WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury, or
loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency, or the
gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause
injury or property damage. Refer to this manual for correct
installation and operational
procedures. For assistance or
additional information consult
a qualified installer, service
agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air
(oxygen) from the room in
which it is installed. Provisions
for adequate combustion and
ventilation air must be provided. Refer to
bustion and Ventilation
tion on page 4 of this manual.
Air for Com-
sec-
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
UNVENTED NATURAL GAS FIREPLACE
SAFETY
INFORMATION
WARNINGS
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate,
or service this fireplace. Improper
use of this fireplace can cause serious injury or death from burns, fire,
explosion, electrical shock, and
carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning:Early signs
of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If you
have these signs, the fireplace may not be
working properly. Get fresh air at once! Have
fireplace serviced. Some people are more affected by carbon monoxide than others. These
include pregnant women, people with heart or
lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An
odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this fireplace.
WARNING: Any change to
this heater or its controls can be
dangerous.
WARNING: Do not allow fans
to blow directly into the fireplace.
Avoid any drafts that alter burner
flame patterns. Ceiling fans can
create drafts that alter burner
flame patterns. Altered burner
patterns can cause sooting.
WARNING: Do not use a
blower insert, heat exchanger
insert, or other accessory not approved for use with this heater.
Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.
Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.
Fireplace front and screen become very hot when running fireplace. Keep children and adults
away from hot surfaces to avoid
burns or clothing ignition. Fireplace will remain hot for a time
after shut-down. Allow surfaces
to cool before touching.
Carefully supervise young children
when they are in the room with
fireplace. When using the optional
hand-held remote accessory, keep
selector switch in the off position
to prevent children from turning
on burners with remote.
You must operate this fireplace
with the fireplace screen and
hood in place. Make sure fireplace screen and hood are in
place before running fireplace.
Keep the appliance area clear and
free from combustible materials,
gasoline, and other flammable vapors and liquids.
1.This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
2.If you smell gas
• shut off gas supply
• do not try to light any appliance
•
do not touch any electrical switch; do
not use any phone in your building
• immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions
• if you cannot reach your gas supplier,
call the fire department
3.This fireplace shall not be installed in
a bedroom or bathroom.
4.Do not use this fireplace as a woodburning fireplace. Use only the logs
provided with the fireplace.
5.Do not add extra logs or ornaments
such as pine cones, vermiculite, or rock
wool. Using these added items can
cause sooting. Do not add lava rock
around base. Rock and debris could fall
into the control area of fireplace.
6.This fireplace is designed to be smokeless. If logs ever appear to smoke, turn
off fireplace and call a qualified service person.
eration, slight smoking could occur due
to log curing and fireplace burning
manufacturing residues.
7.T o prevent the creation of soot, follow
the instructions in Cleaning and Main-tenance, page 18.
8.Before using furniture polish, wax, carpet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white powder residue within burner box or on
adjacent walls or furniture.
9.This fireplace needs fresh air ventilation to run properly . This fireplace has
an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts
down the fireplace if not enough fresh
air is available. See Air for Combus-tion and Ventilation, pages 4 through
6. If fireplace keeps shutting off, see
Troubleshooting, pages 19 through 21.
10. Do not run fireplace
• where flammable liquids or vapors
are used or stored
• under dusty conditions
11. Do not use this fireplace to cook food
or burn paper or other objects.
12. Do not use fireplace if any part has been
exposed to or under water. Immediately
call a qualified service technician to
inspect the fireplace and to replace any
part of the control system and any gas
control which has been under water.
13. Do not operate fireplace if any log is
broken. Do not operate fireplace if a
log is chipped (dime-sized or larger).
14. Turn fireplace off and let cool before
servicing. Only a qualified service person should service and repair fireplace.
15. Operating fireplace above elevations of
4,500 feet could cause pilot outage.
Note:
During initial op-
2
105271
OWNER’S MANUAL
PRODUCT
IDENTIFICATION
WARMER
COOLER
TEMP
AUTO
ON
OFF
Optional Remote
Control
I
H
L
O
O
F
F
N
O
P
I
T
L
Control
Knobs
Piezo
Ignitor
Figure 1 - Log Base Assembly
Top Louver
Assembly
Firebox
Hood
Firebox
Support
O
Selector Switch
(Optional)
One Piece Log Set
Top Outer
Casing
LOCAL CODES
Install and use fireplace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel GasCode, ANS Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
CAUTION: Do not remove the
warning and instruction labels
attached to the heater base assembly. These markings contain
important warranty information.
1.With utility knife, cut the carton all the
way around above the staples on the
bottom tray. Lift the carton off the
heater. Remove packing.
hood is located in the packing on the
right hand side of the heater front. Lift
the heater off the bottom tray.
2.Locate two screws above top corners
of the fireplace screen. Remove and
discard these screws. Lift fireplace
screen up and pull out to remove.
3.Remove protective packaging applied to
logs, log base assembly , and fireplace.
4.Remove fireplace hood from carton
insert.
5.Check all items for any shipping damage. If damaged, promptly inform
dealer where you bought fireplace.
Note:
The
Screen
Assembly
Figure 2 - Fireplace
105271
Bottom Louver
Assembly
Blower Assembly
(Optional)
3
REMOTE CONTROL
ACCESSORIES
There are four optional remote controls that
can be purchased separately for this log
heater:
• wall switch
• wall thermostat
• hand-held ON/OFF remote
• hand-held thermostat remote
See Accessories, page 23.
UNVENTED NATURAL GAS FIREPLACE
PRODUCT
FEATURES
OPERATION
This vent-free fireplace is clean burning. It
requires no outside venting. There is no heat
loss out a vent or up a chimney. Heat is
generated by realistic, dancing yellow
flames. This heater is designed for vent-free
operation. It has been tested and approved to
ANS Z21.11.2 standard for unvented heaters. State and local codes in some areas
prohibit the use of vent-free heaters.
SAFETY DEVICE
This fireplace has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for
vent-free room heaters. The ODS system
shuts off the fireplace if there is not enough
fresh air.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This system requires no matches, batteries, or other
sources to light fireplace.
BLOWER ASSEMBLY
(GA3700 AND GA3700T
SERIES)
This fireplace accepts an optional blower
assembly. The GA3700 blower has a manual
variable control. The GA3700T blower operates thermostatically. The blower circulates heated air from the fireplace into the
room. Use of blower is optional. See Acces-sories, page 23.
AIR FOR
COMBUSTION AND
VENTILATION
WARNING: This heater shall
not be installed in a confined space
or unusually tight construction
unless provisions are provided
for adequate combustion and ventilation air. Read the following instructions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased
insulation, and new construction methods
help reduce heat loss in homes. Home owners
weather strip and caulk around windows and
doors to keep the cold air out and the warm air
in. During heating months, home owners
want their homes as airtight as possible.
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide adequate fresh air for these appliances. This
will insure proper venting of vented fuelburning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National
Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 4 through 6 will
help you classify your space and provide
adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a continuous water vapor retarder with
a rating of one perm (6 x 10
per pa-sec-m2) or less with openings gasketed or sealed
b. weather stripping has been
added on openable windows and
doors
c. caulking or sealants are applied
to areas such as joints around
window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and
gas lines, and at other openings.
If your home meets all of the three
criteria above, you must provide additional fresh air. See
From Outdoors
If your home does not meet all of the
three criteria above, proceed to
mining Fresh-Air Flow for Fireplace
Location
and
, page 6
on page 5.
Ventilation Air
.
and
Deter-
-11
kg
Confined Space and Unconfined
Space
The National Fuel Gas Code, ANS Z223.1
defines a confined space as a space whose
volume is less than 50 cubic feet per 1,000
Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed
in that space and an unconfined space as a
space whose volume is not less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space. Rooms
communicating directly with the space in
which the appliances are installed*, through
openings not furnished with doors, are considered a part of the unconfined space.
This heater shall not be installed in a confined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.
* Adjoining rooms are communicating only
if there are doorless passageways or ventilation grills between them.
4
105271
OWNER’S MANUAL
AIR FOR
COMBUSTION AND
VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1.Determine the volume of the space (length x width x height).
Length x Width x Height = _________________cu. ft. (volume of space)
Example:
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.
2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example:
3.Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free fireplace___________________ Btu/Hr
Gas water heater*___________________ Btu/Hr
Gas furnace___________________ Btu/Hr
Vented gas heater___________________ Btu/Hr
Gas fireplace logs___________________ Btu/Hr
Other gas appliances* +___________________ Btu/Hr
Total =___________________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_____________ Btu/Hr (maximum the space can support)
_____________ Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Rework work sheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-
ing room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 6.
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)
3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support)
Example:
Gas water heater
Vent-free fireplace+
Total=
63,300 Btu/Hr (maximum the space can support)
73,000 Btu/Hr (actual amount of Btu/Hr used)
40,000
33,000
73,000
Btu/Hr
Btu/Hr
Btu/Hr
WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space
or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of
the methods described in the
105271
National Fuel Gas Code, ANS Z223.1, Section 5.3
5
or applicable local codes.
Continued
UNVENTED NATURAL GAS FIREPLACE
AIR FOR
COMBUSTION AND
12"
VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside
Building
This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must provide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 3). You can also
remove door into adjoining room (see option 3, Figure 3). Follow the National Fuel
Gas Code, NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
WARNING: Rework worksheet, adding the space of the
adjoining unconfined space. The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.
Ventilation
Grills
Into Adjoining
Room,
Option 1
Figure 3 - Ventilation Air from Inside Building
Or
Remove
Door into
Adjoining
Room,
Option
3
12"
Outlet
Air
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilated
Attic
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two permanent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces. Follow the
National Fuel Gas Code, NFPA 54/ANS
Z223.1, Section 5.3, Air for Combustion
and Ventilation for required size of ventila-
tion grills or ducts.
IMPORTANT:
inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Do not provide openings for
Outlet
Air
Inlet
Air
Inlet Air
Figure 4 - Ventilation Air from Outdoors
To Attic
To
Crawl
Space
Ventilated
Crawl Space
6
105271
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your primary heating system. Do not install this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified service person must install fireplace.
Follow all local codes.
WARNING: Never install the
fireplace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the fireplace
• in high traffic areas
• in windy or drafty areas
OWNER’S MANUAL
Use the dimensions shown for rough openings to create the easiest installation. See
Built-In Fireplace Installation, page 9.
IMPORTANT:
ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-bustion and Ventilation, pages 4 through 6.
IMPORTANT:
level. If fireplace is not level, log set will not
work properly.
CHECK GAS TYPE
Use only natural gas. If your gas supply is
not natural gas, do not install fireplace. Call
dealer where you bought fireplace for proper
type fireplace.
ELECTRICAL HOOKUP
(Optional GA3700 and GA3700T
Series Blower Accessories)
This fireplace accepts a blower assembly
with an electrical cord. The electrical cord is
five feet in length. You must locate fireplace
within reach of a 120 volt grounded electrical
outlet. If not, you must install an electrical
outlet within reach of fireplace power cord.
INSTALLING HOOD
Install hood to top of firebox as shown in
Figure 5. Use 3 Phillips screws provided.
Vent-free heaters add mois-
Make sure the fireplace is
Note:
The instructions below show assem-
bling and attaching brass trim to fireplace.
1.Remove packaging from three pieces
of brass trim.
2.Locate four brass screws, two adjusting plates with set screws, and two
shims in the hardware packet.
3. Align shim under adjusting plate as
shown in Figure 6.
4.Slide one end of adjusting plate/shim
in slot on mitered edge of top brass trim
(see Figure 6).
5.Slide other end of adjusting plate/shim
in slot on mitered edge of side brass
trim (see Figure 6).
6. While firmly holding edges of brass
trim together, tighten both set screws
on the adjusting plate with slotted
screwdriver.
7.Repeat steps 1 through 6 for other side.
8. Tighten trim hanging screws (#10 x
6.25 shoulder) into holes in cabinets.
Place the assembled trim onto fireplace
cabinet. Align hanging notches on trim
with hanging screws on side of fireplace (see Figure 7). Push trim firmly
into place, sliding hanging notches over
hanging screws.
Side Brass
Trim
Set Screws
Adjusting
Plate
Top
Brass
Trim
CAUTION: This fireplace creates warm air currents. These currents move heat to wall surfaces
next to fireplace. Installing fireplace next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as tobacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.
Note:
Your fireplace is designed to be used
in zero clearance installations. Wall or framing material can be placed directly against
any exterior surface on the rear, sides, or top
of your fireplace, except where standoff
spacers are integrally attached. If standoff
spacers are attached to your fireplace, these
spacers can be placed directly against wall
or framing materials.
105271
Figure 5 - Installing Hood to Firebox
ASSEMBLING AND
ATTACHING OPTIONAL
BRASS TRIM
(Included with Mantel
Accessory)
IMPORTANT:
box in a wall, do not attach brass trim at this
time. See page 9.
If you are recessing the fire-
7
Shim
Mitered Edge
Slot
Figure 6 - Assembling Brass Trim
Assembled
Brass Trim
Figure 7 - Attaching Brass Trim to Fireplace
Slot
Trim
Hanging
Screws
Hanging
Notches
on Trim
Continued
UNVENTED NATURAL GAS FIREPLACE
INSTALLATION
Continued
INSTALLATION
CLEARANCES
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from
floor, ceiling, and adjoining wall.
Carefully follow the instructions below. This
will ensure safe installation.
Minimum Clearances For Side
Combustible Material, Side Wall,
and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 8.
Example:
shelf, etc. is made of combustible material and protrudes 3 1/2" from the wall.
This combustible material must be 4"
from the side of the fireplace opening
(see Figure 8).
B. Clearances from the top of the fireplace
opening to the ceiling should not be less
than 42 inches.
FIREBOX
*Minimum 16 inches from Side Wall
Figure 8 - Minimum Clearance for
Combustible to Wall
The face of a mantel, book-
Example
.52
14 6 8 10 12 14 16
INCHES
121/
101/
8
7
51/
31/
1
7/8
7/16
*
4
2
3
/
4
4
2
3
/
4
CONVENTIONAL FIREPLACE
INSTALLATION
Conventional installation of this fireplace
involves installing fireplace along with the
cabinet mantel with hearth base accessories
against a wall in your home. Follow the
instructions below to install the fireplace in
this manner.
Note:
The instructions below show installation using the GM101U cabinet mantel and
the G3001U series hearth base accessory.
The hearth base accessory shown is optional
for this installation. You can install fireplace and cabinet mantel directly on the
floor.
1. Assemble cabinet mantel and hearth
base. Assembly instructions are included with each accessory.
2.When installing blower, install a prop-
erly grounded, 120 volt, three-prong
electrical outlet at fireplace location if
an outlet is not there. If possible, locate outlet so cabinet mantel will cover
it when installed (see Figure 9).
3.Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the equipment shutoff
valve. The flexible gas line must be the
last item installed on the gas piping. See
Installing Gas Piping to Fireplace Location, page 10.
4. Place hearth base accessory against
INCHES
wall at installation location. Cut an access hole in hearth top to run flexible
gas line to fireplace (see Figure 9).
Make sure to locate access hole so cabinet mantel will cover it when installed.
Note:
You can secure base to floor using wood screws. Countersink screw
heads and putty over.
5.Route flexible gas line through access
hole in hearth base.
6.Center cabinet mantel on hearth base
(see Figure 10). Make sure mantel is
flush against wall.
7.Break off nailing flanges (see Figure
11, page 9) with hammer or pliers.
8. Place cardboard or other protective
material on top of hearth base. Carefully set fireplace on protective material, with back of fireplace inside mantel opening.
9.Attach flexible gas line to fireplace gas
regulator. See Connecting Fir eplace toGas Supply, page 11.
10. If blower is installed, route blower electrical cord through access holes in either side of fireplace.
Note:
Bushing
may be moved if necessary. Plug electrical cord into electrical outlet.
11. Carefully insert fireplace into cabinet
mantel. Be careful not to scratch or
damage hearth base or cabinet mantel.
Remove protective material from top
of hearth base and from front of fireplace (if any).
Note:
You can secure
fireplace to hearth or floor. Open lower
louver. Locate screw holes in bottom
of base. Tighten wood screws through
these holes and into hearth or floor.
12. Check all gas connections for leaks. See
Checking Gas Connections, page 12.
Cabinet
Mantel
Hearth
Base
Figure 9 - Placing Hearth Base Accessory
Against Wall
Flexible
Gas Line
Electrical
Outlet
8
Gas Line
Access
Hole
Figure 10 - Installing Cabinet Mantel
105271
OWNER’S MANUAL
INSTALLATION
Continued
Nailing
Flanges
Figure 11 - Location of Nailing Flanges
Figure 12 - Inserting Fireplace Into Cabinet
Mantel
BUILT-IN FIREPLACE
INSTALLATION
Built-in installation of this fireplace involves
installing fireplace into a framed-in enclosure. This makes the front of fireplace flush
with wall. If installing a mantel above the
fireplace, you must follow the clearances
shown in Figure 16, page 10 . Follow the
instructions below to install the fireplace in
this manner.
ActualFraming
3
Height32
Front Width 34
Depth16
/8"33"
5
/16"35 1/2"
11
/16"17 3/4"
WARNING: A qualified electrician must connect electrical wiring to duplex outlet for built-in
installation. Follow all local codes.
1.Frame in rough opening. Use dimensions shown in Figure 13 for the rough
opening.
2. If using blower, install wiring and
properly ground the three-prong, 120
volt electrical outlet in fireplace.
3. Route wires from electrical box
through smallest hole in outer casing
using strain relief fitting provided (see
Figure 14).
4.Connect wires from the electrical box
to duplex outlet. Match wire colors to
those indicated on duplex outlet. Be
sure to connect ground wire.
5.Plug blower cord into duplex outlet.
Note:
On thermostat model fireplaces,
route power cord to the back of the
fireplace to clear thermostat valve.
6.Replace bottom of firebox.
7.Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the equipment shutoff
valve. The flexible gas line must be
the last item installed on the gas piping. See Installing Gas Piping to Fire-place Location, page 10.
8. Carefully set fireplace in front of
rough opening with back of fireplace
inside wall opening.
17 3/4"
33"
35 1/2"
Figure 13 - Rough Opening for Installing
in Wall
9. Attach flexible gas line to gas supply.
See Connecting Fireplace to Gas Sup-ply, page 11.
10. Plug electrical cord into electrical outlet installed in step 2.
11. Carefully insert fireplace into rough
opening.
12. Attach fireplace to wall studs using
nails or wood screws through holes in
nailing flange (see Figure 15).
13. Check all gas connections for leaks. See
Checking Gas Connections, page 12.
14. Install brass trim after final finishing
and/or painting of wall (see Figure 7,
page 8).
Blower
Screw
Blower
Power
Cord
Figure 14 - Connecting Duplex Outlet
Nails or
Wood
Screws
Nailing Flanges
Figure 15 - Attaching Fireplace to Wall
Studs
Support
Bracket
Cable from
Electrical
Source
Duplex
Outlet
Strain Relief
Fitting
105271
Continued
9