Desco 19784 Installation Manual

TECHNICAL BULLETIN TB-3046
Analog Surface Resistance Test Kit Operation and Maintenance
Compliance Verication Plan
“A Compliance Verication Plan shall be established to ensure the Organization’s fulllment of the technical requirements of the ESD Control Program Plan. Process monitoring (measurements) shall be conducted in accordance with a Compliance Verication Plan that identies the technical requirements to be veried, the measurement limits and the frequency at which those verications shall occur. The Compliance Verication Plan shall document the test methods and equipment used for process monitoring and measurements. If the test methods used by the Organization differ from any of the standards referenced in the document, then there must be a tailoring statement that is documented as part of the ESD Control Program Plan. Compliance verication records shall be established and maintained to provide evidence of conformity to the technical requirements. The test equipment selected shall be capable of making the measurements dened in the Compliance
Figure 1. Desco 19784 Analog Surface Resistance Test Kit
The Desco Analog Surface Resistance Test Kit is a portable battery-powered instrument designed to measure resistance point-to-point (RTT) and surface to ground (RTG). The meter is equipped with an automatic test voltage selector. The test voltage will switch from 10V to 100V should the measured resistance exceed 10E5 ohms.
ESD protected area products should be tested: A. Prior to installation to qualify for listing in user’s ESD control plan. Approved ESD materials (see product qualication table at ANSI/ESD S20.20-2007 Table 3 EPA ESD control items)
B. During initial installation
C. For periodic checks of installed products as part of ANSI/ESD S20.20-2007 Compliance Verication testing per ESD TR53.
Verication Plan.” (ANSI/ESD S20.20-2007 section 7.3)
The Analog Surface Resistance Meter and its accessories are available as the following item numbers:
Item Description
19784 Analog Surface Resistance Test Kit
19786 Analog Surface Resistance Meter
19785 Shielded Test Leads
50003 Electrodes, 5 lbs.
Packaging
19784 Analog Surface Resistance Test Kit
1 Analog Surface Resistance Meter 1 9V Alkaline Battery 2 Shielded Test Leads 2 Five Pound Electrodes 1 Plastic Carrying Case 1 Certicate of Calibration
19786 Analog Surface Resistance Meter
1 Analog Surface Resistance Meter 1 9V Alkaline Battery 1 Certicate of Calibration
Made in America
(Test Leads and Electrodes Included)
TB-3046 Page 1 of 4
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: Desco.com
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
January 2011
© 2010 DESCO INDUSTRIES, INC.
Employee Owned
Features and Components
A
B
C
Figure 2. Analog Surface Resistance Meter features and components
D
E
4. Use one 5 pound electrode on the other test lead and place it at the center of the surface.
5. Set the Test Voltage Button to AUTO. Press and hold the the TEST button until the measurement is displayed (see Figure 3).
6. Perform additional measurements by placing the electrode on the most commonly used or worn areas.
CAUTION: If there is a current limiting resistor in the worksurface and the worksurface resistance is lower, the measurement will primarily be the resistance of the resistor. It is recommended to measure RTT particularly if the material color is black.
A. Analog Display: Displays surface resistance measurements from 10E3 - 10E13 ohms.
B. Resistance Property LEDs: Color-coded LEDs that provide quick-check resistance indicators.
C. Test Button: Hold this button down to operate the Analog Surface Resistance meter.
D. Low Battery LED: Illuminates when the battery power drops below 5.5V.
E. Test Voltage Button: Test voltage will automatically switch from 10V to 100V when set to AUTO. Test voltage will stay at 10V HOLD when set to 10V.
Operation
Compliance Verication Test Procedure Guideline
The ESD Association lists test procedures and troubleshooting tips in Compliance Verication ESD TR53.
NOTE: The test kit can be used to measure RTG and RTT of shelves, garments, oor and cart worksurfaces using test procedures similar to worksurfaces and foot grounders.
MEASURE WORKSURFACE RESISTANCE TO
GROUND (RTG)
1. Do not clean the surface.
2. Remove all ESD sensitive items from the surface and items that might interfere with the test.
3. Connect one lead banana plug to ground.
Figure 3. Using the test leads and one 5 pound electrode to measure RTG
MEASURE WORKSURFACE RESISTANCE POINT-TO­POINT ON THE SURFACE (RTT)
1. Do not clean the surface.
2. Remove all ESD sensitive items from the surface and items that might interfere with the test.
3. Use two 5 pound electrodes and place them 10" apart on the most frequently used area of the surface (2" from any edge, 3" from any groundable point).
4. If the most used area of the surface is not obvious, use two points near the center of the surface.
5. Set the Test Voltage Button to AUTO. Press and hold the TEST button until the measurement is displayed (see Figure 4).
TB-3046 Page 2 of 4
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: Desco.com
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
© 2010 DESCO INDUSTRIES, INC.