Desa Tech REM35LP, RLP35 Owner's Manual

G
I
D
E
S
I
N
A
E
S
T
D
C
E
R
T
I
I
F
I
E
A
M
C
R
A
S
O
C
I
A
O
N
NRTL
®
PROPANE
CONSTRUCTION
HEATER
OWNER’S MANUAL
Heater Size: 35,000 BTU/Hr
IMPORTANT Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
!
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUC­TIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
CONTENTS
WARNING ICON G 001
WARNING ICON G 001
SECTION PAGE
Safety Information.........................................................................2
Product Identification .................................................................... 4
Unpacking......................................................................................4
Theory of Operation ......................................................................5
Propane Supply..............................................................................5
Installation .....................................................................................6
Ventilation .....................................................................................7
Operation .......................................................................................7
Storage ........................................................................................... 9
Maintenance .................................................................................. 9
Troubleshooting.............................................................................10
Service Procedures ........................................................................ 11
Specifications.................................................................................14
Accessories .................................................................................... 14
Technical Service ..........................................................................15
Replacement Parts .........................................................................15
Illustrated Parts List.......................................................................16
Warranty and Repair Service.........................................................Back Cover
SAFETY
INFORMATION
WARNINGS
WARNING: FIRE, BURN, INHALATION, AND EXPLOSION
WARNING ICON G 001
HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOL­VENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
WARNING
NOT FOR HOME OR RECREATIONAL VEHICLE USE.
The heater is designed for use as a construction heater in accordance with ANSI Z83.7. Other standards govern the use of fuel gases and heating products for specific uses. Your local authority can advise you about these. The primary purpose of construction heaters is to provide temporary heating of buildings under construction, alteration or repair. Properly used, the heater provides safe economi­cal heating. Products of combustion are vented into the area being heated.
We cannot foresee every use which may be made of our heaters. Check with your local fire safety authority if you have questions about heater use.
Other standards govern the use of fuel gases and heat producing products for specific uses. Your local authorities can advise you about these.
Carbon Monoxide Poisoning: Some people are more affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu,
with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Check for proper ventilation and have heater serviced.
2
Safety Information continues on next page
099549
SAFETY
INFORMATION
Continued
2
099549
!
WARNINGS
Propane Gas: Propane gas is odorless. An odor-making agent is added to propane
gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas can fade. Propane gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
• Install and use heater with care. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the Standard for Storage and
Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and the Natural Gas Installation Code, CAN/CGA B149.2. This instructs on the safe storage and
handling of propane gases.
• Use only the electrical voltage and frequency specified on model plate.
• The electrical connections and grounding of the heater shall follow the Na­tional Electric Code, ANSI/NFPA 70.
• Electrical grounding instructions — This appliance is equipped with a three­prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
• Use only a three-prong, grounded extension cord.
• Use only the hose and factory preset regulator provided with the heater.
• Use only propane gas set up for vapor withdrawal.
• Provide adequate ventilation. Before using heater, provide at least a one-square­foot opening of fresh, outside air. This heater produces carbon monoxide, which is listed by the State of California as a reproductive toxin under Proposition 65.
• For indoor use only. Do not use heater outdoors.
• Do not use heater in occupied dwellings or in living or sleeping quarters.
• Do not use heater below ground level. Propane gas is heavier than air. If a leak occurs, propane gas will sink to the lowest possible level.
• Keep appliance area clear and free from combustible materials, gasoline, paint thinner, and other flammable vapors and liquids. Do not use heater in areas with high dust content.
• Minimum heater clearances from combustibles: Outlet: 6 Ft. Sides: 2 Ft. Top: 6 Ft. Rear: 2 Ft.
• Keep heater at least six feet from propane tank(s). Do not point heater at propane tank(s) within 20 feet.
• Keep propane tank(s) below 100° F.
• Check heater for damage before each use. Do not use a damaged heater.
• Check hose before each use of heater. If highly worn or cut, replace before using heater.
• Locate heater on stable and level surface if heater is hot or operating.
• Not intended for use on finished floors.
• Never block air inlet (rear) or air outlet (front) of heater.
• Keep heater away from strong drafts, water spray, rain, or dripping water.
• Do not leave heater unattended.
• Keep children and animals away from heater.
• Never move, handle, or service a hot, operating, or plugged-in heater. Severe burns may result. You must wait 20 minutes after turning heater off.
• To prevent injury, wear gloves when handling heater.
• Never attach duct work to front or rear of heater.
• Do not alter heater. Keep heater in its original state.
• Do not use heater if altered.
• Turn off propane supply and unplug heater when not in use.
• Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries.
Continued
3
PRODUCT
IDENTIFICATION
Hot Air Outlet (Front)
Shell
Handle
Motor
Fan Guard
Heater Base
UNPACKING
Piezo Ignitor Button
Automatic Control Valve Button
Hose /Regulator Assembly
Figure 1 - 35,000 BTU/Hr Model
Inlet Connector
Power Cord
1. Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to inlet connector and hose/regulator assembly) for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
4
099549
THEORY OF
OPERATION
Clean Heated Air Out (Front)
The Fuel System: The hose/regulator assembly attaches to the propane gas supply. This provides fuel to the heater.
The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The piezo ignitor lights the burner. The Automatic Control System: This system causes the heater to shut down
if the flame goes out.
Combustion Chamber
Fan
Motor
Cool Air In (Back)
PROPANE
SUPPLY
Hose/Regulator Assembly
Air For Combustion Air For Heating
Figure 2 - Cross Section Operational View
Propane gas and propane tank(s) are to be furnished by the user. Use this heater only with a propane vapor withdrawal supply system. See Chapter 5
of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA
58. Your local library or fire department will have this booklet. The amount of propane gas ready for use from propane tanks varies. Two factors
decide this amount:
1. The amount of propane gas in tank(s)
2. The temperature of tank(s) This heater is designed to operate with a minimum 20-pound propane tank. You
may need two or more tanks or one larger tank in colder weather. Use a 100-pound tank for longer operation or in very cold weather. Less gas is vaporized at lower temperatures. Your local propane gas dealer will help you select the proper supply system. The minimum surrounding air temperature rating for each heater is -20°F (-29°C).
099549
Average Temperature (°F) At Tank Location 40° 32° 20° 10° 0° -10° -20°
Number Of Tanks (100-pound) 1111 1 2 2
5
INSTALLATION
Review and understand the warnings in the Safety Informa­tion Section, pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater.
!
WARNING
Test all gas piping and connections for leaks after installa­tion or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
1. Provide propane supply system (see Propane Supply, page 5).
2. Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL fitting counterclockwise into threads on tank. Tighten firmly using 7/8" wrench. regulator is in a horizontal position (see Figure 3). This places the regulator vent in the proper position to protect it from the weather.
IMPORTANT:
Propane Supply Valve
Propane Tank
WARNING
!
Position regulator so that hose leaving the
Regulator
Hose
POL Fitting
Figure 3 - Regulator Position
3. Connect hose to inlet connector. Tighten firmly using a wrench.
IMPORTANT:
between hose/regulator assembly and propane tank. You must use the regula­tor supplied with heater.
6
Use extra hose or piping if needed. Install extra hose or piping
Inlet Connector
Figure 4 - Hose and Inlet Connector
Hose
099549
Loading...
+ 14 hidden pages