WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
This firebox may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer (i.e. Installation of this product is
permitted after the manufactured (mobile) home is sited).
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause
injury or property damage. Refer to this manual for correct
installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or
the gas supplier.
WARNING: For use only with
decorative type unvented room
heaters. Do not build a wood fire.
This firebox has been tested and
approved by I.A.S. under their
REQ. 2-97 for use with any ANS
Z21.11.2 approved gas logs.
Save this manual for future reference.
FIREPLACE MANUFACTURERS INC.
UNVENTED 32" FIREBOX
SAFETY
INFORMATION
WARNINGS
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate, or service this firebox. Improper use of this firebox can cause
serious injury or death from burns,
fire, explosion, electrical shock, or
carbon monoxide poisoning.
CAUTION: Carefully review
the instructions supplied with
the decorative type unvented
room heater for the minimum
fireplace size requirement. Do
not install the appliance in this
firebox, unless this firebox
meets the minimum dimensions
required for the installation.
WARNING: Any change to
this firebox or its controls can
be dangerous.
1.This firebox shall not be installed in a
bedroom or bathroom.
2.Never install the firebox
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than
42 inches from the front, top, or sides
of the firebox
• in high traffic areas
• in windy or drafty areas
3.Do not use this firebox as a wood-burning fireplace. Use only decorative
unvented room heaters (log sets).
4.Do not add extra logs or ornaments
such as pine cones, vermiculite, or rock
wool. Using these added items can
cause sooting.
5.Y ou must operate this fireplace with the
fireplace screen, hood, and brick liner
in place. Make sure these parts are in
place and screens are closed before running firebox.
6.Do not allow fans to blow directly into
the firebox. Avoid any drafts that alter
burner flame patterns. Ceiling fans can
create drafts that alter burner flame
patterns. Altered burner patterns can
cause sooting.
7.Do not use a blower insert, heat exchanger
insert or other accessory not approved for
use with this heater. Do not use blower
accessory with Models RUV 32 and
NLRUV32. Use only the provided hood
or GA6096 polished brass hood accessory
(see Accessory on page 11).
8.Vent-free gas log heaters installed in
these fireboxes require fresh air ventilation to run properly . See Air for Com-bustion and Ventilation, pages 4
through 6.
9.Do not run firebox
• where flammable liquids or vapors
are used or stored
• under dusty conditions
10. Do not use this firebox to cook food or
burn paper or other objects.
11. Never place any objects in the firebox
or on logs.
12. Firebox front and screen becomes very
hot when running firebox. Keep children and adults away from hot surfaces
to avoid burns or clothing ignition. Firebox will remain hot for a time after
shut-down. Allow surfaces to cool before touching.
13. Carefully supervise young children
when they are in the room with firebox.
14. Turn firebo x off and let cool before servicing. Only a qualified service person
should service and repair firebox.
15. Operating vent-free log sets in a firebox above elevations of 4,500 feet
could cause pilot outage.
16. Do not use the firebox if it has been
under water due to the shock hazard that
could result with the blower accessary
(if installed) in place.
LOCAL CODES
Install and use fireplace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel GasCode ANS Z223.1, also known as NFPA 54*.
Firebox must be electrically grounded in
accordance with the National Electrical Code,ANS/NFPA70 (latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
1.With utility knife, cut the carton all the
way around above the staples on the
bottom tray. Lift the car ton off the firebox. Remove packing.
is located in the packing on the right
hand side of the heater front. Lift the
heater off the bottom tray.
2.Check carton contents for the
following:
• Screen assembly (2)
• Screen support rod (2)
• Hood
• Hardware and parts bag containing
the following:
-Owner’s Operation and
Installation Manual
-2 - Black #10 x 3/8" Phillips
screws
-3 - Zinc #10 x 1/2" shouldered
hex screws
-2 - Black #10 x 5/8" shouldered
hex screws
If any items are missing, inform
dealer where you bought firebox.
3.Check all items for any shipping damage. If damaged, promptly inform
dealer where you bought firebox.
Note:
The hood
2
105509
PRODUCT
SPECIFICATIONS
Standoffs (Models RUV32
and NLRUV32 only)
35 1/16"
OWNER’S MANUAL
3
2
/4"
Built-in
Nailing
Flanges
Louvers
(Models UV32C and NLUV32C only)
Figure 1 - Firebox Front View
Standoffs
(Models RUV32 and NLRUV32 only)
3
/4"
2
33
1
1
/2"
6"
11
/16"
3
/16"
32
19
3
/8"
3
/4"
31
19
1
16
/4"
3
/4"
2
3
/8"
6
22 1/2"
11
16
/16"
1
/4"
Electrical
Access Hole
Electrical Access
Hole with Bushing
Figure 2 - Firebox Side View
105509
12 1/2"
3
9
/4"
5
4
/8"
Gas Line Access
5
31
/8"
34 3/8"
35 5/8"
Figure 3 - Firebox Top View
1
2
/2"
3
FIREPLACE MANUFACTURERS INC.
UNVENTED 32" FIREBOX
PRODUCT
FEATURES
OPERATION
This firebox is designed for use with approved ANS Z21.1.2 decorative type
unvented room heaters. (Physical size limitations apply. Refer to minimum firebox
requirements supplied with log heater.) It
requires no outside venting or chimney making installation easy and inexpensive. When
used without the blower (models UV32C
and NLUV32C only), the firebox requires
no electricity making it ideal for emergency
back-up heat.
BLOWER ACCESSORY
The UV32C and NLUV32C fireboxes will
accept the FA3700 accessory. The variable
blower allows you to select the fan speed
you desire. The blower circulates heated air
from the firebox into the room. Use of
blower is optional.
LOCATING
FIREBOX
PLANNING
Plan where you will install the firebox. This
will save time and money later when you
install the firebox. Before installation, consider the following:
1.Where the firebox will be located. Allow for wall and ceiling clearances (see
Installation Clearances, page 7).
2.Everything needed to complete installation.
3.These models CANNOT be installed in
a bedroom or bathroom.
4.Proper air for combustion and ventilation (see below).
AIR FOR
COMBUSTION AND
VENTILATION
WARNING: This firebox shall
not be installed in a confined space
or unusually tight construction
unless provisions are provided
for adequate combustion and ventilation air. Read the following instructions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased
insulation, and new construction methods
help reduce heat loss in homes. Home owners
weather strip and caulk around windows and
doors to keep the cold air out and the warm air
in. During heating months, home owners
want their homes as airtight as possible.
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireboxes, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide adequate fresh air for these appliances. This
will insure proper venting of vented fuelburning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National
Fuel Gas Code. NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 4 through 6 will
help you classify your space and provide
adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a continuous water vapor retarder with
a rating of one perm (6x10
per pa-sec-m2) or less with openings gasketed or sealed
b. weather stripping has been
added on openable windows
and doors
c. caulking or sealants are applied
to areas such as joints around
window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide
additional fresh air. See
Air From Outdoors,
If your home does not meet all of the
three criteria above, proceed to
mining Fresh-Air Flow For Firebox
Location
, page 5.
and
page 6.
-11
kg
and
Ventilation
Deter-
Confined Space and Unconfined
Space
The National Fuel Gas Code (ANS Z2123.1,
1992 Section 5.3) defines a confined space
as a space whose volume is less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space and an
unconfined space as a space whose volume
is not less than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the aggregate
input rating of all appliances installed in that
space. Rooms communicating directly with
the space in which the appliances are installed*, through openings not furnished
with doors, are considered a part of the
unconfined space.
This heater shall not be installed in a confined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.
* Adjoining rooms are communicating only
if there are doorless passageways or ventilation grills between them.
4
105509
OWNER’S MANUAL
AIR FOR
COMBUSTION
AND VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR FIREBOX LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install firebox plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height = _________ cu. ft. (volume of space)
Example
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total vol ume of
the space.
2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
__________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example:
3.Add the Btu/Hr of all fuel burning appliances in the space.
Gas water heater*_____________________ Btu/Hr
Gas furnace_____________________ Btu/Hr
Vented gas heater_____________________ Btu/Hr
Gas firebox logs_____________________ Btu/Hr
Other gas appliances*+_____________________ Btu/Hr
Total=_____________________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_____________________Btu/Hr (maximum the space can support)
_____________________Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space pr ovides an unconfined space, remov e door to adjoining
room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 6.
C. Install a lower Btu/Hr firebox, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
: Space size22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)
3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support)
Example:
Gas water heater40,000Btu/Hr
Vent-free firebox
with log heater+ 39,000Btu/Hr
Total= 79,000Btu/Hr
63,300 Btu/Hr (maximum the space can support)
79,000 Btu/Hr (actual amount of Btu/Hr used)
WARNING: If the area in which the firebox and gas log heater may be operated is smaller than that defined
as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and
ventilation air by one of the methods described in the
applicable local codes.
105509
National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3
Continued
5