Desa Tech CEF26, CGEF26, EV26L, VEF26 Owner's Manual

ELECTRIC FIREPLACE/INSERT
SAFETY INFORMATION AND INSTALLATION MANUAL
FOR MODELS CGEF26, CEF26, VEF26 and EV26L
Read these instructions completely before beginning installation. Failure to follow them could cause a heater malfunction resulting in serious injury and/or property damage.
WARNING: All electric heaters have hot and arcing or sparking parts inside. Do not use it in areas where gaso line, paint or flammable liquids are or are stored.
WARNING: This heater is tested and listed for use only with the optional accessories listed in these instruc­tions. Use of optional accessories not specifically tested for this heater could void the heater warranty and/or result in a safety hazard.
This fireplace meets the construction and safety stan dards of H.U.D. for application in manufactured homes when installed according to these instructions.
Save this manual for future reference.
For more information, visit www.desatech.com
-
-
TABLE OF CONTENTS
Safety Information ............................................... 2
Listing A
pprovals ................................................. 3
Product Dimension Specifications ....................... 3
Locating Fireplace ............................................... 4
Unpacking and Testing Fireplace ........................
Installation ........................................................... 5
Finishing .............................................................. 7

SAFETY INFORMATION

Operating Instructions ......................................... 7
Cleaning and Maintenance .................................. 8
Technical Service .............................................. 10
Replacement Parts ............................................ 10
Troubleshooting ..................................................
4
Warranty Information ............................
11
Back Page
WARNING: Improper installa­tion, adjustment, alteration, ser­vice or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer.
CAUTION: Do not expose the heater to the elements (such as rain, etc).
CAUTION: The fireplace insert unit is mounted on rubber feet. The purpose is to ensure adequate air circulation beneath unit. DO NOT remove these feet. Do not install directly on carpet, rug, furniture or similar surfaces which could hinder or block the air flow.
Due to high temperatures, the firebox should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near firebox. Never place any objects on the fireplace.
Carefully supervise young chil dren when they are in the room with fireplace.
Fireplace becomes very hot when running. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow sur faces to cool before touching.
When using electrical heaters, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
1. Read all instructions before using this heater.
2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from front of heater and keep them away from sides and rear.
3. Always unplug heater when not in use.
4. Do not operate any heater with a damaged cord or plug or after heater malfunctions, has been dropped or damaged in any way. Return heater to authorized service facility for examination, electrical or mechanical adjustment or repair.
5. Do not use outdoors.
6. This heater is not intended for use in bath rooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.
7. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Ar range cord away from traffic area and where it will not be tripped over.
8. To disconnect heater, turn controls to "OFF" before removing plug from outlet.
9. Do not insert or allow foreign objects to enter any
-
ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater.
10. To prevent possible fire, do not block air intakes in any manner.
11. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are used or stored.
-
-
-
2
www.desatech.com
116686-01A
26.75
27.5
21.26
12.75
4.33
SAFETY INFORMATION
FL
Continued
12. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
13. Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord should be No. 14 AWG minimum size and rated not less than 1875 WATTS.
14. Always use properly grounded fused and polarized outlets.
15. Always use ground fault protection where required by electrical codes.
16. Always disconnect power before performing any cleaning, maintenance or relocation of heater.
17. To prevent a possible fire, do not burn wood or other materials in this heater.
18 To prevent electric shock or fire, always use
a certified electrician should new circuits or outlets be required.
19. When transporting or storing heater, keep in a dry place free from excessive vibration and store as to avoid damage.
PRODUCT DIMENSION
SPECIFICATIONS
Figure 1 - Heater Dimensions
PRODUCT
IDENTIFICATION
Fuse

LISTING APPROVALS

This heater has been tested in accordance with the CSA Standards for fixed and location-dedicated electric room heaters in the United States. All components are UL or CSA safety certified.
If you need assistance during installation, please con tact your local dealer or the DESA Heating Products Technical Services Department at 1-866-672-6040.
Description: 26" Fireplace/Insert Voltage: 120 Watts: 1500 Amps: 15 Amp Grounded Circuit
Note: This heater must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric
Code ANSI/NFPA 70-latest edition or the dian Electric Code, CSA C2.1
116686-01A
as appropriate.
Back Glass
-
Cana-
Bottom Screen Screw
Bottom Panel
Figure 2 - Product Identification
www.desatech.com
Top Screen Screws
Heat Vents
Temp. Control Button and LED
ON/OFF Power Button
Flame Control Button and LED
3

LOCATING FIREPLACE

WARNING: Due to high tem­peratures, this heater should be located out of traffic. Keep combustible materials such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet (.9m) from the front of the heater.
Figure 3 illustrates a variety of ways the heater may be located in a room. The heater may be installed directly on the floor, carpet or raised on a hearth.
WARNING: Never locate this heater where it may fall into a bath­tub or other water container.
NOTICE: Minimum and maximum clearances must be maintained at all times. Illustrations throughout these instructions reflect typical installations and are for design purposes only. Actual installa­tions may vary slightly due to individual preferences.
WARN I N G : To pre v e n t contact with sagging or loose insulation, the heater must not be installed against vapor barrier or exposed insulation. Localized overheating could occur and a fire could result.
CAUTION: Do not expose the heater to the elements (such as rain, etc.)
CAUTION: Wear gloves and safety glasses for protection during installation and main­tenance.
Figure 3 - Heater Locations
UNPACKING AND
TESTING FIREPLACE
Carefully remove the unit from the box. Prior to permanently installing the unit, test to make sure the unit operates properly. To do this, plug the unit's power supply cord into a conveniently located 120-volt grounded outlet.
CAUTION; The unit's power supply cord must be connected to a properly grounded and pro tected 120-volt outlet. Always use ground fault protection where required by the electri cal code.
WARNING: Do not operate the unit if it is damaged or has malfunctioned. If you suspect the unit is damaged, return the unit to an authorized service facility for examination, electri­cal or mechanical adjustment or repair.
-
-