Design Dynamics VTD-18NV-JHB, VTD-24NV-JHB, VTD-18PV-JHB, VTD-30NV-JHB, VTD-30PV-JHB Owner's Operation And Installation Manual

VENTED DECORATIVE APPLIANCE
PFS
US
OWNER’S OPERATION AND INSTALLATION MANUAL
®
MODELS VTD-18NV-JHB, VTD-18PV-JHB, VTD-24NV-JHB,
VTD-24PV-JHB, VTD-30NV-JHB AND VTD-30PV-JHB
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
— Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
TABLE OF CONTENTS
Safety .................................................................. 2
Product Identication ........................................... 4
Local Codes......................................................... 5
Unpacking............................................................ 5
Product Features ................................................. 5
Optional Accessories ........................................... 5
Installation ........................................................... 5
Operation ........................................................... 10
Inspecting Burners............................................. 12
Cleaning and Maintenance ................................ 12
SAFETY
Troubleshooting ................................................. 13
Specications .................................................... 17
Wiring Diagrams ................................................ 18
Service Hints ..................................................... 18
Technical Service............................................... 18
Replacement Parts ............................................ 19
Accessories ....................................................... 19
Parts .................................................................. 20
Warranty ..............................................Back Cover
WARNING: Improper instal-
lation, adjustment, alteration,
service or maintenance can
cause injury or property damage.
Refer to this manual for correct
installation and operational procedures. For assistance or
additional information consult a
qualied installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
WARNING: This appliance
is for installation only in a
solid-fuel burning masonry or UL127 factory-built replace, constructed of noncombustible
material and connected to a
working ue. (See page 6 for minimum ue opening.)
WARNING: This is a gas-red heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combus­tion and ventilation air must be provided. Refer to the National
Fuel Gas Codes, ANSI Z233.1/ NFPA 54, Air for Combustion and Ventilation.
State of Massachusetts: The
installation must be made by a licensed plumber or gas tter in the Commonwealth of Massachusetts.
WARNING: This product con­tains and/or generates chemicals
known to the State of California
to cause cancer or birth defects or other reproductive harm.
WARNING: Keep ue open when operating unit.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op­erate or service this log set. Improper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.
www.fmiproducts.com
114370-02H2
SAFETY
Continued
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
u, with headaches, dizziness or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once!
Have log set serviced. Some people are more affected by carbon monoxide than oth-
ers. These include pregnant women, people with heart or lung disease or anemia, those under the inuence of alcohol and those at
high altitudes. Natural and Propane/LP Gas: Natural and
propane/LP gas are odorless. An odor-making agent is added to the gas. The odor helps you
detect a gas leak. However, the odor added to the gas can fade. Gas may be present even
though no odor exists. Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of this log set.
WARNING: Any change to this log set or its controls can be dangerous.
Do not place clothing or other ammable material on or near the appliance. Never place any objects on the heater.
Appliance base assembly be­comes very hot when running. Keep children and adults away from hot surface to avoid burns or clothing ignition. Log set
will remain hot for a time after
shutdown. Allow surface to cool before touching.
Carefully supervise young chil-
dren when they are in the room
with log set. When using hand­held remote accessory keep se­lector switch in the OFF position to prevent children from turning on burners with remote.
You must operate this log set with a replace screen in place. Make sure replace screen is closed before running log set.
WARNING: Do not use a blow­er insert, heat exchanger insert or other accessory not approved for use with this appliance.
WARNING: This appliance is equipped for use with type of gas indicated on rating plate.
Keep the log set area clear and free from combustible materials, gasoline and other ammable vapors and liquids.
Children and adults should be alerted to the hazard of high temperature and should stay away to avoid burns or clothing
WARNING: Do not allow fans
to blow directly into the replace. Avoid any drafts that alter burner ame patterns.
ignition.
1. Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors (propane/LP units only).
Due to high temperatures, the appliance should be located out of trafc and away from furniture and draperies.
114370-02H 3
www.fmiproducts.com
SAFETY
Continued
2. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from a neighbor’s phone. Follow the gas sup-
plier’s instructions
• if you cannot reach your gas supplier, call the re department
3. Never install the log set
• in a recreational vehicle
• where curtains, furniture, clothing or other ammable objects are less than 42" from the front, top or sides of the log set.
• in high trafc areas
• in windy or drafty areas
4. Before installing in a solid fuel burning re­place, the chimney ue and rebox must be cleaned of soot, creosote, ashes and loose paint by a qualied chimney cleaner. Creosote will ignite if highly heated. Inspect chimney ue for damage. If damaged, repair ue before operating appliance.
5. Do not operate heater if any log is broken. Do not operate heater if a log is chipped
(dime-sized or larger).
6. This log set is designed to be smokeless.
If logs ever appear to smoke, turn off appli­ance and call a qualied service person.
Note: During initial operation, slight smok-
ing could occur due to log curing and the burning of manufacturing residues. You may wish to add more ventilation by opening a window.
7. To reduce the creation of soot, follow the
instructions in Cleaning and Maintenance, page 13.
8. The installation and provisions for com­bustion and ventilation air must conform
with the National Fuel Gas Codes, ANSI Z233.1/NFPA 54, Air for Combustion and Ventilation.
9. To prevent performance problems, do not
use propane/LP fuel tank of less than 100 lb. capacity (propane/LP units only).
10. Do not run log set
• where ammable liquids or vapors are
used or stored
• under dusty conditions
11. Do not burn solid fuel in the replace after
installing the log set. Do not use this log set to cook food or burn paper or other
objects.
12. Do not use heater if any part has been ex-
posed to or under water. Immediately call a qualied service technician to inspect
the room heater and to replace any part of the control system and any gas control
which has been under water.
13. Turn log set off and let cool before servic-
ing, installing or repairing. Only a qualied service person should install, service or
repair log set.
14. Provide adequate clearances around air openings.
15. This vented gas log set may not be in­stalled in a bedroom or bathroom in the
Commonwealth of Massachusetts.
PRODUCT IDENTIFICATION
WARNING: Failure to posi­tion the parts in accordance with these diagrams or failure to use only parts specically approved with this appliance may result in property damage or personal injury.
www.fmiproducts.com
Grate
Ceramic Burner
Chassis Assembly
Figure 1 - Product Identication
Control
Knob
Log Set Assembly
Piezo
Ignitor
ON/OFF
Switch
114370-02H4
LOCAL CODES
Install and use log set with care. Follow all local codes. In the absence of local codes, use the
latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54*
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Battery march park
Quincy, MA 02269
UNPACKING
CAUTION: Do not remove the
data plates from the grate as­sembly. The data plates contain important warranty and safety information.
1. Remove log set assembly from carton.
Note: Do not pick up assembly by logs. This could damage unit. Always handle assembly by grate.
2. Remove control cover oor media compo­nents.
3. Remove all protective packaging applied to log set for shipment.
4. Check heater for any shipping damage. If
heater is damaged call FMI PRODUCTS,
LLC at 1-866-328-4537 for replacement parts before returning to dealer.
PRODUCT FEATURES
This unitized log set is tested and approved
to ANSI Z21.60 and CSA 2.26 as a vented decorative appliance.
PIEZO IGNITOR
This unit has a piezo ignitor. This system re­quires no matches, batteries or other sources
to light appliance.
INSTALLATION
WARNING: Before installing in a solid fuel burning replace, the chimney ue and rebox must be cleaned of soot, creo­sote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney ue may create and distribute soot within the house. Inspect chimney ue for damage. If damaged, repair ue damper before operating appliance.
WARNING: Make sure selec-
tor switch is in the OFF position before installing appliance.
OPTIONAL ACCESSORIES
• VTD-HLCN/P - Converts valve from ON/
OFF to HI/LO
• OFSM-RCN/P - Converts valve from ON/ OFF to HI/LO for use with hand-held ON/
OFF remote (included)
• OF-RC - Converts ON/OFF valve for use with hand-held ON/OFF remote
See Accessories, page 19.
NOTICE: Installation, service and
repair of this appliance must be performed by a qualied installer, service agency, company or gas supplier experienced with this type of gas appliance. Only factory authorized components listed in these instructions may be used
in accordance with the manufac­turer's instructions and all codes
and requirements of the authority having jurisdiction. Any modica-
tions to or use of unauthorized
components or accessory items will void the manufacturer’s war-
ranty and may result in a hazard-
ous condition.
114370-02H 5
www.fmiproducts.com
INSTALLATION
Continued
WARNING: Do not place lava
rocks and log scraps on burner.
CHECK GAS TYPE
Use the correct gas type (natural or propane/ LP) for your unit. If your gas supply is not cor-
rect, DO NOT install this into your replace. See the dealer where you bought the appli-
ance for proper type.
WARNING: This appliance is equipped for either natural gas or propane/LP gas but not both. Gas type is indicated on the rat­ing plate. Field conversion is not permitted.
INSTALLATION AND CLEARANCES
The charts in Figure 2 indicate technical information regarding the installation of your gas log set. Please make sure that all of the
specications shown are applicable before
installation is attempted.
MINIMUM FIREBOX SIZES
MODEL
VTD-18NV-JHB VTD-18PV-JHB VTD-24NV-JHB VTD-24PV-JHB VTD-30NV-JHB VTD-30PV-JHB
*At depth indicated
LOG SIZE
INCHES NO. INCHES NO.
29 3/4" 20" 15 1/2" 18"
BURNER ORIFICE
NATURAL PROPANE/LP
18" 0.1495 25 0.0935 42 24" 0.1570 22 0.0980 40 30" 0.1660 19 0.1015 38
SPECIFICATIONS (W.C.)
FUEL INLET PRESSURE
MIN. MAX.
NG 5" 10.5" 3.5 LP 11 " 14" 10
Figure 2 - Technical Information Charts
BACK
WIDTH
FRONT
WIDTH*
DEPTH
28" 16" 14" 18"
36" 27" 18" 18"
MANIFOLD
PRESSURE
HEIGHT
FLUE OPENING SPECIFICATIONS
Note: This vented appliance must be installed
only in a solid-fuel burning replace construct­ed of noncombustible material. The replace must include a ue and venting system with
the minimum openings shown in Figure 3.
BTU
MODEL BURNER
VTD-18NV-JHB VTD-18PV-JHB
VTD-24NV-JHB VTD-24PV-JHB
VTD-30NV-JHB VTD-30PV-JHB
18" Ramp 59,000 8" dia.
24" Ramp 69,000 8" dia.
30" Ramp 74,000 8" dia.
INPUT
MIN. VENT
OPENING
Figure 3 - Specications
VENTING SPECIFICATIONS FOR INSTALLATION
The replace chimney ue and vent must be
drafting properly. To check the vent for proper
drafting: Light a tightly rolled newspaper on
one end and place it at the inside front edge
of the replace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the ame and remove any obstruc-
tion until proper venting is achieved.
The chimney ue must have a minimum free air opening of 43" during operation of this log set. A damper clamp is provided to x the damper
in position.
The minimum ue sizes shown in Figure 2 are
based on a 6' chimney height using round pipe.
Your minimum ue size will vary based on input
rate and chimney height. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section
6.6, for details.
For Massachusetts Residents Only
Installation of this vented gas log set in the
Commonwealth of Massachusetts requires
the damper be permanently removed or
welded in the fully open position.
INSTALLING DAMPER CLAMP
Secure the damper stop clamp to the edge
of the damper as shown in Figure 4, page 7. If for any reason this clamp doesn't work on your replace, another suitable clamp or per­manent stop must be installed, or the damper
blade must be cut or removed.
www.fmiproducts.com
114370-02H6
Damper Clamp
Damper Clamp
Damper
INSTALLATION
Continued
Damper
Damper
2. Position appliance in replace.
3. Connect to gas supply. See Connecting To Gas Supply, page 8.
Flexible Gas Hose (If Allowed by Local Codes)
Gas
Control
Valve
Masonry
Fireplace
Figure 4 - Attaching Damper Clamp
Manufactured
Fireplace
INSTALLING APPLIANCE ASSEMBLY
WARNING: If installing in a sunken replace, special care is needed. You must raise the replace oor to allow access to appliance control panel. This will insure adequate air ow and guard against sooting and controls being damaged. Raise replace oor with noncombus­tible material. Make sure material is secure.
CAUTION: Do not pick up ap­pliance assembly by logs. This could damage unit. Only handle assembly by grates.
IMPORTANT: Make sure the appliance is level.
If unit is not level, unit will not work properly.
Installation Items Needed• control cover kit (provided with appliance)
• approved flexible gas hose and fittings (provided with appliance) (if allowed by local
codes)
• sealant (resistant to propane/LP gas, not
provided)
1. Apply pipe joint sealant lightly to male
threads of gas tting (not provided). Con­nect approved exible gas hose to inlet
side of gas control valve (see Figure 5).
Figure 5 - Attaching Flexible Gas Hose to
Gas Control Valve
CONNECTING TO GAS SUPPLY
WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualied ser­vice person must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect
propane/LP replace directly to the propane/LP supply. This unit requires an external regulator (not supplied). Install the exter­nal regulator between the unit and propane/LP supply
WARNING: Never connect
natural gas replace to private (non-utility) gas wells. This gas
is commonly known as wellhead
gas.
114370-02H 7
www.fmiproducts.com
INSTALLATION
Continued
Installation Items Needed
Before installing log set, make sure you have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved exible gas line with gas connec­tor (if allowed by local codes) (provided)
* An equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge connection. Purchase the optional equipment shutoff valve from your dealer.
For propane/LP units, the installer must
supply an external regulator. The external
regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, regulator dam­age could occur. Install external regulator with the vent pointing down as shown in Figure 6. Pointing the vent down protects it from freez-
ing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Inter­nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.
Installation must include an equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up.
NPT tap must be upstream from log set (see Figure 7).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Check your building codes for any special requirements for locating equipment shutoff
valve to replaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could result in clogged heater valves.
WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
Propane/LP Tank
External
Regulator with Vent Pointing Down
Figure 6 - External Regulator with Vent
Approved
Flexible Gas Hose (If allowed
by local codes)
* Purchase the optional shutoff valve from your dealer.
** Minimum inlet pressure for purpose of input
adjustment.
Pointing Down
Equipment Shutoff Valve with 1/8" NPT Tap*
Propane/LP Gas
From External
Regulator (11" W.C.** to 14" W.C.
3" Min.
Pipe Cap Tee
Nipple Joint
Sediment Trap
Figure 7 - Gas Connection
Natural Gas
From Gas Meter (5" W.C.** to 10.5"
W.C. Pressure)
www.fmiproducts.com
114370-02H8
Loading...