Desa Tech AC100LP, AC155LP Owner's Manual

AC-155LP SPACE HEATER
Introduction
THANK YOU for purchasing a John Deere product.
READ THIS MANUAL carefully to learn how to operate and service your machine correctly. Failure to do so could result in personal injury or equipment damage. This manual and safety signs on your machine may also be available in other languages. (See your John Deere dealer to order.)
THIS MANUAL SHOULD BE CONSIDERED a permanent part of your machine and should remain with the machine when you sell it.
MEASUREMENTS in this manual are given in both metric and customary U.S. unit equivalents. Use only correct replacement parts and fasteners. Metric and inch fasteners may require a specific metric or inch wrench.
GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJU RY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPOSITION, BURN, ASPHYXIATION, AND/OR CARBON MONOXIDE POISONING.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
WARNING: FIRE, BURN, INHALATION AND EXPLOSION HAZARD. KEEP SOLID COM BUS T IBL E S, SUC H AS BUI LDIN G MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
The SERIAL NUMBER is located in the Specification or Identification Numbers section. Accurately record all the numbers to help in tracing the machine should it be stolen. Your dealer also needs these numbers when you order parts. File the identification numbers in a secure place off the machine.
WARRANTY is provided from your John Deere dealer for customers who operate and maintain their equipment as described in this manual. The warranty is explained on the warranty certificate shown in this manual.
This warranty provides you the assurance that your dealer will back products where defects appear within the warranty period. Should the equipment be abused, or modified to change its performance beyond the original factory specifications, the warranty will become void.
The heater is designed for use as a construction heater in accordance with ANSI Z83.7/CGA 2.14. Other standards govern the use of fuel gases and heating products for specific uses. Your local authority can advise you about these. The primary purpose of construction heaters is to provide temporary heating of buildings under construction, alteration or repair. Properly used, the heater provides safe economical heating. Products of combustion are vented into the area being heated.
We cannot foresee every use which may be made of our heaters. Check with your local fire safety authority if
you have questions about heater use.
Other standards govern the use of fuel gases and heat producing products for specific uses. Your local authorities can advise you about these.
Propane gas is odorless. An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas can fade. Propane gas may be present even though no odor exists.
Install and use heater with care. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the Standard for Storage
and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and the Propane Installation Code, CAN/CGA B149.2. This instructs on the safe storage and handling
of propane gases.
WA RN I NG : NO T F OR H OME O R RECREATIONAL VEHICLE USE.
2 Operator’s Manual
Contents
Page
Safety ........................................................................ 4
Controls ................................................................... 9
Preparation ............................................................... 10
Installation ................................................................ 12
Operation ................................................................ 12
Troubleshooting
Service .................................................................... 16
Storage .................................................................... 17
Specifications ......................................................... 18
Wire Diagram ............................................................ 19
Warr
anty .................................................................. 20
Notes ........................................................................ 21
..................................................... 14
All information, illustrations and specifications in this manual are based on the latest
information available at the time of publication. The right is reserved to make changes at any
time without notice.
Operator’s Manual 3
W
A
R
N
I
N
G
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
C
A
U
T
I
O
N
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
Safety
RECOGNIZE SAFETY INFORMATION
This is the safety alert symbol. When you see this symbol on your machine or in this manual, be alert to the potential for personal injury.
Follow recommended precautions and safe operating practices.
UNDERSTAND SIGNAL WORDS
A signal word--DANGER, WARNING or CAUTION--is used with the safety-alert symbol. DANGER identifies the most serious hazards.
DANGER or WARNING safety signs are located near specific hazards. General precautions are listed on CAUTION safety signs. CAUTION also calls attention to safety messages in this manual.
FOLLOW SAFETY INSTRUCTIONS
Carefully read all safety messages in this manual and on your machine safety signs. Keep safety signs in good condition. Replace missing or damaged safety signs. Be sure new equipment components and repair parts include the current safety signs. Replacement safety signs are available from your John Deere dealer.
Read this owner’s manual carefully and completely before trying to assemble, operate, or service this space heater. Improper use of this space heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this space heater.
If you do no understand any part of this manual and need assistance, contact your John Deere dealer.
4 Operator’s Manual
CARBON MONOXIDE - POISONOUS GAS
DANGER: CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
Space heaters exhaust contains carbon monoxide - a poisonous gas that can kill you. You CAN NOT smell or see this gas.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the space heater may not be working properly. Get fresh air at once! Have space heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Never use a space heater in enclosed or partially-enclosed spaces without proper ventilation. Use only in well-vented areas. Before using space heater, provide at least a three-square-foot (2800 square cm) opening of fresh, outside air for each 100,000 Btu / Hr (30 kw) of rating. Space heaters can produce high levels of carbon mono
xide very quickly. When you use a space heater, remember that you cannot smell or see carbon monoxide. Even if you can’t smell exhaust fumes, you may still be exposed to carbon monoxide.
If you start to feel sick, dizzy, or weak while using a space heater, get to fresh air RIGHT AWAY. DO NOT DELAY. The carbon monoxide from space heaters can rapidly lead to full incapacitation and death.
If you experience serious symptoms, get medical attention immediately. Inform medical staff
that carbon monoxide poisoning is suspected. If you experienced symptoms while indoors, have someone call the fire department to determine when it is safe to re-enter the building.
NEVER operate the space heater in an explosive atmosphere, near combustible materials or where ventilation is not sufficient to carry away exhaust fumes. Exhaust fumes can cause serious injury or death.
NEVER run space heaters inside homes, garages, sheds, or other semi­enclosed spaces without proper ventilation. These spaces can trap poisonous gases EVEN IF you run a fan or open doors and windows. Use only in well­vented areas. Before using space heater, provide at least a three-square-foot (2800 square cm) opening of fresh, outside air for each 100,000 Btu / Hr (30 kw) of rating.
If you start to feel sick, dizzy, or weak while using the space heater, shut if off and get fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.
Install battery-operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up in your home, according to the manufacturer’s installation instructions. The carbon monoxide alarms should be certified to the requirements of the la (UL 2034, IAS 6-96, or CSA 6.19.01).
test safety standards for carbon monoxide alarms.
Test your carbon monoxide alarm frequently and replace dead batteries.
Operator’s Manual 5
ELECTRICAL HAZARDS
W
A
R
N
I
N
G
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
C
A
U
T
I
O
N
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
DANGER- IMPROPER CONNECTION OF THE EQUIPMENT­ GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTROCUTION. CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO WHETHER THE UNIT IS PROPERLY GROUNDED.
Use only the electrical voltage and frequency specified on model plate. The electrical connections and grounding of the heater shall follow the National Electric Code, ANSI/NFPA 70 or the Canadian Electrical Code, Part 1.
Space heater must be grounded. Use only a properly grounded three-wire extension cord. Plug into grounded outlet only. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
The space heater is a potential source of electrical shock if not kept dry. Keep the space heater dry and do not use in rain or wet conditions. To protect from moisture, operate it on a dry surface under an open, canopy-like structure. Dry your hands if wet before touching the space heater.
Check that the entire cord is free of cuts or tears and that the plug has all three prongs, especially a grounding pin.
IMPORTANT SAFETY INSTRUCTIONS
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
1. Use only in areas free of flammable vapors or high dust content.
2. Minimum heater clearances from combustible materials: Outlet: 8 Ft. (2.44 m), Sides: 2 Ft. (60.96 cm), Top: 6 Ft. (1.83 m), Rear: 2 Ft. (60.96 cm)
3. Locate space heater on a stable and level surface while hot or operating or a fire may occur.
4. Use only in well-vented areas. Before using space heater, provide at least a three-square-foot (2800 square cm) opening of fresh, outside air for each 100,000 Btu / Hr (30 kw) of rating.
5. Keep children and animals away from space heater at all times.
6. Use space heater only in accordance with local ordinances and codes.
7. Keep space heater area clear and free from combustible materials, gasoline, paint thinner and other flammable vapors and liquids.
8. Never use space heater in living or sleeping areas.
9. Never leave a space heater plugged in without adult supervision if children or animals are likely to be present. Do not leave heater unattended.
10. Never move, handle or service a hot or operating heater. Severe burns may result. You must wait 15 minutes after turning heater off.
6 Operator’s Manual
IMPORTANT SAFETY INSTRUCTIONS
W
A
R
N
I
N
G
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
W
A
R
N
I
N
G
S
I
N
T
H
E
M
A
N
U
A
L
S
.
C
A
U
T
I
O
N
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
O
C
A
U
T
I
O
N
S
I
N
O
T
H
E
M
A
N
U
A
L
S
11. Never attach duct work to front or rear of space heater.
12. Space heaters used in the vicinity of tarpaulins, canvas, or similar enclosure materials shall be located a safe distance from such materials. The recommended minimum safe distance is 10 feet (304.8cm). It is further recommended that these enclosure materials be of a fire retardant nature. These enclosure materials shall be securely fastened to prevent them from igniting or from upsetting the space heater due to wind action.
13. Unplug space heater when not in use.
14. Never block air inlet (rear) or air outlet (front) of space heater.
15. This product has been approved for use in the Commonwealth of Massachusetts.
16. Use only the hose and factory preset regulator provided with the heater.
17. Use only Propane / L.P. gas set up for vapor withdrawal.
18. For indoor use only. Do not use heater outdoors.
19. Do not use heater in basement or below ground level. Propane / L.P. gas is heavier than air. If a leak occurs, Propane / L.P. gas will sink to the lowest possible level.
20. Keep heater at least six feet from Propane / L.P. tank(s). Do not point heater at Propane / L.P. tank(s) within 20 feet.
21. Keep Propane / L.P. tank(s) below 100° F (37.8° C).
22. Check heater for damage before each use. Do not use a damaged heater.
23. Check hose before each use of heater. If highly worn or cut, replace with hose specified by manufacturer before using heater.
24. Keep heater away from strong drafts, wind, water spray, rain or dripping water.
25. To prevent injury, wear gloves when handling heater.
26. Do not alter heater. Keep heater in its original state.
27. Do not use heater if altered.
28. Turn off Propane / L.P. supply to heater when not in use.
29. Use only original replacement parts. This heater must use design­ specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries.
SAVE THESE INSTRUCTIONS
Operator’s Manual 7
WEAR PROTECTIVE CLOTHING
Wear close fitting clothing and safety equipment appropriate to the job.
Wear a suitable hearing protective device such as earmuffs or earplugs to protect against objectionable or uncomfortable loud noises.
Operating equipment safely requires the full attention of the operator. Do not wear radio or music headphones while operating machine.
PREPARE FOR EMERGENCIES
Keep a first aid kit and fire extinguisher handy. Keep emergency numbers for doctors, ambulance service,
hospital and fire department near your telephone. Be prepared if a fire starts.
INSPECT SPACE HEATER
Be sure all covers, guards and shields are tight and in place.
Locate all operating controls and safety labels. Inspect power cord for damage before using. There is a hazard of electrical shock from crushing, cutting or heat damage.
Remove all packing items applied to space heater for shipment. Remove all items from carton. Check items for
any shipping damage. If space heater is damaged, promptly inform dealer where you bought space heater.
SERVICE SPACE HEATER SAFELY
Before servicing the space hea
ter, disconnect all equipment
and battery (if equipped) and allow unit to cool down. Service space heater in a clean dry flat area.
8 Operator’s Manual
CONTROLS
A
B
C
D
E
F
G
H
I
J
AC-155LP
Controls
A -- Hot Air Outlet (Front) B -- Upper Shell C -- Handle
D -- Fan Guard E -- Power Cord F -- Thermostat Knob
G -- Hose / Regulator Assembly H -- Inlet Connector I -- On / Off Switch J -- Lower Shell
Operator’s Manual 9
Preparation
VENTILATION
WARNING: FOLLOW THE MINIMUM FRESH, OUTSIDE AIR VENTILATION REQUIREMENTS. IF PROPER FRESH, OUTSIDE AIR VENTILATION IS NOT PROVIDED, CARBON MONOXIDE POISONING CAN OCCUR. PROVIDE PROPER FRESH, OUTSIDE AIR VENTILATION BEFORE RUNNING HEATER.
Provide a fresh air opening of at least three square feet for each 100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used.
PROPANE SUPPLY
Propane / L.P. gas and Propane / L.P. tank(s) are to be furnished by the user.
Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage
and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58
and the Propane Installation Code CAN/CGA B149.2. Your local library or fire department will have this booklet.
The amount of Propane / L.P. gas ready for use from Propane / L.P. tanks varies. Two factors decide this amount:
1. The amount of Propane / L.P. gas in tank(s)
2. The temperature of tank(s) The chart below shows the number of 100 pound (45 kg)
tanks needed to run this heater. Smaller tanks can be used for limited run times but it is recommended to use larger tanks for optimum performance.
Temperature at Tank # of 100 lbs. Tanks
32°F (0°C) to 20°F (-6.7°C) 2 20°F (-6.7°C) to -10°F (-23.3°C) 3 Below -10°F (-23.3°C) (Use larger tank)
Less gas is vaporized at lower temperatures. You may need two or more 100 pound (45 kg) tanks or one larger tank in colder weather. Your local Propane / L.P. gas dealer will help you select the proper supply system. The minimum surrounding air temperature rating for each heater is -20° F (-29° C).
10 Operator’s Manual
Preparation
Air For Combustion And Heating
Fuel
Combustion Chamber
Ignitor
Clean Heated Air Out (Front)
Cool Air In (Back)
Fan
Motor
Power Cord
Hose/ Regulator Assembly
Solenoid Valve
On/Off Switch
DSI
Nozzle
THEORY OF OPERATION
The Fuel System: The hose / regulator assembly attaches to the Propane / L.P. gas supply. The Propane / L.P.
gas moves through the solenoid valve and out the nozzle.
The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The direct spark ignitor (DSI) sends voltage to the spark plug/ignitor. The spark plug / ignitor ignites the fuel and air mixture.
The Safety Control System: This system causes the heater to shut down if the flame goes out.
Operator’s Manual 11
Installation
Propane Tank
Hose
Regulator
Vent (pointing down)
POL Fitting
Supply Valve
Hose
Inlet Connector
INSTALLATION
IMPORTANT: Review and understand the warnings in the Safety Information section. They are needed to safely operate this space heater. Follow all local ordinances and codes when using this space heater.
WA RN I NG: TEST ALL GAS PIP ING AND CONNECTIONS FOR LEAKS AFTER INSTALLING OR SERVICING. NEVER USE AN OPEN FLAME TO CHECK FOR A LEAK. APPLY A MIXTURE OF LIQUID SOAP AND WATER TO ALL JOINTS. BUBBLES FORMING SHOW A LEAK. CORRECT ALL LEAKS AT ONCE.
1. Provide propane supply system (see Propane Supply section).
2. Connect POL fitting on hose / regulator assembly to Propane / L.P. tank(s). (Fig. 1) Turn POL fitting counterclockwise into threads on tank. Tighten firmly using wrench. Tighten regulator with vent pointing down.
3. Connect hose to inlet connector. Tighten firmly using a wrench. (Fig. 2)
IMPORTANT: Extra hose or piping may be used if needed.
Install extra hose or piping between hose/regulator assembly and Propane / L.P. tank. You must use the regulator supplied with heater.
4. Open propane supply valve on Propane / L.P. tank(s) slowly.
Note: If not opened slowly, excess-flow check valve on
Propane / L.P. tank will stop gas flow. If this happens, close propane supply valve and open again slowly.
5. Check all connections for leaks.
6. Close propane supply valve.
(Fig. 1)
(Fig. 2)
OPERATION
WARNING: FOLLOW THE MINIMUM FRESH, OUTSIDE AIR VENTILATION REQUIREMENTS. IF PROPER FRESH, OUTSIDE AIR VENTILATION IS NOT PROVIDED, CARBON MONOXIDE POISONING CAN OCCUR. PROVIDE PROPER FRESH, OUTSIDE AIR VENTILATION BEFORE RUNNING HEATER.
START SPACE HEATER:
1.
2. Place the space heater in an area that provides
3. Locate heater on stable and level surface. Make sure
4. Plug power cord of heater into a three-prong, grounded
12 Operator’s Manual
Operation
Follow all ventilation and safety information.
maximum circulation of the heated air. Follow all location requirements noted in the Safety Information.
strong drafts do not blow into front or rear of heater.
extension cord. Extension cord must be at least 6 feet (1.83 m) long, UL listed and of a proper size. See Extension Cord Chart.
Extension Cord Size Requirement
Length of Cord: Rated Cord: Up to 50 feet (15 m) 18 AWG 51 to 100 feet (15.5 to 30.48 m) 16 AWG 101 to 200 feet (30.78 to 60.96 m) 14 AWG
Operation
OPERATION
5. Plug extension cord into a 120 volt/60 hertz, 3-hole, grounded outlet.
6. Open propane supply valve on Propane / L.P. tank(s) slowly.
Note: If not opened slowly, excess-flow check valve on
Propane / L.P. tank will stop gas flow. You may hear a click from the excess-flow check valve closing. If this happens, reset the excess-flow check valve by closing propane supply valve and open again slowly.
7. Turn thermostat control knob fully counterclockwise to the "cooler" position. Turn ON/OFF switch to the ON position. Turn thermostat control knob slowly clockwise until electric motor and fan begin to run. Heater will start in approximately 3 seconds. Adjust thermostat control knob to warmer or cooler setting as needed.
Note: If heater does not start after 3 seconds, the ignition
control will automatically attempt to start heater one time. If heater fails to start on this attempt, the safety control will "lock out" and no further automatic restarts will be attempted. This could occur if air remains in fuel line. If heater fails to start on this attempt, turn ON/OFF switch to OFF position. Wait ten seconds for safety control to reset, then turn ON/OFF switch back to ON position and try to start heater again.
8. Thermostat Operation Only: During normal thermostat operation, heater will cycle off when air temperature rises to thermostat setting. When air temperature drops sufficiently below thermostat setting, the electric motor and fan will begin to run. After 15 to 60 seconds, heater burner should automatically ignite and provide heat to maintain temperature setting.
STOP SPACE HEATER:
1. Tightly close propane supply valve on Propane / L.P. tank(s).
2. Wait a few seconds. Heater will burn gas left in supply hoses.
3. Turn ON/OFF switch to the OFF position.
4. Unplug heater.
Operator’s Manual 13
Troubleshooting
WARNING: HIGH VOLTAGE. NEVER SERVICE SPACE HEATER WHILE IT IS PLUGGED IN, OPERATING, OR HOT. SEVERE BURNS AND ELECTRICAL SHOCK CAN OCCUR.
Symptom Problem Solution
Fan does not turn when heater is plugged in.
Heater will not ignite.
No electrical power to heater.
Fan hitting inside of heater shell.
Fan blades bent.
Defective motor.
User did not follow installation or operation instructions properly.
Check voltage to electrical outlet. If volt­age is good, check heater power cord for breaks.
Adjust motor / fan mount to keep fan from hitting inside of heater shell.
Replace fan.
Replace motor.
Repeat installation and operation instructions.
No spark at ignitor. To test for spark, see "Maintenance: Ignitor" and follow step 8. If you see spark at ignitor, have heater serviced by qualified service person. If no spark seen:
a. Loose or disconnected ignitor wire
b. Wrong spark gap
c. Bad ignitor electrode
d. Bad spark transformer
a. Check ignitor wire. Tighten or reattach loose ignitor wire. See "Maintenance: Spark Transformer" for ignitor wire location
b. Set gap between ignitor electrode and nozzle to .13"/.15" (3.3/3.8 mm)
c. Replace ignitor electrode. See "Maintenance: Ignitor".
d. Replace spark transformer. See "Maintenance: Spark Transformer".
14 Operator’s Manual
Troubleshooting
WARNING: HIGH VOLTAGE. NEVER SERVICE SPACE HEATER WHILE IT IS PLUGGED IN, OPERATING, OR HOT. SEVERE BURNS AND ELECTRICAL SHOCK CAN OC
CUR.
Symptom Problem Solution Heater shuts down while
running.
Propane / L.P. supply may be inadequate.
High surrounding air temperature causing thermal limit device to shut down heater.
Restricted air flow.
Damaged fan.
Excessive dust or debris in surrounding area.
WARNING: Use only in areas free
a. Refill tank b. Provide additional and/or larger tanks. See "Preparation: Propane Supply".
This can happen when running heater in temperatures above 85° F (30° C). Run heater in cooler temperatures.
Check heater inlet and outlet. Re­move any obstructions.
Replace fan. See "Maintenance: Fan".
Clean heater. See "Maintenance".
of high dust content.
Heater producing odor.
Gas leak.
Heater operating on a 20 lb. Propane / L.P. cylinder. Insufficient Propane / L.P. gas will be supplied by a 20 lb. cylinder resulting in odor.
Propane / L.P. supply tank is "freez ing up". Evaporation and consump­tion rate of Propane / L.P. from supply tank is to great for the size of the tank and air temperature.
Check all connections for leaks. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected
To obtain correct mixture of Propane / L.P. gas and air, use a larger cylinder size, i.e. 100 lb. See "Preparation: Propane Supply".
Use a larger supply cylinder size,
­i.e. 100 lb.
Operator’s Manual 15
Service
MAINTENANCE:
WARNING: TO AVOID RISK OF BURN AND ELECTRICAL SHOCK, NEVER ATTEMPT TO SERVICE SPACE HEATER WHILE IT IS PLUG G ED I N, OP ER AT I NG , OR HOT .
KEEP HEATER CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS
DO NOT BLOCK THE FLOW OF COMBUSTION OR VENTILATION AIR.
1. Keep heater clean. Clean heater annually or as needed to remove dust and debris. If heater is dirty or dusty, clean heater with a damp cloth. Use household cleaners on difficult spots.
2. Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.
3. Inspect hose / regulator assembly before each use. If hose is highly worn or cut, replace with hose specified by manufacturer.
4. Have heater inspected yearly by a qualified service agency.
5. Keep inside of heater free from combustible and foreign objects. Remove motor and other internal parts if needed to clean inside of heater.
6. Clean fan blades each season or as needed.
WARNING: NEVER SERVICE HEATER WHILE IT IS P LUG GE D IN , CO N NE CTE D TO P RO PA NE SU P PLY, OP E RAT I NG OR HOT. SEVERE BURNS AND ELECTRICAL SHOCK CAN OCCUR.
UPPER SHELL REMOVAL:
1. Remove screws along each side of heater using 5/16"
nut-driver. These screws attach upper and lower shells together. (Fig. 3)
2. Lift or slide upper shell off.
3. Remove fan guard.
(Fig. 3)
16 Operator’s Manual
Service
Fan
Motor
Motor Shaft
Fan
Setscrew
Fan
Hub
Setscrew
Motor Shaft
MAINTENANCE (CONTINUED):
:
FAN
IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch.
1. Remove upper shell.
2. Use 1/8" hex wrench to loosen setscrew which holds fan to motor shaft.
3. Slip fan off motor shaft. (Fig. 4 & 5)
4. Clean fan using soft cloth moistened with kerosene or solvent.
5. Dry fan thoroughly.
6. Replace fan on motor shaft. Make sure setscrew is touching back of flat surface on motor shaft (Fig. 6).
7. Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds).
8. Replace fan guard and upper shell.
(Fig. 4)
(Fig. 5)
IGNITOR: Make sure gap between ignitor electrode and burner nozzle is 0.13/0.15". Access ignitor electrode from inside combustion chamber. No other maintenance is needed for ignitor.
(Fig. 6)
Storage
CAUTION: DISCONNECT HEATER FROM
PROPANE L.P. SUPPLY TANK(S).
1. Store Propane / L.P. tank(s) in safe manner. See Chapter 5 of Standard for Storage and Handling of Liquefied
Petroleum Gases, ANSI/NFPA 58 Installation Code CAN/CGA B149.2. Follow all local
codes. Always store Propane / L.P. tanks outdoors.
2. Place plastic cover caps over brass fittings on inlet connector and hose / regulator assembly.
3. Store in dry, clean and safe place. Do not store hose / regulator assembly inside heater combustion chamber.
4. When taking heater out of storage, always check inside of heater. Insects and small animals may place foreign objects in heater. Keep inside of heater free from combustible and foreign objects.
Operator’s Manual 17
and the Propane
Specifications
ITEM SPECIFICATION
Model Size AC-155LP
Output Rating (BTU / Hr) 150,000
Fuel Propane Vapor Only
Fuel Consumption: (Gal. Per Hr / Liters Per Hr) 1.6 / 6.1 (Pounds Per Hr / Kilograms Per Hr) 7.0 / 3.2
Supply Pressure to Regulator: Minimum (for input adjustment) 10 PSI / 65.98 kPa Maximum Tank Pressure
Regulator Outlet Pressure Factory Preset @ 12.5" WC / 31.8 cm
Manifold Pressure 9.8" WC / 24.9 cm
Hot Air Output (Approx.) 550 CFM / 15.6 cubic meter / minute
Motor RPM 3450
Motor HP 1/8
Electric Input 120V / 60Hz
Amperage (Normal Run) 2.2
Ignition Electronic Direct Spark, D.S.I.
Ignitor Gap 0.13 in / 0.15 in (3.3 mm / 3.8 mm)
Shipping Weight (Approximate Pounds / Kilograms) 35 / 15.9
Space Heater Weight (Approximate Pounds / Kilograms) 27 / 12.2
RECORD SERIAL NUMBER
Write you model number, machine serial number and date of purchase in the spaces provided below. Your dealer needs this information when ordering parts.
Model No. ______________________________________________
Machine Serial No. _______________________________________
Date of Purchase ________________________________________ (To be filled in by purchaser)
18 Operator’s Manual
Electrical Connection Diagram
Electrical Ladder Diagram
Wire Diagram
Operator’s Manual 19
STATEMENT OF WARRANTY
John Deere warrants all parts, (except those referred to below), of your new space heater to be free from defects in materials and workmanship during the following periods:
For One (1) Year from the date of original purchase.
Defective parts not subject to normal wear and tear will be repaired or replaced at our option during the warranty period. In any event, reimbursement is limited to the purchase price paid.
EXCLUSIONS
1. This warranty does not cover parts damaged due to normal wear, misapplication, misuse, operation at other than recommended. Failure to follow recommended operating and maintenance procedures also voids warranty.
2. The use of other than genuine manufacturer repair parts will void warranty.
3. Warranty will be void if used in any application other than consumer / homeowner. Parts returned, prepaid to our factory or to an Authorized John Deere Service Center will be inspected and replaced free of charge if found to be defective and subject to warranty. There are no warranties which extend beyond the description of the face hereof. Under no circumstances shall the manufacturer bear any responsibility for loss of use of the unit, loss of time or rental, inconvenience, commercial loss or consequential damages.
For Service or Warranty Consideration, contact
Mi-T-M
®
Corporation, 8650 Enterprise Drive, Peosta, IA 52068
1-877-JD-KLEEN / (1-877-535-5336) Fax 563-556-1235
Monday - Friday 8:00 a.m. - 5:00 p.m. CST
20 Operator’s Manual
Loading...
+ 44 hidden pages