Desa Tech GFP28MLP, GFP28TLP Owner's Manual

Page 1
UNVENTED (VENT-FREE)
PROPANE/LP GAS FIREPLACE
This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
OWNERS OPERATION AND INSTALLATION MANUAL
GFP28MLP
AND
GFP28TLP
®
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus­ing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in­structions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
Shown with optional cabinet mantel and hearth base.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional infor­mation consult a qualified in­staller, service agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxy­gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to
Combustion and Ventilation
tion in this manual.
Air for
sec-
Save this manual for future reference.
Page 2
CONTENTS
SECTION PAGE
Safety Information................................................................................... 2
Product Identification .............................................................................. 4
Local Codes ............................................................................................. 5
Unpacking................................................................................................ 5
Product Features ...................................................................................... 5
Air for Combustion and Ventilation........................................................ 6
Installing .................................................................................................. 9
Check Gas Type ............................................................................... 9
Assembling and Attaching Brass Trim ............................................ 10
Installation Clearances ..................................................................... 11
Conventional Fireplace Installation ................................................. 11
Built-In Fireplace Installation .......................................................... 13
Installing Gas Piping to Fireplace Location ..................................... 15
Connecting Fireplace to Gas Supply ................................................ 17
Checking Gas Connections .............................................................. 18
Installing Logs.................................................................................. 20
Operating Fireplace (Thermostat-controlled Model) .............................. 21
Operating Fireplace (Variable Manually controlled Model)................... 23
Inspecting Burners................................................................................... 26
Cleaning and Maintenance ...................................................................... 28
Troubleshooting....................................................................................... 28
Illustrated Parts Lists ............................................................................... 32-37
Service Hints ........................................................................................... 38
Specifications .......................................................................................... 38
Technical Service .................................................................................... 38
Wiring Diagram....................................................................................... 38
Replacement Parts ................................................................................... 39
Accessories .............................................................................................. 39
Warranty Information .............................................................................. Back Cover
SAFETY
INFORMATION
2
WARNINGS
WARNING ICON G 001
IMPORTANT: Read this owners manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explo­sion, electrical shock, and carbon monoxide poisoning.
DANGER
WARNING ICON G 001
Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re-
semble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Propane/LP Gas: Propane/LP gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.
Safety Information continues on next page
103091
Page 3
SAFETY
INFORMATION
Continued
103091
WARNINGS
WARNING: Any change to this fireplace or its controls can be dangerous.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building
• immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the fire department
4. This fireplace shall not be installed in a bedroom or bathroom.
5. Never install the fireplace
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace
• in high traffic areas
• in windy or drafty areas
6. Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.
7. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.
8. You must operate this fireplace with the fireplace screen in place. Make sure fire­place screen is in place before running fireplace.
9. This fireplace is designed to be smokeless. If logs ever appear to smoke, turn off fireplace and call a qualified service person. smoking could occur due to log curing and fireplace burning manufacturing residues.
10. Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.
11. Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.
12. This fireplace needs fresh air ventilation to run properly. This fireplace has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation, pages 6 through 8. If fireplace keeps shutting off, see Troubleshooting, pages 28 through 31.
13. Do not run fireplace
• where flammable liquids or vapors are used or stored
• under dusty conditions
14. Do not use this fireplace to cook food or burn paper or other objects.
15. Never place any objects in the fireplace or on logs.
16. Fireplace front and screen becomes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shut-down. Allow surfaces to cool before touching.
17. Carefully supervise young children when they are in the room with fireplace.
18. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.
19. Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).
20. Turn fireplace off and let cool before servicing. Only a qualified service person should service and repair fireplace.
21. Operating fireplace above elevations of 4,500 feet could cause pilot outage.
Continued
Note:
During initial operation, slight
3
Page 4
PRODUCT
IDENTIFICATION
Front Burner
Front Log (#1)
Rear Log (#2)
Left Front Branch (#4)
Base
Top Louvered
Hood
Rear Burner
Gas Regulator
Right Front Branch (#5)
Figure 1 - Log Base Assembly
Top Outer Casing
Firebox Support
Rear Access Door
Screen Assembly
Bottom Louver Assembly
4
Figure 2 - Fireplace
Side Access Door
103091
Page 5
LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
PRODUCT
FEATURES
1. Place the carton containing the fireplace unit on its back. Hold fireplace and pull the carton and pallet away. Remove trim kit from front of fireplace.
2. Locate two screws above top corners of the fireplace screen. Remove and discard these screws. Lift fireplace screen up and pull out to remove.
3. Remove protective packaging applied to logs, log base assembly, and fireplace.
4. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought fireplace.
Operation
This vent-free fireplace is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing embers. When used without the blower, the fireplace requires no electricity making it ideal for emergency back-up heat.
Safety Features
This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS system protecta against oxygen depletion and any interruption in the fuel supply. If either occurs, the ODS shuts off gas flow to the burner, turning the fireplace off. An internal regulator controls fluctuations in your gas pressure.
Piezo Ignition System
This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.
103091
Blower Assembly
The thermostatically-controlled fireplace has a blower assembly. The blower operates thermostatically or manually. The blower circulates heated air from the fireplace into the room. Use of blower is optional.
Thermostat Control Models (GFP28TLP)
These fireplaces have a thermostat sensing bulb and a control valve. The thermo­stat controls the heat output and flame height. This maintains a consistent room temperature. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher comfort settings allows fireplace to run longer, producing greater heat output. At lower comfort settings, the fireplace will run less. This results in increased heating comfort. This can also result in lower gas bills.
Variable Manual Control (GFP28MLP)
These fireplaces have a variable manual control valve which allows the user to choose the heat setting that best suits his needs. Any setting between low and high may be selected by simply turning the control knob.
5
Page 6
AIR FOR
COMBUSTION
AND
VENTILATION
WARNING
This heater shall not be installed in a confined space unless provi­sions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space. The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continu-
ous water vapor retarder with a rating of one perm or less with open-
ings gasketed or sealed b. weather stripping has been added on openable windows and doors c. caulking or sealants are applied to areas such as joints around window
and door frames, between sole plates and floors, between wall-ceiling
joints, between wall panels, at penetrations for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide addi­tional fresh air. See
If your home does not meet all of the three criteria above, continue reading.
Ventilation Air From Outdoors
and
, page 8
and
.
Unconfined Space
The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon- fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms.
Confined Space
The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines confined space as having an air volume of less than 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless
6
passageways or ventilation grills between the rooms.
103091
Page 7
AIR FOR
COMBUSTION
AND
VENTILATION
Continued
DETERMINING AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms
with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x width x height). Length x Width x Height = ___________________ cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
____________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr
the space can support)
Example:
3. Add the Btu/Hr of all fuel burning appliances in the space.
Example:
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_________________ Btu/Hr (maximum the space can support) _________________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework work sheet, adding the space of an adjoining room. If the extra space pro-
vides an unconfined space, remove door to adjoining room or add ventilation grills
between rooms. See Ventilation Air from Inside Building, page 8. B. Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 8. C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) =
3168 cu. ft. (volume of space)
3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support)
Vent-free fireplace ___________________ Btu/Hr Gas water heater* ___________________ Btu/Hr Gas furnace ___________________ Btu/Hr Vented gas heater ___________________ Btu/Hr Gas fireplace logs ___________________ Btu/Hr Other gas appliances* + ___________________ Btu/Hr Total = ___________________ Btu/Hr
Gas water heater 40,000 Btu/Hr Vent-free fireplace + 28,000 Btu/Hr Total = 68,000 Btu/Hr
63,300 Btu/Hr (maximum the space can support) 68,000 Btu/Hr (actual amount of Btu/Hr used)
103091
Continued
7
Page 8
AIR FOR
Or
Remove Door into Adjoining
Room, Option
3
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation
Grills
Into Adjoining
Room,
Option 1
12"
12"
COMBUSTION
AND
VENTILATION
Continued
WARNING
If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus­tion and ventilation air by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 3). You can also remove door into adjoining room (see option 3, Figure 3). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
WARNING
Rework worksheet, adding the space of the adjoining unconfined space. appliances in both spaces.
The combined spaces must have enough fresh air to supply all
8
Figure 3 - Ventilation Air from Inside Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two perma­nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.
IMPORTANT:
thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Do not provide openings for inlet or outlet air into attic if attic has a
Ventilated Attic
Crawl Space
Ventilated
To Attic
To
Crawl
Space
Outlet Air
Inlet Air
Outlet Air
Inlet Air
Figure 4 - Ventilation Air from Outdoors
103091
Page 9
INSTALLING
NOTICE
A qualified service person must install fireplace. Follow all local codes.
WARNING
Never install the fireplace
in a bedroom or bathroom
in a recreational vehicle
where curtains, furniture, clothing, or other flammable
objects are less than 36 inches from the front, top, or sides of the fireplace
in high traffic areas
in windy or drafty areas
WARNING
The GFP28TLP has a three-prong, grounded electrical plug. This plug helps protect you against electrical shock. Only connect plug to a properly grounded, three-prong receptacle. Do not cut or remove the grounding prong from this plug.
CAUTION
This fireplace creates warm air currents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating fireplace where impurities in the air (such as tobacco smoke) exist, may discolor walls.
IMPORTANT:
installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 6 through 8.
IMPORTANT:
not work properly.
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.
ELECTRICAL HOOKUP
The GFP28TLP has a blower assembly with an electrical cord. The electrical cord is five feet in length. You must locate fireplace within reach of a 120 volt grounded electrical outlet. If not, you must install an electrical outlet within reach of fire­place power cord.
Vent-free heaters add moisture to the air. Although this is beneficial,
Make sure the fireplace is level. If fireplace is not level, log set will
103091
Continued
9
Page 10
INSTALLING
Continued
ASSEMBLING AND ATTACHING BRASS TRIM
Note:
The instructions below show assembling and attaching brass trim to fireplace.
Do not yet install brass trim if performing a built-in installation (See Built-In Fireplace Installation, page 13).
1. Remove packaging from three pieces of brass trim.
2. Locate four brass screws, two adjusting plates with set screws, and two shims in the hardware packet.
3. Align shim under adjusting plate as shown in Figure 5.
4. Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 5).
5. Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 5).
6. While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver.
7. Repeat steps 1 through 6 for other side.
Side Brass Trim
Set Screws
Adjusting Plate
Top Brass Trim
Shim
Mitered Edge
Slot
Figure 5 - Assembling Brass Trim
Slot
8. Tighten trim hanging screws (#10 x 6.25 shoulder) into holes in cabinets. Place the assembled trim onto fireplace cabinet. Align hanging notches on trim with hanging screws on side of fireplace (see Figure 6). Push trim firmly into place, sliding hanging notches over hanging screws.
Trim Hanging Screws
Assembled Brass Trim
10
Hanging Notches on Trim
Figure 6 - Attaching Brass Trim to Fireplace
103091
Page 11
INSTALLING
INSTALLATION CLEARANCES
Continued
WARNING
Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Wall and Ceiling Clearances (see Figure 7)
A. Clearances from the side of the fireplace opening to any combustible wall should
not be less than 16 inches for a cabinet mantel or 12 inches for a corner installation.
B. Clearances from the top of the fireplace opening to the ceiling should not be
less than 42 inches.
MINIMUM CLEARANCE
Note: Clearances are the same if using optional cabinet mantel or built-in installation.
16"
Side Wall - 16 "
42"
Ceiling - 42" Floor - 0"
Figure 7 - Minimum Clearance to Wall and Ceiling
CONVENTIONAL FIREPLACE INSTALLATION
Conventional installation of this fireplace involves installing fireplace along with the corner, face, or cabinet mantel and hearth base accessories against a wall in your home. Follow the instructions below to install the fireplace in this manner.
WARNING
For conventional installation, it is recommended you use the cabinet mantel or hearth base specified in this manual. Surface clearances may not be sufficient with other cabinet mantels and hearth bases. This may create a fire hazard. See page 39 for correct mantels and hearth bases.
Note:
The instructions below show installation using the GM28MU series cabinet
mantel and the GFP28HBU hearth base accessories. The hearth base accessory shown is optional for this installation. You can install fireplace and cabinet mantel directly on the floor.
1. Assemble cabinet mantel and hearth base. Assembly instructions are included
with each accessory.
Accessories,
103091
Continued
11
Page 12
INSTALLING
Continued
2. Break off nailing flanges (see Figure 8) with hammer or pliers.
3. Place mantel and base in desired location. Place heater in front opening of mantel. Make sure all pieces fit properly. Remove mantel.
4. Mark floor and base or wall for gas line entrance. Make sure there is enough clearance between heater and mantel for gas line. IMPORTANT: Make sure there are no electrical lines where gas piping will go through floor or wall.
Nailing Flanges
Figure 8 - Location of Nailing Flanges
5. Place hearth base accessory against wall at installation location. Cut an access hole in hearth base top to run flexible gas line to fireplace (see Figure 9). Make sure to locate access hole so cabinet mantel will cover it when installed.
Note:
You can secure base to floor using wood screws. Countersink screw heads and putty over.
6. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 15.
Electrical Outlet
Hearth Base
Flexible Gas Line
Gas Line Access Hole
Figure 9 - Placing Hearth Base Accessory Against Wall
7. Carefully place fireplace on top of hearth base (Figure 10). Be careful not to
scratch or damage hearth base. Note: You can secure fireplace to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Secure with wood screws through these holes and into hearth or floor.
12
Figure 10 - Inserting Fireplace Into Cabinet Mantel
103091
Page 13
INSTALLING
Continued
8. Connect fireplace to gas supply (see page 17).
9. Check all gas connections for leaks. See Checking Gas Connections, page 18.
10. After heater is secured, replace mantel on hearth base (see Figure 11). Make
sure mantel is flush against wall. Install brass trim (see page 11).
Cabinet Mantel
Figure 11 - Installing Cabinet Mantel
BUILT-IN FIREPLACE INSTALLATION
Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, but you must follow the clearances shown in Figure 15, page 15. Follow the instructions below to install the fireplace in this manner.
Height Front Width Depth
Actual Framing Actual Framing Actual Framing
3
32
/8" 33" 34 5/16" 35 1/2" 16 11/16" 17 3/4"
1. Frame in rough opening. Use dimensions shown in Figure 12 for the rough
opening.
17 3/4"
33"
103091
35 1/2"
Figure 12 - Rough Opening for Installing in Wall
Continued
13
Page 14
INSTALLING
Continued
If installing in a corner, use dimensions shown in Figure 13 for the rough opening. The height is 33" which is the same as the wall opening, on page 13.
39 3/8"
27 7/8"
35 1/2"
55 5/8"
Figure 13 - Rough Opening for Installing in Corner
2. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 15.
3. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.
4. Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 17.
5. Route blower electrical cord through side or rear access door of fireplace. Plug electrical cord into electrical outlet.
6. Carefully insert fireplace into rough opening.
7. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 14).
8. Check all gas connections for leaks. See Checking Gas Connections, page 18.
9. Install brass trim after final finishing and/or painting of wall (see Figure 6, page 10).
14
Nails or Wood Screws
Nailing Flanges
Figure 14 - Attaching Fireplace to Wall Studs
103091
Page 15
INSTALLING
Continued
Mantel Clearances for Built-In Installation
If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
Mantel Shelf
10" 8" 6" 2
1
/2
"
Underside of Mantel Shelf
All minimum distances are in inches
20" 24
Distances to Underside of Mantel
1
/2
" 27
1
/2
" 30"
Top of Fireplace Opening
Figure 15 - Minimum Mantel Clearances for Built-In Installation
If your installation does not meet the above minimum clearances, you must:
• raise the mantel to an acceptable height, OR
• remove the mantel.
INSTALLING GAS PIPING TO FIREPLACE LOCATION
NOTICE
A qualified service person must connect fireplace to gas supply. Follow all local codes.
103091
CAUTION
Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.
Installation Items Needed
Before installing fireplace, make sure you have the items listed below.
• external regulator (supplied by installer, see Figure 16, page 16)
• piping (check local codes)
• sealant (resistant to LP gas)
• manual shutoff valve *
• test gauge connection *
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection.
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with gas connector
(if allowed by
local codes) (not provided)
Continued
15
Page 16
INSTALLING
Continued
The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure
16. Pointing the vent down protects it from freezing rain or sleet.
Propane/LP Supply Tank
External Regulator
Vent Pointing Down
Figure 16 - External Regulator With Vent Pointing Down
CAUTION
Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 17, page 17).
Check your building codes for any special requirements for locating manual shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.
CAUTION
Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.
Install sediment trap in supply line as shown in Figure 17, page 17. Locate sedi­ment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
16
103091
Page 17
INSTALLING
Continued
A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap
Approved Flexible Gas Line
3" Minimum
Figure 17 - Gas Connection
From External Regulator
(11" W.C. to 14" W.C.
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to LP gas, not provided)
Pressure)
Tee Joint Pipe Nipple Cap
Sediment
Trap
1. Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.
2. Remove access door from rear or side of fireplace. See Product Identification, page 4, for access door locations.
3. Remove screws that attach log base assembly to fireplace. Carefully lift up log base assembly and remove from fireplace (see Figure 18).
Note:
If adding the GFP28BK brick liner accessory, install it now. Follow instruc-
tions in GFB28BK accessory kit.
CAUTION
Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.
103091
Continued
Figure 18 - Removing Log Base Assembly From Fireplace
17
Page 18
INSTALLING
Continued
4. Route flexible gas line from manual shutoff valve into fireplace through side or rear access panel. Route flexible gas supply line through fireplace access door.
NOTICE
Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility from the fire­place. The flexible gas supply line connection to the manual shutoff valve should be accessible.
5. Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 19). Connect flexible gas line to flexible gas line attached to gas regulator of fireplace (see Figure 19).
6. Check all gas connections for leaks. See Checking Gas Connections, below.
7. Replace log base assembly back into fireplace. Feed flexible gas line into fireplace base area while replacing log base assembly. Make sure the entire flexible gas line is in fireplace base area. Reattach log base assembly to fire­place with screws removed in step 3.
18
To Fireplace Gas Regulator
Flexible Gas Line from Fireplace Gas Regulator
Gas Connector
Flexible Gas Line from Manual Shutoff Valve
Figure 19 - Attaching Flexible Gas Lines Together
Manual Shutoff Valve
To Propane/LP Tank
CHECKING GAS CONNECTIONS
WARNING
Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.
WARNING
Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage fireplace gas regulator.
2. Cap off open end of gas pipe where manual shutoff valve was connected.
3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.
4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Re-connect fireplace and manual shutoff valve to gas supply. Check re­connected fittings for leaks.
103091
Page 19
INSTALLING
Continued
Test Pressures Equal To or Less Than 1/2 PSIG
1. Close manual shutoff valve (see Figure 20).
2. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve.
3. Check all joints from propane/LP supply tank to manual shutoff valve (see Figure 21). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Pressure Testing Fireplace Gas Connections
1. Open manual shutoff valve (see Figure 20).
2. Open propane/LP supply tank valve.
3. Make sure control knob of fireplace is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve (see Figure
21). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light fireplace (see Operating Fireplace, pages 21 through 23 [Thermostat­controlled model] or pages 23 through 25 [Manually-controlled model]). Check all other internal joints for leaks.
7. Turn off fireplace (see To Turn Off Gas to Appliance, page 23, [Thermostat­controlled model] or page 25 [Manually-controlled model]).
Manual Shutoff Valve
ON
Open
POSITION
OFF
Closed
POSITION
Figure 20 - Manual Shutoff Valve
Manual Shutoff Valve
Propane/ LP Supply Tank
103091
Manual Gas Valve
Figure 21 - Checking Gas Joints
Continued
19
Page 20
INSTALLING
INSTALLING LOGS
Continued
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
1. Slide front log (#1) into place behind front burner. Make sure tabs at bottom of log are behind front burner (see Figure 22).
2 . Slide rear log (#2) into place behind rear burner (see Figure 23).
3. Place left front branch (#4) and right front branch (#5) (24" and 30" models) or front branch (#4) (18" model) into place (see Figure 24). Make sure notches on bottom rest on grates.
Front Log (#1)
Tab
20
Figure 22 - Installing Front Log
Rear Log (#2)
Figure 23 - Installing Rear Log
Left Branch (#4)
Right Branch (#5)
Figure 24 - Installing Rear Log
103091
Page 21
INSTALLING
Continued
WARNING
You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is in place before running fireplace.
5. Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 25).
103091
OPERATING
FIREPLACE
Thermostat-
Controlled Model
GFP28TLP
Notches
Figure 25 - Installing Fireplace Screen
Screws for Mounting Screen
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell
next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a
qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Continued
21
Page 22
OPERATING
FIREPLACE
Thermostat-
Controlled Model
Continued
LIGHTING INSTRUCTIONS
WARNING
You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.
NOTICE
During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.
1. STOP! Read the safety information on page 21.
2. Make sure manual shutoff valve is fully open.
Clockwise
3. Turn control knob clockwise
Ignitor Button
to the OFF position.
Control Knob
Figure 26 - Control Knob and Ignitor Button Location
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise control knob for five (5) seconds (see Figure 26, above).
Note:
If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system.
6. Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.
• If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7. This fireplace has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.
Note:
If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 23.
Thermocouple
to the PILOT position. Press in
C-clockwise
Ignitor Electrode
Pilot Burner
22
Figure 27 - Pilot
103091
Page 23
OPERATING
FIREPLACE
Thermostat-
Controlled Model
Continued
8. Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
TO TURN OFF GAS TO APPLIANCE
Shutting Off Fireplace
Turn control knob clockwise to the OFF position.
Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise to the PILOT position.
THERMOSTAT CONTROL OPERATION
You can set the thermostat control knob to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
Note:
Selecting the HI setting will cause the burner to remain on without modulating
down in most cases.
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, page 22.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, above.
BLOWER OPERATION
WARNING
This fireplace has a three-prong, grounded electrical plug. this plug helps protect you against electrical shock. Only connect plug to a properly grounded, three-prong receptacle. Do not cut or remove the grounding plug from this plug.
Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door.
The thermostat-controlled blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF position, the blower will not operate. In the AUTO postion, the blower will start when the thermostat senses a sufficient increase in firebox temperature.
Note:
Your gas logs and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
103091
It is safe to operate the fireplace with the burner turned off. However, the blower helps distribute heated air from the fireplace.
Continued
23
Page 24
OPERATING
FOR YOUR SAFETY READ BEFORE LIGHTING
FIREPLACE
Variable Manually
Controlled Model
WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob
will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
WARNING
You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.
NOTICE
During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.
1. STOP! Read the safety information on page 23.
2. Make sure manual shutoff valve is fully open.
3. Turn control knob clockwise
Control Knob
Clockwise
to the OFF position.
Ignitor Button
IGNITOR
24
Figure 28 - Control Knob and Ignitor Button Location
103091
Page 25
OPERATING
FIREPLACE
Variable Manually
Controlled Model
Continued
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
5. Slightly depress and turn control knob counterclockwise position. Press in control knob for five (5) seconds (see Figure 28, above).
Note:
If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system.
6. Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 25.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
• If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
C-clockwise
to the PILOT
Thermocouple
Figure 29 - Pilot
8. Slightly depress and turn control knob counterclockwise position. Both burners should light. Set control knob to either HIGH or LOW.
Ignitor Electrode
Pilot Burner
C-clockwise
to the HIGH
VARIABLE MANUAL CONTROL OPERATION
The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher settings produces greater heat output. This results in increased heating comfort.
WARNING
Do not operate heater between pilot and high positions.
103091
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
25
Page 26
OPERATING
FIREPLACE
Variable Manually
Controlled Model
Continued
TO TURN OFF GAS TO APPLIANCE
Shutting Off Fireplace
Clockwise
1. Turn control knob clockwise
2. Slightly depress control knob and turn clockwise
3. Slightly depress control knob and turn clockwise
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise
2. Press in and turn clockwise
Clockwise
to the HIGH position.
to the HIGH position.
Clockwise
to the PILOT position.
Clockwise
to the PILOT position.
Clockwise
to the OFF position.
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, page 24.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, above.
26
103091
Page 27
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 30 shows a correct pilot flame pattern. Figure 31 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.
Thermocouple
Figure 30 - Correct Pilot
Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 31
• turn fireplace off (see To Turn Off Gas to Appliance, page 23 [Thermostat­controlled model] or page 25 [Manually-controlled model])
• see Troubleshooting, pages 28 through 31
Pilot Burner
Thermocouple
Figure 31 - Incorrect Pilot
Flame Pattern
Pilot Burner
FRONT BURNER FLAME PATTERN
Figure 32 shows correct front burner flame pattern. Figure 33 shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.
WARNING
If front burner flame pattern shows yellow tipping, your fireplace could produce increased levels of carbon monoxide. Follow instruc­tions at bottom of this page. Yellow flame on rear burner is normal.
103091
NOTICE
Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by fireplace, causing brief patches of orange flame.
CORRECT FLAME PATTERN AT HIGH POSITION
Figure 32 - Correct Front Burner Flame Pattern
Yellow Tipping At Top of Blue Flame
INCORRECT FLAME PATTERN AT HIGH POSITION
Figure 33 - Incorrect Front Burner Flame Pattern
If front burner flame pattern is incorrect, as shown in Figure 33
• turn fireplace off (see To Turn Off Gas to Appliance, page 23 [Thermostat­controlled model] or page 25 [Manually-controlled model])
• see Troubleshooting, pages 28 through 31
27
Page 28
CLEANING
AND
MAINTENANCE
WARNING
Turn off fireplace and let cool before cleaning.
CAUTION
You must keep control areas, burners, and circulating air pas­sageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNERS
• Use a vacuum cleaner or small, soft bristled brush to clean.
LOGS
• If you remove logs for cleaning, refer to Installing Logs, pages 20 and 21, to properly replace logs.
• Replace log(s) if broken or chipped (dime-sized or larger).
TROUBLE-
SHOOTING
Note:
All troubleshooting
items are listed in order of
operation.
WARNING
Turn off fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.
CAUTION
Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
OBSERVED PROBLEM
When ignitor button is pressed, there is no spark at ODS/pilot
POSSIBLE CAUSE
1. Ignitor cable pinched or wet
2. Ignitor electrode not con­nected to ignitor cable
3. Piezo ignitor nut is loose
REMEDY
1. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry
2. Reconnect ignitor cable
3. Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel.
28
4. Broken ignitor cable
5. Ignitor electrode broken
6. Bad piezo ignitor
7. Ignitor electrode posi­tioned wrong
4. Replace ignitor cable
5. Replace ignitor
6. Replace piezo ignitor
7. Replace ignitor
Continued
103091
Page 29
TROUBLE-
SHOOTING
Continued
OBSERVED PROBLEM
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
POSSIBLE CAUSE
1. Gas supply turned off or manual shutoff valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in PILOT position
4. Air in gas lines when installed
5. ODS/pilot is clogged
6. Gas regulator setting is not correct
REMEDY
1. Turn on gas supply or open manual shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT position
4. Continue holding down control knob. Repeat igniting operation until air is removed
5. Clean ODS/pilot (see
Cleaning and Mainte­nance, page 28) or
replace ODS/pilot assembly
6. Replace gas regulator
ODS/pilot lights but flame goes out when control knob is released
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Manual shutoff valve not fully open
4. Thermocouple connec­tion loose at control valve
5. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot
6. Thermocouple damaged
7. Control valve damaged
8. On thermostat models, safety interlock system has been triggered
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds
3. Fully open manual shut­off valve
4. Hand tighten until snug, then tighten 1/4 turn more
5. A) Contact local natural gas company
B) Clean ODS/pilot (see
Cleaning and Mainte­nance, page 28) or
replace ODS/pilot assembly
6. Replace thermocouple
7. Replace control valve
8. Wait one minute for safety interlock system to reset. Repeat ignition operation
103091
29
Page 30
TROUBLE-
SHOOTING
Continued
OBSERVED PROBLEM
One or both burners do not light after ODS/ pilot is lit
POSSIBLE CAUSE
1. Burner orifice(s) clogged
2. Burner orifice(s) diameter is too small
3. Inlet gas pressure is too low
4. Mislocated crossover tube
REMEDY
1. Clean burner(s) (see
Cleaning and Mainte­nance, page 28) or replace
burner orifice(s)
2. Replace burner orifice(s)
3. Contact local propane/LP gas company
4. Contact qualified service person
Delayed ignition of one or both burners
Burner backfiring during combustion
Yellow flame in front burner during burner combustion
Slight smoke or odor during initial operation
1. Manifold pressure is too low
2. Burner orifice(s) clogged
3. Mislocated crossover tube
1. Burner orifice is clogged or damaged
2. Damaged burner
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
1. Residues from manu­facturing processes and logs curing
1. Contact local propane/LP gas company
2. Clean burner(s) (see
Cleaning and Mainte­nance, page 28) or replace
burner orifice(s)
3. Contact qualified service person
1. Clean burner (see Clean- ing and Maintenance, page
28) or replace burner orifice
2. Replace damaged burner
3. Replace gas regulator
1. Check burner(s) for dirt and debris. If found, clean burner(s) (see Cleaning and Maintenance, page 28)
2. Replace gas regulator
1. Problem will stop after a few hours of operation
30
Fireplace produces a whistling noise when burners are lit
Moisture/condensation noticed on windows
1. Turning control knob to HI position when burners are cold
2. Air in gas line
3. Air passageways on fireplace blocked
4. Dirty or partially clogged burner orifice(s)
1. Not enough combus­tion/ventilation air
1. Turn control knob to LO position and let warm up for a minute
2. Operate burners until air is removed from line. Have gas line checked by local propane/LP gas company
3. Observe minimum installation clearances (see page 11)
4. Clean burners (see
Cleaning and Mainte­nance, page 28) or replace
burner orifice(s)
1. Refer to Air for Combus-
tion and Ventilation
requirements (page 6)
Continued
103091
Page 31
TROUBLE-
SHOOTING
Continued
WARNING
If you smell gas
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM
Fireplace produces a clicking/ticking noise just after burners are lit or shut off
Fireplace produces unwanted odors
Fireplace shuts off in use (ODS operates)
Operating fireplace where impurities in air exist may create odors.
POSSIBLE CAUSE
1. Metal expanding while heating or contracting while cooling
1. Fireplace burning va­pors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See statement above)
2. Gas leak. See Warn-
ing statement above
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
IMPORTANT
REMEDY
1. This is common with most fireplaces. If noise is excessive, contact quali­fied service person
1. Open window and venti­late room. Stop using odor causing products while fireplace is running
2. Locate and correct all leaks (see Checking Gas Connections, page 18)
1. Open window and/or door for ventilation
2. Contact local natural gas company
3. Clean ODS/pilot (see
Cleaning and Mainte­nance, page 28)
103091
Gas odor even when control knob is in OFF position
Gas odor during combustion
Moisture/condensation noticed on windows
1. Gas leak. See Warn-
ing statement above
2. Control valve defective
1. Foreign matter be­tween control valve and burner
2. Gas leak.
ing statement above
1. Not enough combus­tion/ventilation air
See Warn-
1. Locate and correct all leaks (see Checking Gas Connections, page 18)
2. Replace control valve
1. Take apart gas tubing and remove foreign matter
2. Locate and correct all leaks (see Checking Gas Connections, page 18)
1. Refer to Air for Combus-
tion and Ventilation requirements (page 6)
31
Page 32
ILLUSTRATED
PARTS
BREAKDOWN
Log Base Assembly
Variable Manually
Controlled Models
1
4
2
5
19
10
6
12
6
14
8
11
6
21
8
7
7-1
7-2
27
13
8
18
9
8
23
16
26
22
6
24
32
GFP28MLP
6
15
30
20
3
19
28
31
17
25
29
103091
Page 33
PARTS LIST
Log Base Assembly
Variable Manually
Controlled Models
KEY NO. PART NUMBER DESCRIPTION QTY.
1 102230-02 Front Log (#1) 1 2 102231-02 Rear Log (#2) 1 3 102568-02 Control Valve 1 4 101332-01 Left Front Branch (#4) 1 5 101333-01 Right Front Branch (#5) 1 6 098304-01 Screw, #10 Phillips, Black 8 7 099059-02 O.D.S. Pilot 1 7-1 098594-01 Ignitor 1 7-2 098593-01 Thermocouple 1 8 098249-01 Nut 6 9 101006-01 Pilot Bracket 1 10 101330-05 Front Burner 1 11 100999-02 Rear Burner Assembly 1 12 102256-04BR Base Assembly 1 13 098271-06 Ignitor Cable 1 14 101924-01CB Firebox Bottom 1 15 098867-10 Gas Regulator 1 16 101004-01 Front Burner Injector 1 17 102445-01 Piezo Ignitor 1 18 101007-01 Crossover Tube 1 19 099387-05 Pilot Tube 1 20 101972-01 Valve and Piezo Bracket 1 21 M11084-38 Regulator Hex Screw 2 22 102668-01 Front Burner Tube 1 23 101008-01 Gasket 1 24 101973-01 Inlet Tube 1 25 098276-01 1/8" Plug 1 26 101004-10 Rear Burner Injector 1 27 M11084-26 Hex Screw, #10 2 28 098508-01 Valve Retainer Nut 1 29 101628-01 Flex Hose 1 30 097809-02 Adapter 1 31 098354-01 Control Knob 1
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 39 of this manual.
GFP28MLP
103091
PARTS AVAILABLE NOT SHOWN
100563-01 Warning Plate 1 101055-02 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 101416-23 Information Video 1 101976-02 Control Position Decal 1
33
Page 34
ILLUSTRATED
PARTS
BREAKDOWN
Log Base Assembly
Thermostat-
Controlled
Models
1
4
2
5
19
10
6
12
6
14
8
11
6
3
7
7-1
7-2
27
8
13
9
8
16
26
20
34
GFP28TLP
6
18
6
15
19
24
13
25
22
7-2
17
23
28
21
103091
Page 35
PARTS LIST
Log Base Assembly
Thermostat-
Controlled
Models
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 39 of this manual.
GFP28TLP
KEY NO. PART NUMBER DESCRIPTION QTY.
1 102230-02 Front Log (#1) 1 2 102231-02 Rear Log (#2) 1 3 M11084-38 Screw 2 4 101332-01 Left Front Branch (#4) 1 5 101333-01 Right Front Branch (#5) 1 6 098304-01 Screw, #10 Phillips, Black 8 7 099059-02 O.D.S. Pilot 1 7-1 098594-01 Ignitor 1 7-2 098593-01 Thermocouple 1 8 098249-01 Nut 4 9 101006-01 Pilot Bracket 1 10 101330-05 Front Burner Assembly 1 11 100999-02 Rear Burner Assembly 1 12 101392-02BR Base Assembly 1 13 098271-06 Ignitor Cable 1 14 101924-01CB Firebox Bottom 1 15 098867-10 Gas Regulator 1 16 101004-01 Front Burner Injector 1 17 102845-01 Inlet Tube 1 18 101382-01 Thermovalve Bracket 1 19 099387-03 Pilot Tube 1 20 102846-01 Burner Tube 1 21 097809-02 Adapter 1 22 099211-01 Screw 2 23 098544-01 Thermostat Clamp 1 24 101329-18 Thermostat Gas Valve Assembly 1 25 101381-01 Cover and Piezo 1 26 101004-10 Rear Burner Injector 1 27 M11084-26 Hex Screw, #10 2 28 101628-01 Flex Hose 1
103091
PARTS AVAILABLE NOT SHOWN
100563-01 Warning Plate 1 101054-01 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 101416-23 Information Video 1
35
Page 36
ILLUSTRATED
PARTS
BREAKDOWN
Fireplace
GFP28TLP
GFP28MLP
10
16
11
8
14
7
6
16
15
23
16
25
18
17
19
6
4
13
13
16
13
1
2
3
16
16
24
5
36
16
28
9
20
32
31
12
29
11
16
27
22
26
16
30
16
11
103091
Page 37
PARTS LIST
Fireplace
KEY PART NUMBER FOR MODEL NO. GFP28TLP QTY. GFP28MLP QTY. DESCRIPTION
1 101357-01 1 101357-01 1 Top Outer Casing 2 101373-01 1 101373-01 1 Outer Casing 3 102806-01CB 1 102806-01CB 1 Right Front Side 4 102805-01CB 1 102805-01CB 1 Left Front Side 5 101368-01 1 101368-01 2 Access Door 6 101352-01CB 1 101352-01CB 1 Top Front 7 101739-01CB 1 101739-01CB 1 Louver Hood 8 101375-03BR 1 101375-04BR 1 Firebox Wrapper 9 101738-01CB 1 101738-01CB 1 Lower Louver Assembly 10 101403-01 1 ——Top Duct 11 101348-01 2 101348-01 2 Firebox Support 12 101347-01CB 1 101347-01CB 1 Outer Base 13 099230-02 4 099230-02 4 Shoulder Screw 14 098304-01 15 098304-01 15 Phillips Pan Head Screw, #10 15 101872-02 1 101872-03 1 Firebox Top 16 M11084-26 6 M11084-26 61 Hex Screw, #10 17 101746-01 1 101746-01 1 Handle 18 100587-01 3 100587-01 3 Brass Screw, #6-20x3/8" 19 101784-01 2 101784-01 2 Snap-in Magnet 20 101367-02BR 1 101367-02BR 1 Screen Assembly 21 101404-01 1 ——Baffle 22 097384-02 2 ——Hex Nut #8-32 with Washer 23 101573-01 1 ——Back Duct with Bushing 24 101368-02 1 ——Rear Access Door 25 101614-01 1 ——Limit Switch (thermal disk)
26 101575-01 1 ——Motor Housing Assembly 27 099998-01 1 ——Fan Switch (Thermostat
28 101379-01 2 ——Fan 29 101408-01 2 ——Motor 30 099123-01 1 ——Wire Clip 31 098219-28 1 ——Power Cord Assembly 32 101398-01 1 ——Wire Harness
This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 39 of this manual.
GFP28TLP
GFP28MLP
Assembly
Models)
103091
PARTS AVAILABLE NOT SHOWN
102753-01 1 102753-01 1 Brass Trim Kit 100639-01 1 100639-01 1 Caution Decal 102865-01 1 102865-01 1 Brass Trim Hardware 101584-01 1 101584-01 1 Wiring Diagram Decal
37
Page 38
SERVICE
HINTS
When gas pressure is too low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
When gas quality is bad
• pilot will not stay lit
• burners will produce flames and soot
• fireplace will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.
SPECIFICA TIONS
TECHNICAL
SERVICE
WIRING
DIAGRAM
Btu (Low/High) 20,000/28,000 Type Gas Propane/LP Gas Only Ignition Piezo Manifold Pressure 8" W.C. Inlet Gas Pressure (in. of water)
Maximum 14" Minimum 11"
Shipping Weight 80 lbs.
You may have further questions about installation, operation, or troubleshooting. If so, contact Perfection-Schwank’s Technical Service Department at 1-800-776-8459 (Outside Georgia) or 706-554-2101.
Fan Switch
(Off/On/Auto)
Off
Auto
1
2
3
On
Red
Fan
Switch
(N.O.)
Black
38
110/115
V.A.C.
Black White
Green
Figure 36 - Blower Wiring Diagram for Thermostat-Controlled Models
Blue
Black
Black
Blower
Motor
Black
Blower
Motor
103091
Page 39
REPLACEMENT
PARTS
Note:
Use only original replacement parts. This will protect your warranty cover-
age for parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product. If they can’t supply original replace­ment part(s), call Perfection-Schwank’s Technical Service Department at 1-800-776-8459 (Outside Georgia) or 706-554-2101.
When calling Perfection-Schwank, have ready
• your name
• your address
• model number of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the defective part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they can’t supply original replace­ment part(s), call Perfection-Schwank’s Parts Department at 1-800-776-8459 (Outside Georgia) or 706-554-2101 for referral information.
When calling Perfection-Schwank, have ready
• model number of your fireplace
• the replacement part number
ACCESSORIES
Purchase these fireplace accessories from your local dealer or Parts Central. If they can not supply these accessories, call Perfection-Schwank’s Sales Depart­ment at 1-800-776-8459 (Outside Georgia) or 706-554-2101 for referral informa­tion. You can also write to the address listed on the back page of this manual.
CABINET MANTEL GM28MU - Unfinished
Mantel features moldings, fluted sides, and medal­lion. Available in unfinished hardwood, ready to stain or paint. Dimensions (H xW xD): 44" x 57-3/4" x 22-7/8"
HEARTH BASE GFP28HBU - Unfinished
The hearth base creates a handsome riser for the fireplace . Dimensions (H xW xD): 6-1/2" x 58" x 28-9/16"
103091
FIREBOX BRICK LINER - GFP28BK
Ceramic fiber firebox liner adds the look of real brick.
39
Page 40
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model Serial No. Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
PERFECTION-SCHWANK VENT-FREE PROPANE/LP GAS FIREPLACE
Perfection-Schwank warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition when provided by a Perfection-Schwank Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or Perfection-Schwank who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR ON ALL COMPO­NENTS FROM THE DATE OF FIRST PURCHASE; AND PERFECTION-SCHWANK’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND PERFECTION-SCHWANK SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSE­QUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write:
Perfection-Schwank, Inc. One Schwank Way at Hwy 56 P.O. Box 749 Waynesboro, Georgia 30830-0749 1-800-776-8459 (outside of Georgia) 706-554-2101
103091-01 Rev. A 7/96
Loading...