Thank you for purchasing a DEV 1953 Universal Switch Chassis. This user manual is
intended to familiarize you with the installation and operation of the product.
The DEV 1953 chassis for professional use can be equipped with modules with the
same or with different functionalities, to realize a switching solution for up to
16 channels. There is a large selection of switch modules for different applications;
in addition, there are available some modules without switching functionality that
can be applied to the DEV 1953 chassis as well.
DEV Systemtechnik GmbH declares that this equipment meets all relevant
standards and rules. The unit carries a CE mark.
Please read all instructions before installation or usage of the product!
2.1 Warranty
The product has a warranty against defects in material and workmanship for a
period of two years from the date of shipment.
During the warranty period DEV Systemtechnik will, at its option, either repair or
replace the product if it turns out to be defective.
For warranty, service, or repair, the product must be returned to DEV Systemtechnik. The customer has to pay shipping charges to DEV Systemtechnik and
DEV Systemtechnik will pay shipping charges to return the product to the customer.
However, the customer is obliged to pay all duties, all taxes, and all other additional
costs arising from the shipment of the product.
DEV Systemtechnik warrants that the software and firmware designated by
DEV Systemtechnik for use with the product will execute its programming
instructions if installed properly. DEV Systemtechnik does not warrant that the
operation of the product, software, or firmware will be uninterrupted or error-free.
2.2 Limitation of Warranty
The preceding warranty does not apply to defects resulting from:
improper site preparation or site maintenance;
improper or inadequate interfacing of the product;
unauthorized modification or misuse of the product;
the application of software supplied by the customer;
improper or inadequate maintenance of the product;
operation beyond the environmental conditions specified for the product.
2.3 Warnings
The following safety measures must be observed during all phases of operation,
service, and repair of the device. Failure to comply with the safety precautions or
warnings in this document violates safety standards of design, manufacturing, and
intended use of the device and may affect the built-in protections. DEV Systemtechnik shall not be liable for the user's failure to comply with these requirements.
Disconnect the device from any external power line before opening of the housing.
In any case, the device is to be opened by trained service staff, only.
8 Copyright DEV Systemtechnik GmbH 2015-2017
Page 9
User Manual DEV 1953
Environmental Conditions
The device is designed for indoor use and for an ambient temperature range.
Mechanical Integration
It is not permitted to fix the chassis on the rack mount flanges, only. Balanced
weight distribution of the chassis has to be ensured by placing it on a solid surface
or by using rack rails.
Sufficient airflow through the chassis must be ensured to achieve best cooling
results. Do not block or obstruct the airflow through the chassis at the front and at
the rear side, e.g. by placing large components close to the rear side.
Grounding, AC Connection, Cables
To minimize shock hazard the device must be connected to an electrical ground via
a ground wire, please refer to chapter 4.2.2.
For the AC connection, the device must be connected to the AC power supply
mains through two power cables with three conductors and with the ground wire
firmly connected to an electrical ground (safety ground) at the power outlet. Any
interruption of the protective ground conductor will cause a potential shock hazard
that might cause personal injury.
Risk of electrical shock and energy hazard:
Disconnecting a single power supply line only does not interrupt the AC supply
(with Option 14: DC supply) of the device. To isolate the device completely,
disconnect both power supply lines.
Do not connect the device to AC mains supply exceeding the specifications for input
voltage and frequency. The recommended AC cables to be applied are standard
high temperature power cables with type IEC 60320-C13 appliance plug appropriately rated to the conditions of the country where the device is operated.
With applied Option 14, the device is supplied with DC voltage instead of AC mains.
In this case, do not connect the device to DC mains supply exceeding the
specifications for input voltage. For the DC supply wiring use cables with an
appropriate wire size. The pin assignment of the DC supply connector is stated in
chapter 7.
Laser Safety (applies if equipped with Optical Switch Modules DEV 7462, DEV 7463)
Safety of Laser Products
DEV Systemtechnik recommends following the governing standard of the
country where the product is operated to assure regulatory compliance and to
provide the necessary safety programs to protect the operators and other
persons who get in contact with the product.
It is recommended to power down the product while working on the optical
fiber wiring.
The optical modules installed in the product operate with light at a non-visible
wavelength. Highest caution has to be taken, since the modules may carry laser
light that is capable to harm the human eye!
If no optical fiber is (to be) connected to an optical module, the optical connector(s) have to be equipped with the appropriate protection cover(s).
Direct exposure to the beam is to be avoided, i.e. do not look into
unterminated optical ports or at fibers that connect to unknown sources.
Copyright DEV Systemtechnik GmbH 2015-2017 9
Page 10
User Manual DEV 1953
3
124
56
7
8910
11 12
13
14
15 16
Sim ul tan eou s
Re mo te
Ind ivid ua l
Loc al Au to
In A
In B
Un ive rsa l S wit ch Ch ass is
DE V 1 95 3
3
4 567
8
3 Product Description
With the DEV 1953, DEV Systemtechnik has developed a modular design principle
for a universal switch chassis. A variety of different switch modules is available that
can be installed easily in the 16 slots of the device. A selection of passive splitter
modules and of distribution amplifier modules for ASI/SDI signals is available as
well. Please refer to chapter 3.2 for the description of the single modules.
A device panel (chapter 3.1.1) permits the monitoring and the local control of the
DEV 1953. Some other methods for the control and for the surveillance of the
device are provided (chapter 3.1.2). The application of sensing switch modules and
of digital signal switch modules enables additional autonomous switching
capabilities of the DEV 1953 (chapter 3.1.3) as well as the application of the TRAC
(stands for "Trap Receiver Action Controller") option (chapter 3.1.5).
3.1 Features and Options
3.1.1 Device Panel
Aside from the device panel -which is explained in the following- the product
provides the "Reset" push button on the CPU module (please refer to chapter 3.2.24)
for restarting the device, and the two LEDs on each power supply module
(chapter 3.2.25).
The device panel occupies most of the space at the front side of the chassis:
The mode push button (3) permits the change of the operation mode (chapter 5.1)
at the device. By pressing and holding the push button for ~3 seconds the status of
the LEDs advances, i.e. always only one of the operation mode LEDs "Remote" (4),
"Local" (5), or "Auto" (6) is on.
The second functionality of the mode push button is the event acknowledgment:
If there are pending and not acknowledged event(s), this is indicated via continuous
alternate blinking of all channel LEDs. To acknowledge the event(s) (i.e. to stop the
blinking of the LEDs) at the device, the mode push button is to be operated. Thus,
three scenarios for the behavior of the mode push button are to be considered:
1. There are no pending and not acknowledged event(s):
In this case, the operation mode can be altered as described above.
2. There are pending and not acknowledged event(s) in Local Mode:
A short operation of the mode push button acknowledges the event(s) (stops
10 Copyright DEV Systemtechnik GmbH 2015-2017
the blinking of the LEDs). After that, the operation mode can be altered as
described above.
Page 11
User Manual DEV 1953
3. Pending and not acknowledged event(s) in Remote Mode (or Auto Mode):
A short operation of the mode push button acknowledges the event(s) (stops
the blinking of the LEDs) and switches the device to Local Mode. After that, the
operation mode can be altered as described above.
Note:
Usually the type of event causing the event indication via device panel can be
identified via Web Interface or via remote interface, only.
If event(s) are not acknowledged yet, the alternate blinking of all channel LEDs
is performed synchronously but according to the switching status of the device.
If an event is not acknowledged and if the event disappears (e.g. a detected
missing AC line is working again), the event indication via device panel will stop
automatically (if it is the sole event).
The event indication via device panel cannot be stopped if no switch (or
distribution amplifier) module is installed or detected within the device.
With the sixteen channel push buttons (indicated by 7 in the figure above) labeled
"1"…"16", one of the two (input) ports (primary (input) port "In A" or secondary
(input) port "In B") of a switch module can be switched to the common (output) port
in Local Mode (!). The (input) port that is currently active is indicated via the related
green channel LED.
The switching mode push button and the yellow LEDs labeled "Simultaneous" and
"Individual" (indicated by 8 in the figure above) are for the Simultaneous/Individual
switching mode functionality of the device, which is described in chapter 5.1.4.
To alter the routing of a single switch module via the related channel push button
make sure that the device is in Local Mode and that the "Individual" LED is lit. After
the operation of the desired channel push button, the LED display will indicate the
altered switching position as a receipt.
If the "Simultaneous" LED is lit (for the preconditions to activate Simultaneous
switching mode please refer to chapter 5.1.4), any of the channel push buttons of a
group can be operated to initiate the switching of the switch modules being
member of the group.
Note:
The channel push buttons (7) and the switching mode push button (8) are
enabled in Local Mode, only.
The related channel push button (7) is not functional (i.e. the LED always
indicates position "In A") if a slot is not equipped with a switch module.
3.1.2 Communication Features
In addition to the device panel there are provided some options for the monitoring
and control of the product:
The Web Interface (please refer to chapter 5.5) provides features for checking the
health status and for changing the setup of the device; it enables full control in
terms of switching and in terms of setting up specific parameters. Additionally, the
features Time Based Switching and TRAC (if installed), and -for devices with
installed sensing switch modules- the recording functionality are accessible.
The implementation of SNMP (Simple Network Management Protocol) via the
Ethernet interface is intended to serve as the standard for remote monitoring and
control of the device (chapter 5.9).
Copyright DEV Systemtechnik GmbH 2015-2017 11
Page 12
User Manual DEV 1953
In addition, a Communication Protocol Handler (CPH) is implemented which
enables the use of one of the following remote protocols with different monitoring
and control capabilities:
Sandar Prosan protocol via serial interface (chapter 5.6);
Leitch protocol via serial interface and via Ethernet interface (chapter 5.7); and
QEC protocol via serial interface and via Ethernet interface (chapter 5.8).
The installation of sensing switch modules and of digital signal switch modules
enables the autonomous switching capability (chapter 3.1.3) of the device based on
the signal quality. Moreover, the TRAC option (chapter 3.1.5) permits a remote
device to control the switching of the DEV 1953.
Finally, the digital interface options (chapter 3.1.4) feature basic remote switching
functionality permitting the control of the device.
3.1.3 Autonomous Switching and Options
Among the broad choice of other switch modules, the DEV 1953 can be equipped
with sensing switch modules and/or with digital signal switch modules.
The sensing switch modules (and the digital signal switch modules) are special since
they permit the device to switch autonomously (please refer to chapter 5.1.3)
based on the RF level information (and on the digital signal quality information,
respectively) at both input ports of the module.
By default, the DEV 1953 provides autonomous switching capability from the
primary to the secondary input port(s).
With Option 22, the DEV 1953 is delivered with the main backup swap feature, i.e.
the autonomous switching works in both directions instead of switching from the
primary to the secondary input port(s), only.
With Option 28 the DEV 1953 is delivered with the automatic switch back feature
which permits the autonomous switching in both directions as well, but with an
adjustable hysteresis (for sensing switch modules) or with an adjustable delay (for
digital signal switch modules) when switching back from the secondary to the
primary input port(s).
The Web Interface enables the adjustment of the RF threshold levels for each input
port of a sensing switch module and enables the modification of settings for the
automatic switch back option.
3.1.4 Digital Interface Options
As an option (Option 56 for 24 V and Option 57 for 12 V) the product is equipped
with a digital interface module (please refer to chapter 3.2.26), e.g. to be
connected to a PLC (Programmable Logic Control).
With this interface, it is possible to switch up to 16 channels of the device and to
obtain switching status information for each channel.
3.1.5 TRAC Option
The DEV 1953 can be equipped with the TRAC (stands for Trap Receiver Action
Controller) option (Option 37), which permits the remote controlled switching of
the product based on SNMP traps, or based on the availability or on the absence of
a remote device (IP Monitoring). For more details, please refer to chapter 5.5.7.3.5.
12 Copyright DEV Systemtechnik GmbH 2015-2017
Page 13
User Manual DEV 1953
3.1.6 Other Options
By default, the DEV 1953 is delivered with two redundant wide range AC power
supplies that are connected to separate AC lines. Option 14 permits a redundant
DC supply of the device supplied by two different lines with -36...-75 V DC input
voltage (or with +36...+75 V DC by inverting the polarity).
A single license for the Web Interface (please refer to chapter 5.5) is included in the
delivery of the product, additional licenses can be ordered initially via Option 78.
Note that it is possible to purchase additional license keys at any time, please
contact DEV Systemtechnik.
3.2 Modules Description
This paragraph points out the functionality of the modules that were designed for
the DEV 1953. There are available electrical and optical switch modules, passive
splitter modules, and distribution amplifier modules for ASI/SDI signals.
The modules described in the following can be removed, installed, and/or exchanged even during the operation of the device. Knurled head screws are provided on each module, which can be operated easily.
A short listing of the available DEV 1953 modules is provided here for reference:
3.2.1 DEV 11-0014 - DPST Sensing Switch Module; DC, 950…2150 MHz; 50 Ohm, SMA (f)
3.2.2 DEV 11–0026 - DPST Sensing Switch Module; DC, 950…2150 MHz; 75 Ohm, F (f)
3.2.3 DEV 11–0031 - DPST Switch Module with Monitor Port; 47...1006 MHz; 75 Ohm, BNC (f)
3.2.4 DEV 11–0034 - DPST Sensing Switch Module; DC, 47...1006 MHz; 75 Ohm, F (f)
3.2.5 DEV 11–0051 - DPST Switch Module; DC…2500 MHz; 50 Ohm, SMA (f)
3.2.6 DEV 11–0097 - DPST Switch Module without Monitor Port; 47...1500 MHz; 75 Ohm, BNC (f)
3.2.7 DEV 11–0102 - DPST High Power Sensing Switch Module; DC, 950…2150 MHz; 75 Ohm, F (f)
3.2.8 DEV 11–0105 - DPST High Power Sensing Switch Module; DC, 47…1006 MHz; 75 Ohm, F (f)
3.2.9 DEV 11–0110 - DPST Switch Module; DC, 47…2500 MHz; 75 Ohm, F (f)
3.2.10 DEV 13–0033 - 1:2/2:1 Splitter/Combiner Module, Passive; 950…2150 MHz; 75 Ohm, F (f)
3.2.11 DEV 13–0063 - 1:4/4:1 Splitter/Combiner Module, Passive; 950…2150 MHz; 75 Ohm, F (f)
3.2.12 DEV 13–0235 - 1:4/4:1 Splitter/Combiner Module, Passive; 47…1006 MHz; 75 Ohm, F (f)
3.2.13 DEV 13–0321 - 1:4/4:1 Splitter/Combiner Module, Passive; 47…1006 MHz; 75 Ohm, F (f)
3.2.14 DEV 14–0052 - Ethernet 2:1/1:2 Switch Module
3.2.15 DEV 14–0089 - DPST Switch Module with DA 1:3; ASI; 75 Ohm, BNC (f)
3.2.16 DEV 14–0090 - DPST Switch Module with DA 1:3; ASI / HD-SDI; 75 Ohm, BNC (f)
3.2.17 DEV 14–0092 - Distribution Amplifier 1:3; ASI; 75 Ohm, BNC (f)
3.2.18 DEV 14–0094 - DPST Switch Module with DA 1:3; ASI / 3G-SDI; 75 Ohm, BNC (f)
3.2.19 DEV 14–0096 - Distribution Amplifier 1:3; ASI / 3G-SDI; 75 Ohm, BNC (f)
3.2.20 DEV 14–0103 - Distribution Amplifier 1:3; ASI / HD-SDI; 75 Ohm, BNC (f)
3.2.21 DEV 14–0111 - DPST Switch Module with DA 1:3; E1/T1; 75 Ohm, BNC (f)
Two input ports ("In A", "In B") can be switched to one output port ("Out"). The
unused input port is terminated internally. The module is able to pass an external
10 MHz reference signal.
The module provides RF level monitoring, i.e. the RF level of both input ports is
measured and is compared with (adjustable) RF threshold levels. This enables the
event indication functionality with respect to the present input signal levels, and/or
permits the DEV 1953 to control the switching autonomously.
The functionality of the module DEV 11-0026 is identical with the module
DEV 11-0014 (please refer to chapter 3.2.1), but the module is designed for 75 Ohm
with F connectors (instead of 50 Ohm with SMA connectors).
The output port ("Out") can be switched to one of two input ports ("In A", "In B"). The
unused input port is terminated internally. The transmission is DC blocked. Failsafe
relays are used for switching. In the case of power loss, the primary input port
("In A") is routed to the output port. For measurement purposes, the monitoring
output port ("Monitor") is available.
The functionality of the module DEV 11-0034 is identical with the module
DEV 11-0014 (please refer to chapter 3.2.1), but the module is designed for a
different frequency range and for 75 Ohm with F connectors (instead of 50 Ohm
with SMA connectors).
Copyright DEV Systemtechnik GmbH 2015-2017 15
Page 16
User Manual DEV 1953
In A
In B
Out
1
3
2
In A
Ou t
In B
DE V 11 -00 51
In A
In B
Out
1
3
2
In B
Ou t
In A
DE V 11 -00 97
3.2.5DEV 11-0051
DPST Switch Module; DC…2500 MHz; 50 Ohm, SMA (f)
The common port ("Out") can be switched to one of two input/output ports ("In A",
"In B"). The unused input/output port is terminated internally. Latching relays are
used for switching.
The functionality of the module DEV 11-0097 is identical with the module
DEV 11-0031 (please refer to chapter 3.2.3), but without a monitor port thus
enabling an extended frequency range.
16 Copyright DEV Systemtechnik GmbH 2015-2017
Page 17
User Manual DEV 1953
Out
In A
In B
Lo gic
External
Contro ller
2
3
1
In A
Ou t
In B
DE V 11 -01 02
Out
In A
In B
Lo gic
External
Contro ller
2
3
1
In A
Ou t
In B
DE V 11 -01 05
3.2.7DEV 11-0102
DPST High Power Sensing Switch Module; DC, 950…2150 MHz; 75 Ohm, F (f)
The functionality of the module DEV 11-0102 is identical with the module
DEV 11-0014 (please refer to chapter 3.2.1), but the module is designed for high
power signals and for 75 Ohm with F connectors (instead of 50 Ohm with SMA
connectors).
3.2.8 DEV 11-0105
DPST High Power Sensing Switch Module; DC, 47…1006 MHz; 75 Ohm, F (f)
The functionality of the module DEV 11-0105 is identical with the module
DEV 11-0014 (please refer to chapter 3.2.1), but the module is designed for high
power signals, for a different frequency range, and for 75 Ohm with F connectors
(instead of 50 Ohm with SMA connectors).
Copyright DEV Systemtechnik GmbH 2015-2017 17
Page 18
User Manual DEV 1953
In A
In B
Out
2
3
1
In A
Ou t
In B
DE V 11 -01 10
1
3
2
In
Out 1
Out 2
In
Ou t 1
Ou t 2
DE V 13 -00 33
3.2.9DEV 11-0110
DPST Switch Module; DC, 47…2500 MHz; 75 Ohm, F (f)
The common port ("Out") can be switched to one of two input/output ports ("In A",
"In B"). The unused input/output port is terminated internally. The module is able to
pass an external 10 MHz reference signal.
3.2.10 DEV 13-0033
1:2/2:1 Splitter/Combiner Module, Passive; 950…2150 MHz; 75 Ohm, F (f)
This passive module for splitting or for combining RF signals can be installed in a
DEV 1953 as a supplemental module.
18 Copyright DEV Systemtechnik GmbH 2015-2017
Page 19
User Manual DEV 1953
1
5
4
In
Out 1
Out 2
Out 3
Out 4
3
2
DE V 13 -00 63
Ou t 1
Ou t 2
In
Ou t 3
Ou t 4
1
5
4
In
Out 1
Out 2
Out 3
Out 4
3
2
DE V 13 -02 35
Ou t 1
Ou t 2
In
Ou t 3
Ou t 4
3.2.11 DEV 13-0063
1:4/4:1 Splitter/Combiner Module, Passive; 950…2150 MHz; 75 Ohm, F (f)
This passive module for splitting or for combining RF signals can be installed in a
DEV 1953 as a supplemental module.
3.2.12 DEV 13-0235
1:4/4:1 Splitter/Combiner Module, Passive; 47…1006 MHz; 75 Ohm, F (f)
This passive module for splitting or for combining RF signals can be installed in a
DEV 1953 as a supplemental module.
Copyright DEV Systemtechnik GmbH 2015-2017 19
Page 20
User Manual DEV 1953
1
5
4
In
Out 1
Out 2
Out 3
Out 4
3
2
Ou t 1
Ou t 2
In
Ou t 3
Ou t 4
DE V 13 -03 21
1:1 Pa tc h C ab le
1
8
LA N 1
LA N 2
WAN
1:1 Pa tc h C ab le
1:1 Pa tc h C ab le
1
8
1
8
8
1
8
1
8
1
1
2
3
DE V 14 -00 52
LA N 1
WA N
LA N 2
3.2.13 DEV 13-0321
1:4/4:1 Splitter/Combiner Module, Passive; 950…2150 MHz; 50 Ohm, SMA (f)
This passive module for splitting or for combining RF signals can be installed in a
DEV 1953 as a supplemental module.
3.2.14 DEV 14-0052
Ethernet 2:1/1:2 Switch Module
The module is designed for Ethernet switching applications and is equipped with
three RJ-45 Ethernet connectors in order to select physically one of two routes.
20 Copyright DEV Systemtechnik GmbH 2015-2017
Page 21
User Manual DEV 1953
In B
Ou t 3
Po sitio n 0: w itho ut e le ctric al pow er
Po sitio n 1: w ith elec trica l p owe r In A s elec te d
Po sitio n 2: w ith elec trica l p owe r In B s elec te d
(st ate sh own h er e)
1
2
4
5
Ou t 2
Ou t 1
1,2
02
0,1
0,1
0,1
2
2
0
1,2
Ex te rn al
Co ntro lle r
Lo gic
C
D
D
C
In A
3
DE V 14 -00 89
In A
In B
Ou t 1
Ou t 2
Ou t 3
In B
Ou t 3
Po sitio n 0: w itho ut e le ctric al pow er
Po sitio n 1: w ith elec trica l p owe r In A s elec te d
Po sitio n 2: w ith elec trica l p owe r In B s elec te d
(st ate sh own h er e)
1
2
4
5
Ou t 2
Ou t 1
1,2
02
0,1
0,1
0,1
2
2
0
1,2
Ex te rn al
Co ntro lle r
Lo gic
C
D
D
C
In A
3
DE V 14 -00 90
In A
In B
Ou t 1
Ou t 2
Ou t 3
3.2.15 DEV 14-0089
DPST Switch Module with DA 1:3; ASI; 75 Ohm, BNC (f)
The module is designed for ASI signal applications. Normally one of the two input
signals is routed to the three separately amplified output ports. In the case of
power loss, the primary input port ("In A") is routed only to the first output port
("Out 1") and the other output ports do not carry any signal.
The unused input port is terminated internally. Electronic switches and a failsafe
relay are used for switching.
3.2.16 DEV 14-0090
DPST Switch Module with DA 1:3; ASI / HD-SDI; 75 Ohm, BNC (f)
The functionality of the module DEV 14-0090 is identical with the module
DEV 14-0089 (please refer to chapter 3.2.15), but the module is designed for
SD-SDI and HD-SDI signals in addition to ASI signals.
Note:
Output port 1 ("Out 1") delivers an inverted ASI signal!
Copyright DEV Systemtechnik GmbH 2015-2017 21
Page 22
User Manual DEV 1953
1
3
4
Out 1
Po s 0: w itho ut e le ctric al pow er
Po s 1: w ith elec trica l p ower
(st ate sh ow n h er e)
Out 2
In
Out 2
Ex te rn al
Co ntro lle r
Lo gic
CD
1
00
1
2
Ou t 1
Ou t 2
Ou t 3
In
DE V 14 -00 92
In B
Ou t 3
Po sitio n 0: w itho ut e le ctric al pow er
Po sitio n 1: w ith elec trica l p owe r In A s elec te d
Po sitio n 2: w ith elec trica l p owe r In B s elec te d
(st ate sh own h er e)
1
2
4
5
Ou t 2
Ou t 1
1,2
02
0,1
0,1
0,1
2
2
0
1,2
Ex te rn al
Co ntro lle r
Lo gic
C
D
D
C
In A
3
DE V 14 -00 94
In A
In B
Ou t 1
Ou t 2
Ou t 3
3.2.17 DEV 14-0092
Distribution Amplifier 1:3; ASI; 75 Ohm, BNC (f)
The module is designed to distribute and to amplify ASI signals. Normally the input
signal is routed to the three separately amplified output ports. In the case of power
loss, the input signal is routed only to the first output port ("Out 1") and the other
output ports do not carry any signal.
3.2.18 DEV 14-0094
DPST Switch Module with DA 1:3; ASI / 3G-SDI; 75 Ohm, BNC (f)
The functionality of the module DEV 14-0094 is identical with the module
DEV 14-0089 (please refer to chapter 3.2.15), but the module is designed for
SD-SDI, HD-SDI, and 3G-SDI signals in addition to ASI signals.
Note:
Output port 1 ("Out 1") delivers an inverted ASI signal!
22 Copyright DEV Systemtechnik GmbH 2015-2017
Page 23
User Manual DEV 1953
1
3
4
Out 1
Po s 0: w itho ut e le ctric al pow er
Po s 1: w ith elec trica l p ower
(st ate sh ow n h er e)
Out 2
In
Out 2
Ex te rn al
Co ntro lle r
Lo gic
CD
1
00
1
2
Ou t 1
Ou t 2
Ou t 3
In
DE V 14 -00 96
1
3
4
Out 1
Po s 0: w itho ut e le ctric al pow er
Po s 1: w ith elec trica l p ower
(st ate sh ow n h er e)
Out 2
In
Out 2
Ex te rn al
Co ntro lle r
Lo gic
CD
1
00
1
2
Ou t 1
Ou t 2
Ou t 3
In
DE V 14 -01 03
3.2.19 DEV 14-0096
Distribution Amplifier 1:3; ASI / 3G-SDI; 75 Ohm, BNC (f)
The functionality of the module DEV 14-0096 is identical with the module
DEV 14-0092 (please refer to chapter 3.2.17), but the module is designed for
SD-SDI, HD-SDI, and 3G-SDI signals in addition to ASI signals.
Note:
Output port 1 ("Out 1") delivers an inverted ASI signal!
3.2.20 DEV 14-0103
Distribution Amplifier 1:3; ASI / HD-SDI; 75 Ohm, BNC (f)
The functionality of the module DEV 14-0103 is identical with the module
DEV 14-0092 (please refer to chapter 3.2.17), but the module is designed for
SD-SDI and HD-SDI signals in addition to ASI signals.
Note:
Output port 1 ("Out 1") delivers an inverted ASI signal!
Copyright DEV Systemtechnik GmbH 2015-2017 23
Page 24
User Manual DEV 1953
Out 1
Po s 0: w itho ut e le ctric al pow er
Po s 1: w ith elec trica l p ower In A s elec te d
Po s 2: w ith elec trica l p ower In B s elec te d
Out 2
In A
In B
Out 3
Ex te rn al
Co ntro lle r
Lo gic
CD
CD
1,2
00
1,2
2
1
Sw itch
Lo gic
1
2
4
5
3
In A
In B
Ou t 1
Ou t 2
Ou t 3
DE V 14 -01 11
1
2
C
Optical S w itch
Op tic al Fib er
Ex te rn al
Co ntro lle r
Lo gic
Op tic al Fib er
Op tic al Fib er
3
1
2
C
1
2
DE V 74 62
3.2.21 DEV 14-0111
DPST Switch Module with DA 1:3; E1/T1; 75 Ohm, BNC (f)
The module is designed for E1 or T1 signal applications. Normally one of the two
input signals is routed to the three separately amplified output ports. In the case of
power loss, the primary input port ("In A") is routed only to the first output port
("Out 1") and the other output ports do not carry any signal.
The unused input port is terminated internally.
The module is a 2:1 switch for optical signals. The optical common port ("Com") can
be switched to one of the two optical input/output ports ("A", "B"). The module is
shown here with the E2000 HRL connector option; other optical connector types
are available alternatively.
24 Copyright DEV Systemtechnik GmbH 2015-2017
Page 25
User Manual DEV 1953
1
2
C
Optical S w itch
Op tic al Fib er
Ex te rn al
Co ntro lle r
Lo gic
Op tic al Fib er
Op tic al Fib er
3
1
2
C
1
2
DE V 74 63
4
3
2
1
Co m
Ethe rn et
Re set
3.2.23 DEV 7463
1:2 Optribution® Switch; 1260…1610 nm; SC/APC
The functionality of the DEV 7463 (here shown with the FC/APC connector option)
is identical with the DEV 7462 (please refer to chapter 3.2.22), but the module is
designed for a different optical wavelength range.
3.2.24 CPU Module
The CPU module of the DEV 1953 is located at the rear side of the chassis and
manages the monitoring and the control functionality of the device.
"Reset" push button (1):
Normally the "Reset" push button is not to be operated at all. It is to be actuated
only in case that the configuration of the device was changed, or in the very
rare cases that the remote communication/operation does not behave
normally or does not work any longer. The reset of the CPU module is
Copyright DEV Systemtechnik GmbH 2015-2017 25
described in chapter 4.2.6.
"Ethernet" connector (2):
This interface is used for the communication via Web Interface, and/or for
operation via SNMP, and/or for operation via Leitch protocol or via QEC
protocol; please refer to chapter 4.4.2.
Page 26
User Manual DEV 1953
Po wer S up ply
Op eratio n
Fa ilu re
12 -00 15
Po wer S up ply
Op eratio n
Fa ilu re
12 -00 22
M&C 1
"Com" connector for the serial interface (3):
This interface can be used for the basic network setup of the device and it
supports the communication via Sandar Prosan protocol, or via Leitch protocol,
or via QEC protocol (chapter 4.4.1).
Extraction lever (4):
This lever simplifies the exchange of the CPU module (chapter 4.2.5).
3.2.25 Power Supply Modules
The DEV 1953 is usually equipped with two hot-pluggable redundant wide range AC
power supply modules supplied by two different AC lines. If the device was ordered
with Option 14, two DC power supplies are installed, instead.
Each power supply module provides a green LED indicating the proper "Operation" of
the module and a red LED indicating a "Failure" of the module.
3.2.26 Digital Interface Modules
If the product is ordered with one of the digital interface options (Option 56 for
24 V or Option 57 for 12 V), a digital interface module is installed, usually located at
the rear side of the chassis right to the power inlets. Please refer to chapter 5.4 for
the operation via the digital interface and to chapter 7 for the pin assignment and
for the technical details.
26 Copyright DEV Systemtechnik GmbH 2015-2017
Page 27
User Manual DEV 1953
12
Pow er Sup ply
Ope rat ion
Fail ure
12-0 022
Pow er Sup ply
Ope rat ion
Fail ure
12-0 022
3
1 24
5 6
7
8 9 10
11 12
13
14
15 16
Sim ulta neo us
Rem ote
Indi vidu al
Loc al Auto
In A
In B
Uni vers al S wit ch Cha ssis
DEV 19 53
3
4 567
8
12
Pow er Sup ply
Ope rat ion
Fail ure
12-0 015
Pow er Sup ply
Ope rat ion
Fail ure
12-0 015
3
1 24
5 6
7
8 9 10
11 12
13
14
15 16
Sim ulta neo us
Rem ote
Indi vidu al
Loc al Auto
In A
In B
Uni vers al S wit ch Cha ssis
DEV 19 53
3
4 567
8
1
Power supply module 1
2
Power supply module 2
3
Mode push button
4
Yellow LED indicating "Remote" Mode
5
Yellow LED indicating "Local" Mode
6
Yellow LED indicating "Auto" Mode
7
Channel push buttons "1"…"16" with green LEDs indicating "In A" or "In B"
8
Switching mode push button and yellow LEDs "Simultaneous" & "Individual"
3.3 Product Drawings
The front side of the DEV 1953 is identical for all product configurations. Just if the
product was ordered with Option 14, different power supply modules are installed.
The rear side of the DEV 1953 differs with respect to the installed module types and
quantities. Thus, only three drawings of the rear side are provided, other product
configurations can be easily derived.
3.3.1 Front Side DEV 1953
Front View (AC/DC Power Supplies, standard):
Front View (DC/DC Power Supplies, Option 14):
Copyright DEV Systemtechnik GmbH 2015-2017 27
Page 28
User Manual DEV 1953
213
45P
C
100 ...2 40 V
Disc onn ect pow er
WA R NI NG :
befo re o pen ing!
50.. .60 Hz
50 V A
Sup ply 1 - Fus e 2 A T
Sup ply 2 - Fus e 2 A T
Com
Eth erne t
Res et
In B
Mon itor
Out
In A
DEV 11- 0031 D EV 1 4-00 89
In A
In B
Out 1
Out 2
Out 3
DEV 14- 0094
In A
In B
Out 1
Out 2
Out 3
In A
Out
In B
DEV 11- 0014
C
1
2
DEV 746 2
1
Slot 1 equipped with DEV 11-0031
2
Slot 2 equipped with DEV 14-0089
3
Slot 3 equipped with DEV 14-0094
4
Slot 4 equipped with DEV 11-0014
5
Slot 5 equipped with DEV 7462 with standard SC/APC connectors
C
CPU module
P
Grounding bolt and AC power plugs
213
45
6
7
89 10 11 12
P
C
Sup ply 1 - Fus e 4 A T
-36. ..-7 2 V DC or
Disc onn ect pow er
WA R NI NG :
befo re o pen ing!
+36 ...+ 72 V DC
100 W
Sup ply 2 - Fus e 4 A T
Com
Eth erne t
Res et
In A
Out
In B
DEV 11- 0026
In A
Out
In B
DEV 11- 0026
In A
Out
In B
DEV 11- 0026
In A
Out
In B
DEV 11- 0026
In
Out 1
Out 2
DEV 13- 0033
In
Out 1
Out 2
DEV 13- 0033
In
Out 1
Out 2
DEV 13- 0033
In
Out 1
Out 2
DEV 13- 0033 D EV 1 3-0 235
Out 1
Out 2
In
Out 3
Out 4
DEV 13- 0235
Out 1
Out 2
In
Out 3
Out 4
DEV 13- 0235
Out 1
Out 2
In
Out 3
Out 4
DEV 13- 0235
Out 1
Out 2
In
Out 3
Out 4
1…4
Slots 1…4 equipped with DEV 11-0026
5…8
Slots 5…8 equipped with DEV 13-0033
9…12
Slots 9…12 equipped with DEV 13-0235
C
CPU module
P
Grounding bolt and DC power plugs (Option 14)
3.3.2 Rear Side DEV 1953 with 5 Modules (Demo Application)
Rear View:
3.3.3 Rear Side DEV 1953 with 12 Modules (RF Switching Application)
Rear View:
28 Copyright DEV Systemtechnik GmbH 2015-2017
Page 29
User Manual DEV 1953
213
45
6
7
89 10 11 12 13 14 15 16
P
C
100 ...2 40 V
Dis con nec t po wer
WA R NI NG :
befo re ope ning !
50.. .60 Hz
50 V A
Sup ply 2 - Fus e 2 A T
Sup ply 1 - Fus e 2 A T
M& C 1
Com
Eth erne t
Res et
DEV 14- 0089
In A
In B
Out 1
Out 2
Out 3
DEV 14- 0089
In A
In B
Out 1
Out 2
Out 3
DEV 14- 0089
In A
In B
Out 1
Out 2
Out 3
DEV 14- 0089
In A
In B
Out 1
Out 2
Out 3
In B
Mon itor
Out
In A
DEV 11- 0031
In B
Mon itor
Out
In A
DEV 11- 0031
In B
Mon itor
Out
In A
DEV 11- 0031
In B
Mon itor
Out
In A
DEV 11- 0031 D EV 1 4-00 94
In A
In B
Out 1
Out 2
Out 3
DEV 14- 0094
In A
In B
Out 1
Out 2
Out 3
DEV 14- 0094
In A
In B
Out 1
Out 2
Out 3
DEV 14- 0094
In A
In B
Out 1
Out 2
Out 3
In B
Mon itor
Out
In A
DEV 11- 0031
In B
Mon itor
Out
In A
DEV 11- 0031
In B
Mon itor
Out
In A
DEV 11- 0031
In B
Mon itor
Out
In A
DEV 11- 0031
1…4
Slots 1…4 equipped with DEV 14-0089
5…8
Slots 5…8 equipped with DEV 11-0031
9…12
Slots 9…12 equipped with DEV 14-0094
13…16
Slots 13…16 equipped with DEV 11-0031
C
CPU module
P
Grounding bolt, AC power plugs, and digital interface module (Option 56 or Option 57)
3.3.4 Rear Side DEV 1953 with 16 Modules (Digital Switching Application)
Rear View:
4 Installation Instructions
4.1 Scope of Delivery
1 * DEV 1953 equipped with switch modules, distribution amplifier modules,
splitter modules, and other options,
as ordered
1 * User Manual (this document)
4.2 Installation of the Product
4.2.1 Mechanical Assembly
Please refer to the warnings in chapter 2.3 regarding the mechanical integration of
the product. For the integration in a 19" rack, the rack slots must be prepared with
rails for the chassis. After inserting the chassis in the rack, fix the chassis with four
screws to the rack at its rack mount flanges.
4.2.2 Grounding, Data Cables, and Power Connection
For the warnings with respect to "Grounding, AC Connection, Cables" please refer
to chapter 2.3.
The chassis needs to be connected to the 19" rack via a ground wire. The grounding
bolt (labeled 1 in the figures below) is located on the right at the rear side of the
product.
Take off the upper nut and the first washer of the grounding bolt and connect the
grounding cable, which must have a ring tongue terminal matching for the M4
fastening bolt. After that, the washer and the nut have to be tightened again.
Copyright DEV Systemtechnik GmbH 2015-2017 29
Page 30
User Manual DEV 1953
1
5
7
4
6
1
8
6
4
7
5
3
2
Standard
plus Option 56 (or 57)
Co m
Ethe rn et
Re set
10 0. ..2 40 V
Discon ne ct po w er
WARN ING:
be fore op en in g!
50 ...60 H z
50 V A
Su pply 1 - Fus e 2 A T
Su pply 2 - Fus e 2 A T
10 0. ..2 40 V
Discon nec t p owe r
WARN ING:
be fore ope ning !
50 ...60 H z
50 V A
Su pply 2 - Fus e 2 A T
Su pply 1 - Fus e 2 A T
M&C 1
1
5
7
4
6
1
8
6
4
7
5
3
2
Option 14
plus Option 56 (or 57)
Co m
Ethe rn et
Re set
Su pply 1 - Fus e 4 A T
-36... -7 2 V DC or
Discon ne ct po w er
WARN ING:
be fore op en in g!
+3 6. ..+ 72 V DC
10 0 W
Su pply 2 - Fus e 4 A T
Discon nec t p owe r
WARN ING:
be fore ope ning !
M&C 1
Su pply 1 - Fus e 4 A T
Su pply 2 - Fus e 4 A T
-36... -7 2 V DC or
+3 6. ..+ 72 V DC
10 0 W
Next, establish the external Ethernet connection by plugging an Ethernet cable
from your network to the "Ethernet" (3) of the CPU module.
If the basic network setup via serial interface is required (please refer to chapter
4.4.2.2), and/or if it is intended to control the device via the serial interface using
Sandar Prosan protocol, Leitch protocol, or QEC protocol, a serial connection
between a PC and the serial connector of the CPU module labeled "Com" (2) is to be
established. The configuration of the serial interface is described in chapter 4.4.1;
please refer to chapter 7 for the pin assignment of the serial connector.
If the device is equipped with a digital interface module (Option 56 or Option 57)
and if it is intended to control the DEV 1953 via the digital interface, connect a prepared cable to (8). The pin assignment of the digital interface module connector is
stated in chapter 7.
30 Copyright DEV Systemtechnik GmbH 2015-2017
Page 31
User Manual DEV 1953
Finally, connect two power cords to the primary connectors (4 & 5). It is recommended to use two separately fused phases of the available electrical outlets. If the
device was ordered with Option 14, the power cables have to be prepared. The
matching connectors are part of the delivery; the pin assignment is stated in
chapter 7.
Note:
It is highly recommended to power up the device after the installation of the
modules (chapter 4.2.5) and after the connection of all signal cables (chapters
4.2.3 & 4.2.4).
The power lines are fused separately; the fuse holders (6 & 7) are located
below the related power inlet (4 & 5). If a fuse has to be exchanged, unplug the
device completely and use 2 A T 5*20 mm glass fuses (4 A T 5*20 mm glass
fuses for devices with Option 14) for replacement only!
4.2.3 Connection of Optical Signal Cables
Only if the DEV 1953 is equipped with optical switch modules DEV 7462 and/or
DEV 7463, optical fibers have to be connected to the installed optical modules.
Please refer to the laser safety warnings stated in chapter 2.3!
If applicable, apply strain relieves to the optical fibers which are to be connected to
the installed optical modules in a way, that the connectors of the optical modules
are not stressed mechanically.
Sequentially, remove each optical connector protection cover at the device, and
plug in and tighten the corresponding connector from the optical fiber bundle(s).
Note:
The optical modules are available with different optical connector types, i.e.
FC/APC, E2000 HRL, or SC/APC.
Make sure, that the matching connectors are installed in the application.
4.2.4 Connection of RF Signal Cables
Apply strain relieves to the external RF signal cables which are to be connected in a
way, that the connectors of the device are not stressed mechanically.
When connecting RF cables to the installed modules, each connector providing a
thread is to be tightened with a torque wrench. For 75 Ohm F connectors the
applied torque should not exceed 4.5 Nm (39.8 lbf-in). In case of 50 Ohm
SMA connectors a torque wrench adjusted to 1 Nm (8.85 lbf-in) is to be used. If a
module is equipped with BNC connectors, make sure that the bayonet of each RF
connection is locked.
Note:
For 75 Ohm RF connectors, either female 75 Ohm BNC connectors or female
precision F connectors are applied. Make sure, that the applied connectors are
male 75 Ohm BNC connectors or male precision F connectors (with thin inner
conductor).
Each unused output port of a passive splitter module or of a distribution
amplifier module is to be terminated with an appropriate load (i.e. 50 Ohm
SMA (m), 75 Ohm F (m), or 75 Ohm BNC (m)) to achieve best amplitude
frequency response.
If all cables are connected, the device can be powered up.
Copyright DEV Systemtechnik GmbH 2015-2017 31
Page 32
User Manual DEV 1953
4.2.5 Installation and Exchange of Modules
The product is usually delivered with the ordered modules, which are already
installed. Therefore, you may proceed in reading the next chapter.
In case that a module has to be exchanged or if the DEV 1953 is to be upgraded
with additional module(s), the following instructions are to be noticed.
Note:
"Modules" which are assembled using regular Torx screws are to be treated by
DEV Systemtechnik, only.
Though the exchangeable modules are hot pluggable, it is recommended to
power down the device for exchange operations to avoid short circuits and for
safety reasons. There may be situations where a longer lasting interruption of
the signal transmission is not permitted, so -for instance- an exchange of a
power supply module has to be performed while the device is powered up. In
this situation, the operations as described below can be performed without
problems, but have to be carried out with the utmost caution.
After removing, adding, or exchanging a switch module (or a distribution
amplifier module) while the device is powered up, the DEV 1953 has to be
restarted to update the CPU module regarding the applied changes.
This can be done without interruption of the signal transmission.
If exchanging or installing optical modules, please especially refer to the
warnings regarding laser safety stated in chapter 2.3.
If the CPU module is to be exchanged, the Micro-SD card of the old CPU module
is to be inserted in the exchange CPU module.
The CPU module provides a push down lever to simplify the extraction of the
module (please refer to chapter 3.2.24).
Note that in rare cases the insertion of a module may cause an automatic
device reset.
The device is to be equipped with at least one switch module (or one
distribution amplifier module). If not a single switch (or distribution amplifier)
module is installed or detected, the device signalizes this by a permanent event
indication (i.e. the channel LEDs at the device panel are blinking and this cannot
be stopped).
Removal of a module:
Any cable attached to the front side of the module is to be disconnected it in the
first step. For the removal unscrew the (all) knurled head screw(s) of the module
(or of the blind plate) before gently pulling out the module completely (or before
taking off the blind plate).
Installation of a module:
In the first step, plug in the module by inserting it into the two card guides of the
desired slot and by gently pushing the module into the chassis that it levels with the
rear side of the device. Screw in the (all) knurled head screw(s) of the module, next.
Finally, (re-)connect the corresponding cables to the module.
32 Copyright DEV Systemtechnik GmbH 2015-2017
Page 33
User Manual DEV 1953
4.2.5.1 Exchange of the Micro-SD Card and Backup of the Configuration Data
If the Micro-SD card of the device needs to be exchanged, the following steps are
to be performed in order to transfer the configuration of the device to the new
Micro-SD card.
For an external backup of the device configuration data, only the first two steps
need to be executed:
1. Using the data backup functionality (please refer to chapter 5.5.7.4.2) of the
Web Interface to perform a backup of the "Module Data" and of the "Device
Data" (to different slots/lines!).
2. Use the button of the data backup functionality for the external storage
of both backup sets ("Module Data" and "Device Data").
3. Considering the instructions of chapter 4.2.5 to remove the CPU module,
exchange the Micro-SD card, install the CPU module, power up the device, and
login to the Web Interface (chapter 5.5.1) again using the factory network
settings (chapter 4.3.3, considering chapter 4.4.2.1).
4. Using the button of the data backup functionality to import the
externally stored "Module Data" backup set and "Device Data" backup set
(to different slots/lines!).
5. To apply the imported backup sets to the device, the button is to be
used now for the imported "Module Data" and for the imported "Device Data".
Check the data categories/settings that are to be restored (usually all of them)
before operating the button.
Note:
Since the device provides numerous parameters and settings it is generally
recommended to perform the first two steps described above after the installation of the device is completed, after major changes on the settings, and
before updating the device firmware.
4.2.6 Reset of the Device and the Restore of Factory Defaults
During power-up or after a restart the CPU module performs a health check and
scans the assemblies of the device, e.g. to detect whether a module is installed in a
slot or not. If there is a module installed, the settings for this slot are transferred to
the module. This implies that a reset is necessary only if changes on the modules
population of the device were performed or if there were applied elementary
changes, e.g. restoring the factory defaults via the Web Interface.
A device reset can be performed in three different ways:
1. Reset via the "Reset" push button (please refer to chapter 3.2.24):
Press and hold (e.g. by using a ballpoint pen) the "Reset" push button of the CPU
module for approximately three seconds.
2. Reset via the serial interface when terminating the configuration program
(chapter 4.4.2.2.1).
3. Reset via Web Interface (chapter 5.5.7.4.3).
Note:
It takes about 60 seconds after a device reset or after a power cycle that the
device is completely accessible again via the device panel, via the (optional)
digital interface, via the serial interface, via Web Interface, and via the different
remote protocols, e.g. via SNMP.
Copyright DEV Systemtechnik GmbH 2015-2017 33
Page 34
User Manual DEV 1953
If the Web Interface does not react after a restart, then the ARP (Address Reso-
lution Protocol) cache of your computer may have to be cleared by opening a
command window and by typing: "arp –d<CR>" (<CR> stands for hitting the "Enter"
or "" key on the keyboard).
If –for any reason– neither a reset nor a power cycle of the device restores all
functionality, a reset to factory defaults is to be considered:
Usually, the factory settings (chapter 4.3) can be restored via Web Interface
(chapter 5.5.7.4.1). If the device is not accessible via Web Interface, the factory
settings can be applied in the following manner:
Press and hold the "Reset" push button of the CPU module e.g. by using a
ballpoint pen.
The yellow LED on the "Ethernet" connector of the CPU module starts to blink
after ~20…50 seconds, indicating that the "Reset" button can be released.
Now a reset follows resulting in a device with restored factory settings.
4.3 Device Factory Settings
The product is delivered with factory settings as described in the following.
It is possible to restore these settings, please refer to chapter 4.2.6.
4.3.1 Factory Settings for Sensing Switch Modules
All sensing switch modules provide RF level monitoring functionality. I.e. for both
input ports, the aggregated signal power level of the RF signal is measured and
compared with an RF threshold level. If the RF level is below the RF threshold level,
an event is triggered which is indicated e.g. via Web Interface. The factory setting
for the RF threshold level for each input port of a sensing switch module depends
on the lower limit of the applied sensing switch module:
RF threshold level: (20 dB above lower limit)
For example, if the lower limit is -50 dBm, the factory setting for the RF threshold
level is -30 dBm. The RF threshold level can be adjusted for each input port via the
Web Interface (please refer to chapter 5.5.4.2) or via SNMP (chapter 5.9.4.3.9.6) in
a range which depends on the applied sensing switch module.
Note that if an exchange module is inserted in a slot of the DEV 1953, the new
module inherits the stored settings of this slot (after a device reset).
4.3.2 Factory Communication Protocol Configuration
The factory setting for the Communication Protocol Handler (CPH) is the Leitch
protocol, i.e. the serial interface configuration are the standard serial interface
configuration settings, please refer to chapter 4.4.1.1.
Chapter 5.5.7.2.3 describes the change of the protocol assignment.
For changing the network setup, please refer to chapters 4.4.2.2 & 5.5.7.2.1.
34 Copyright DEV Systemtechnik GmbH 2015-2017
Page 35
User Manual DEV 1953
4.3.4 Factory SNMP Settings
The factory SNMP settings are configured as follows:
Read Community: public
Write Community: private
Local/Remote changeable via SNMP:
Additionally, the default community for all four Trap Destination IP Addresses is set
to public and all configurable traps are disabled. If an address is defined without
explicit port assignment, the standard SNMP trap port 162 is assigned implicitly.
For changing the SNMP setup, please refer to chapter 5.5.7.2.2.
There are software factory defaults for some SNMP objects, please refer to the
corresponding chapters:
By default, the setting "Echo in Local Mode" is disabled. I.e. if the device is in Local
Mode, it does not respond to any Sandar Prosan command; please refer to chapter
5.6.1. This setting can be changed by issuing the Sandar Prosan command PME1
(chapter 5.6.3.7) or via Web Interface (chapter 5.5.7.2.3).
4.3.6 Factory Leitch Protocol Settings
By default, the setting "Echo in Local Mode" is disabled. I.e. in Local Mode, the
device responds with the Leitch Error Message to any valid Leitch command.
Furthermore the setting "Individual Switch Level Assignment" is enabled by default,
please refer to chapter 5.7.1. Both settings can be changed via Web Interface
(chapter 5.5.7.2.3).
4.3.7 Factory QEC Protocol Settings
The factory setting for the QEC serial address is 0x11 (decimal: 17).
Chapter 5.5.7.2.3 describes the change of this setting.
4.4 Communication Interface Configuration
Aside of the optional digital interface module that permits the switching via dry
contacts, two hardware interfaces are provided at the CPU module for the
communication with the device: a serial interface and an Ethernet interface.
The serial interface can be used for the basic network setup and for the operation
via Sandar Prosan protocol, or via Leitch protocol, or via QEC protocol.
The Ethernet interface is used for the operation via Web Interface, via SNMP, and
via Leitch protocol or via QEC protocol through Telnet.
4.4.1 Serial Interface
The Sub-D 9 pos female connector labeled "Com" for the standard (3 wire) RS 232
interface is located at the CPU module; the pin assignment is stated in chapter 7.
The serial interface of the device supports different remote protocols defined by
the CPH configuration. The default protocol assignment of the serial interface is
Copyright DEV Systemtechnik GmbH 2015-2017 35
Page 36
User Manual DEV 1953
subject of chapter 4.3.2. The protocol assignment can be changed via Web Interface (chapter 5.5.7.2.3); there it is possible to deselect any CPH support as well.
4.4.1.1 Standard Serial Interface Configuration
The standard serial interface configuration is applied if the device is configured to
support none of the available CPH protocols (i.e. to support the network setup via
serial interface, only) or if the device is configured to support the Leitch protocol or
the QEC protocol. The standard serial interface configuration is described by the
following parameters:
4.4.1.2 Sandar Prosan Protocol Serial Interface Configuration
The Sandar Prosan protocol serial interface configuration is applied if the device is
configured to support the Sandar Prosan protocol. The Sandar Prosan protocol
serial interface configuration is described by the following parameters:
The connector labeled "Ethernet" at the CPU module is an RJ-45 jack for the standard
100Base-TX Ethernet interface; chapter 7 describes the pin assignment.
4.4.2.1 Ethernet Connection
If a standalone device is to be connected to a PC only, the connection can be established via a direct Ethernet cable (or through a local hub/switch) between the
Ethernet connector of the device and the Ethernet connector of the PC. The network setup of the PC is to be altered that it is in the same subnet as the device. If it
is intended to use the factory network settings, the IP address of the standalone PC
is to be set to 192.168.0.x, with x in the range 1…254, except 11, which is the address of
the device, e.g. set the IP address of the standalone PC to the default gateway
address 192.168.0.99.
If the device is to be connected to the local network, make sure to change the network setup as required. Ask your network administrator for the details on network
parameters which are to be used.
The factory network settings are subject of chapter 4.3.3.
There are two different methods to change the network setup. First, the network
setup can be changed via Web Interface (please refer to chapter 5.5.7.2.1). The
other method that can be performed is subject of the following chapter.
36 Copyright DEV Systemtechnik GmbH 2015-2017
Page 37
User Manual DEV 1953
4.4.2.2 Network Setup via the Serial Interface
Only a few elementary parameters of the network setup can be changed via the
serial interface.
First, establish a hardware connection between a serial port of a PC (e.g. COM1)
and the RS 232 interface of the device (i.e. the connector labeled "Com" at the
CPU module) using a straight cable; please refer to chapter 7 for the pin assignment
of the serial connector.
Next, start a terminal application (e.g. MS Windows HyperTerminal) on the PC.
Note:
The interface settings of the terminal application have to match the standard
serial interface configuration (chapter 4.4.1.1); otherwise, it is not possible to
enter the configuration program as described below.
The terminal application is to be configured that the "Backspace" or "←" key on
the keyboard works properly in the application, and that it sends a <CR> only
(and not a <CR><LF>) when hitting the "Enter" or "" key on the keyboard.
If using MS Windows HyperTerminal, select the "Properties" entry from the
"File" menu and click on the "Settings" tab. There, select "ANSI" from the
Emulation drop down list and then click on the button to uncheck
"Send line ends with line feeds" as shown in the following figure:
4.4.2.2.1 Start and Termination of the Configuration Program
If the serial interface is used for the communication via one of the CPH protocols,
the access to the configuration program can be established during power-up or
after a device reset, only.
In this case, the terminal application is to be started and is to be connected (with
the standard serial interface configuration settings, please refer to chapter 4.4.1.1)
before the boot phase.
While the device is booting press and hold (max. 60 seconds) the keys <Ctrl> and T
(i.e. <Ctrl>-T) in parallel on the keyboard until the following message appears:
please release key
After releasing the keys, the following text is displayed:
You have 60 seconds for login...
DEV login:
To start the configuration program the login procedure must be accomplished
within 60 seconds with the following authentication:
DEV login: config<CR>
Password: devConfig<CR>
Copyright DEV Systemtechnik GmbH 2015-2017 37
Page 38
User Manual DEV 1953
Note:
<CR> stands for hitting the "Enter" or "" key on the keyboard.
All characters/commands to be entered are case sensitive.
If the serial interface is not assigned to any CPH protocol it is not required to
press <Ctrl>-T during the boot process. I.e. it is always possible to enter the
configuration program without any time limits or restrictions regarding the
number of login attempts.
Otherwise (i.e. if a CPH protocol is assigned), if nothing is entered at the
DEV login:prompt, or after the third unsuccessful attempt to login, the CPH
takes over the serial interface which is announced by:
CPH starts now!
After successful authentication, the configuration program is launched. After start
and after the finalization of most of the choices the program lists the choices that
can be performed:
config
======
1 set IP address (192.168.0.225)
2 set netmask (255.255.0.0)
3 set gateway (192.168.0.99)
q quit without saving
x save configuration and exit
your choice >
Choices can be executed by typing the character in the first column of each line
followed by a <CR>. The second column of each line provides a short description of
the choice and the third column displays in parentheses the current setting of the
corresponding choice. In the example above, the IP address and the netmask are
different from the factory network settings (chapter 4.3.3).
When using the "q" choice the configuration program terminates. If a CPH protocol
is assigned, the CPH takes over the serial interface, which is announced by:
CPH starts now!
When using the "x" choice the configuration program saves all changes made and
resets the device (i.e. rebooting the device):
your choice > x<CR>
rebooting the device, please wait...
After a device reset it takes a few moments before the serial interface is accessible
again as described at the beginning of this chapter.
In the following, the available choices are explained:
38 Copyright DEV Systemtechnik GmbH 2015-2017
Page 39
User Manual DEV 1953
4.4.2.2.2 1 set IP address
This choice is used to change the IP address of the device:
(...)
your choice > 1<CR>
Current IP address is 192.168.0.225
Enter IP address ('NONE' to clear) >
To change the current IP address type in a different valid address; to clear the
address type in "NONE<CR>"; and just entering <CR> maintains the current setting:
Enter IP address ('NONE' to clear) ><CR>
unchanged
4.4.2.2.3 2 set netmask
This choice is used to change the netmask of the device:
(...)
your choice > 2<CR>
Current netmask is 255.255.0.0
Enter netmask ('NONE' to clear) >
To change the current netmask type in a different valid entry; to clear it type in
"NONE<CR>"; and just entering <CR> maintains the current setting.
4.4.2.2.4 3 set gateway
This choice is used to change the gateway address of the device:
(...)
your choice > 3<CR>
Current gateway is 192.168.0.99
Enter gateway ('NONE' to clear) >
To change the current gateway address type in a different valid address; to clear
the address type in "NONE<CR>"; and just entering <CR> maintains the current setting.
4.5 Maintenance of the Product
The product is maintenance-free.
Cleaning of the surface of the chassis should be done carefully with a dry lint-free
cloth.
Copyright DEV Systemtechnik GmbH 2015-2017 39
Page 40
User Manual DEV 1953
5 Operation of the Product
After going through the installation steps as described above, the device is ready to
use. There are different options for monitoring and control, please refer to chapter
3.1.2. Before the operation via each of these possibilities is explained, the different
device operation modes are described:
5.1 Modes of Operation
Local Mode, Remote Mode, and Auto Mode define the manner how the device is
controlled. In addition, Individual switching mode and Simultaneous switching
mode define the switching behavior of the device.
The operation mode can be changed via the mode push button at the device panel
(please refer to chapter 3.1.1), via Web Interface (chapter 5.5.2), via SNMP
(chapter 5.9.4.3.1), and via Sandar Prosan protocol (restricted to the change
between Remote Mode and Auto Mode and vice versa (chapter 5.6.3.6)).
Note:
The factory setting for the operation mode is Remote Mode.
Changing the switching mode (chapter 5.1.4) is possible only if the DEV 1953 is
equipped with at least two switch modules.
In Local Mode the switching mode can be altered via the switching mode push
button at the device panel (labeled 8 in the figure of chapter 3.1.1) or via Web
Interface (chapter 5.5.4.1). In Remote Mode, the switching mode can be changed
via Sandar Prosan protocol (chapter 5.6.3.8) and via SNMP (chapter 5.9.4.3.3).
5.1.1 Local Mode
In Local Mode the device executes commands which are issued via push button
actions at the device panel or (also in parallel) via Web Interface.
The optional digital interface is disabled in Local Mode as well as the functionality
of the different remote protocols (SNMP, Sandar Prosan, Leitch, and QEC) to issue
switching commands and to modify the settings of the device. However, the
communication to the remote interfaces either is enabled or is capable to be
enabled (keyword "Echo in Local Mode", please refer to chapters 5.6.1 & 5.7.1) for
status queries.
No autonomous switching is performed in Local Mode if the DEV 1953 is equipped
with sensing switch modules (and/or digital signal switch modules). Neither Time
Based Switching nor TRAC initiated switching is performed in Local Mode, as well.
5.1.2 Remote Mode
The Remote Mode is implemented for operation via the optional digital interface,
via SNMP, via Sandar Prosan protocol, via Leitch protocol, or via QEC protocol.
In Remote Mode, the status of the device is indicated via the LEDs at the device
panel and via Web Interface, but the buttons at the device panel are locked and the
control functionality of the Web Interface is disabled.
No autonomous switching is performed in Remote Mode if the DEV 1953 is
equipped with sensing switch modules (and/or digital signal switch modules).
Neither Time Based Switching nor TRAC initiated switching is performed in
Remote Mode, as well.
40 Copyright DEV Systemtechnik GmbH 2015-2017
Page 41
User Manual DEV 1953
5.1.3 Auto Mode
The Auto Mode is used for Time Based Switching (please refer to chapter 5.5.7.3.4),
or for the optional TRAC functionality (chapter 5.5.7.3.5), or for autonomous
switching if the DEV 1953 is equipped with sensing switch modules (and/or digital
signal switch modules).
As in Remote Mode, the status of the DEV 1953 is indicated via the LEDs at the
device panel and via Web Interface, but the buttons at the device panel are locked
and the control functionality of the Web Interface is disabled.
The optional digital interface is disabled in Auto Mode as well as the functionality of
the different remote protocols (SNMP, Sandar Prosan, Leitch, and QEC) to issue
switching commands and to modify the settings of the device. However, is possible
to issue status queries and to perform some changes on the operation behavior of
the device, e.g. via the Sandar Prosan PMxy commands (chapters 5.6.3.6…5.6.3.9).
Which of the functionalities is activated in Auto Mode can be selected via Web
Interface (chapter 5.5.7.3.2):
the Time Based Switching functionality (chapter 5.5.7.3.4); or
the optional TRAC functionality (chapter 5.5.7.3.5); or
the autonomous switching functionality if the DEV 1953 is equipped with one
or more sensing switch module(s) (and/or digital signal switch module(s)):
5.1.3.1 Autonomous Switching Functionality
The primary input port "In A" and the secondary input port "In B" of the sensing
switch module(s) (digital signal switch module(s)) are continuously monitored
regarding the present RF level (regarding the present digital signal quality,
respectively) if
a. the "Auto Mode Assignment" is set to "Autonomous Switching"
(please refer to chapter 5.5.7.3.2), and if
b. the sensing switch module(s) (digital signal switch module(s))
is (are) switched to the primary input port, and if
c. Auto Mode is activated.
E.g. in Individual switching mode the device switches a sensing switch module
(digital signal switch module) to the secondary input port if
on the primary input port, the RF level falls below the defined RF threshold
level (the digital signal quality becomes "Fail", respectively) and if
on the corresponding secondary input port, the RF level is above the
RF threshold level (the digital signal quality is "OK", respectively).
If neither Option 22 (main backup swap) nor Option 28 (automatic switch back) is
installed, there will be no automatic switching back to the primary input port.
In this case, the switching is to be done explicitly in Local Mode or in Remote Mode.
If Option 22 (main backup swap) is installed, the autonomous switching works in
both directions in the same manner as the switching from the primary to the
secondary input port (as described above).
This means that the device remains switched to the secondary input port unless on
the secondary input port the RF level falls below the RF threshold level (the digital
signal quality becomes "Fail", respectively) and if on the corresponding primary
input port the RF level is above the RF threshold level (the digital signal quality is
"OK", respectively).
Copyright DEV Systemtechnik GmbH 2015-2017 41
Page 42
User Manual DEV 1953
If Option 28 (automatic switch back) is installed and activated (as described in
chapter 5.5.7.3.2), the switching back from the secondary to the primary input port
is initiated by the RF level rising above the RF threshold level again (the digital
signal quality becoming "OK" again, respectively) on the failing primary input port.
This switching back is supported by an offset which is an adjustable hysteresis
(0 dB, 1 dB, 3 dB, or 5 dB) for sensing switch modules, or which is an adjustable
delay (0…10 seconds) for digital signal switch modules.
For the autonomous switching capability has to be considered in addition, whether
Individual switching mode or Simultaneous switching mode is activated
(chapter 5.1.4) and whether (and which) input ports are disabled (chapters 5.5.4.2
& 5.9.4.3.9.2), since this has an influence on the switching behavior. Therefore, the
following scenarios are to be examined for the autonomous switching functionality:
Switching from the primary input port to the secondary input port in
Individual switching mode:
- If both input ports of a sensing switch module (or of a digital signal switch
- If the primary input port of a sensing switch module (digital signal switch
- If the secondary input port of a sensing switch module (digital signal switch
Switching from the primary input port to the secondary input port in
Simultaneous switching mode:
- If all input ports of a group (chapter 5.1.4) are enabled, the autonomous
- If one (or more) of the primary input ports is disabled, this port is (these
module) are enabled, the switching is performed as described above.
I.e. the device switches only if on the primary input port the RF level falls
below the RF threshold level (the digital signal quality becomes "Fail", respectively) and if on the corresponding secondary input port the RF level is
above the RF threshold level (the digital signal quality is "OK", respectively).
module) is disabled, the RF level information (the digital signal quality information, respectively) of the port is ignored as a trigger; i.e. the device does
not switch to the secondary input port.
module) is disabled, the RF level check (the digital signal quality check, respectively) of this port is omitted. Thus, if the sensing switch module (digital signal switch module) is switched to the (enabled) primary input port
and if on the primary input port the RF level drops below the RF threshold
level (the digital signal quality becomes "Fail", respectively), the device unconditionally switches this sensing switch module (digital signal switch
module) to the secondary input port.
switching is performed for all members of the corresponding group from
the primary input ports to the secondary input ports.
The condition is that on the primary input port of one or more members of
the group the RF level drops below the RF threshold level (the digital signal
quality becomes "Fail", respectively) and that on all secondary input ports
of the group the RF level is above the RF threshold level (the digital signal
quality is "OK", respectively).
ports are) not considered in the switching decision, i.e. the device switches
if on the enabled primary input port(s) the RF level drops below the
RF threshold level (the digital signal quality becomes "Fail", respectively).
There is no autonomous switching if all primary input ports of a group are
disabled.
42 Copyright DEV Systemtechnik GmbH 2015-2017
Page 43
User Manual DEV 1953
- If one (or more) secondary input port(s) of a group is (are) disabled, the
With Option 22:
Switching back from the secondary input port to the primary input port in
Individual switching mode:
- If both input ports of a sensing switch module (digital signal switch module)
- If the primary input port of a sensing switch module (digital signal switch
- If the secondary input port of a sensing switch module (digital signal switch
With Option 22:
Switching back from the secondary input ports to the primary input ports in
Simultaneous switching mode:
- If all input ports of a group (chapter 5.1.4) are enabled, the autonomous
- If one (or more) primary input port(s) of a group is (are) disabled, the
- If one (or more) of the secondary input ports is disabled, this port is (these
RF level information (and the digital signal quality information, respectively) of the port(s) is omitted. Thus, disabling one or more secondary
input ports of a group encourages the switching in this situation, since the
signal information of the secondary input port(s) is ignored.
are enabled, the switching is performed as described above.
I.e. the device switches only, if on the secondary input port the RF level falls
below the RF threshold level (the digital signal quality becomes "Fail", respectively) and if on the corresponding primary input port the RF level is
above the RF threshold level (the digital signal quality is "OK").
module) is disabled, the RF level check (the digital signal quality check,
respectively) of this port is omitted. Thus, if the sensing switch module
(digital signal switch module) is switched to the (enabled) secondary input
port and if on the secondary input port the RF level drops below the
RF threshold level (the digital signal quality becomes "Fail", respectively),
the device unconditionally switches to the primary input port.
module) is disabled, the RF level information (the digital signal quality information, respectively) of the port is ignored as a trigger, i.e. the device does
not switch autonomously to the primary input port.
switching is performed for all members of the corresponding group from
the secondary input ports to the primary input ports.
The condition is that on the secondary input port of one or more members
of the group the RF level drops below the RF threshold level (the digital
signal quality becomes "Fail", respectively) and that on all primary input
ports of the group the RF level is above the RF threshold level (the digital
signal quality is "OK", respectively).
RF level information (and the digital signal quality information, respectively) of the port(s) is omitted. Thus, disabling one or more primary input
ports of a group encourages the switching in this situation, since the signal
information of the primary input port(s) is ignored.
ports are) not considered in the switching decision, i.e. the device switches
if on the enabled secondary input port(s) the RF level drops below the
RF threshold level (the digital signal quality becomes "Fail", respectively).
There is no autonomous switching if all secondary input ports of a group
are disabled.
Copyright DEV Systemtechnik GmbH 2015-2017 43
Page 44
User Manual DEV 1953
With (activated) Option 28:
Switching back from the secondary input port to the primary input port in
Individual switching mode:
- If both input ports of a sensing switch module (digital signal switch module)
are enabled, the switching is performed as described above.
I.e. the device switches, if on the primary input port the RF level is above
the RF threshold level again (and the digital signal quality is "OK" again,
respectively) plus an offset value (chapter 5.5.7.3.2).
- If the primary input port of a sensing switch module (digital signal switch
module) is disabled, the RF level check (and the digital signal quality check,
respectively) of this port is omitted. Thus, the device unconditionally
switches to the primary input port.
- The secondary input port is not considered in the switching decision in this
scenario. Therefore, it does not matter whether the secondary input port is
disabled or enabled.
With (activated) Option 28:
Switching back from the secondary input ports to the primary input ports in
Simultaneous switching mode:
- If all input ports of a group (chapter 5.1.4) are enabled, the autonomous
switching is performed for all members of the corresponding group from
the secondary input ports to the primary input ports.
The condition is that on all primary input ports of the group the RF level is
above the RF threshold level again (and the digital signal quality is "OK"
again, respectively) plus the offset value (chapter 5.5.7.3.2).
- If one (or more) primary input port(s) of a group is (are) disabled, the
RF level information (and the digital signal quality information,
respectively) of the port(s) is omitted. Thus, disabling one or more primary
input port(s) of a group encourages the switching in this situation, since the
signal information of this (these) primary input port(s) is ignored.
- The secondary input port(s) of a group is (are) not considered in the
switching decision in this scenario; therefore it does not matter whether
the secondary input port(s) of a group is (are) disabled or enabled.
5.1.4 Individual/Simultaneous Switching Mode
Regarding the signal routing all channels of a DEV 1953 are independent from each
other, but the device provides two switching modes: Individual switching mode and
Simultaneous switching mode.
In Individual switching mode, the installed switch modules can be switched independently from each other. In Simultaneous switching mode a group of switch
modules is switched synchronously to the same input port (either to the primary
input port "In A" or to the secondary input port "In B").
In Local Mode, the selection between Individual switching mode and Simultaneous
switching mode can be performed either via the switching mode push button at the
device panel (labeled 8 in the figure of chapter 3.1.1) or via Web Interface
(chapter 5.5.4.1).
In Remote Mode, the selection between Individual switching mode and
Simultaneous switching mode can be performed via Sandar Prosan protocol
(chapter 5.6.3.8) or via SNMP (chapter 5.9.4.3.3).
44 Copyright DEV Systemtechnik GmbH 2015-2017
Page 45
User Manual DEV 1953
Note:
As the factory setting for the DEV 1953, each module slot is forming a single
group for simultaneous switching. This means, that there are sixteen groups
with a single member each initially and that there is no functional difference
between Individual switching mode and Simultaneous switching mode.
To utilize the advantages of simultaneous switching, the group assignment is to
be altered via Web Interface (in Local Mode and with Individual switching mode
activated, please refer to chapter 5.5.7.3.3).
If the switch modules being member of a group are in different positions, it is
not possible to activate Simultaneous switching mode. In this case, the device
panel channel LEDs of all groups with members that are not in the same
position will toggle twice when operating in Local Mode the switching mode
push button. To resolve this situation the same switching position has to be
established by switching the related (i.e. the Simultaneous switching mode
preventing) switch modules in Individual switching mode before activating
Simultaneous switching mode.
Naturally, the Simultaneous switching mode is not available if the device is
equipped with a single switch module, only.
5.2 Initialization of the Device
The device performs a health check and a configuration check during power-up and
after a device reset. This takes about 60 seconds; there is no manual configuration
necessary, all settings (including the operation mode) after power-up or after a
device reset remain unchanged.
Note:
If not a single switch (or distribution amplifier) module is installed, the device
signalizes this by a permanent event indication (i.e. the channel LEDs at the
device panel are blinking and this cannot be stopped).
5.3 Operation via the Device Panel
The local operation (via push buttons) and the status indication (via LEDs) of the
device panel were already explained in chapter 3.1.1.
Note:
The factory default for the operation mode is Remote Mode.
To operate the push buttons at the device panel, the DEV 1953 has to be
switched to Local Mode via the mode push button at the device panel (please
refer to chapter 3.1.1), via Web Interface (chapter 5.5.2), or via SNMP
(chapter 5.9.4.3.1).
Copyright DEV Systemtechnik GmbH 2015-2017 45
Page 46
User Manual DEV 1953
5.4 Control via the Digital Interface Options
The digital interface options provide basic monitoring and switching functionality
for up to sixteen switch modules, e.g. for the control via a PLC (Programmable Logic
Control). The switching status can be monitored for each switch module via relay
contacts and the switching can be performed for each switch module via a digital
signal.
Please refer to chapter 3.1.4 for the different digital interface options, to chapter
3.2.26 for the drawing of the digital interface module, and to chapter 7 for tech-
nical details and for the pin assignment of the digital interface module connector.
Note:
Since the digital interface is defined as a remote interface, it works only if the
device is in Remote Mode.
If the device is to be switched via the digital interface, it is highly recommended
to disable the CPH (i.e. to change the CPH configuration to "none/configuration
program", chapter 5.5.7.2.3) and not to issue switching commands via SNMP.
Otherwise, this might cause unpredictable switching behavior of the device.
When changing the operation mode in Simultaneous switching mode from
Local Mode or Auto Mode to Remote Mode, the setting of the first member of
a group determines the switching position of the group!
When switching the device to Remote Mode, it is not guaranteed that the
device is in the switching position(s) as given by the potentials of the contacts
of the digital interface. The switching via the digital interface is slope triggered.
Thus, it is recommended to generate a switching event after the activation of
Remote Mode for any switch module in Individual switching mode (or for the
first member of any group in Simultaneous switching mode) with the slope
direction for the desired switching positions, in order to synchronize the device
with the digital interface contacts.
5.5 Operation via Web Interface
The Web Interface is a comfortable user interface for operating the product, i.e. the
device is controlled via a computer and a Web Browser as the communication
application. Several users (assumed the appropriate number of licenses) can access
the device at a time. The first license is included in the delivery. It is possible to
purchase additional license keys at any time, please contact DEV Systemtechnik.
Note:
Most of the screenshots shown in the following were made from the
Web Interface of a DEV 1953 equipped with modules as stated in the example
of chapter 3.3.2, with applied Option 28 (automatic switch back), and with
applied Option 37 (TRAC). Other product configurations may deviate from the
layout but not from the basic functionality of the Web Interface.
Most of the screenshots were obtained from a device without applied digital
signals, thus indicators appear in red, and the digital signal quality indication is
"Fail".
46 Copyright DEV Systemtechnik GmbH 2015-2017
Page 47
User Manual DEV 1953
5.5.1 Start of the Web Interface
To start the Web Interface open a web browser -recommended is Mozilla Firefox
(version 3.5 or higher) but also Chrome, Opera, Safari, or Internet Explorer (starting
with version 8, recommended is version 9 or higher) are supported- and type in the
URL (IP address) of the device:
http://<IP-of-the-device>/
After a moment the Start Screen of the Web Interface appears (as shown below).
To log on the first time use the factory default account:
Username: ADMIN
Password: ADMIN
After entering username and password, click on .
Note:
Both, username and password are case sensitive!
Note the header in the Start Screen:
DEV 1953
SystemName
SystemLocation
The labels "SystemName" and "SystemLocation" are the SNMP variables
'System Name' and 'System Location'; both can be set within the SNMP setup
(please refer to chapter 5.5.7.2.2).
If the Start Screen is unavailable, make sure that the computer accessing the
device is in the same subnet of the common network (chapter 4.4.2.1).
If the network connection to the device gets lost during a session, an appropri-
ate notification will pop up. After confirmation, the web browser is redirected
Copyright DEV Systemtechnik GmbH 2015-2017 47
Page 48
User Manual DEV 1953
to the Start Screen. If the device is accessible again, a new authentication is
required.
During power-up or after a reset the device displays a different screen:
If the device is operational (again), the screen usually automatically changes to
the Start Screen, thus enables the input fields to be edited; if not, please use
the refresh functionality of your web browser (e.g. the function key F5).
The Web Interface permits the definition of a number of users for accessing the
Web Interface in parallel (in accordance to the number of installed licenses). An
additional user who tries to log in receives a corresponding notification
informing about the logged in user(s), e.g.
It is recommended to add users AND to change the password of the factory de-
fault account. How this is to be done is subject of chapters 5.5.7.1.2 & 5.5.7.1.1.
The language of the screenshots shown here is English, as a second language
currently German is available (chapter 5.5.7.1.1).
48 Copyright DEV Systemtechnik GmbH 2015-2017
Page 49
User Manual DEV 1953
5.5.2 The Main Window and Common Features of the Main Tabs
After successful authentication the main window of the Web Interface shows up
with the Status Tab opened, which is the default view:
In the top of the window on the left side, the five (or six) tabs are located ("Status",
"Control", "Events", "Recording" (only for a DEV 1953 with installed sensing switch
modules, please refer to chapter 5.5.6), "Setup", and "Info"). The active tab is
highlighted; clicking on an inactive tab opens the corresponding tab instead.
In the middle on the top of the window three buttons are located indicating that
the device is in Remote Mode (as shown in the screenshot above), or in Local Mode
(as shown in the screenshot of chapter 5.5.3), or in Auto Mode.
Changing the operation mode of the device via Web Interface is performed by
clicking on the desired button, e.g. clicking in the situation above on the button, highlights the button instead of the button. In the representation
of the device panel in the upper part of the Status Tab, the indicators change
correspondingly (here from "Remote" to "Local").
Right to these buttons the currently logged in user (here: "ADMIN") and the permission of the user (here: "admin") are shown. Please refer to chapter 5.5.7.1.2 for
more information on this subject.
Then, the date and time of the device are displayed right to this information. The
correct date and time depends on the proper configuration of an NTP timeserver
and of the timezone (chapter 5.5.7.2.1). Note that if there was no timeserver
detected at power-up, the device sets the date and time to "01-Jan-2000 00:00".
In the right corner close to the company logo, the button is located. Clicking
on this button returns the Web Interface to the Start Screen.
Note:
It is recommended to finish a Web Interface session by clicking on the
button. This instantaneously releases the allocated license and enables other
users to log in.
Copyright DEV Systemtechnik GmbH 2015-2017 49
Page 50
User Manual DEV 1953
A timeout feature (20 seconds) is implemented within the Web Interface, i.e. a
session is automatically terminated (and the allocated license is released) if a
user who is currently logged in closes the web browser.
This means that a Web Interface session is kept open unless the button
is operated or if the web browser (in other words, the connection to the device) is closed.
It is possible to start a Web Interface session on another computer using the
same user account; naturally, this automatically terminates the session on the
preceding computer.
5.5.3 Status Tab
The upper part of the Status Tab shows a simplified representation of the front side
of the device. Thus, a quick overview is provided regarding the detected module
configuration, regarding the operating status, regarding the switching status, and
regarding the health status of the device. The round indicators are equivalent to
the physical LEDs at the device panel (green = ok/activated input, red = failure,
yellow = Remote/Local/Auto/Simultaneous/Individual, or gray = off), please refer to
chapters 3.1.1 & 3.2.25 for details on the indicator information.
In the lower part of the Status Tab, the Active Events Window is located. This
window shows pending and not acknowledged events via the related event
descriptions with a date/time stamp. The events shown in the next screenshot
were triggered for demonstration purpose. Note that the channel LEDs are blinking
in the same manner as on the device; this is the reason why the screenshot can
imply all channels to be switched to the secondary input port (which is not the
case). To obtain more details on the events open the Events Tab (chapter 5.5.5).
50 Copyright DEV Systemtechnik GmbH 2015-2017
Page 51
User Manual DEV 1953
5.5.4 Control Tab
The main purpose of the Control Tab is the switching of the device. Additionally, it
provides means for changing module specific settings.
On the left side, the Control Tab contains the structuring entries "Groups" and
"Switches" in order to branch to the different functionalities of the device. The
number of items within both entries (initially) corresponds to the number of
installed switch modules and the name of each entry ("Group X" or "Switch X") is the
descriptive designator; with "X" (initially) indicating the slot location of the detected
module. Each switch module has to be member of a switch group and initially each
module is assigned to a separate group that is named correspondingly. This group
assignment can be changed, please refer to chapter 5.5.7.3.3.
The descriptive designator ("Group X", "Switch X") can be edited by double-clicking the
specific item:
Note that on the right side in a group panel or in a switch panel, the port names
(here "Channel In 1-1", "Channel In 1-2", & "Channel Out 1") can be edited in the same manner.
Copyright DEV Systemtechnik GmbH 2015-2017 51
Page 52
User Manual DEV 1953
Note:
If changes of settings (which are to be saved explicitly) are applied in a panel of
the Control Tab (or within an entry of the Setup Tab, chapter 5.5.7), they are
highlighted in yellow. If a different panel within the Control Tab (or a different
entry within the Setup Tab) is selected without saving the change(s) in the current panel or entry, a corresponding warning message pops up. The following
figure shows this situation for selecting the "Switch 1" panel after deactivating the
"Surveillance Enable" check box of "Channel In 2-2" in the "Switch 2" panel:
If distribution amplifier modules for ASI/SDI signals are installed, they can be
selected in the same manner within the appearing entry "Distribution Amplifier"
(chapter 5.5.4.3) on the left side of the Control Tab.
Switching and the change of settings within the Control Tab of the Web Inter-
face can be performed by operators with "read/write" or "admin" permission
only, and if the device is in Local Mode.
If a module functionality within a functionality item is selected on the left side of
the Control Tab, the corresponding panel appears on the right side. The different
panels are explained in the following. Note that in the lower right corner of each
panel two buttons are provided for selecting and switching
mode.
52 Copyright DEV Systemtechnik GmbH 2015-2017
Page 53
User Manual DEV 1953
5.5.4.1 Group
If a group is selected on the left side of the Control Tab, the corresponding group
panel appears on the right side where the simultaneous (!) switching of the switch
modules being member of the group can be performed.
The screenshot above shows the device with "Group 1" activated, here -to
demonstrate simultaneous switching- the group is configured with the first three
switch modules as members. I.e. the initial group assignment (each module is
assigned to a separate group) was changed via the related setup functionality;
please refer to chapter 5.5.7.3.3.
The representation of each switch module is realized via two rectangles for the two
input ports and via a circle indicating the switch position.
For switch modules with RF level monitoring functionality (and with digital signal
monitoring functionality, respectively) the present RF levels (and the digital signal
quality information, respectively) of each input port are visible within the
rectangles. A red background implies, that the RF level is below the RF threshold
level (and the digital signal quality is "Fail", respectively), it is green otherwise. The
background color of an input port appears in gray if it does not provide any status
information or if a port (which is capable of generating status information) is
disabled (chapters 5.5.4.2, 5.5.4.3, & 5.9.4.3.9.2).
In the screenshot above, all members of the group are in the same switch position
indicated by the same type of circles. Also, the button (lower right
corner) and to the button (in the middle of the top) are active, indicating
Individual switching mode and Local Mode of the device.
With these preconditions, simultaneous switching is performed as follows:
Copyright DEV Systemtechnik GmbH 2015-2017 53
Page 54
User Manual DEV 1953
First, to activate Simultaneous switching mode click on the button in
the lower right corner:
Then, a click on any of the circles causes two additional buttons to appear
and :
After a click on the button, the command is processed and after the
switching is performed, the switching state (all switch modules of the group are
switched to the secondary input port) is indicated:
54 Copyright DEV Systemtechnik GmbH 2015-2017
Page 55
User Manual DEV 1953
Note:
If the members of a group are not in the same switching position, two types of
circles are displayed. In this situation the button is disabled (grayed
out):
To (re-)enable in this scenario the button (thus Simultaneous
switching mode) either the second, or the first and the third switch module
have to be switched via their switch panels (here assuming that all members of
"Group 2" are already in the same switching position).
Note that the switching via Web Interface can be performed only if the device
is in Local Mode and that the switching via a group panel is possible only if the
device is in Simultaneous switching mode.
If the device is in Simultaneous switching mode, it is possible to switch the
group either via the corresponding group panel or via one of the Switch panels
of any member of the group.
If the device is in Remote Mode or in Auto Mode, the and the
switching mode buttons are disabled (grayed out).
Copyright DEV Systemtechnik GmbH 2015-2017 55
Page 56
User Manual DEV 1953
5.5.4.2 Switch
If a switch is selected on the left side of the Control Tab, the corresponding switch
panel appears on the right side. It consists of two or three sections:
1) In the upper section below the descriptive designator (here: "Switch 4"), first the
"Input Port Numbers" and the "Output Port Number" of the switch module are shown as a
reference to the index of the SNMP .portTable (please refer to chapter 5.9.4.3.9)
and if port specific events are to be identified in the Events Tab (chapter 5.5.5).
Then the "Module Type" (here: "DEV 11-0014") and the "Group Assignment" (here:
"Group 2") are listed. Additionally -with Option 28 (chapter 5.5.7.3.2) installed
and activated-, the line "Automatic Switch Back at" indicates the switch back level;
here with "-27.0 dBm" an offset (i.e. 3 dB) to the (standard -30 dBm) RF threshold
level setting is displayed.
2) Within the second section, the switching status of the switch module is shown
and can be changed.
Depending on the active switching mode, either the individual switching of the
current switch module can be performed, or the simultaneous switching of the
group to which the current switch module is assigned to. The switching mode is
indicated at the lower right of any switch panel by one of the buttons
or being activated (i.e. or ).
The screenshot above shows in the middle the measured RF level of each input
port on the left side. The green background implies that the level is above the
individual threshold, it is red otherwise.
The background color of a port rectangle appears in gray if it is disabled (e.g. by
deactivating the corresponding "Surveillance Enable" check box), or if it does not
provide any status information.
56 Copyright DEV Systemtechnik GmbH 2015-2017
Page 57
User Manual DEV 1953
The individual switching of a switch module is performed as follows:
To switch in Local Mode (!) only the selected module, Individual switching
mode is to be activated; i.e. in this scenario, the button in the lower
right corner is to be operated:
Next, click on the circle between the representation of inputs and output,
which causes two additional buttons to appear:
After a click on the button, the actual switching is performed and the
new status (the module is switched to the secondary input port) is shown:
Please note that the button becomes disabled (grayed out:
), indicating that the device cannot be switched back to Simultaneous switching mode, since the switch modules which are member of the
group (here: "Group 2") are not in the same switching position now.
Copyright DEV Systemtechnik GmbH 2015-2017 57
Page 58
User Manual DEV 1953
Note:
• The input ports of many switch modules appear as gray rectangles:
• Enabled (!) input ports of digital signal switch modules which are capable of
judging the digital signal quality are shown as rectangles with a red or with
a green background:
• Again, if the device is in Remote Mode or in Auto Mode, the and
the switching mode buttons are disabled (grayed out).
3) For sensing switch modules and for digital signal switch modules a third section
appears below the switching section permitting the modification of module
specific parameters. Note that after settings have been altered within this
section in Local Mode (!), a click on the button is necessary to
apply the changes:
• For both input ports of a sensing switch module, the "RF Threshold" can be
adjusted individually within a certain range.
• The "Surveillance Enable" check boxes are used to enable (default) or to disable
events possibly caused by the input ports of sensing switch modules and of
digital signal switch modules.
58 Copyright DEV Systemtechnik GmbH 2015-2017
Page 59
User Manual DEV 1953
5.5.4.3 Distribution Amplifier
This kind of panel (within the appearing structuring entry "Distribution Amplifier") is
available only for devices with installed distribution amplifier modules for ASI/SDI
signals, i.e. for the screenshot above a distribution amplifier module was installed
temporarily in the tenth slot. The panel consists of two sections:
1) In the upper section below the descriptive designator (here: "Amp 10"), first the
"Port Number" of the module is shown as a reference to the index of the SNMP
.portTable (please refer to chapter 5.9.4.3.9) and if port specific events are to be
identified within the Events Tab (chapter 5.5.5). Then the "Module Type" is listed
(here: "DEV 14-0092"). Finally, the "Signal Status" is an assessment regarding the
detected signal quality that can be either "Fail" (red) or "OK" (green).
2) In the "Setup" section, the "Surveillance Enable" check box is used to enable (default)
or to disable events possibly caused by the related port. Note that after this
setting was altered in Local Mode (!), a click on the button is
required to apply the change.
Copyright DEV Systemtechnik GmbH 2015-2017 59
Page 60
User Manual DEV 1953
5.5.5 Events Tab
The Events Tab displays a table of the events that were detected by the device.
The different events are listed line-by-line, i.e. each event carries a Date/Time
stamp (in the format: "DDD DD MMM YYYY hh:mm:ss", here e.g. "Wed 06 Sep 2017 16:15:29")
informing about the last occurrence of that event. The second column is a Counter
reporting the number of occurrences of that event (here: "1"). The third column
denotes whether that event is Ack.nowledged ("X") or not ("") (here e.g. "", i.e.
<space>, meaning not acknowledged). The fourth column shows whether that event
is Pend.ing ("X") or not ("") (here: "X", i.e. pending). The fifth and the sixth columns
inform about the error code No. in Hexadecimal (here e.g. "1302") and in Decimal
(here e.g. "4866") notation; the last column reports the related Event Description
string (here e.g. "Power Supply 2"), please refer to chapter 6.1.
Below, the buttons and are located:
An event can be acknowledged by highlighting (i.e. clicking on) the related line and
by operating the button afterwards. The intention of the
acknowledgement of an event is to provide means to mask out a pending event of
the Active Events Window in the Status Tab (chapter 5.5.3) and to stop the event
indication via device panel (chapter 3.1.1) and via Status Tab (chapter 5.5.3) if all
pending events in the table are acknowledged. If a confirmed event occurs again,
the counter in the table is increased and the acknowledgement is reset (i.e. the "X"
disappears, the Active Events Window reports the event again, and the event
indication via device panel and via Status Tab becomes active).
An acknowledged and not pending event can be deleted from the list by high-
lighting the corresponding line, followed by clicking on .
If a deleted event occurs again, a line is added at the beginning of the table.
60 Copyright DEV Systemtechnik GmbH 2015-2017
Page 61
User Manual DEV 1953
Note:
It is possible to acknowledge (and to delete) more than one entry at a time by
highlighting more events using the <Ctrl> or the <Shift> key of the keyboard in
combination with mouse click(s).
Users with "read" permission only have no rights to acknowledge or to delete
event entries (chapter 5.5.7.1.2).
If an event is still pending or not acknowledged, it cannot be deleted.
The table content can be stored using the data backup functionality
(chapter 5.5.7.4.2).
5.5.6 Recording Tab
The Recording Tab is available only if the DEV 1953 is equipped with sensing switch
module(s). For this type of modules, the RF level data is continuously captured in
discrete intervals. The Recording Tab permits the visualization and the external
storage of this data.
After opening the Recording Tab for the first time in a Web Interface session, two
empty diagrams labeled "Overview" and "Details" are shown as in the next
screenshot.
In this application, the drop down list "Signal Type" permits the selection of
"RF Level" only.
After selecting one to three "Signals" via the three drop down lists, the recorded
data shows up in both diagrams:
Copyright DEV Systemtechnik GmbH 2015-2017 61
Page 62
User Manual DEV 1953
Note:
The recording interval and thus the recording duration can be altered, please
refer to chapter 5.5.7.3.1. The data representation initially always comprises
the recorded data for the selected items, i.e. it is stretched if the full recording
duration is not reached yet, and the graphs indicate via gaps if the device was
turned off for a span of time.
The checkbox labeled "Show Thresholds" enables the display of the related
present threshold for the selected signals. If checked, each threshold is shown
as a separate horizontal line with an individual label.
It is possible to magnify the data by drawing a zoom window in either (!) diagram,
i.e. by clicking and holding the left mouse button while pulling the mouse over the
interesting area:
62 Copyright DEV Systemtechnik GmbH 2015-2017
Page 63
User Manual DEV 1953
Directly after releasing the left mouse button, the zoomed area appears in the
"Details" diagram while the "Overview" diagram is highlighting the zoomed area:
Three buttons are located at the bottom of the Recording Tab:
If the recorded data of the selected items was zoomed as described above, the but-
ton resets the data representation to the initial state, i.e. all recorded
data for the selected signals is displayed in both diagrams.
The remaining two buttons provide the option to store the captured data externally
(without the possibly displayed thresholds!). stores the recorded data
of the currently selected signals and the button stores all recorded data of
the device, i.e. the available data of all signals. After operating one of the buttons, a
browser specific window pops up and suggests the storage of the data as
"recording.csv" and as "recording_all.csv", respectively. The csv (comma-separated values)
file format permits the data import e.g. into a MS Excel worksheet:
The csv-file is a text file modeling a table. Each line is interpreted as row containing
column information, here with the columns delimited by a semicolon (";") character as the column separator.
The number of columns depends on the export method ( vs. ).
If the button is selected, the number of columns depends on the
number of signals currently presented. In any case, each signal consists of a "Time"
and of a "Value" column; the number of lines depends on the recording duration
(over 17000 lines e.g. within two days with the default ten seconds recording
interval).
The first line of the csv-file is the header line providing the column information. The
first entry is assigned to the first signal (e.g. "Channel In 4-1", indicating the
(default) port name of the primary input port of the sensing switch module in the
fourth slot, please refer to chapter 5.5.4), concatenated with the "Signal Type" (i.e.
here always "RF Level") and with "Time". After the semicolon, the same entry is
Copyright DEV Systemtechnik GmbH 2015-2017 63
Page 64
User Manual DEV 1953
Channel In 4-1
RF Level Time
Channel In 4-1
RF Level Values
Channel In 4-2
RF Level Time
Channel In 4-2
RF Level Values
25-Aug-2017, 17:12:47
-25.5
25-Aug-2017, 17:12:47
-24.7
25-Aug-2017, 17:13:47
-25.5
25-Aug-2017, 17:13:47
-24.7
25-Aug-2017, 17:14:47
-25.5
25-Aug-2017, 17:14:47
-24.7
25-Aug-2017, 17:15:47
-25.5
25-Aug-2017, 17:15:47
-24.7
25-Aug-2017, 17:16:47
-25.5
25-Aug-2017, 17:16:47
-24.6
25-Aug-2017, 17:17:47
-25.5
25-Aug-2017, 17:17:47
-24.7
25-Aug-2017, 17:18:47
-25.5
25-Aug-2017, 17:18:47
-24.7
listed with "Values" instead of "Time". This sequence is repeated for all columns that
are part of the csv-file.
The actual data starts in the second line of the csv-file. Note that the time
information is stated in standard MS Excel format, i.e. the integral part of the
number defines the date (starting from 1 being the 01-Jan-1900, e.g. 42972
denotes the date 25-Aug-2017) and the fractional part defines the time within the
date (1/(24 * 60 * 60) = 00:00:01, e.g. .71875 = 17:15:00).
In the following only the first few lines of a csv-file are listed which was created by
exporting the data shown in this chapter via the button ("⌡" and "⌠"
are symbolizing that the two consecutive lines are actually one line in the file):
Channel In 4-1 RF Level Time;Channel In 4-1 RF Level Values;⌡
Channel In 4-2 RF Level Time;Channel In 4-2 RF Level Values;
After import and formatting the "Time" columns to the format
"DD-MMM-YYYY, hh:mm:ss" this results in the following table:
Note:
The decimal separator in the csv-file is the point character ("."), this has to be
considered during the data import of the csv-file e.g. into an Excel worksheet.
For the data import into an empty MS Excel worksheet select the tab "Data"
and there the icon "From Text". Then locate the csv-file and follow the instructions of the text import wizard.
The correct time information is dependent on the proper configuration of a
timeserver and of the timezone. The settings can be applied via the network
setup of the Setup Tab (chapter 5.5.7.2.1).
If no timeserver is configured for the device, the recording of the data starts at
01-Jan-2000, 00:00:00; after a device reset the time is reset to 01-Jan-2000,
00:00:00 as well, but the recording of the data is continued with the time of the
last sample.
If a timeserver was configured for the device that is not available anymore after
a reset, the recording of the data is continued with the time of the last sample
as well. Otherwise, if the timeserver is available after a device reset, the
recording of the data is continued with the correct time; i.e. this causes a time
gap within the data.
64 Copyright DEV Systemtechnik GmbH 2015-2017
Page 65
User Manual DEV 1953
5.5.7 Setup Tab
On the left side, the Setup Tab contains the menu items structuring the different
entries described in the following. Initially, the single entries are not displayed:
To demonstrate the available setup entries, all menu items above were folded out
in the following screenshot:
Copyright DEV Systemtechnik GmbH 2015-2017 65
Page 66
User Manual DEV 1953
5.5.7.1 User Setup
The menu item User Setup on the left side of the Setup Tab provides access to the
Password and Language entry for all users and access to the User Management
entry for users with "admin" permission.
5.5.7.1.1 Password and Language
The input fields of the Password and Language entry enable the user who is currently logged in to change the password and to alter the personal language setting.
To change the password, enter the old password, the new password, and the confirmation of the new password.
To change the language, select an entry from the drop down list "Language".
A click on the button applies the changes made. If the password has
been changed, a window pops up for confirmation.
Note:
English and German are the languages supported by the current firmware.
5.5.7.1.2 User Management
The currently logged in user has to have "admin" permission to access the User
Management entry where users can be added or deleted and the permission can
be modified.
In the next screenshot, a user named TEST with "admin" permission is in the pro-
cess to be restricted to "read/write" permission. After a click on the
button, this user will then have all rights but only access to the Password and Language entry within the Setup Tab. A user with "read" permission additionally is not
able to apply any changes within the other tabs of the Web Interface.
66 Copyright DEV Systemtechnik GmbH 2015-2017
Page 67
User Manual DEV 1953
To add a new user click on the item "Add New User" and enter a name in the appearing text field and click again. By default this new user has "read" permission
and no password is set for this user.
By activating an existing user, the permission category can be altered and a password can be set for this user. A click on the button applies the changes
made. If the password has been changed, a confirmation window pops up.
To delete a user, click on the trash bin icon right to the user entry, a window pops
up for confirmation.
Note:
As already mentioned, user names and passwords are case sensitive!
Do not forget to click on the button to store the settings made
before selecting (or adding) another user!
A user logs on without any password if this user was added without an assigned
password. The following message pops up during the login process:
It is not possible to delete the ADMIN user but it is recommended to change
the default password!
Copyright DEV Systemtechnik GmbH 2015-2017 67
Page 68
User Manual DEV 1953
5.5.7.2 System Setup
The menu item System Setup on the left side of the Setup Tab provides access to
the Network entry, to the SNMP entry, and to the CPH entry for users with "admin"
permission.
5.5.7.2.1 Network
For the network setup of the device, at least the fields "IP Address" and "Netmask"
have to contain valid entries.
"Gateway", "Nameserver 1", and "Nameserver 2" are to be specified by their IP addresses; the "Nameserver" entries are used for the resolution of the "Timeserver"
fields, only.
The "Timeserver" fields are used to specify one or two timeservers either via fullqualified domain name or via IP address.
To specify the timezone select an entry from the drop down list "Timezone":
68 Copyright DEV Systemtechnik GmbH 2015-2017
Page 69
User Manual DEV 1953
A click on the button applies the changes made.
If the IP address has been changed, a confirmation window pops up informing
about the redirection of the browser to the new address, e.g.:
Note:
The LED symbols right to the fields for the gateway, for the name servers, and
for the timeservers indicate whether the saved (!) entry is an available network
resource (green) or not (red).
5.5.7.2.2 SNMP
With the SNMP setup, the settings for "System Name" and "System Location" can
be modified. A "System Administrator" can be defined and the passwords for the
"Read Community" and for the "Write Community" can be set. The check box
below these entries is used to enable the switching between Local Mode, Remote
Mode, and Auto Mode via SNMP, please refer to chapter 5.9.4.3.1.
Additionally, up to four Trap Destination IP Addresses can be defined via the IP address and the port in the format <ip-address>{:<port>}, e.g. 192.168.0.148:121. If <port> is not
specified, the standard SNMP trap port 162 is assumed. The LED symbols right to
the IP addresses fields indicate (after the entries have been saved) whether the addresses are available network resources (green) or not (red). The community for
each of the four entries can be altered from the default "public" as well.
The check boxes below the header "Enabled Traps" provide access to the SNMP
.trapEnableMask (chapter 5.9.4.4.1) via Web Interface.
Finally, a click on the icon initiates the download of the MIB of the device.
A click on the button applies the changes made.
Copyright DEV Systemtechnik GmbH 2015-2017 69
Page 70
User Manual DEV 1953
Note:
The strings "System Name" and "System Location" are part of standard SNMP
functionality and are limited to 40 characters, each. The number of visible
characters in the text fields is limited by the field size.
As mentioned, the strings "System Name" and "System Location" are also
displayed in the Start Screen of the Web Interface (chapter 5.5.1).
5.5.7.2.3 CPH
To change the protocol assignment within the CPH setup, choose the desired protocol from the drop down list "CPH Protocol". If "none/configuration program" is selected, the CPH is disabled and the serial interface is used for the configuration program (please refer to chapter 4.4.2.2) with the settings described in chapter 4.4.1.1.
Selecting any other entry changes the assignment to the selected protocol (Prosan,
Leitch, or QEC):
If "Prosan" is selected, the check box "Echo in Local Mode" appears in addition to
the drop down list "CPH Protocol". Chapter 5.6.1 explains the impact when
enabling/disabling "Echo in Local Mode".
If "Leitch" is selected, the "Echo in Local Mode" and "Individual Switch Level Assignment" check boxes are appearing in addition to the drop down list "CPH Protocol".
Chapter 5.7.1 explains the impact when enabling/disabling "Echo in Local Mode"
and "Individual Switch Level Assignment".
70 Copyright DEV Systemtechnik GmbH 2015-2017
Page 71
User Manual DEV 1953
If "QEC" is selected, the drop down list "QEC Serial Address" appears in addition to
the drop down list "CPH Protocol". The device address for the serial communication
via QEC protocol (chapter 5.8) can be modified in the range 0x00…0xFF.
A click on the button applies the changes made and restarts
the device. This is indicated via a confirmation window, e.g.
Copyright DEV Systemtechnik GmbH 2015-2017 71
Page 72
User Manual DEV 1953
Recording Interval
Resulting Recording Duration
10 Seconds
2 Days
30 Seconds
6 Days
60 Seconds
12 Days
5.5.7.3 Feature Setup
The Feature Setup menu item on the left side of the Setup Tab provides access for
users with "admin" permission to the device specific setup entries, i.e. to the Recording entry, to the Auto Mode entry, to the Group Assignment entry, to the Time
Based Switching entry, to the optional TRAC submenu and to the Actions submenu.
5.5.7.3.1 Recording
The Recording entry is available only if the product is equipped with sensing switch
modules. The entry permits the configuration of the interval for the signal
recording functionality; please refer to chapter 5.5.6.
Via the "Recording Interval" drop down list the interval for the regular data capture
can be selected. After an entry was picked, the "Resulting Recording Duration" is
displayed in the line below. The following choices are available:
Note:
After clicking on the button with a different recording interval
selected than the currently applied setting all stored recording data is deleted
instantaneously; the recording starts with the new recording interval setting!
The default recording interval setting is 10 seconds; after a Restore Factory
Defaults (chapter 5.5.7.4.1), this setting is applied as well.
72 Copyright DEV Systemtechnik GmbH 2015-2017
Page 73
User Manual DEV 1953
5.5.7.3.2 Auto Mode
The Auto Mode entry is required for selecting the functionality that the device is
supposed to perform if Auto Mode is activated.
Additionally and only if Option 28 is installed, the "Automatic Switch Back" section
appears in which the automatic switch back functionality (please refer to chapters
3.1.3 & 5.1.3) can be activated and configured.
The drop down list "Auto Mode Assignment" provides up to three entries:
1) Autonomous Switching
Only if the device is equipped with sensing switch modules and/or with digital
signal switch modules this entry is available and can be selected.
If "Autonomous Switching" is activated, the autonomous switching functionality of the device based on the RF level information (and on the digital signal
quality, respectively) is enabled in Auto Mode.
2) Time Based Switching
The Time Based Switching functionality (chapter 5.5.7.3.4) is enabled in Auto
Mode if this entry is activated.
3) TRAC
This entry is available and can be selected only if the device is equipped with
the TRAC option. The TRAC functionality (chapter 5.5.7.3.5) is enabled in Auto
Mode if "TRAC" is activated.
If Option 28 is installed, the automatic switch back functionality can be activated
and configured in the section "Automatic Switch Back" within the Auto Mode entry.
As described in chapter 5.1.3, with this functionality activated -and the Auto Mode
Assignment set to "Autonomous Switching"-, the autonomous switching functionality can be extended in a way that the device in Auto Mode can switch single
(if Individual switching mode is active) or groups of (if Simultaneous switching
mode is active) signal paths back to the primary input port(s).
Copyright DEV Systemtechnik GmbH 2015-2017 73
Page 74
User Manual DEV 1953
The check box labeled "Enable Automatic Switch Back" is used for the activation/
deactivation of the automatic switch back functionality.
If an installed sensing switch module is switched to the secondary input port and if
on the primary input port the RF level rises above the corresponding RF threshold
level plus an offset value, the device switches back to the primary input port. This
offset value (0 dB, 1 dB, 3 dB, or 5 dB) can be selected via the drop down list
labeled "Hysteresis for Automatic Switch Back":
If an installed digital signal switch module is switched to the secondary input port
and if on the primary input port the signal quality becomes "OK" again for a
selected time, the device switches back to the primary input port. This time (0…10
seconds) can be selected via the drop down list labeled "Switch Back Time for
Automatic Switch Back (ASI/SD-SDI/HD-SDI/3G-SDI)":
A click on the button applies the changes made.
Note:
If Option 22 is installed, the main backup swap functionality is activated perma-
nently if the Auto Mode Assignment set to "Autonomous Switching"! No explicit adjustments need to be performed.
By default the Auto Mode Assignment set to "Autonomous Switching" (if appli-
cable) and -if Option 28 is installed- the automatic switch back functionality is
activated; is set to "0" dB for sensing switch modules and is set to "10" seconds
for digital signal switch modules; these settings are applied as well after a
Restore Factory Defaults (chapter 5.5.7.4.1).
74 Copyright DEV Systemtechnik GmbH 2015-2017
Page 75
User Manual DEV 1953
5.5.7.3.3 Group Assignment
The Group Assignment entry permits the modification of the assignment of the
switch modules to switch groups.
Each switch module of a device has to be assigned to a group. As stated in chapter
5.1.4 the factory setting for the DEV 1953 is that each module slot is forming a
single group. This means, that initially there are sixteen groups with a single member each, and that there is no functional difference between Individual switching
mode and Simultaneous switching mode. To utilize the advantages of simultaneous
switching the group assignment is to be altered. To change the assignment of one
or more switch modules using the Group Assignment entry make sure that the
device is in Local Mode and that Individual switching mode is activated. Then in the
assignment matrix select the row(s) of the desired module(s) and the column(s) of
the desired group(s) and click on the square(s). The background of the square(s)
becomes yellow:
A click on the button is necessary to apply the changes:
Copyright DEV Systemtechnik GmbH 2015-2017 75
Page 76
User Manual DEV 1953
Note:
The device has to be in Local Mode and in Individual switching mode to change
the group assignment of a switch module; otherwise the assignment matrix is
grayed out.
It is recommended to use consecutive group numbers (starting from "Group 1")
to keep the reference to the entries in the SNMP .switchGroupTable
(chapter 5.9.4.3.5).
It is suggested to configure groups for the installed switch (!) modules as
desired and to assign all empty slots and all slots populated with a passive
module or with a distribution amplifier module to the next vacant group
number.
A group is shown and can be selected within the structuring entry "Groups" on
the left side of the Control Tab (chapter 5.5.4) if it contains at least one
member.
5.5.7.3.4 Time Based Switching
Time Based Switching is a functionality to enable the time controlled switching of
the device.
The following prerequisites are to be considered:
Time Based Switching is to be configured via the Web Interface, only.
The device needs to obtain the present time from a timeserver, i.e. the
network setup of the device may have to be supplemented with the entry for a
valid timeserver, and the local timezone may have to be adjusted, please refer
to chapter 5.5.7.2.1.
The present device time is displayed in the top of the window left to the
button. Note that if there was no timeserver detected at power up, the device
sets the date and time to "01-Jan-2000 00:00".
76 Copyright DEV Systemtechnik GmbH 2015-2017
Page 77
User Manual DEV 1953
For setting up Time Based Switching within the Web Interface, activate Local Mode
(in order to suppress unwanted switching actions during the setup).
As the first step select "Time Based Switching" in the drop down list
"Auto Mode Assignment" of the Auto Mode entry (chapter 5.5.7.3.2) and save
the change.
Next, within the Switching Actions entry (chapter 5.5.7.3.6.1) at least one
switching action needs to be defined.
After that, at least one trigger of the Time Based Switching entry (see below)
needs to be defined and to be enabled.
For arming the device for Time Based Switching, activate the Auto Mode.
After selecting the entry Time Based Switching on the left side of the Setup Tab
click on the item "Add new trigger" and enter a name in the appearing text field
(here: "Wednesday 17:45").
Next, select the name in the list to enable the definition of the trigger (alternatively
and if applicable, click on an existing trigger to modify it):
Either a time trigger is defined:
repetitive for one or more weekdays by checking the corresponding box(es)
(here, We(dnesday) was chosen), or it is defined as a
single occurrence using the drop down lists below "Day" and "Month" for
defining the date.
Note that when checking one or more weekdays, the drop down lists for "Day" and
for "Month" become grayed out and vice versa, when selecting a "Day" and/or a
"Month", the weekday check boxes become grayed out. In this case -i.e. to reenable the weekday check boxes-, choose the first entry (blank entry above entry
"01") in both drop down lists for "Day" and "Month".
After specifying the weekday(s) or the date select the time for the switching event
via the drop down lists for "Hour" (here: "17"), "Minute" (here: "45"), and "Second"
(here: "00", thus unchanged).
Copyright DEV Systemtechnik GmbH 2015-2017 77
Page 78
User Manual DEV 1953
Then select the Switching Action via the drop down list. Here an action is shown
and selected as the default that was defined already via the Switching Actions setup
entry (chapter 5.5.7.3.6.1).
As the last step in defining a time trigger either activate the trigger by checking the
box right to the "Enabled" label, or leave it unchecked if it is intended to set up the
trigger in advance:
Finally, click on the button to store the settings made before selecting
(or adding) another trigger and/or before activating the Time Based Switching by
clicking on the button.
Note:
The check box labeled "Enabled" is grayed out and the message "Not enabled in
Auto Mode Assignment" appears if "Time Based Switching" is not activated in
the "Auto Mode Assignment" of the Auto Mode entry (chapter 5.5.7.3.2).
If the connection to the timeserver is not established, this is displayed in the
Time Based Switching functionality via the message: "Warning: The device currently does
not receive a valid time from an NTP server, so time based switching may not work properly. Please check the
time server configuration". Time Based Switching can be activated in such a case as
well, but this may cause unwanted switching of the device.
Neither the activated time triggers nor the activated Switching Actions are
checked for ambiguity or contradictions. The behavior of the device is not
predictable in such a case.
It is recommended to perform Time Based Switching with the device set to
Individual switching mode (chapter 5.5.4.1) and rather to use appropriately
configured Switching Actions to avoid unwanted switching behavior.
To copy a trigger click on the icon left to the trash bin icon of the trigger entry.
The copy which is appearing has the same name but with a leading "Copy of"
(which can be renamed by double clicking the name).
To delete a trigger click on the trash bin icon right to the trigger entry.
A window pops up for confirmation.
78 Copyright DEV Systemtechnik GmbH 2015-2017
Page 79
User Manual DEV 1953
Finally, do not forget to click on the button to activate the Time Based
Switching:
5.5.7.3.5 TRAC
The TRAC submenu is available in the menu item Feature Setup of the Setup Tab
only if the device is equipped with Option 37.
TRAC (stands for "Trap Receiver Action Controller") is a powerful feature enabling
the device to execute Switching Actions (please refer to chapter 5.5.7.3.6.1) based
on received SNMP traps or on IP Monitoring.
The following prerequisites are to be considered:
TRAC is to be configured via the Web Interface, only.
If Switching Actions based on received SNMP traps (trap triggers) are pursued,
the DEV 1953 must be configured as trap destination within the device that is
sending the traps.
For example, if the device is a DEV 1951, activate the SNMP setup (chapter
5.5.7.2.2) there and enter the IP address of the DEV 1953 in one of the four
Trap Destination IP Address fields. No changes on the port setting (162) or on
the community are required if the TRAC Setup (chapter 5.5.7.3.5.1, description
of the upper section) of the DEV 1953 was not changed. Then, one or more
traps should be enabled within the SNMP setup of the DEV 1951 before saving
the changes.
Note that traps received by the device (in the example: the DEV 1953) can be
monitored via the Trap Log (chapter 5.5.7.3.5.3).
If Switching Actions based on IP Monitoring are pursued, the target device
causing switching actions has to support and must be reachable via ICMP Echo
Requests (better known as "ping").
Select "TRAC" in the drop down list "Auto Mode Assignment" of the Auto Mode
entry (chapter 5.5.7.3.2) and save the change.
It is recommended to activate Individual switching mode (e.g. via the Control
Tab in Local Mode, chapter 5.5.4.1) and to define the necessary Switching
Actions (chapter 5.5.7.3.6.1) before the definition of trap triggers or of
IP Monitoring triggers and before switching the device to Auto Mode.
The definition of trap triggers is explained within the description of the TRAC Setup
entry (chapter 5.5.7.3.5.1); here the usage of the Trap Log (chapter 5.5.7.3.5.3) as
definition support for trap triggers is explained as well. The definition of
IP Monitoring triggers is subject of chapter 5.5.7.3.5.2.
Copyright DEV Systemtechnik GmbH 2015-2017 79
Page 80
User Manual DEV 1953
5.5.7.3.5.1 TRAC Setup
In the upper section, the TRAC Setup entry is used for the trap receiver settings and
for the definition of trap triggers in the lower section.
The TRAC Setup section comprises the fields "Trap Receiver Community" and "Trap
Receiver Port". By default, the "Trap Receiver Community" contains no entry, thus
not any restriction in the reception of traps. When entering e.g. "public" the reception of traps is restricted to traps of the "public" community, only. The standard
SNMP trap port 162 is the default "Trap Receiver Port". This value can be changed if
required.
It is recommended to click on the button to store the settings made
before continuing with the definition of trap triggers.
To define a trap trigger the entries in the section "Trap Trigger" can be defined
manually but an assisted procedure is recommended and described next:
As the first step, activate the Trap Log entry on the left of the Setup Tab:
The traps received by the device are listed here (for details, please refer to
chapter 5.5.7.3.5.3). Select a trap by clicking on the corresponding line in the upper
table. After activation, the details of the trap are listed in the lower table named
"Variable Bindings":
80 Copyright DEV Systemtechnik GmbH 2015-2017
Page 81
User Manual DEV 1953
After the verification, that the highlighted trap contains the desired information it
can be transferred to the section "Trap Trigger" of the TRAC Setup entry by clicking
on :
The click on the button automatically activates the
TRAC Setup entry comprising a new entry in the Trap Trigger section named
"Added from Trap Log" and the settings for "Source IP", "Enterprise OID", "Trap
Specific", and the "Variable Bindings" as obtained from the Trap Log:
Copyright DEV Systemtechnik GmbH 2015-2017 81
Page 82
User Manual DEV 1953
As the next step, it is recommended to alter the name of the trap trigger to avoid
confusion when importing another trap entry in the same manner. This is done in
the usual way by double-clicking the entry:
After the renaming at least the "Switching Action" is to be selected via the related
drop down list (again, the appropriate Switching Actions (chapter 5.5.7.3.6.1)
should have been defined already) and the trap trigger needs to be enabled via the
"Enabled" check box.
If required changes to the "Variable Bindings Matching Rules" table can be applied
in addition:
Existing lines in the table can be deleted by clicking on the red "X" on the right
side. Additional lines can be added using the blue "+" on the right side after the
last line.
Each line listed can be edited in the three columns "OID", "Op." (stands for "Op-
erator"), and "Value". For "OID" and "Value" manual entries are required, the
wildcard character "*" can be used in the "OID" column and substitutes a single
OID specifier item. For the "Op." entry a drop down list is provided as shown in
the following screenshot (the provided operators are self-explanatory; "RE"
stands for "Regular Expression", i.e. the "Value" is expected to be in Perl syntax,
please refer for instance to http://perldoc.perl.org/perlre.html):
82 Copyright DEV Systemtechnik GmbH 2015-2017
Page 83
User Manual DEV 1953
As the last step, click on the button to store the settings made. All
enabled triggers (trap triggers and IP Monitoring triggers) are activated by clicking
on the button.
Note:
If either entry "Source IP", or "Enterprise OID", or "Trap Specific" is left blank
means the acceptance of any corresponding incoming data!
Again, the wildcard character "*" (as a placeholder for any character) can be
used in the "Variable Bindings Matching Rules" table within the OID only, e.g.
.1.3.6.1.4.1.21035.41.*.1.0 instead of .1.3.6.1.4.1.21035.41.2.1.0.
The check box labeled "Enabled" is grayed out and the message "Not enabled in
Auto Mode Assignment" appears if "TRAC" is not activated in the drop down
list "Auto Mode Assignment" (chapter 5.5.7.3.2).
Neither the activated trap triggers nor the activated Switching Actions are
checked for ambiguity or contradictions. The behavior of the device is not
predictable in such a case.
To copy a trap trigger click on the icon left to the trash bin icon of the trigger
entry. The copy which is appearing has the same name but with a leading
"Copy of" (which can be renamed by double clicking the name).
To delete a trigger click on the trash bin icon right to the trigger entry.
A window pops up for confirmation.
Copyright DEV Systemtechnik GmbH 2015-2017 83
Page 84
User Manual DEV 1953
5.5.7.3.5.2 IP Monitor
The IP Monitoring entry can be used for the definition of triggers in order to switch
the DEV 1953 based on the availability or on the absence of a target device, e.g. a
video router. Again, the target device has to support and must be reachable via
ICMP Echo Requests ("ping").
The definition of a trigger within the IP Monitoring entry is done in the same
manner as for time triggers (please refer to chapter 5.5.7.3.4) or for trap triggers
(chapter 5.5.7.3.5.1):
84 Copyright DEV Systemtechnik GmbH 2015-2017
Page 85
User Manual DEV 1953
After clicking on "Add new trigger" a sensible name for the trigger is to be entered
(here: "1951 unreachable"). Then after selecting the new entry on the left side, the
definition of the trigger is performed on the right side.
Here, the "Destination IP" (the IP address of the target device) needs to be entered.
The "Interval" defines the time between the attempts to ping the target device; the
default value is 1 second. The "Number of attempts" (default: 2) is used to decide
after how many intervals the "Condition" is fulfilled. The "Condition" can be defined
via the drop down list, either "IP unreachable" or "IP reachable".
Then the "Switching Action" is to be selected via the corresponding drop down list
(again, the appropriate Switching Actions (chapter 5.5.7.3.6.1) should have been
defined already) and the trigger needs to be enabled via the "Enabled" check box.
As the last step, click on the button to store the settings made. All
enabled triggers (IP Monitoring triggers and trap triggers) are activated by clicking
on the button.
Note:
The check box labeled "Enabled" is grayed out and the message "Not enabled in
Auto Mode Assignment" appears if "TRAC" is not activated in the drop down
list "Auto Mode Assignment" of the Auto Mode entry (chapter 5.5.7.3.2).
The activated Switching Actions are not checked for ambiguity or contradic-
tions. The behavior of the device is not predictable in such a case.
To copy a trigger click on the icon left to the trash bin icon of the trigger entry.
The copy which is appearing has the same name but with a leading "Copy of"
(which can be renamed by double clicking the name).
To delete a trigger click on the trash bin icon right to the trigger entry.
A window pops up for confirmation.
5.5.7.3.5.3 Trap Log
Copyright DEV Systemtechnik GmbH 2015-2017 85
Page 86
User Manual DEV 1953
This screenshot of the Trap Log was already shown in the description how a trap
trigger can be defined; please refer to chapter 5.5.7.3.5.1. The "Trap Log" table
covers one entry per trap received by the device.
Each line comprises a "Date/Time" stamp, the "Source IP", the "Enterprise OID",
and the "Trap Specific" entries.
After selecting (i.e. clicking on) a specific line the "Variable Bindings" table carries
the specific information of the selected trap, i.e. one (or more) OID(s) with its
(their) value(s).
Note:
The Trap Log remains empty if this device is not configured properly as trap
destination within the device that sends traps (chapter 5.5.7.3.5).
In addition, the TRAC Setup (chapter 5.5.7.3.5.1, description of the upper
section) needs to be configured accordingly.
On the other hand, too many traps received by the device may cause the loss
of clarity within the Trap Log. It is to be considered whether the number of
traps can be reduced by changing communication parameters on both ends of
the transmission chain.
The number of entries within the Trap Log is limited to 30; the oldest entries
are deleted first.
5.5.7.3.6 Actions
The Actions submenu item within the menu item Feature Setup of the Setup Tab
comprises the Switching Actions entry and the Action Log entry.
5.5.7.3.6.1 Switching Actions
The definition of Switching Actions is necessary for the Time Based Switching
functionality and for the TRAC functionality. By setting up an action it can be
defined which switch module is affected and to which port the switch module is to
be commanded.
86 Copyright DEV Systemtechnik GmbH 2015-2017
Page 87
User Manual DEV 1953
After selecting the Switching Actions entry on the left side of the Setup Tab in the
submenu "Actions", click on the item "Add new action" and enter a name in the
appearing text field. When defining actions it is recommended to enter a meaningful name (here: "to 1-1 2-2 3-1 4-2"). This enables a better distinction when
selecting the appropriate action in the setup of the Time Based Switching functionality or in the setup of the TRAC functionality later.
Then select the name in the list to enable the definition of the action (alternatively
and if applicable, click on an existing action to modify it):
The action is defined by selecting the module outputs (via the check boxes below
the "On" label) and then the input port (via the drop down list below the "Input"
label) as the target switching position. Depending on the application, one or more
actions need to be defined.
Note:
Do not forget to click on the button to store the settings made
before selecting (or adding) another action, or before proceeding e.g. with the
Time Based Switching setup (chapter 5.5.7.3.4), or with setting up the TRAC
functionality (chapter 5.5.7.3.5)!
Again, it is recommended to perform Time Based Switching (and TRAC as well)
with the device set to Individual switching mode. If it is intended to switch a
number of switch modules synchronously, rather the definition of an action is
recommended which defines the desired target switch positions for the single
switch modules.
Copyright DEV Systemtechnik GmbH 2015-2017 87
Page 88
User Manual DEV 1953
To copy an action click on the icon left to the trash bin icon of the action entry.
The copy which is appearing has the same name but with a leading "Copy of"
(which can be renamed by double clicking the name).
To delete an action click on the trash bin icon right to the action entry.
A window pops up for confirmation.
Note that an action cannot be deleted if it is used in a trigger definition; a
corresponding message pops up when trying to delete the action:
5.5.7.3.6.2 Action Log
The Action Log captures the Switching Actions performed by the device in Auto
Mode. Per entry, it comprises a "Date/Time" stamp, the "Trigger Type", the
"Trigger Name" causing the action, and the "Action Type" and the "Action Name" of
the performed action.
The screenshot above shows three entries, one for each trigger type, which can
cause a switching action:
IP Monitor
the switching action "to 1-1 2-2 3-1 4-2" was caused by the IP monitor trigger
named "1951 unreachable" (please refer to chapter 5.5.7.3.5.2).
Trap
the switching action "to 1-2 2-2 3-2 4-2" was caused by the trap trigger named
"1951 in Local" (chapter 5.5.7.3.5.1).
Time
the switching action "to 1-1 2-2 3-1 4-2" was caused by a trigger of the Time
Based Switching named "Wednesday 17:45" (chapter 5.5.7.3.4).
88 Copyright DEV Systemtechnik GmbH 2015-2017
Page 89
User Manual DEV 1953
5.5.7.4 Software Service
The Software Service menu item on the left side of the Setup Tab provides access
for users with "admin" permission to the Restore Factory Defaults entry, to the
Data Backup entry, and to the Firmware Update entry.
5.5.7.4.1 Restore Factory Defaults
With a click on the button, the settings of the device are reset
to the factory values as described in chapter 4.3 including all changes on the Web
Interface. To maintain the network setup of the device, activate the check box
"Keep IP Settings" before operating the button. After a click on
, a device reset is initiated indicated via a pop up window, e.g.
Note:
Any data stored via the data backup functionality is not deleted, please refer to
chapter 5.5.7.4.2.
Recorded data (chapter 5.5.6) is deleted only if a different recording interval is
applied than the recording interval default setting (chapter 5.5.7.3.1).
5.5.7.4.2 Data Backup
The data backup functionality provides means to manage various device data.
It is recommended to perform external backups of the device configuration data
periodically (please refer to chapter 4.2.5.1 for a systematic description).
The data backup functionality shows up with a table providing ten lines ("slots")
and with five buttons below the table which are grayed out initially.
The first action is to activate one of the ten slots by clicking on it, which causes the
corresponding line to be highlighted. Additionally, depending on the content of the
Copyright DEV Systemtechnik GmbH 2015-2017 89
Page 90
User Manual DEV 1953
selected slot, two to all of the five buttons become active, thus enabling the data
backup functionality:
After operating the button, the drop down list "Type", the text field
"Description", and a button labeled appear:
With the drop down list, the type of data to be saved can be chosen:
"Module Data"
to store the following data categories for all (!) installed modules:
● "Switch Settings",
● "RF Threshold Settings" (if applicable), and
● "Channel Settings and Names".
Please refer to chapters 5.5.4.1…5.5.4.3 for details on these settings and to the
"Restore" section below for retrieving all or only a part of these settings.
"Device Data"
to store device specific settings accessible via the Setup Tab:
(chapters 5.5.7.2.2, 5.5.7.3.1, 5.5.7.3.2, including the modes (chapter 5.1)).
Please refer to the chapters in parentheses for details on these settings and to
the "Restore" section below for retrieving all or only a part of these settings.
90 Copyright DEV Systemtechnik GmbH 2015-2017
Page 91
User Manual DEV 1953
"Error Log"
to store the current content of the Events Tab (chapter 5.5.5).
Note that "Error Log" data can neither be restored nor be imported!
For better identification, it is recommended to enter a descriptive name for the
backup set in the "Description" text field before operating the button.
In the following screenshot, the first three slots are occupied with a backup set for
each type of data. These backup sets were created in the way as described above.
As indicated, the content of the selected slot determines which of the five buttons
is active or not. In the screenshot above the button is grayed out since it is
not possible to restore the content of an "Error Log" backup set. The
button is active only if either a slot with a backup set containing "Module Data" or
"Device Data" is selected.
Note:
A backup set can only be restored to a device with the same product number.
Otherwise the message "Error: Backup created with different device" appears
instead of the button.
If a backup set containing "Module Data" is selected as shown in the next screenshot and if the button is operated, the available categories (as described
above) are listed. It is possible to (de-)select particular categories via the adjacent
check boxes before operating the button.
Copyright DEV Systemtechnik GmbH 2015-2017 91
Page 92
User Manual DEV 1953
If a backup set containing "Device Data" is selected as shown in the next screenshot
and the button is operated, the available categories (as described above)
are listed. It is possible to (de-)select particular categories via the adjacent check
boxes before operating the button.
After operating the button, the appearing "File" text field permits the
insertion of a filename including the path where the file resides. Alternatively, the
button can be used to locate the file. After the file was selected, a click on
the button activates the file transfer to the device.
Note:
Precondition for the import is a valid backup set containing "Module Data" or
"Device Data", which was generated before via the button (see below),
or which was provided by DEV Systemtechnik.
It is always possible to import a valid backup set containing "Module Data" or
"Device Data" to a selected slot. The information, which is possibly stored in
that slot, is overwritten without any confirmation.
If the imported backup set is to be applied to the device, the button is
to be operated after the import.
92 Copyright DEV Systemtechnik GmbH 2015-2017
Page 93
User Manual DEV 1953
After operating the button a browser specific window pops up and suggests
the storage of the data as "backup_slot_xx" (with "xx" being the number of the slot (i.e.
the line number 01…10 of the table) to be exported). If a backup set contains
"Module Data" or "Device Data", this data is stored in an encoded binary format.
The export of an "Error Log" backup set is stored in text format similar to the
appearance in the Events Tab (chapter 5.5.5).
With the button, the content of the selected slot is deleted without any
confirmation!
5.5.7.4.3 Firmware Update
The Firmware Update entry provides means to update the device firmware,
manuals etc., and/or to reset the device via Web Interface.
Precondition for updating the device firmware is a service package provided by
DEV Systemtechnik.
The input field permits the insertion of a filename including the path where the file
resides. Alternatively, the button can be used to locate the file. After the
selection of the file, a click on the button activates the file transfer to the
device. As soon as the upload is finished, the installation is started, please observe
the text output, which appears in the "Update Status:" text window.
If –for any reason– a device reset is required, the button can be used
to reset the device without updating the firmware.
After a click on the button, a device reset is initiated indicated via a
pop up window, e.g.
Copyright DEV Systemtechnik GmbH 2015-2017 93
Page 94
User Manual DEV 1953
5.5.8 Info Tab
The Info Tab provides information regarding configuration and setup of the device.
This information is mainly intended for support purposes; part of this information
may be requested when contacting DEV Systemtechnik.
In the left column, first the "Hardware Configuration" is described:
Device, here: DEV 1953
MAC Address, here: 00-D0-93-35-B8-D2
The second section in the left column describes the "Software Options"; this device
is equipped with Option 28 (automatic switch back) and with Option 37 (TRAC).
In the right column on the top, the "Software Configuration" is described:
Device Firmware version, here: 32-0071 G.01
Linux Kernel version, here: 3.14.73-S
SNMP Software version, here: 3.1.13
the current IP Address of the device, here: 192.168.0.11
Web Interface Licenses, here: 1
SNMP Licenses, here: 1
A download icon is located on the bottom of the right column for downloading the
electronic version of the user manual.
Finally, in the right column in the middle the manufacturer's name, country and
hyperlink are listed.
94 Copyright DEV Systemtechnik GmbH 2015-2017
Page 95
User Manual DEV 1953
5.6 Control via Remote Interface: Sandar Prosan Protocol
5.6.1 Sandar Prosan Protocol Overview
Messages between the device and the host are transferred as records, i.e. data
between unique start and stop characters. Once a complete record is received, the
receiver returns the character <ACK> if the record is correctly received and recognized. If the record is incorrectly received, not recognized, or not available, the
receiver returns a <NAK> character. If the transmitter receives <NAK> (or no answer
e.g. within two seconds), it retransmits the message. The number of retransmissions and delays before a retransmission varies and depends on the current system.
Each record comprises a checksum that is inserted -as two characters in hexadecimal notation- between the last data character and the stop character of the
record. The checksum is calculated by the modulo 256 sum of all data characters in
the record.
The record start character <STX>, the record stop character <ETX>, the acknowledge
character <ACK>, and the not-acknowledge character <NAK> cannot be transmitted as
data characters.
Note:
The Sandar Prosan protocol is available only if "Prosan" is selected within the
CPH setup of the Web Interface; please refer to chapter 5.5.7.2.3. The protocol
is exclusively available via the serial interface; the settings of the serial interface have to be configured accordingly (chapter 4.4.1.2).
If "Echo in Local Mode" is disabled (factory default), the device responds in
Local Mode with an <ACK> character to the commands Q, XR, AM, AMA, S, or SA,
only. If enabled, the responses are equivalent to the responses in
Remote Mode.
"Echo in Local Mode" can be disabled or enabled within the CPH setup of the
Web Interface or via the device specific PMEy commands (chapter 5.6.3.7).
The device specific PMxy commands (chapters 5.6.3.6…5.6.3.9) are not part of
the protocol standard and can be executed in Remote Mode or in Auto Mode.
For testing purposes, the Sandar Prosan tool WinProTest v1.01 by Telecast
Norge AS may be used to issue Sandar Prosan commands.
5.6.2 Sandar Prosan Protocol Communication Structure
The basic command structure is:
Command:
<STX><command><checksum><ETX>
Notation:
<STX> = record start character (= 0x02)
<ETX> = record stop character (= 0x03)
<ACK> = acknowledge (complete record received) character (= 0x06)
<NAK>= not-acknowledge (incorrect record received) character (= 0x15)
Note:
(Initially) always a <ACK> or <NAK> character is returned as a response to a
command.
The switching command (M, chapter 5.6.3.5) can be executed in Remote Mode
only.
Copyright DEV Systemtechnik GmbH 2015-2017 95
Page 96
User Manual DEV 1953
5.6.3 Sandar Prosan Commands
The different commands for the communication with the device are described next.
5.6.3.1 Status Query (Q)
The status query can be sent at any time to the device
<STX>Q<checksum><ETX>i.e.<STX>Q51<ETX>
The device answer is
<ACK><STX>Q<status_byte><checksum><ETX>e.g.<ACK><STX>Q00B1<ETX>
with the following possible content of the <status_byte>:
00 = Status ok in Remote/Auto Mode
01 = Pending event(s) in Remote/Auto Mode
10 = Status ok in Local Mode
11 = Pending event(s) in Local Mode
5.6.3.2 Query Alarm Messages (AM or AMA)
This is the command for the query of pending events
<STX>AM<checksum><ETX>i.e.<STX>AM8E<ETX>
or
<STX>AMA<checksum><ETX>i.e.<STX>AMACF<ETX>
The device answer is
<ACK><STX>AM001:0000,e{,x
or
<ACK><STX>AMA001:0000,e{,x
with:
e= 00…99 number of events following
{,x
,…,xe}
1
= 00…FF if there are events: error code class (first digit) and
error code sub-class (second digit) in hexadecimal (!) notation,
separated by commas (",")
e.g. <ACK><STX>AM001:0000,00A5<ETX> (no events)
or <ACK><STX>AMA001:0000,02,12,1307<ETX>(power supply & power line event(s))
Note:
The event indication is the upper two hexadecimal digits of the related error
class. The first digit specifies the error class according to chapter 5.9.4.4.2; the
second digit defines the sub-class. The events of the second example are in the
error class "1", i.e. this denotes events in the area of the power supplies, please
refer to chapter 6.1.1. The sub-class of the first indicated event (x1 = 12) is "2",
specifying a "Power Line" event, the sub-class of the second indicated event
(x2 = 13) is "3", specifying a "Power Supply" event.
It is not indicated if there is more than one pending and not acknowledged
event of the same error code class/sub-class.
,…,xe}<checksum><ETX>
1
,…,xe}<checksum><ETX>
1
96 Copyright DEV Systemtechnik GmbH 2015-2017
Page 97
User Manual DEV 1953
5.6.3.3 System Identification (XR)
This command can be issued in order to obtain device information
<STX>XR<checksum><ETX>i.e.<STX>XRAA<ETX>
The device specific identification data is returned in the format
("⌡" and "⌠" are symbolizing that the two consecutive lines are actually one line)
with:
o1 = the input port number of the switch module in the first slot, either
001: primary input port "In A" or
002: secondary input port "In B";
(…)o16 = the input port number of the switch module in the sixteenth slot, either
001: primary input port "In A" or
002: secondary input port "In B".
Note:
It cannot directly be identified via Sandar Prosan protocol whether a slot is
empty or populated with a passive module or with a distribution amplifier
module.
Copyright DEV Systemtechnik GmbH 2015-2017 97
Page 98
User Manual DEV 1953
5.6.3.5 Set Signal Path (M)
This is the command for switching the switch module ooo to the input port iii.
with:
ooo = the switch module number in the range 001…016;
iii = the input port number to which the switch module is to be connected to,
either 001 or 002.
The device confirms the command with an <ACK> if the command is accepted and
with a <NAK> otherwise.
Note:
It is possible to issue a switch command for an empty slot or for a slot
populated with a passive module or with a distribution amplifier module.
Naturally, there is no execution of the switch command.
If a parameter exceeds the permissible range or if the device is not in Remote
Mode, a <NAK> is returned!
5.6.3.6 Select Remote Control Mode (PMCI/PMCE)
Via these device specific commands, the operation mode can be either set to
Auto Mode (PMCI) or to Remote Mode (PMCE); please refer to chapter 5.1.
<STX>PMCI<checksum><ETX>i.e.<STX>PMCI29<ETX>
and
<STX>PMCE<checksum><ETX>i.e.<STX>PMCE25<ETX>
The device confirms both commands with an <ACK> if the command is accepted and
with a <NAK> if the device is in Local Mode.
Note:
If the Auto Mode is activated via the PMCI command, this implies the usage of
the device defined by the Auto Mode Assignment of the Web Interface
(chapter 5.5.7.3.2).
If Auto Mode is activated, no switching command (M, chapter 5.6.3.5) is
executed. The PMCE command has to be issued first, to get back the remote
switching control via Sandar Prosan protocol.
5.6.3.7 Select Echo in Local Mode (PME0/PME1)
Using these device specific commands "Echo in Local" can be
disabled (PME0) or enabled (PME1).
If "Echo in Local" is disabled and if the device is in Local Mode, the device responds
to queries (Q, XR, AM or AMA, S or SA) with an <ACK> character only.
<STX>PME0<checksum><ETX>i.e.<STX>PME012<ETX>
and
<STX>PME1<checksum><ETX>i.e.<STX>PME113<ETX>
The device confirms both commands with an <ACK> if the command is accepted and
with a <NAK> if the device is in Local Mode.
Note:
Alternatively, "Echo in Local" can be enabled or disabled within the CPH setup
of the Web Interface (please refer to chapter 5.5.7.2.3).
The switching mode can be set via these device specific commands to
Individual switching mode (PMOI) or to Simultaneous switching mode (PMOS),
please refer to chapter 5.1.4.
<STX>PMOI<checksum><ETX>i.e.<STX>PMOI35<ETX>
and
<STX>PMOS<checksum><ETX>i.e.<STX>PMOS3F<ETX>
The device confirms both commands with an <ACK> if the command is accepted and
with a <NAK> otherwise. The commands are rejected in Local Mode and the PMOS
command is rejected in Remote Mode or Auto Mode if the preconditions for Simultaneous switching mode are not given. This means that all members of all groups
(with two or more members) have to be in the same switch position; i.e. all switch
modules of a group are switched to the primary or to the secondary input port
(chapter 5.1.4).
5.6.3.9 Select Power Supply Monitoring Mode (PMP0/PMP1)
With these device specific commands the power supply monitoring can be
disabled (PMP0) or enabled (PMP1).
If disabled, the reporting of all power supply events via the query command AM (or
AMA) (please refer to chapter 5.6.3.2) including the Q command (chapter 5.6.3.1) is
suppressed.
<STX>PMP0<checksum><ETX>i.e.<STX>PMP01D<ETX>
and
<STX>PMP1<checksum><ETX>i.e.<STX>PMP11E<ETX>
The device confirms both commands with an <ACK> if the command is accepted and
with a <NAK> if the device is in Local Mode.
Note:
The successful execution of these commands modifies bit 1 of the SNMP
.errorEnableMask (chapter 5.9.4.4.2).
Copyright DEV Systemtechnik GmbH 2015-2017 99
Page 100
User Manual DEV 1953
5.7 Control via Remote Interface: Leitch Protocol
5.7.1 Leitch Protocol Overview
Like the Sandar Prosan protocol, the implementation of the Leitch protocol provides a standard for the communication between the device and a host. The interface can be used for the monitoring and for the switching of the device. Within the
Leitch protocol standard it is distinguished between two protocol modes: the Leitch
Terminal Protocol and the Leitch Pass-Through Protocol. DEV Systemtechnik has
implemented a subset of the Leitch Pass-Through Protocol. Only one Leitch
Terminal Protocol command is implemented: "Enable Reporting" is the command
to switch to the Leitch Pass-Through Protocol mode.
The Leitch protocol is implemented to work via TCP/IP on port 23 (standard Telnet
port), and/or via the serial interface.
Note:
The Leitch protocol is available only if "Leitch" is selected within the CPH setup
of the Web Interface; please refer to chapter 5.5.7.2.3. If it is intended to use
the serial interface to control the device via Leitch protocol, the settings of the
serial interface have to be configured accordingly (chapter 4.4.1.1).
If "Echo in Local Mode" is disabled (factory default), the device responds in
Local Mode with the Leitch Error Message (see below) to any valid Leitch command which returns a response in Remote Mode. If enabled, the responses are
equivalent to the responses in Remote Mode. "Echo in Local Mode" can be enabled or disabled within the CPH setup of the Web Interface.
The Leitch protocol implementation on this device distinguishes between "Indi-
vidual Switch Level Assignment" being enabled (factory default) or disabled.
The selection is performed via a check box in the CPH setup of the Web Interface and has impact on the behavior of the "Request Crosspoint Status" command (chapter 5.7.4.5), and on the behavior of the "Direct Crosspoint Take"
switching command (chapter 5.7.4.6).
Basically the selection alters the perspective on the arrangement of the switch
modules within Leitch levels (<Lvl>) and destinations (<Dest>) in Individual
switching mode:
(a) If "Individual Switch Level Assignment" is enabled, the single switch
modules are addressed via the level, the destination is always "0", i.e.
- Level 0/Destination 0 ≡ the switch module in the first slot,
- Level 1/Destination 0 ≡ the switch module in the second slot,
- Level 2/Destination 0 ≡ the switch module in the third slot, (…).
(b) If "Individual Switch Level Assignment" is disabled, the level is assigned to
the groups and the destination is assigned to the single switch modules.
Some examples:
- Level 0/Destination 0 ≡ the first switch module within Group 1,
- Level 0/Destination 1 ≡ the second switch module within Group 1, and
- Level 1/Destination 1 ≡ the second switch module within Group 2.
(c) In Simultaneous switching mode there is no distinction whether "Individual
Switch Level Assignment" is enabled or disabled. In both cases, the level is
assigned to the groups and the destination is assigned to the single switch
modules according to perspective (b).
100 Copyright DEV Systemtechnik GmbH 2015-2017
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.