Desco 46100 Installation Manual

Features
• Tests ESD shoes (Ref: ANSI-Z41 Standard)
• Tests foot grounders
• Fast response - detects intermittent failures in floor system
• 30 VDC test voltage
• Verifies electrical outlets polarity and ground integrity
• Audible and visual indication
The Model 46100 includes a number of innovations:
Outlet Wiring Verification: When
plugged into an AC outlet the yellow lamp lights if the polarity is correct and the path-to-ground via equipment ground (green or green and yellow wire) is intact. If either condition isn't met, the alarm sounds continuously.
Floor Grounding verification:
With the unit plugged in and the flooring-to-ground resistance of 1 megohm (nominal)- the blue LED will remain on.
30 VDC Test Voltage: This is
sufficient to overcome the inaccuracies of 9 volt battery­powered wrist strap testers and high enough to comply with the ANSI­Z41 standard for Static Dissipative Shoes.
Transient and Noise Immunity:
Circuitry is impedance protected from line conducted voltage and current transients and surges.
Installation
• Mount the System Ground Monitor
at a height convenient for testing and observing results.
• Run AC power cord to a grounded
outlet. It is recommended that the outlet be checked first by a qualified electrician for proper wiring.
• Route supplied “Floor System” cord
down wall and embed 8-10" of the braided section in the conductive adhesive under the floor tile.
TB-5013 5/07 Page 1 of 2
Figure 1. Statguard Flooring System Ground Monitor, Item No. 46100
Description
The Statguard Flooring 46100 System Ground Monitor is a versatile, low-cost test instrument which confirms the resistance and integrity of the path-to­ground from the operator to ground via the Flooring - Footwear System. This product can be used as one of the tools to fulfill the ANSI ESD S20.20 paragraph 6.1.3.2 "Compliance Verification Plan. Verification should include routine checks of the Technical Requirements of the Plan." By touching the test button on the System Ground Monitor, a person can quickly and easily ensure that his/her foot grounding system contains recommended current limiting resistance and that there is continuity from skin to ground. In addition, the Monitor is designed to continuously check the integrity of the ground connection from the floor to electrical ground.
• This completes the installation. The System Ground Monitor is now ready to use.
General Instructions
In the following test configurations, the 46100 tests foot grounders or ESD shoes while they are worn.
TESTING ESD FOOTWEAR WITH MODEL 46100
ESD shoes or foot grounders should be worn on both feet. Test each foot separately to ensure each resistance path . Per ESD Handbook TR 20.20 paragraph 5.3.3.3.4 Proper Usage "ESD protective footwear is designed to reduce body charge levels by supplying a conductive path from the body to the floor material. Heel and Toe grounders should be worn on both feet to insure effective use."
Figure 3. Testing foot grounding devices with the 46100
A. Stand on one foot with ESD footwear in contact with ESD floor area to be tested.
B. Touch the test button so that the unit activates. Hold down for 2-3 seconds.
TECHNICAL BULLETIN
System Ground Monitor Operation and Maintenance
© 2007 DESCO INDUSTRIES INC.
Employee Owned
Made in America
C. Lighting of the green "PASS" LED indicates that the resistance path from foot grounder, ESD floor, and person is within proper limits.
D. If either "Fail LO" or "Fail HI" LEDs light, the wearer should investigate the cause of the failure.
E. Repeat steps Athrough D standing on the other foot.
Specifications: Operating Voltage
100-240 VAC 50/60 Hz
Current Drain
<20mA
Test Voltage, Open Circuit
30 VDC
Floor Ground Resistance Limit
10 megohms or less pass 20 megohms or greater fail
Resistance Limits, Foot Strap
750 kilohms to 35 megohms, ±10%
Size
1 x 5 x 7" (2.54 x 12.7 x 17.78cm)
Weight
1 lb
Line Cord
5' long, 18-3 AWG
Calibration
The model 46100 is calibrated to NIST traceable standards. We recommend that calibration is performed annually to ensure that the Tester is operating within limits. Contact the factory for additional information on calibration.
TB-5013 Page 2 of 2
Limited Warranty
Statguard Flooring expressly warrants that for a period of one (1) year from the date of purchase, Statguard Flooring monitors will be free of defects in material (parts) and workmanship (labor). Within the warranty period, a unit will be tested, repaired or replaced at our option, free of charge. Call Customer Service at
(781) 821-5609
for a Return Material Authorization (RMA) shipping instructions and address. You should include a copy of your original packing slip, invoice, or other proof of purchase date. Any unit under warranty should be shipped prepaid to the Statguard Flooring factory. Warranty repairs will take approximately two weeks.
If your material is out of warranty, Statguard Flooring will quote repair charges necessary to bring your unit up to factory standards. Call Customer Service at
(781) 821-5609
for a Return Material
Authorization (RMA) shipping instructions and address. Ship your material prepaid.
Warranty Exclusions
THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express warranty will not apply to defects or damage due to accidents, neglect, misuse, alterations, operator error, or failure to properly maintain, clean or repair products.
Limit of Liability
In no event will Statguard Flooring or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith.
90 HUDSON ROAD
CANTON, MA 02021
PHONE (781) 821-5609
FAX (781) 575-0172
StatguardFlooring.com
© 2007 DESCO INDUSTRIES INC.
Employee Owned
NOTE: Per ANSI/ESD S20.20 Paragraph
6.2.2.2 Personnel Grounding Guidance, "ESD protective flooring, used with approved footwear, may be used as an alternative to the wrist strap system for standing operations." And Paragraph
6.2.2.2 Personnel Grounding Guidance "A log should be maintained which verifies that personnel have tested their personal grounding devices." Per ESD Handbook TR20.20 paragraph
5.2.3 "If the contact area between the bottom of the foot and the floor is not continuous, charge generation may occur especially when a person is walking. Heel straps must be worn on both feet to minimize the amount of time that the body of the person is isolated from ground while walking."
DRILL PATTERN
FOR
SYSTEM GROUND
MONITOR
ACTUAL SIZE
2.4"
4.1"
Loading...