GmbH _____________________________ Friedberg, 14.12.2017 Jörg Schmidt Managing Director
Page 12
Customer Documentation DEV 281x, DEV 285x
12 Copyright DEV Systemtechnik GmbH 2007-2017
(This Page Intentionally Left Blank)
Page 13
Customer Documentation DEV 281x, DEV 285x
Copyright DEV Systemtechnik GmbH 2007-2017 13
9.2 EU DECLARATION OF CONFORMITY
As original manufacturer of Electrical & Electronic Equipment (EEE) DEV Systemtechnik GmbH
Grüner Weg 4A 61169 Friedberg GERMANY
declares under sole responsibility that the
Products:
DEV 2811 1:8 Distribution Amplifier; 3.2…4.2 GHz; 50 Ohm, SMA (f) DEV 2813 1:16 Distribution Amplifier; 3.2…4.2 GHz; 50 Ohm, SMA (f)
DEV 2851 1:8 Distribution Amplifier; 10.95…12.75 GHz; 50 Ohm, SMA (f) DEV 2853 1:16 Distribution Amplifier; 10.95…12.75 GHz; 50 Ohm, SMA (f)
to which this declaration refers to, is in conformity with Directive 2011/65/EU of the European Parliament and of the Council of 8-Jun-2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS).
Signed for and on behalf of DEV Systemtechnik GmbH Name: Jörg Schmidt Position: Managing Director Place and date of issue: Friedberg, 14-Dec-2017
Signature:
Page 14
Customer Documentation DEV 281x, DEV 285x
14 Copyright DEV Systemtechnik GmbH 2007-2017
10 GLOSSARY
AC
Alternating Current
LED
Light Emitting Diode
RF
Radio Frequency
RU
Rack Unit: Units of vertical height. 1 RU = 1 ¾" = 44.45 mm Sometimes simply referred to as "U" (Unit).
SAT/IF
SATellite Intermediate Frequency
11 NOTES
Loading...