WARNING: Improper installation, adjustment, alteration,
service or maintenance can
cause injury or property damage.
Refer to this manual for correct
installation and operational
procedures. For assistance or
additional information consult
a qualified installer, service
agency or the gas supplier.
This appliance is only for use
with the type of gas indicated on
the rating plate. This appliance
is not convertible for use with
other gases, unless a certified
kit is used.
State of Massachusetts: The
installation must be made by a
licensed plumber or gas fitter
in the Commonwealth of Massachusetts.
WARNING: This product
contains and/or generates
chemicals known to the State
of California to cause cancer or
birth defects or other reproductive harm.
IMPORT ANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate or service this fireplace.
Improper use of this fireplace
can cause serious injury or death
from burns, fire, explosion,
electrical shock and carbon
monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
This vented gas fireplace is a sealed combustion gas fireplace designed for residential applications. This fireplace must be installed with
FMI PRODUCTS, LLC vent pipe components
and terminations.
Outside airflex installation is
required for both horizontal and
vertical installation.
This fireplace complies with the National
Safety Standards and is listed and tested by
the PFS Corporation. to ANSI Z21.50/CSA
2.22 standard as vented gas fireplace.
This fireplace must be installed by a qualified
(certified or licensed) service person. It brings
in fresh air for combustion through the outer
pipe and combustion gases are exhausted
through the inner pipe. If the glass door assembly and venting pipe are not properly
seated, connected and sealed, carbon monoxide leakage (spillage) can occur.
www.fmiproducts.com
125077-01B2
SAFETY
Continued
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
flu, with headaches, dizziness or nausea. If
you have these signs, the fireplace may not
be working properly. Get fresh air at once!
Have fireplace serviced. Some people are
more affected by carbon monoxide than others. These include pregnant women, people
with heart or lung disease or anemia, those
under the influence of alcohol and those at
high altitudes.
Natural and Propane/LP Gas: Natural and
propane/LP gas are odorless. An odor-making
agent is added to the gas. The odor helps you
detect a gas leak. However, the odor added to
the gas can fade. Gas may be present even
though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this fireplace.
WARNING: Any change to
this fireplace or it’s controls can
be dangerous. Do not modify
this fireplace under any circum-
stances. Any parts removed for
servicing must be replaced prior
to operating fireplace.
WARNING: Do not use a blower insert, heat exchanger insert
or other accessory not approved
for use with this fireplace.
WARNING: This appliance
is only for use with the type of
gas indicated on the rating plate.
This appliance is not convertible
for use with other gases unless
a certified kit is used.
WARNING: Do not allow fans
to blow directly into the fireplace.
Avoid any drafts that alter burner
flame patterns.
125077-01B3
www.fmiproducts.com
Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.
Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the appliance.
Do not use this fireplace to cook
food or burn paper or other flam-
mable material.
This fireplace reaches high tem-
peratures. Keep children and
adults away from hot surface to
avoid burns or clothing ignition.
Fireplace will remain hot for a
time after shutdown. Allow surface to cool before touching.
Carefully supervise young children when they are in the room
with fireplace.
Keep the area around your
fireplace clear of combustible
materials, gasoline and other
flammable vapor or liquids. Do
not run fireplace where these
are used or stored.
1. For propane/LP fireplace, do not place
propane/LP supply tank(s) inside any
structure. Locate propane/LP supply
tank(s) outdoors. T o prevent performance
problems, do not use propane/LP fuel tank
of less than 100 lb. capacity.
2. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier's instructions
• if you cannot reach you gas supplier, call
the fire department.
SAFETY
Continued
3. Never install the fireplace
• in a recreational vehicle
• in windy or drafty areas where curtains or
other combustible (flammable) objects can
make contact with the fireplace front
• in high traffic areas
4. Turn fireplace off and let cool before
servicing, installing or repairing. Only a
qualified service person should install,
service or repair this fireplace. Have fire-
place inspected annually by a qualified
service person.
5. You must keep control compartments,
burners and circulating air passages
clean. More frequent cleaning may be
needed due to excessive lint and dust
from carpeting, bedding material, etc.
Turn off the gas valve and pilot light before
cleaning fireplace.
6. Have venting system inspected annually by
a qualified service person. If needed, have
venting system cleaned or repaired. See
Cleaning and Maintenance, page 25.
LOCAL CODES
Install and use fireplace with care. Follow all
local codes. In the absence to local codes,
use the current National Fuel Gas Code ANSI
Z223.1/NFPA 54* (USA) or the current CSAB149.1 Installation Code (Canada).
PRODUCT IDENTIFICATION
Nailing Flange
7. Do not use any solid fuels (wood, coal,
paper, cardboard, etc.) in this fireplace.
Use only the gas type indicated on fire-
place nameplate.
8. This appliance, when installed, must be
electrically grounded in accordance with
local codes or, in the absence of local
codes, with the National Electrical Code,
ANSI/NFPA 70 or Canadian Electrical
Code, CSA C22.1.
9. Do not use fireplace if any part has been
exposed to or under water. Immediately
call a qualified service person to arrange
for replacement of the unit.
10. Do not operate fireplace if any log is
broken.
11. Do not operate fireplace with glass door
removed, cracked or broken.
12. Provide adequate clearances around air
openings.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Flue Collar
Outer Glass Door
Standard Brick
Refractories
Aniron
Log Set
Center Brick/
Control Cover
Figure 1 - Direct Vent Fireplace (DVF-36NSR-C Shown)
www.fmiproducts.com
125077-01B4
PRODUCT FEATURES
These are a few facts that can help you understand and enjoy your direct vent fireplace:
• The venting system may be routed to the
outside of your home in several ways. It
may vent through the roof (vertical) or it
may vent to an outside/exterior wall (horizontal). The vent pipe installation is very
important to allow for proper operation.
You must follow the venting instructions
very carefully for either vertical or horizontal
applications.
• This fireplace may be installed in any room
of your house provided all local codes and
these installation instructions are followed.
PRE-INSTALLATION
LOCA TION AND SPACE
REQUIREMENTS
Determine the safest and most efficient location for your direct vent fireplace. Make sure
that rafters and wall studs are not in the way of
the venting system. Choose a location where
the heat output is not affected by drafts, air
conditioning ducts, windows or doors. Figure
2 shows some common locations. Be aware
of all restrictions and precautions before
deciding the exact location for your fireplace
and termination cap.
When deciding the location of your fireplace,
follow these rules:
• Do not connect this fireplace venting to a
chimney flue serving a separate solid-fuel
burning fireplace or appliance.
• Due to high temperatures, do not locate this
fireplace in high traffic areas, windy or drafty
areas or near furniture or draperies.
• Proper clearances must be maintained.
Flush with a wall
• Each time you turn on your fireplace, you
may notice some amount of condensation
on the inside of the fireplace glass. This
is normal and will disappear after 10-20
minutes of operation.
• Your direct vent gas fireplace system
(fireplace and venting) is a balanced and
sealed gas operating unit. It requires approximately 10-20 minutes of operating
time before the flame pattern stabilizes.
• Models ending in -C have a standard glass
inner door. Models ending in -CC have the
standard glass inner door with a middle
glass door and outer cool touch glass
door.
• If your fireplace is to be installed directly on
carpeting, vinyl tile or any combustible material other than wood, it must be installed on a
metal or wood panel extending the full width
and depth of the fireplace (see Figure 3).
• Your fireplace is designed to be used in
zero clearance installations. Wall or framing material can be placed directly against
any exterior surface on back, sides or top
of your fireplace, except where standoff
spacers are integrally attached. If standoff
spacers are attached to your fireplace,
these spacers can be placed directly
against wall or framing material. See framing details, page 6.
• When locating termination cap, it is important to observe the minimum clearances
shown in Figure 7, page 7.
• If recessing into a wall, you can avoid extra
framing by positioning your fireplace against
an already existing framing member.
• Do not recess termination cap into a wall
or siding.
• You may paint the termination cap with
450º F (232º C) heat-resistant paint to
coordinate with the exterior finish.
• There must not be any obstruction such as
26"
Through exterior wall
enclosed in a chase
Corner
installation
Figure 2 - Common Fireplace Locations
125077-01B5
www.fmiproducts.com
27 5/8"
D
Figure 3 - Fireplace Bottom Dimensions
RW
43"
PRE-INSTALLATION
Continued
bushes, garden sheds, fences, decks or
utility buildings within 24" from the front of
the termination cap and the front of outside
air vent.
• Do not locate termination cap and outside
air vent where excessive snow or ice build
up may occur. Be sure to clear vent termination area after snow falls to prevent
accidental blockage of venting system.
When using snow blowers, do not direct
snow towards vent termination area.
CLEARANCES
Minimum clearances to combustibles for the
fireplace are as follows:
*Back and sides 0"
Perpendicular walls 6"
Floor 0"
Ceiling to louver opening
Front 36"
Top of Standoffs 0"
Vent (See venting instructions
for specific venting
clearances.)
Combustible material with a maximum thickness of 5/8" may be flush with the top front
of fireplace.
* For back and sides of fireplace, do not pack
with insulation or other materials. 0" clearance to combustible materials are for framing
purpose only.
NOTICE: This fireplace is intended for use as supplemental heat.
Use this fireplace along with
your primary heating system.
Do not install this fireplace as
your primary heat source. If you
have a central heating system,
you may run system’s circulating blower while using fireplace.
This will help circulate the heat
throughout the house.
FRAMING AND FINISHING
Figure 4 shows typical framing of this fireplace.
Figure 5 shows framing for corner installation.
All minimum clearances must be met.
If you are using a separate combustible man-
42"
www.fmiproducts.com
tel piece, refer to Figure 6 for proper installation height. You can install noncombustible
mantels at any height above the fireplace.
A = clearance above grade, veranda, porch, deck, or
balcony [*12" (30.5 cm) minimum]
B = clearance to window or door that may be opened
[6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US
if between 10,000 and 50,000, 12" (30 cm) in Canada
if between 10,000 and 100,000; 12" (30 cm) in US if
greater than 50,000, 36" (91 cm) in Canada if greater
than 100,000]
C = clearance to permanently closed window
[minimum 12" (30.5 cm) recommended to prevent
condensation on window]
D = vertical clearance to ventilated soffit located above the
terminal within a horizontal distance of 24" (61 cm) from
the center-line of the terminal [18" (45.7 cm) minimum]
E = clearance to unventilated soffit [12" (30.5 cm) minimum]
F = clearance to outside corner (see below)
G = clearance to inside corner (see below)
H = *not to be installed above a meter/regulator assembly
within 36" (91.4 cm) horizontally from the center line
of the regulator
† vent shall not terminate directly above a side-walk or paved driveway which is located between two
single family dwellings and serves both dwellings*
‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor*
* as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.
Note: Local codes or regulations may require different clearances
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
Inside Corner
A
A = 6" (15.2 cm)
V
C
F
V
B
TERMINATION CAP
V
Fixed
Closed
Openable
V
Openable
B
AIR SUPPLY INLET
X
B
Fixed
Closed
B
J
V
X
A
I = clearance to service regulator vent outlet [*72" (182.9 cm)
minimum]
J = clearance to non-mechanical air supply inlet to building
or the combustion air inlet to any other fireplace
[6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US
if between 10,000 and 50,000, 12" (30 cm) in Canada
if between 10,000 and 100,000; 12" (30 cm) in US if
greater than 50,000, 36" (91 cm) in Canada if greater
than 100,000]
K = clearance to a mechanical air supply inlet [*In Canada,
6 ft. (1.83m) minimum; In US 3 ft. (91 cm) above if within
10 ft. (3 m) horizontally]
L = † clearance above paved side-walk or a paved driveway
located on public property [*84" (213.3 cm) minimum]
M = clearance under veranda, porch, deck
[*12" (30.5 cm) minimum ‡]
N = clearance above a roof shall extend a minimum of
24" (61 cm) above the highest point when it passes
through the roof surface and any other obstruction within
a horizontal distance of 18" (45.7 cm)
C = Maximum depth of 48" (121.9 cm)
for recessed location
D = Minimum width for back wall of
recessed location Combustible - 38" (965 mm)
Noncombustible - 24" (61 cm)
E = Clearance from corner in
recessed location Combustible - 6" (15.2 cm)
Noncombustible - 2" (5.1 cm)
Figure 7 - Minimum Clearances for Termination Cap
125077-01B7
www.fmiproducts.com
REQUIREMENTS FOR THE COMMONWEALTH OF
MASSACHUSETTS
For all side wall horizontally vented gas fueled
equipment installed in every dwelling, building or
structure used in whole or in part for residential
purposes, including those owned or operated by
the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet
above finished grade in the area of the venting,
including but not limited to decks and porches,
the following requirements shall be satisfied:
INSTALLATION OF CARBON
MONOXIDE DETECTORS
At the time of installation of the side wall horizontal vented gas fueled equipment, the installing
plumber or gasfitter shall observe that a hard
wired carbon monoxide detector with an alarm
and battery backup is installed on the floor level
where the gas equipment is to be installed. In
addition, the installing plumber or gasfitter shall
observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed
on each additional level of the dwelling, building or
structure served by the side wall horizontal vented
gas fueled equipment. It shall be the responsibility
of the property owner to secure the services of
qualified licensed professionals for the installation
of hard wired carbon monoxide detectors.
In the event that the side wall horizontally
vented gas fueled equipment is installed
in a crawl space or an attic, the hard wired
carbon monoxide detector with alarm and
battery back-up may be installed on the next
adjacent floor level.
In the event that the requirements of this
subdivision can not be met at the time of
completion of installation, the owner shall
have a period of thirty (30) days to comply with
the above requirements; provided, however,
that during said thirty (30) day period, a battery
operated carbon monoxide detector with an
alarm shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required
in accordance with the above provisions shall
comply with NFPA 720 and be ANSI/UL 2034
listed and IAS certified.
SIGNAGE
A metal or plastic identification plate shall be
permanently mounted to the exterior of the
building at a minimum height of eight (8) feet
above grade directly in line with the exhaust
vent terminal for the horizontally vented gas
fueled heating appliance or equipment. The
sign shall read, in print size no less than 1/2" in
size, "GAS VENT DIRECTL Y BELOW . KEEP
CLEAR OF ALL OBSTRUCTIONS".
www.fmiproducts.com
INSPECTION
The state or local gas inspector of the side
wall horizontally vented gas fueled equipment
shall not approve the installation unless, upon
inspection, the inspector observes carbon
monoxide detectors and signage installed in
accordance with the provisions of 248 CMR
5.08(2)(a) 1 through 4.
EXEMPTIONS: The following equipment is ex-
empt from 248 CMR 5.08(2)(a) 1 through 4:
• The equipment listed in Chapter 10 entitled
"Equipment Not Required To Be Vented"
in the most current edition of NFPA 54 as
adopted by the Board; and
• Product Approved side wall horizontally
vented gas fueled equipment installed in a
room or structure separate from the dwelling, building or structure used in whole or
in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved
side wall horizontally vented gas equipment
provides a venting system design or venting
system components with the equipment, the
instructions provided by the manufacturer for
installation of the equipment and the venting
system shall include:
• Detailed instructions for the installation of
the venting system design or the venting
system components; and
• A complete parts list for the venting system
design or venting system.
Gas Equipment Venting System Not
Provided
When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for
venting the flue gases, but identifies "special
venting systems", the following requirements
shall be satisfied by the manufacturer:
•
The referenced "special venting system" instructions shall be included with the appliance
or equipment installation instructions; and
• The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list
and detailed installation instructions.
A copy of all installation instructions for all
Product Approved side wall horizontally
vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions
shall remain with the appliance or equipment
at the completion of the installation.
125077-01B8
VENTING INSTALLATION
NOTICE: Read these instructions completely before attempting installation.
These models are tested and approved for
use with FMI PRODUCTS, LLC (direct vent)
pipe components and terminations.
The venting system must terminate on the
outside of the structure and can not be attached to a chimney or flue system serving a
separate solid fuel or gas burning appliance.
A direct vent appliance must have its own
venting system. DO NOT common vent this
appliance.
These models are approved to be vented
either horizontally through an outside wall or
vertically through a roof or chase enclosure
using the following guidelines:
• When venting system terminates horizontally on an outside wall, you may install
a standoff if the termination cap is to be
installed directly on a combustible finish
such as vinyl, wood, stucco, etc.
• Never run the vent downward as this may
cause excessive temperatures which could
cause a fire.
• Vent pipe air space clearances to combustibles are 1" on all sides except on the
horizontal sections, which requires 2" clearance from the top of the pipe. Where the
termination cap penetrates a combustible
wall, 1" air space clearance is required.
• Have fireplace and selected vent compo-
nents on hand to help determine the exact
measurements when elbowing or offsetting.
Always use wall firestops when penetrating
walls and firestops when penetrating ceil-
ings or attic spaces.
• For installation of fireplace at elevations of
4000 feet or greater, pay special attention
to venting requirement recommendations.
WARNING: Read all instructions completely and thoroughly
before attempting installation.
Failure to do so could result in
serious injury , property damage
or loss of life.
NOTICE: Do not seal termination
cap to vent pipe. Cap must be
removable for vent inspection
and maintenance.
INSTALLATION PRECAUTIONS
• Wear gloves and safety glasses for
protection
• Use extreme caution when using ladders
or when on roof tops
• Be aware of electrical wiring locations in
walls and ceilings
The following actions will void the warranty
on your venting system:
• Installation of any damaged venting
component
• Unauthorized modification of the venting system (Do not cut or alter vent components)
• Installation of any component part not
manufactured or approved by FMI
PRODUCTS, LLC
• Installation other than as instructed by
these instructions
WARNING: This gas fireplace
and vent assembly must be
vented directly to the outside.
The venting system must NEVER
be attached to a chimney serving a separate solid fuel burning
appliance. Each direct vent gas
appliance must use a separate
vent system. Do not use common vent systems.
WARNING: Vent pipe air
space clearances to combustibles are 1" on all sides except
on the horizontal sections,
which require 2" clearances
from the top of the pipe. Where
the termination cap penetrates
a combustible wall, 1" air space
clearance is required.
NOTICE: Failure to follow these instructions will void the warranty .
125077-01B9
www.fmiproducts.com
INSTALLATION PLANNING
(Framing
Detail)
11
1
/2"
11
1
/2" Inside Framing
11
1
/2"
8 1/2"
Vent Opening
Combustible Wall
Vent Opening
Noncombustible Wall
There are two basic types of direct vent
installation:
• Horizontal Termination
• Vertical Termination
Outside air flex installation is required for
both horizontal and vertical installation (see
page 13).
Horizontal Termination Installation
IMPORTANT: Horizontal square terminations
require only inner portion of wall firestop. Horizontal installations using round termination
require exterior portion of wall firestop.
1. Set fireplace in its desired location and de-
termine the route your horizontal venting
will take. Do not secure fireplace until all
venting has been installed. Some installations require sliding fireplace in and out
of position to make final venting connections. Figures 14 and 15 on page 12 show
different configurations for venting with
horizontal termination that will help you
decide which application best suits your
installation. Check to see if wall studs or
roof rafters are in the path of your desired
venting route. If they are, you may want
to adjust location of fireplace.
2. Direct vent pipe sections and components
are designed with special twist-lock connections.
Twist-Lock Procedure: Female ends of
pipes have locking lugs (indentations).
These lugs will slide straight into matching slots on male ends of adjacent pipes.
Push pipe sections together and twist
one section clockwise approximately onequarter turn until sections are fully locked
(see Figure 8).
Note: Horizontal runs of vent must be sup-
ported every three feet. Use wall straps
for this purpose.
3. Assemble desired combination of pipe
and elbows to fireplace flue collar . If there
are long portions of venting run, pre-assembled pipe sections may be installed
as subassemblies for convenience.
4. Carefully determine location where vent
pipe assembly will penetrate outside wall.
VENTING INSTALLATION
Continued
Center of hole should line up with center
line of horizontal vent pipe. Mark wall for
an 11 1/2" x 11 1/2" square hole. Cut and
frame square hole in exterior wall where
vent will be terminated. If wall being penetrated is constructed of noncombustible
material, such as masonry block or concrete, a 8
acceptable (see Figure 9).
Figure 8 - Vent Pipe Connections
Figure 9 - Vent Opening Requirements
www.fmiproducts.com
1
/2" hole with zero clearance is
Female
Locking Lugs
Male
Slots
Center
of Hole
125077-01B10
VENTING INSTALLATION
Continued
WARNING: Do not recess
vent termination into any wall.
This will cause a fire hazard.
5. Noncombustible Exterior Wall: Position
horizontal vent cap in center of the 8
round hole and attach to exterior wall
with four wood screws provided. Before
attaching vent cap to exterior wall, run a
bead of non-hardening mastic (pliable
sealant) around outside edges to make a
seal between it and outside wall.
Note: Four wood screws provided should
be replaced with appropriate fasteners for
stucco, brick, concrete or other types of
sidings (see Figure 10).
Combustible Exterior Wall: For vinyl
siding, stucco or wood exteriors, a siding
standoff may be installed between vent
cap and exterior wall. Siding standoff
prevents excessive heat from damaging
siding materials. Siding material must be
cut to accommodate standoff. Bolt vent
cap to standoff. Apply non-hardening
mastic around outside edge of standoff.
Position standoff/cap assembly in the
center of 11
1
/2" square hole and attach to
exterior wall with provided wood screws
(see Figure 11). Siding standoff must sit
flush against exterior fascia material.
6. Connecting Vent Cap with Horizontal Vent Pipe: Slide wall firestop over vent
pipe before connecting horizontal run to
vent cap (see Figure 12).
Apply
Mastic to All
Four Sides
Vent Cap
Wood
Screw
1
/2"
Carefully move fireplace, with vent as-
sembly attached, toward wall and insert
vent pipe into horizontal termination. Pipe
overlap should be a minimum of 1
1
/4" (see
Figure 13, page 12).
Slide wall firestop against interior wall
surface and attach with screws provided.
See Figure 13, page 12, for horizontal
termination details.
Place fireplace into position and shim with
noncombustible material if needed. Nail or
screw side flanges to framing to secure
unit in place. IMPORT ANT: Make sure fire-
place is level before securing. If fireplace
is not level it will not work properly.
Cut Siding Away to
Fit Standoff
Standoff
Wood
Screw
Vent
Cap
Apply Mastic
to All Four Sides
Screws
Figure 11 - Installing Siding Standoff
(Combustible Exterior Wall)
Interior Wall
Surface
Wall
Firestop
Vent Cap
(Horizontal
Termination)
Figure 10 - Installing Horizontal Vent Cap
(Noncombustible Exterior)
Screw
Figure 12 - Connecting Vent Cap with
Horizontal
Vent Pipe
Horizontal Vent Pipe
125077-01B11
www.fmiproducts.com