HEATER SPECIFICATIONS................................................................................................................ 2
WARNINGS .................................................................................................................................. 2
OPERATING PRECAUTIONS............................................................................................................. 3
SAFETY PRECAUTIONS.................................................................................................................... 3
ODOR FADE WARNING...................................................................................................................... 4
OPERATING INSTRUCTIONS ............................................................................................................ 5
SERVICING ......................................................................................................................................... 5
SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED ....................................................... 6
WIRING DIAGRAMS............................................................................................................................ 7
80-FAC - PARTS.................................................................................................................................. 8
WARRANTY......................................................................................................................................... 9
SERVICE CENTERS .......................................................................................................................... 9
INSTRUCTIONS FOR ORDERING PARTS ........................................................................................ 9
WARRANTY REGISTRATION ...........................................................................................................10
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
© 2002 Scheu Products Company
MODEL
80-FAC
HEATER SPECIFICATIONS
Type of Gas: For use with Propane Only Gas Supply Pressure
to regulator Maximum: Bottle Pressure Minimum: 5 psig (34.5 kPa) regulator out 11"WC (2.74 kPa)
Electrical Input: 115V, 60 Hz, 1Ø, 3a Minimum Operating Voltage: 100V Ignition: Direct Spark, interrupted type Primary Flame Control: Solid State, 10-15 Second Timing
High Temperature Control: 240°F (116°C) Minimum Ambient Temp. Rating 0°F (-17.8°C) Model: 80-FAC
Rating: 80,000 BTU/hr
(23.4 kW) Fuel Consumption: 3.7 #/hr Fuel Orifice Port No.: 18
Fuel Orifice Port Size: #69 Drill Heated Air Output: 350 cfm Average Air Temp. Rise:
(1.68 kg/hr)
(9.91cmm)
W ARNINGS
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE
READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS
BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
Scheu Products Company, Incorporated
Mail: P.O. Box 250, Upland, CA 91785
Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730
Telephone: 800-325-7057
www.scheuco.com
customerservice@scheuco.com
8694
September 2002ANSI Z83.7/CGA 2.14-2000
Page -3-
MODEL
80-FAC
OPERATING PRECAUTIONS
This is a propane, direct-fired, forced air heater. It's intended use is primarily temporary heating of buildings under construction, alteration or repair.
Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the floor, collecting there with the surrounding air, forming a potentially explosive mixture. Obviously, propane leaks should be avoided, so set up the propane supply with utmost care. Read enclosed Odor Fade and Propane Sheet for additional information about detecting propane leaks. Leak check new connections or reconnections with a soap and water solution and follow all connection instructions herein. Also, ask your propane dealer for advice on the propane application and supply installation and ask him to check it if there are any questions.
This heater was designed and certified for use as a construction heater in accordance with ANSI Standard Z83.7/ CGA 2.14-2000. Check with your local fire safety authority if you have any questions about your applications. Other standards govern the use of fuel gases and heat producting products in specific applications. Your local authority can advise you about these.
Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. CO can build up in a heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation are:
headache dizziness burning eyes and nose nausea
dry mouth or sore throat So, be sure to follow advice about ventilation in these operating instructions.
Forced Air means that a blower or fan pushes the air through the heater. Proper combustion depends upon this air flow; therefore, the heater must not be revised, modified or operated with parts removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved.
SAFETY PRECAUTIONS
1.Check the heater thoroughly for damage. DO NOT operate a damaged heater.
2.DO NOT modify the heater or operate a heater which has been modified from its original condition.
3. Use only propane gas.
4.Use only VAPOR WITHDRAWAL propane supply. If there is any question about vapor withdrawal, ask your propane dealer.
5.Mount the propane cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them from damage.
6.Locate propane containers at least (USA) 7 ft. (2.13m), (Canada) 10 ft. (3m) from the heater and do not direct exhaust toward containers.
7.IMPORTANT Use only the hose and regulator assembly provided with the heater. Match the color stripe on the hangtag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater.
8.For indoor use only. Area must be well ventilated. Figure 1. (also see "Operating Precautions").
9.If at any time gas odor is detected, IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected. Read enclosed Odor fade and Propane Sheet for additional information about detecting propane leaks.
10.Install the heater such that is is not directly exposed to water spray, rain and/or dripping water.
11. Maintain minimum clearance from normal combustible material (like paper). Figure 2.
12. Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition.
13. Operate only on a stable, level surface.
14.Do not use with ductwork. Do not restrict inlet or exit.
15.Use only the electrical power specified. The electrical connection and grounding must comply with National Electrical Code - ANSI/NFPA 70 (USA) and CSA C22.1 Canadian Electrical Code, Part 1 (Canada).
16.Use only a properly grounded 3-prong receptacle or extension cord.
17.Do not move, handle or service while hot or burning.
18.Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.
VENTILATION: Minimum openings required
Heater near floor near ceiling
Infrared ...............................................................1 ft
Convection (25-VC) ........................................... 1 ft
Convection (All others) ...................................... 2 ft
Radiant................................................................ 2 ft
Forced air (30K-125K BTU/HR).......................... 1 ft
Forced air (150-FAST, SPC-150T) .................... 2 ft
Forced air (3500-FACV, SPC-350).................... 3 ft
Forced air (7000-FACV) .................................... 4 ft
Figure 1
Opening Opening
2
.....................
2
.....................
2
.....................
2
.....................
2
.....................
2
.....................
2
.....................
2
.....................
1 ft 1 ft 2 ft 2 ft 1 ft 2 ft 3 ft 4 ft
2 2 2 2 2 2 2 2
MINIMUM CLEARANCE: From normal combustible material
Figure 2
Radiant Forced Air Clearance Infrared Convection Forced Air 7000-FACV
From floor ........................................................... 0 ft .............. 0 ft
From outlet .......................................................... 6 ft .............. 10 ft
From sides ................ 3 ft............ 4 ft ............... 2 ft .............. 3 ft
From top....................................... 6 ft ............... 3 ft .............. 5 ft
From front .................6 ft
From rear ..................2 ft
Locate 10 ft. from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action.
Page -4-
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
• Do not use this heater for heating human living quarters.
• Do not use in unventilated areas.
• The flow of combustion and ventilation air must not be obstructed.
• Proper ventilation air must be provided to support the combustion air requirements of the heater being used.
• Refer to the specification section of the heater’s manual,
FUEL GAS ODOR LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks. If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor.
• Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
• Get everyone out of the building and away from the area immediately.
• Close all propane (LP) gas tank or cylinder fuel supply valves, or the main fuel supply valve located at the meter if you use natural gas.
• Propane (LP) gas is heavier than air and may settle in low
ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
heater dataplate, or contact the Scheu Products Company to determine combustion air ventilation requirements of the heater.
• Lack of proper ventilation air will lead to improper combustion.
• Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing.
areas. When you have reason to suspect a propane leak, keep out of all low areas.
• Use your neighbor’s phone and call your fuel gas supplier and your fire department. Do not re-enter the building or area.
• Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier.
• FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you.
ODOR FADING - NO ODOR DETECTED
• Some people cannot smell well. Some people cannot smell the odor of the man-made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases.
• Learn to recognize the odor of propane (LP) gas and natural gas. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.
• Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor.
ATTENTION - CRITICAL POINTS TO REMEMBER!
• Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Fuel Gas Odor and Odor Fading sections above.
• Even If you are not property trained in the service and repair of the heater, ALWAYS be consciously aware of the odors of propane (LP) gas and natural gas.
• If you have not been properly trained in repair and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system.
The odorant in propane (LP) gas and natural gas is
colorless and the intensity of its odor can fade under some circumstances.
• If there is an underground leak, the movement of gas through the soil can filter the odorant.
• Propane (LP) gas odor may differ in intensity at different levels. Since Propane (LP) gas is heavier than air, there may be more odor at lower levels.
• Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously.
• A periodic sniff test around the heater or at the heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!
Page -5-