Designplan ACQUASTOP BRIGHT 2.6, ACQUASTOP BRIGHT 2.7 Installation Instructions Manual

BRIGHT 2.6 - 2.7 -ACQUASTOP-
Installation instructions
Designplan Lighting, Inc., 79 Trenton Ave., Frenchtown NJ, 08825. T.908-996-7710 F.908-996-7042
3.15"
IP67
3.35"
3.35"
Kg0.50
Pag. 1 - rev.00
 WARNING!!!
Please read the following instructions carefully.
IMPORTANT:
Although LED runs on a very low voltage, always cut off the power sup-
ply before installing the LED light or subjecting it to maintenance.
Unauthorised alterations or tampering of the product will invalidate all
the conditions of guarantee.
This fixture must be installed by a qualified electrician.
Designplan is not resposable if its fixtures are not installed in
according to local safety standards. Data contained in this document may be changed at any moment with-
out prior notice.
ELECTRICAL CONNECTIONS:
LED lights run at constant current.
LED lights must be connected in parallel respecting polarities.
As for the choice of the power supplies, please consider the tension
through which they are fed and the max power consumption of LEDs you have to install.
The system must be fed only if all the spots are connected.
The power supplies must be installed in aerated rooms, far from heat
sources. A situation of overworking or a lack of air circulation will not permit a natural dissipation.
Under no circumstance must this product be covered by thermalisolating
material or similar.
3.35"
3.15"
NOTES:
Wire connections must be made with water-proof wire
nuts or similar.
Designplan Lighting, Inc., 79 Trenton Ave., Frenchtown NJ, 08825. T.908-996-7710 F.908-996-7042
+DESIGN
BRIGHT 2.6 - 2.7 -ACQUASTOP-
Installation instructions
IP67
3.35"
Kg0.50
Designplan Lighting, Inc., 79 Trenton Ave., Frenchtown NJ, 08825. T.908-996-7710 F.908-996-7042
Pag. 2 - rev.00
.51"
3.07"
1.85"
2.28"
2.71"
PARALLEL connection
LAMP
THE SYSTEM MUST BE ENERGIZED ONLY AFTER ALL THE
IN PARALLEL RESPECTING POLARITIES.
LAMP LAMP
LED LIGHTS MUST BE CONNECTED
WARNING!!!
FIXTURES ARE CONNECTED.
2.83"
1
3.94"
4.17"
2
POWER CONSUMPTION
SUPPLY VOLTAGE
CONNECTION
N° AND TYPE OF LED USED
AVERAGE LED LIFE 75% after 50.000 hours
LED COLOURS AVAILABLE
CRI
TYPICAL LUMINOUS FLUX
OPERATING TEMPERATURE
FINISHING Aluminum, Inox steel
FIXING
APPLIANCE CLASS
WEIGHT
3x1W; 3x2W;
12/24 Vdc
Parallel connections: provided with a 59" cable.
3 power LED
White: 2700K; 3000K; 4000k: 5000K; blue
80
90 lm/W
-10°C ÷ +45°C
Recessed, outer-casing WC0103 not included.
CLASS 2
0.50kg
3
Observe Polarity!
RED/BROWN
BLACK/BLUE
WATERTIGHT CONNECTION
1,5 mt
IPS
Do not cut!!!
Designplan Lighting, Inc., 79 Trenton Ave., Frenchtown NJ, 08825. T.908-996-7710 F.908-996-7042
IPS
+DESIGN
BRIGHT 2.6 - 2.7 -ACQUASTOP-
Installation instructions
Designplan Lighting, Inc., 79 Trenton Ave., Frenchtown NJ, 08825. T.908-996-7710 F.908-996-7042
4
IP67
Kg0.50
Pag. 3 - rev.00
WARNINGS
INSTRUCTIONS FOR CORRECT WASTE DISPOSAL
According to art. 13 of the Legislative Decree dated 25 July 2005 n. 151 concerning CE directions on the use and disposal of electronic and elec­tronical materials.
The symbol of the crossed rubbish skip you find on the device or its packaging indicates that once the product had been used, it must be collected separately from other waste material. As a consequence, users are supposed to bring the useless device to the differentiated waste disposal centres of electronic and electrotechnical materials. Alternatively, you can hand it back to the reseller when you buy a new equivalent device. The correct differentiated waste collection in order to recycle the disused device, to treat it and get rid of it contributes to avoid possible bad consequences on the environment and health while it favours the re-employment of the materials the device is made of. The illegal waste disposal of the device from its holders causes the application of the admin­istrative sanctions foreseen by the regulations in force.
Designplan Lighting, Inc., 79 Trenton Ave., Frenchtown NJ, 08825. T.908-996-7710 F.908-996-7042
+DESIGN
Loading...