Chapter 4. 20
For code 1 it bypasses this option and points to code name (code 1
is always a master code).
For code 2 and above press the NO key until display reads the code type required. (Master, Main,
Clnr, Area 1,Area 2, Area 3, Duress, Holder and On/Off [Clnr = cleaner]). When the code type
required is displayed press the YES/PART key to accept and the > points away. (See System Features)
Press the YES/PART key to accept a user’s name and repeat for next code.
To program in a user’s identification name press the NO key, refer to the
keystroke/character chart and press the keys required. I.e. for Bill, press the
1 key five times, YES/PART key, the 3 key three times, YES/PART key
the 4 key three times the YES/PART key then the 4 key three times. (To correct a error press the
YES/PART key followed by the NO key) To complete press the YES/PART key until next code is
displayed. To make a space press the YES/PART key twice. (Version 5000 or later software, Quick
escape, Press the 0/ESC key followed by YES/PART key, or quick delete of full name, press 0/ESC key
followed by NO).
On completion of programming of the codes, press the 0/ESC key.
For mode 2 area operation, version 5000 software or later, the following
programming is available.
This menu selects the area that the main code and duress codes will set and
unset. To select press the NO key until main = area numbers required, then
press the YES/PART key to accept. Repeat for Duress (Software version
5000 only) on pressing the YES/PART key the display changes to:
Press the 4 key to return to the day mode and check that the new number(s)
works and any old number(s) is/are deleted, or press the number displayed,
for function required.
Notes. Codes can only be programmed/deleted by the master code.
One master code (code 1) is the minimum number of user codes for the system.
Code 1 is factory default as 1234; it should be changed from this number to one that only
you know, as soon as possible for the security of the installation. It is advised not to use
consecutive or numbers like 1066 that can be easily compromised.
When area’s are used, a minimum of one master code and one code for each area
used must be programmed for correct operation of the installation.
When programming codes it is recommended that names, or idents, are prgrammed for
each code, for identification of which code user operated the system.
New numbers only become active on return to the day mode.
If a number has already been programmed as a code and you attempt to program the
same number again, code conflict will be detected (erro tone sounded and code displayed
removed) and prevent that number being used, retype in a different number or press the
YES/PART key to carry on programming.
Delete a User Code
ONLY A MASTER CODE CAN DELETE A USER CODES.
Should you attempt to delete code 1, it will revert to the factory default of 1234.
From the day mode, enter the User Master code (1234).
Code 1 654321
Master >Bill