Desa Tech 80-VCNG, SPC-80VCA-NG Owner's Manual

SCHEU PRODUCTS COMPANY, INCORPORATED
Mail: P.O. Box 250, Upland, CA 9l785
Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730
Telephone: 909-981-5343
ASSEMBLY AND OPERATING INSTRUCTIONS
MODELS 80 VCA-NG/SPC80 VCA-NG
CONSTRUCTION HEATER
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPER­ATE THIS HEATER.
SO
! GENERAL HAZARD WARNING:
Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic.
CO can build up in a heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation are:
headache dizziness burning eyes and nose nausea
dry mouth or sore throat So, be sure to follow advice about ventilation in these operating instructions.
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
! WARNING: FIRE, BURN, INHALATION, AND EXPLO­SION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS
BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS
RECOMMENDED BY THE INSTRUCTIONS. NEVER USE
THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
OPERATING INFORMATION
INTENDED USE IS PRIMARILY THE TEMPORARY
HEATING OF BUILDINGS UNDER CONSTRUCTION,
ALTERATION OR REPAIR.
!
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
SAFETY PRECAUTIONS
1. Check the heater thoroughly for damage. DO NOT operate a damaged heater.
2. DO NOT modify the heater or operate a heater which has been modified from its original condition.
3. Use only natural gas.
4. Provide at least 5" W.C. but not over 1/2 psig to the heater inlet (regulator inlet).
5. Use an appropriate hose or flexible connector not over 10 ft. in length.
6. Operate the heater only with the 4" W.C. regulator provided by the factory.
7. For indoor use only. Area must be well ventilated. Provide minimum openings of 2 sq. ft. near the floor and 2 sq. ft. near the ceiling (also see "Operating Precautions").
8. If at any time gas odor is detected, IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected.
9. Install the heater such that it is not directly exposed to water spray, rain and/or dripping water.
10. Maintain minimum clearance from normal combustible material (like paper) as follows: sides-4 ft.; top-6 ft.. Locate 10 ft.from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action.
11. Operate only on a stable, level surface.
12. Caution: Do not touch heater surface during operation or for 30 minutes after shutdown. It can cause serious burns.
13. Operate the unite in a draft free area or protect the heater from drafts.
13. Do not move, handle or service while hot or burning.
14. Use only in accordance with local codes.
This is a natural gas, direct-fired heater. Natural gas leaks should be avoided, so set up the gas supply
with utmost care. Leak check new connections with a soap and water solution and follow all connection instructions herein. Also, ask your gas supplier for advice on the supply installation and ask him to check it if there are any questions.
80 VCA-NG
OPERATING INSTRUCTIONS
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage. If any is found, immediately notify your dealer.
2. Follow all of the "Safety Precautions" and "Operating Infor­mation on page 1.
3. Install plumbing to a low pressure (1/2 psig maximum) source of natural gas, using a minimum 3/4" i.d. hose or flexible connector not over 10 feet in length.
4. Connect the hose to the heater at the 1/2" SAE flare fitting at the inlet.
5. Securely tighten all gas connections.
6. Open the gas cock and check all gas connections with a soap and water solution. DO NOT USE A FLAME.
START
1. WARNING: BEFORE LIGHTING PILOT, fully close the main burner valve by rotating the handle clockwise.
2. Fully open the gas cock at the natural gas source.
3. Depress red button on safety pilot valve admitting gas to the pilot. Then push and release the ignition button until the pilot lights.
4. When the pilot lights, continue to hold the gas valve button depressed for 30 seconds, then release.
5. If the pilot goes out, wait 5 minutes and repeat the lighting procedure.
6. When the pilot remains lit, open main burner valve to operate the heater. Partially close valve to regulate heat output.
CAUTION: ADJUSTING BURN RATE too low can cause soot. Watch for and avoid a yellow smoky flame.
SERVICING
A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:
* The flame is contained within the heater. * The flame is predominantly yellow.
* There is no strong disagreeable odor, eye burning or
other physical discomfort.
* There is no smoke or soot internal or external to the
heater.
* There are no unplanned or unexplained shutdowns of the
heater. The parts list shows the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the 4" W.C. regulator supplied with the heater. Do not use alternates. For this heater, the regulator must be set to supply 11" WC outlet pressure. If there is any uncertainty about the regulator setting, have it checked.
A heater which is not working right must be repaired, but only by a trained, experienced service person. Contact the factory for the service center closes to you, phone number (909) 981-5343. Please have the following information when you call:
Heater Model: Heater Serial Number:
STOP
1. Securely close the gas cock at the natural gas source.
2. Close the ball valve.
RESTART AFTER SAFETY SHUTDOWN
1. Securely close the gas cock at the natural gas source.
2. Wait 5 minutes.
3. Restart following "Start" procedure.
MAINTENANCE AND STORAGE
1. The heater should be inspected before each use, and at least annually by a qualified person.
2. Before each use, check the soft "O" ring seat at the bullnose of the POL fitting. If the "O" ring is cut, scuffed, or otherwise damaged, replace it with part number 6681.
Date of Purchase: Location of Purchase:
You may also obtain in-warranty or out-of-warranty service by returning the product freight prepaid to :
Scheu Products Company
8855 Baker Avenue
Rancho Cucamonga, CA 91730
In-warranty products returned to the Service Department will be repaired with no charge for either parts or labor and will be returned to you freight prepaid. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.
Out-of-warranty products returned to the Service Depart­ment will be repaired with a charge for parts and labor and will be returned to you freight collect.
! CAUTION
When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions, and of the hazards in­volved.
Page 2
Loading...
+ 2 hidden pages