Desco TB-5022 User Manual

Statguard® Floor Neutralizer Application Instructions
TECHNICAL BULLETIN
Figure 1. Statguard
®
Floor Neutralizer:
Item No. 46022, 2.5 gallon bag-in-box
Description
Statguard® Floor Neutralizer is designed for use with the Statguard® Flooring family of floor care products. Floor neutralizer helps to ensure maximum performance of Statguard® Floor Finish. Some high pH strippers will leave a residue behind even after several rinses. A high pH can affect the floor finish curing time as well as the physical properties of the finish. Neutralizing the floor after the stripping process ensures that the proper pH levels are established prior to the application of new floor finish.
To test for high pH residue, test the rinse water of the floor using either a pH measurement instrument or a piece of pH indicating litmus paper. A safe pH level will be between 7.0 (neutral) and 8 (mildly alkaline). Two sources for litmus paper are Micro Essential Laboratory, Brooklyn, NY 11210 and Fisher Scientific, Pittsburgh, PA 15219.
1. Use 8-10 ounces of Statguard® Floor Neutralizer, with a gallon of clean water. When mixing solution put water in a clean bucket first then add the neutralizer.
2. Using a clean string mop to apply the diluted neutralizer, uniformly distribute the solution. Wring out excess fluid and do not use excessive neutralizer.
3. Test the treated area with a piece of litmus paper. the floor should have a pH reading of about 7 to 8. Allow the solution to dry thoroughly before applying floor finish.
Coverage is 20,000 to 25,000 square feet per gallon of concentrate.
Physical Properties
Specific Gravity - 1.01 Weight/Gallon - 8.4 pounds pH - 3 - 4 Color - Light blue transparent Solubility in Water - 100%
Statguard® Floor Neutralizer does not have a set life span. The chemicals are not known to degrade over time when stored at the proper temperature conditions as stated in the Material Safety Data Sheet. We also recommend that the product be stored in its original container and be sealed when not in use.
Limited Warranty
Statguard® Flooring expressly warrants that for a period of one (1) year from the date of purchase, Statguard® Floor Neutralizer will be free of defects in material (parts). Within the warranty period, the material will be tested, repaired or replaced at Statguard® Flooring option, free of charge. Call our Customer
Service Department at (Marlboro, MA) for a Return Material Authorization (RMA) and proper shipping instructions and address. You should include a copy of your original packing slip, invoice, or other proof of purchase date. Any material under warranty should be shipped prepaid to the Statguard® Flooring factory. Warranty replacements will take approximately two weeks.
Warranty Exclusions
THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express warranty will not apply to defects or damage due to accidents, neglect, misuse, alterations, operator error, or failure to properly maintain, clean or repair products.
Limit of Liability
In no event will Statguard® Flooring or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith.
(508) 460-9860
Materials Needed:
• Mops
• Buckets
• Statguard
®
Floor Neutralizer
• Clean Water
After following the recommended stripping procedure, use diluted neutralizer to balance the pH value on the stripped floor.
TB-5022 January 2010 Page 1 of 4
432 NORTHBORO ROAD CENTRAL
MARLBORO, MA 01752
PHONE (508) 460-9860
FAX (508) 480-0257
StatguardFlooring.com
© 2010 DESCO INDUSTRIES INC.
Employee Owned
Material Safety Data Sheet
May be used to comply with ANSI Z400.1-2004, 29 CFR
1910.1200, European 2001/58/EC, REACH 1907/2006/ EC, and GHS. Standard must be consulted for specific requirements.
HMIS RATING: Health 1, Flammability 0, Physical Hazard 0, Personal Protection B
SECTION 1 — CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
NFPA Designation 704
Degree of Hazard 4 = Extreme 1 = Slight 3 = High 0 = Insignificant 2 = Moderate
Health
(Blue)
Special Hazard
Flammability
(Red)
0
1
0
Reactivity
0
(Yellow)
Product Name/Identity: Chemical Name: Manufacturer: Desco Industries, Inc Address: One Colgate Way
Canton, MA 02021
Telephone: 781-821-8370 Emergency Number: 781-821-8370 Date Prepared: 2010-01-04
SECTION 2 — HAZARDS IDENTIFICATION
Routes of Entry Eyes: Slight irritation Skin: Slight irritation Ingestion: None known Inhalation: Slight irritation
SECTION 3 — COMPOSITION/INFORMATION ON INGREDIENTS
Hazardous Ingredients: CAS No. Weight (%)
Acetic Acid 64-19-7 1-5% *There are no items listed and subjected to the reporting requirements of the SARA Title III Section 313 Inventory of the
Emergency Planning and Community Right-To-Know Act of 1986 and of 40 CFR372.
SECTION 4 — FIRST AID MEASURES
Signs & Symptoms of Exposure: Acute: Irritation of nasal passages, throat, lung, eye, and skin. (Acute and Chronic) Chronic: Redness of skin. May adversely affect existing respiratory problems.
Statguard® Floor Neutralizer
Emergency and First Aid Procedures: Eye Contact: Flush eyes for 15 minutes with water. Skin Contact: Wash with soap and water. Ingestion: Drink several glasses of water, induce vomiting. Contact a physician. Inhalation: Move to fresh air. Conditions Aggravated by Exposure: Overexposure may aggravate asthma.
SECTION 5 — FIREFIGHTING MEASURES
Proper Extinguishing Media: Non-Flammable Unsuitable Extinguishing Methods: N/A Protective Equipment & Precautions: Wearing of appropriate protective equipment and clothing Flash Point (Method Used): N/A Flammable Limits: N/A Special Fire Fighting Procedures: None required. Unusual Fire and Explosion Hazards: None known.
SECTION 6 — ACCIDENTAL RELEASE MEASURES
Personal Precautions: N/A Environmental Precautions: N/A Waste Disposal Method: According to local, state, and federal regulations. If Material is Released/Spilled: Keep spectators away. Dike and contain spill with inert material (e.g. sand, earth). Keep spills and cleaning runoffs out of municipal sewers and open bodies of water.
SECTION 7 — HANDLING AND STORAGE
Handling: Keep container closed, keep out of reach of children. Storage: Keep from freezing.
Statguard Flooring 432 NORTHBORO RD CENTRAL, MARLBORO, MA 01752 • PHONE (508) 460-9860 • FAX (508) 480-0257 • www.statguardflooring.com
TB-5022 Page 2 of 4
© 2010 DESCO INDUSTRIES INC.
Employee Owned
SECTION 8 — EXPOSURE CONTROL / PERSONAL PROTECTION
Hazardous Ingredients: CAS No. OSHA PEL
Acetic Acid 64-19-7 10 ppm Control Parameters: TLV-valve 400 ppm maximum for Isopropanol
Measures for Technical Control: Preferences of technical measure to prevent or control contact with the product. Isolating process and personnel, mechanical ventilation (dilution and local exhaust) and the regulation of process conditions. In case of non-prevention or non-control, a proper protective wearing should be used. Respiratory Protection (Specify Type): N/A Hand Protection: Impervious/Neoprene Gloves Eye Protection: Chemical splash goggles as defined in ANSI Z-87.1 or a similar standard. Other Protective Clothing or Equipment: Eyewash station. Ventilation: Local Exhaust: Mechanical at point of contamination release. Work/Hygienic Practices: Wash hands before eating, smoking, or using washroom facilities.
SECTION 9 — PHYSICAL AND CHEMICAL PROPERTIES
Form: Liquid Colour: Faint Blue Odour: N/A Boiling Point: >200°F Melting Point: N/A Specific Gravity (H2O = 1): 1.01 Solubility in Water: Complete pH: N/A Flash Point: N/A Flammability Limits: N/A Vapor Pressure (mm Hg) at 25°C: 23 Vapor Density (air=1): 1.0 Density at 20°C: N/A Weight per gallon: 8.4 lb./gal Flammability: Classification according to EC-regulations “non-flammable” Ignition Temperature: N/A Evaporation Rate: >.3
SECTION 10 — STABILITY AND REACTIVITY
Hazardous Polymerization: Will not occur Hazardous Decomposition/Byproducts: None known. Incompatibility (Materials to Avoid): Avoid alkaline compounds. Stability/Reactivity: Stable product at normal conditions. Conditions to Avoid: N/A
SECTION 11 — TOXICOLOGICAL INFORMATION
Acute toxicity: Special Effects: Carcinogenicity: NTP: None IARC Monographs: None OSHA Regulated: None
SECTION 12 — ECOLOGICAL INFORMATION
No environmental hazards have been reported or known. Mobility: N/A
Degradability: N/A Bioaccumulation: N/A Ecotoxicity: N/A Reference to BimSchV: N/A Hazard Classification: N/A
SECTION 13 — DISPOSAL CONSIDERATIONS
Product: According to local, state, and federal regulations. Hazardous Waste Number: Nonregulated
Statguard Flooring 432 NORTHBORO RD CENTRAL, MARLBORO, MA 01752 • PHONE (508) 460-9860 • FAX (508) 480-0257 • www.statguardflooring.com
TB-5022 Page 3 of 4
© 2010 DESCO INDUSTRIES INC.
Employee Owned
SECTION 14 — TRANSPORT INFORMATION
This product is not classified for transport under ADR/IMDG regulations
SECTION 15 — REGULATORY INFORMATION
Physical/Chemical Indication: Non-flammable Risk-Phrase: R11): Highly flammable. (R36/38): irritates eyes and skin. (R67): Vapors may cause drowsiness and dizziness. Safety-Phrase: (S2): keep away from children, (S7): keep containers well closed, (S24/25): avoid contact with skin and eyes, (S62): if swallowed, do not induce vomiting; seek medical advice immediately and show this container or label. EU Classification: (67/548/EEC-88/379/EEC): EINECS Status: All components are included in the EINECS inventories. REACH:
SECTION 16 — OTHER INFORMATION
HMIS RATING: Health 1, Flammability 0, Physical Hazard 0, Personal Protection B NFPA RATING: Special Hazard 0, Health 1, Flammability 0, Reactivity 0
Disclaimer The information given in this publication has been worked up to the best of the knowledge of Desco Industries Inc, as well as taking into consideration the applicable laws and regulations. We cannot anticipate all conditions under which this information and our products or the products of the manufacturers in combination with our products may be used. We accept no responsibility for the results obtained by the application information or the safety and suitability of our product or product combination with other products. Users are advised to make their own tests to determine the safety and suitability of each such product or product combination for their own purposes. Unless otherwise agreed in writing, we sell the products without warranty, and buyers end users assume responsibility and liability for loss or damage arising from the handling and use of our products, whether used alone or in combination with other products.
N/A = Not Applicable; NE = None Established
Statguard Flooring 432 NORTHBORO RD CENTRAL, MARLBORO, MA 01752 • PHONE (508) 460-9860 • FAX (508) 480-0257 • www.statguardflooring.com
TB-5022 Page 4 of 4
© 2010 DESCO INDUSTRIES INC.
Employee Owned