ELECTRIC FIREPLACE/INSERT
MODELS CGEF32A, CGEF32B, VEF32 and EV32L
SAFETY INFORMATION AND INSTALLATION MANUAL
Read these instructions completely before beginning
installation. Failure to follow them could cause a heater
malfunction resulting in serious injury and/or property
damage.
WARNING: All electric heaters have hot and arcing or
sparking parts inside. Do not use it in areas where gaso-
line, paint or ammable liquids are or are stored.
WARNING: This heater is tested and listed for use only
with the optional accessories listed in these instruc-
tions. Use of optional accessories not specically
tested for this heater could void the heater warranty
and/or result in a safety hazard.
This replace meets the construction and safety standards of H.U.D. for application in manufactured homes
when installed according to these instructions.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.desatech.com

TABLE OF CONTENTS
Safety Information ............................................... 2
Listing Approvals ................................................. 3
Product Dimension Specications ....................... 3
Product Identication ........................................... 3
Locating Fireplace ............................................... 4
Unpacking and Testing Fireplace ........................ 4
Installation ........................................................... 5
Finishing .............................................................. 7
SAFETY INFORMATION
Operating Instructions ......................................... 7
Cleaning and Maintenance .................................. 8
Technical Service............................................... 10
Wiring Diagram .................................................. 10
Replacement Parts ............................................ 10
Troubleshooting ..................................................11
Warranty Information ........................... Back Cover
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer
to this manual. For assistance or
additional information, consult
a qualied installer.
CAUTION: Do not expose the
heater to the elements (such as
rain, etc).
CAUTION: The replace insert unit is mounted on rubber
feet. The purpose is to ensure
adequate air circulation beneath
unit. DO NOT remove these feet.
Do not install directly on carpet,
rug, furniture or similar surfaces
which could hinder or block the
air ow.
Due to high temperatures, the
rebox should be located out of
trafc and away from furniture
and draperies.
Do not place clothing or other
ammable material on or near
rebox. Never place any objects
on the replace.
Carefully supervise young children when they are in the room
with replace.
Fireplace becomes very hot
when running. Keep children and
adults away from hot surfaces to
avoid burns or clothing ignition.
Fireplace will remain hot for a
time after shutdown. Allow surfaces to cool before touching.
When using electrical heaters, basic precautions
should always be followed to reduce the risk of
re, electric shock and injury to persons, including
the following:
1. Read all instructions before using this heater.
2. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes and curtains
at least 3 feet from front of heater and keep
them away from sides and rear.
3. Always unplug heater when not in use.
4. Do not operate any heater with a damaged cord
or plug or after heater malfunctions, has been
dropped or damaged in any way. Return heater
to authorized service facility for examination,
electrical or mechanical adjustment or repair.
5. Do not use outdoors.
6. This heater is not intended for use in bathrooms, laundry areas and similar indoor
locations. Never locate heater where it may
fall into a bathtub or other water container.
7. Do not run cord under carpeting. Do not cover
cord with throw rugs, runners or the like. Ar-
range cord away from trafc area and where
it will not be tripped over.
8. To disconnect heater, turn controls to "OFF"
before removing plug from outlet.
9. Do not insert or allow foreign objects to enter any
ventilation or exhaust opening as this may cause
an electric shock or re or damage the heater.
10. To prevent possible fire, do not block air
intakes in any manner.
11. A heater has hot and arcing or sparking parts
inside. Do not use it in areas where gasoline,
paint or ammable liquids are used or stored.
www.desatech.com
117205-01B2

SAFETY INFORMATION
Continued
12. Use this heater only as described in this
manual. Any other use not recommended
by the manufacturer may cause re, electric
shock or injury to persons.
13. Avoid the use of an extension cord because
the extension cord may overheat and cause
a risk of re. However, if you have to use an
extension cord, the cord should be No. 14
AWG minimum size and rated not less than
1875 WATTS.
14. Always use properly grounded fused and
polarized outlets.
15. Always use ground fault protection where
required by electrical codes.
16. Always disconnect power before performing
any cleaning, maintenance or relocation of
heater.
17. To prevent a possible re, do not burn wood
or other materials in this heater.
18 To prevent electric shock or re, always use
a certied electrician should new circuits or
outlets be required.
19. When transporting or storing heater, keep in
a dry place free from excessive vibration and
store as to avoid damage.
LISTING APPROVALS
This heater has been tested in accordance with the
CSA Standards for xed and location-dedicated
electric room heaters in the United States. All
components are UL or CSA safety certied.
If you need assistance during installation, please con-
tact your local dealer or the DESA Heating Products
Technical Services Department at 1-866-672-6040.
Model Voltage Watts
CGEF32B, VEF32,
EV32L
CGEF32A
Note: This heater must be electrically wired and
grounded in accordance with local codes or, in
the absence of local codes, with National Electric
Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C2.1 as appropriate.
117205-01B 3
120 1500
120/
240
1600/
3000
www.desatech.com
PRODUCT DIMENSION
SPECIFICATIONS
Figure 1 - Heater Dimensions
PRODUCT
IDENTIFICATION
Fuse
Top Screen
Screws
Back
Glass
ON/OFF
Power
Button
Figure 2 - Product Identication
Heat Vents
Temp. Control
Button and LED
Bottom Screen Screw
Flame Control
Button and LED
Bottom
Panel

LOCATING FIREPLACE
WARNING: Due to high tem-
peratures, this heater should
be located out of trafc. Keep
combustible materials such
as furniture, pillows, bedding,
papers, clothes and curtains at
least 3 feet (.9m) from the front
of the heater.
WARNING: Never locate this
heater where it may fall into a bathtub or other water container.
NOTICE: Minimum and maximum
clearances must be maintained at
all times. Illustrations throughout
these instructions reect typical
installations and are for design
purposes only. Actual installations may vary slightly due to
individual preferences.
WARNING : To p r e v ent
contact with sagging or loose
insulation, the heater must not
be installed against vapor barrier
or exposed insulation. Localized
overheating could occur and a
re could result.
CAUTION: Do not expose the
heater to the elements (such as
rain, etc.)
CAUTION: Wear gloves and
safety glasses for protection during installation and maintenance.
Figure 3 illustrates a variety of ways the heater may
be located in a room. The heater may be installed
directly on the oor, carpet or raised on a hearth.
Figure 3 - Heater Locations
UNPACKING AND
TESTING FIREPLACE
Carefully remove the unit from the box. Prior
to permanently installing the unit, test to make
sure the unit operates properly. To do this, plug
the unit's power supply cord into a conveniently
located 120-volt grounded outlet.
CAUTION; The unit's power
supply cord must be connected
to a properly grounded and protected 120-volt outlet. Always
use ground fault protection
where required by the electrical code.
WARNING: Do not operate
the unit if it is damaged or has
malfunctioned. If you suspect
the unit is damaged, return the
unit to an authorized service
facility for examination, electrical or mechanical adjustment
or repair.
www.desatech.com
117205-01B4