The AC Outlet Analyzer and Wrist Strap Tester is available in the following models:
Item Voltage Plug
98130 120V US 98131 220V UK / Asia
Instructions
Just plug AC Outlet Analyzer into an outlet to see if green pass LED is illuminated, verifying orientation. For wrist strap testing, plug wrist strap while worn into wrist strap test jack.
Figure 1. Desco 98130 AC Outlet Analyzer and Wrist Strap Tester
By touching the Test Button on the tester, a person can quickly and easily ensure that their wrist strap grounding system contains adequate current limiting resistance and that there is continuity from one’s skin to ground. The tester detects poorly fitting, worn out, corroded or dirty wrist straps. It can also be used to check the integrity of the conductive path from sleeve-to-sleeve of ESD protective garments.
“Typical test programs recommend that wrist straps that are used daily should be tested daily.” (Handbook ESD TR20.20 section 5.3.2.4.4)
Made in America
Figure 2. Desco 98131 AC Outlet Analyzer and Wrist Strap Tester
Description
When the AC Outlet Analyzer and Wrist Strap Tester is plugged into an AC outlet, the green LED lights if the outlet’s wiring is correct and the path to earth ground via the equipment grounding conductor (the green wire) is intact. The red LED lights if either condition is not met.
Use the AC Outlet Analyzer and Wrist Strap Tester to fulfill the S6.1 Section 6.3.1 requirement. “The hot, neutral, and equipment grounding conductor shall be verified to be in the proper wiring orientation in accordance with the National Electric Code (ANSIINFPA-70).” (Grounding ANSI ESD S6.1 section 6.3.1 Equipment Grounding Conductor)
Calibration
The AC Outlet Analyzer and Wrist Strap Tester is calibrated to NIST traceable standards. Calibration may be performed to insure that the tester is operating within limits. We recommend annual calibration of our testers.
Neutral
Load / Hot
Ground
Outlet LEDs
Wrist Strap Test LED
Test Plate
Wrist Strap Test Jack
FRONT VIEW
Figure 3. 98130 120V AC Outlet Analyzer and Wrist Strap Tester features and components
BACK VIEW
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: Desco.com
TB-2099 Page 1 of 3 June 2010
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
© 2010 DESCO INDUSTRIES, INC.
Employee Owned
Ground
Load / Hot
Outlet LEDs
Wrist Strap Test LED
Neutral
Wrist Strap Test Jack
Test Plate
FRONT VIEW
Figure 3.
98131
220V AC Outlet Analyzer and Wrist
BACK VIEW
Strap Tester features and components
TESTING THE WRIST STRAP TESTER PROCEDURE FOR ITEM 98130
A. LOW FAIL - Connect a 450 kilohm resistor @ 5%
tolerance between the Wrist Strap Test Jack and the Test Plate. The Wrist Strap Test LED will momentarily illuminate then turn off. This test confirms the LOW FAIL point.
B. LOW PASS - Connect a 550 kilohm resistor @ 5%
tolerance between the Wrist Strap Test Jack and the Test Plate. The Wrist Strap Test LED will remain illuminated until the resistor is removed from the Test Plate. This test confirms the LOW PASS point.
C. HIGH PASS - Connect a 45 megohm resistor @ 5%
tolerance between the Wrist Strap Test Jack and the Test Plate. The Wrist Strap Test LED will remain illuminated unitl the resistor is removed from the Test Plate. This test confirms the HIGH PASS point.
D. HIGH FAIL - Connect a 60 megohm resistor @ 5%
tolerance between the Wrist Strap Test Jack and the Test Plate. The Wrist Strap Test LED should not illuminate. This test confirms the HIGH FAIL point.
PROCEDURE FOR ITEM 98131 A. LOW FAIL - Connect a 675 kilohm resistor @ 5%
tolerance between the Wrist Strap Test Jack and the Test Plate. The Wrist Strap Test LED will momentarily illuminate then turn off. This test confirms the LOW FAIL point.
B. LOW PASS - Connect a 825 kilohm resistor @ 5%
tolerance between the Wrist Strap Test Jack and the Test Plate. The Wrist Strap Test LED will remain illuminated until the resistor is removed from the Test Plate. This test confirms the LOW PASS point.
C. HIGH PASS - Connect a 32 megohm resistor @ 5%
tolerance between the Wrist Strap Test Jack and the Test Plate. The Wrist Strap Test LED will remain illuminated unitl the resistor is removed from the Test Plate. This test confirms the HIGH PASS point.
D. HIGH FAIL - Connect a 40 megohm resistor @ 5%
tolerance between the Wrist Strap Test Jack and the Test Plate. The Wrist Strap Test LED should not illuminate. This test confirms the HIGH FAIL point.
TESTING THE AC OUTLET ANALYZER (98130 ONLY)
NOTE: The following procedure should only be done by someone familiar with voltage hazards. This procedure does not apply to item 98131 because the United Kingdom does not reference GROUND to NEUTRAL as the United States does.
Isolate the ground plug from the AC Outlet Analyzer and Wrist Strap Tester by inserting the tester into a “3 to 2” plug adapter.
A. PASS OUTLET - Connect a 5 kilohm resistor @ 5%
tolerance across the Neutral Plug and Ground Plug. The Outlet PASS LED should remain illuminated until the resistor is removed. This test confirms the PASS point for the neutral-to-ground resistance.
B. FAIL OUTLET - Connect a 12.5 kilohm resistor @ 5%
tolerance across the Neutral Plug and Ground Plug. The Outlet FAIL LED should remain illuminated until the resistor is removed. This test confirms the FAIL point for the neutral-to-ground resistance.