OWNER’S MANUAL
For more information, visit www.desatech.com
For more information, visit www.desatech.com
MODELS
BLP50VA
REM50PVA
Variable
30,000, 40,000,
50,000 Btu/Hr
IMPORTANT: Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX­IDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
TABLE OF CONTENTS
SAFETY INFORMATION ............................................................ 2
PRODUCT IDENTIFICATION ..................................................... 3
UNPACKING............................................................................... 3
PROPANE SUPPLY.................................................................... 3
THEORY OF OPERATION ......................................................... 4
ASSEMBLY................................................................................. 4
INSTALLATION ........................................................................... 4
VENTILATION ............................................................................. 5
OPERATION ............................................................................... 5
STORAGE................................................................................... 6
MAINTENANCE .......................................................................... 6
TROUBLESHOOTING ................................................................ 7
SERVICE PROCEDURES .......................................................... 8
ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST....... 10
SPECIFICATIONS .................................................................... 12
ACCESSORY............................................................................ 12
REPLACEMENT PARTS .......................................................... 12
OWNER’S REGISTRATION FORM .......................................... 13
WARRANTY AND REPAIR SERVICE ........................Back Cover
Save this manual for future reference.
Save this manual for future reference.
Page 2
SAFETY INFORMATION
2
SAFETY INFORMATION
WARNINGS
WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.
WARNING: FIRE, BURN, INHALATION, AND EX­PLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARD­BOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUC­TIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASO­LINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE.
The heater is designed for use as a construction heater in accordance with ANSI Z83.7/CGA 2.14. Other standards govern the use of fuel gases and heating products for specific uses. Your local authority can advise you about these. The primary purpose of construction heaters is to provide temporary heating of buildings under construction, alteration or repair. Properly used, the heater provides safe economical heating. Products of combustion are vented into the area being heated.
We cannot foresee every use which may be made of our heaters.
CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT HEATER USE.
Other standards govern the use of fuel gases and heat producing products for specific uses. Your local authorities can advise you about these.
Carbon Monoxide Poisoning: Some people are more affected by
carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau­sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Check for proper ventilation and have heater serviced.
Propane Gas: Propane gas is odorless. An odor-making agent is
added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas may fade. Propane gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
• Install and use heater with care. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the Standard for
Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58
and the Natural Gas Installation Code, CAN/CGA B149.2. This in­structs on the safe storage and handling of propane gases.
• Use only the electrical voltage and frequency specified on model plate.
• The electrical connections and grounding of the heater shall fol­low the National Electric Code, ANSI/NFPA 70, or Canadian Electrical Code, part 1.
• Electrical grounding instructions — This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
• Use only a three-prong, grounded extension cord.
• Use only the hose and factory preset regulator provided with the heater.
• Use only propane gas set up for vapor withdrawal.
• Provide adequate ventilation. Before using heater , provide at least a 1.5-square-foot opening of fresh, outside air.
• This product has been approved for use in the Commonwealth of Massachusetts.
• For indoor use only. Do not use heater outdoors.
• Do not use heater in occupied dwellings or in living or sleep­ing quarters.
• Do not use heater below ground level. Propane gas is heavier than air. If a leak occurs, propane gas may sink to the lowest possible level.
• Keep appliance area clear and free from combustible materials, gasoline, paint thinner, and other flammable vapors and liquids. Do not use heater in areas with high dust content.
• Minimum heater clearances from combustibles: Outlet: 6 Ft. Sides: 2 Ft. Top: 6 Ft. Rear: 2 Ft.
• Keep heater at least six feet from propane tank(s). Do not point heater at propane tank(s) within 20 feet.
• Keep propane tank(s) below 100° F.
• Check heater for damage before each use. Do not use a dam­aged heater.
• Check hose before each use of heater. If highly worn or cut, replace before using heater.
• Locate heater on stable and level surface if heater is hot or operating.
• Not intended for use on finished floors.
• Never block air inlet (rear) or air outlet (front) of heater.
• Keep heater away from strong drafts, water spray, rain, or drip­ping water.
• Do not leave heater unattended.
• Keep children and animals away from heater.
• Never move, handle, or service a hot, operating, or plugged-in heater. Severe burns may result. Wait 20 minutes after turning heater off.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105331-01D
Page 3
SAFETY INFORMATION
PRODUCT IDENTIFICATION
UNPACKING
PROPANE SUPPLY
3
3
SAFETY INFORMATION
Continued
• To prevent injury, wear gloves when handling heater.
• Never attach duct work to heater.
• Do not alter heater. Keep heater in its original state.
• Do not use heater if altered.
• Turn off propane supply and unplug heater when not in use.
• Use only original replacement parts. This heater must use de­sign-specific parts. Do not substitute or use generic parts. Im­proper replacement parts could cause serious or fatal injuries.
PRODUCT IDENTIFICATION
Hot Air Outlet (Front)
Heater Base
Piezo Ignitor Button
Automatic Control Valve Knob
Shell
Handle
Motor
Fan
Power Cord
Valve Inlet
UNPACKING
1. Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to inlet connector and hose/regu­lator assembly) for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
PROPANE SUPPLY
Propane gas and propane tank(s) are to be furnished by the user. Use this heater only with a propane vapor withdrawal supply system.
See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA B149.2. Your local library or fire department will have this booklet.
The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount:
1. The amount of propane gas in tank(s)
2. The temperature of tank(s)
This heater is designed to operate with a minimum 20-pound propane tank. You may need two or more tanks or one larger tank in colder weather. Use a 100-pound tank for longer operation or in very cold weather. Less gas is vaporized at lower temperatures. Your local propane gas dealer will help you select the proper supply system. The minimum surrounding air temperature rating for each heater is -20°F (-29°C).
Average Number Of Temperature (°F) Tanks At Tank Location (100-pound)
40° 1 32° 1 20° 1 10° 1
0° 1
-10° 2
-20 ° 2
Hose / Regulator Assembly
Figure 1 - 50,000 BTU/Hr Model
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105331-01D
Page 4
THEORY OF OPERATION ASSEMBLY
4
INSTALLATION
THEORY OF OPERATION
The Fuel System: The hose/regulator assembly attaches to the
propane gas supply. This provides fuel to the heater.
The Air System: The motor turns the fan. The fan pushes air into and
around the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The piezo ignitor lights the burner. The Automatic Control System: This system causes the heater to
shut down if the flame goes out.
Combustion Chamber
Clean Heated Air Out (Front)
Air For Combustion Air For Heating
Figure 2 - Cross Section Operational View
Fan
Motor
Cool Air In (Back)
Hose/ Regulator Assembly
Flat Side Facing Up
Nut Clip
Shell
Slot
Figure 4 - Installing Nut Clip
Screws
Handle
Nut Clip
Rear of Heater
ASSEMBLY
1. Remove screw from top of fan guard (see Figure 3). Dis­card screw.
2. Insert nut clip (provided with handle) with flat side facing up through slot in top of shell. Align holes in nut clip with screw hole behind slot in top of shell. (see Figure 4).
3. Place handle over hole and clip. Insert two screws (provided with handle) through handle and tighten into shell. Make sure rear screw goes through shell and into fan guard. Tighten screws firmly.
Screw
Figure 3 - Removing Screw from Top of Fan Guard
Figure 5 - Attaching Handle
INSTALLATION
WARNING: Review and understand the warnings
in the
Safety Information
are needed to safely operate this heater. Follow all local codes when using this heater.
WARNING: Test all gas piping and connections for leaks after installation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
1. Provide propane supply system (see Propane Supply, page 3).
2. Connect fuel gas fitting on hose/regulator assembly to pro­pane tank(s). Turn fuel gas fitting counterclockwise into threads on tank. Tighten firmly using a wrench. tion regulator so that hose leaving the regulator is in a hori­zontal position (see Figure 6, page 5). This places the regula­tor vent in the proper position to protect it from the weather.
section, pages 2 and 3. They
IMPORTANT:
Posi-
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105331-01D
Page 5
INSTALLATION
VENTILATION
OPERATION
5
5
INSTALLATION
Continued
3. Connect hose to valve inlet. Tighten firmly using a wrench. You must use the regulator supplied with heater.
Note:
4. Open propane supply valve on propane tank(s) slowly. not opened slowly, excess-flow check valve on propane tank may stop gas flow. If this happens, close propane supply valve and open again slowly.
5. Check all connections for leaks. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected.
6. Close propane supply valve.
WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak that must be corrected. Correct all leaks at once.
Propane Supply Valve
Propane Tank
Figure 6 - Regulator Position
Fuel Gas Fitting
Regulator
If
Hose
VENTILATION
WARNING: Provide at least a 1.5 square foot opening of fresh, outside air while running heater. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.
OPERATION
WARNING: Review and understand the warnings in the
Safety Information
are needed to safely operate this heater. Follow all local codes when using this heater.
TO START HEATER
1. Follow all installation, ventilation, and safety information.
2. Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.
3. Plug power cord of heater into a three-prong, grounded exten­sion cord. Extension cord must be at least six feet long. Exten­sion cord must be UL listed.
Extension Cord Wire Size Requirements
Up to 50 feet long, use 18 AWG rated cord. 51 to 100 feet long, use 16 AWG rated cord. 101 to 200 feet long, use 14 AWG rated cord.
4. Plug extension cord into a 120 volt/60 hertz, 3-hole, grounded outlet. Motor will start. Fan will turn, forcing air out front of heater.
5. Open propane supply valve on propane tank(s) slowly. not opened slowly, excess-flow check valve on propane tank may stop gas flow. If this happens, close propane supply valve and open again slowly .
section, pages 2 and 3. They
Note:
If
Knob
Valve Inlet
Hose
Figure 7 - Hose and Inlet Connector
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105331-01D
WARNING: Be sure motor and fan are running before pushing in automatic control valve button. Flames could flash outside heater if motor and fan are not running.
6. Turn control knob to the low position and push in (see Figure 8 and 9, page 6). Hold knob in and push piezo ignitor button. You may need to push piezo ignitor button 3-8 times until the main burner lights. When main burner lights, keep automatic control valve knob pushed in. Release button after 30 seconds.
Note:
If main burner fails to light, hose may have air in it. If so, keep control knob pressed and wait 20 seconds. Release control knob and wait 20 seconds for unburned fuel to exit heater. Repeat step 6.
Page 6
OPERATION
6
STORAGE MAINTENANCE
OPERATION
Continued
7. If main burner goes out, repeat step 6, page 5.
8. When main burner remains lit, rotate control knob to the de­sired heat level.
OFF
START/ LOW
MED
HIGH
Figure 8 - Control Knob Positions
Piezo Ignitor Button
Automatic Control Valve Knob
Figure 9 - Automatic Control Valve Button and Piezo Ignitor Button
TO STOP HEATER
1. Tightly close propane supply valve on propane tank(s). Allow heater to burn remaining fuel in hose.
2. Shut off main burner valve. Do this by turning control knob to the OFF position until it stops.
TO RESTART HEATER
1. Wait five minutes after stopping heater.
2. Repeat steps under To Start Heater, page 5.
STORAGE
CAUTION: Disconnect heater from propane sup-
ply tank(s).
1. Store propane tank(s) in safe manner. See Chapter 5 of Stan­dard for Storage and Handling of Liquefied Petr oleum Gases, ANSI/NFPA 58. Follow all local codes. Always store propane
tanks outdoors.
2. Place plastic cover caps over brass fittings on inlet connector and hose/regulator assembly.
3. Store in dry , clean, and safe place. Do not store hose/regulator assembly inside heater combustion chamber.
4. When taking heater out of storage, always check inside of heater. Insects and small animals may place foreign objects in heater. Remove motor and other internal parts if needed to re­move foreign objects (see Service Procedures, page 8).
MAINTENANCE
WARNINGS
• Never service heater while it is plugged in, con­nected to propane supply, operating, or hot. Se­vere burns and electrical shock can occur.
• Keep heater clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
• Do not block the flow of combustion or ventila­tion air.
1. Keep heater clean. Clean heater annually or as needed to re­move dust and debris. If heater is dirty or dusty, clean heater with a damp cloth. Use household cleaners on difficult spots.
2. Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.
3. Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace.
4. Have heater inspected yearly by a qualified service agency.
5. Keep inside of heater free from combustible and foreign ob­jects. Remove motor and other internal parts if needed to clean inside of heater (see Service Procedures, page 8).
6. Clean fan blades each season or as needed (see Fan, page 8).
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105331-01D
Page 7
TROUBLESHOOTING
Note:
For additional help, visit DESA Heating Products’ Tech-
nical Service web site at www.desatech.com.
TROUBLESHOOTING
WARNING: Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur.
7
7
OBSERVED FAULT
Fan does not turn when heater is plugged in.
Heater will not ignite.
Heater shuts down while running.
POSSIBLE CAUSE
1. No electrical power to heater
2. Fan hitting inside of heater shell
3. Fan blades bent
4. Defective motor
1. User did not follow installation or op­eration instructions properly
2. No spark at ignitor. T o test for spark, fol­low step 9 under Ignitor, page 9. If you see spark at ignitor, have heater serviced by qualified service person. If no spark seen: A) Loose or disconnected ignitor wire B) Wrong spark gap C) Piezo ignitor loose D) Bad ignitor electrode
1. High surrounding air temperature caus­ing thermal limit device to shut down heater
2. Restricted air flow
3. Damaged fan
4. Excessive dust or debris in surrounding area
REMEDY
1. Check voltage to electrical outlet. If volt­age is good, check heater power cord for breaks
2. Adjust motor/fan guard to keep fan from hitting inside of heater shell. Bend fan guard if necessary
3. Replace fan. See Fan, page 8
4. Replace motor. See Motor, page 8
1. Repeat installation and operation in­structions. See Installation, page 5 and Operation, pages 5 and 6
2. A) Check ignitor wire. Tighten or reat­tach loose ignitor wire. See Figure 17, page 9 for ignitor wire location B) Set gap between ignitor electrode and target plate to .17" C) Tighten nut holding piezo ignitor to base of heater D) Replace ignitor electrode. See Igni- tor, page 9
1. This can happen when running heater in temperatures above 85°F . Run heater in cooler temperatures
2. Check heater inlet and outlet. Remove any obstructions
3. Replace fan. See Fan, page 8
4. Clean heater. See Maintenance, page 6
105331-01D
WARNING: Use only in areas free of high dust content.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Page 8
SERVICE PROCEDURES
8
SERVICE PROCEDURES
WARNING: Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur.
ELECTRICAL SYSTEM
The entire electrical system for this heater is contained within the motor. If any part of the electrical system is damaged, you must replace motor.
Setscrew
MOTOR
1. Remove three screws that attach fan guard to heater shell.
2. Remove motor and fan guard from heater shell (see Figure 10).
3. Use hex wrench to loosen set screw which holds fan to motor shaft (see Figure 11). Remove fan. Be careful not to damage the fan blade pitch.
4. Remove two nuts and two screws that attach fan guard to motor using nut-driver. Remove fan guard from motor (see Figure 12).
5 Disconnect the green power cord wire from motor and remove
black and white wire terminals.
6. Discard old motor.
7. Attach green power cord wire to motor.
8. Attach fan guard to new motor with two nuts and two screws.
9. Replace black and white terminals.
10. Place fan onto motor shaft of new motor. Make sure set screw contacts flat surface on motor shaft. Tighten set screw firmly (40-50 inch-pounds).
11. Place motor and fan guard into rear of heater shell. Make sure power cord is properly located (see Figure 13).
12. Insert three screws through heater shell and into fan guard. Tighten screws firmly.
Figure 10 - Removing Motor and Fan Guard from Heater
Figure 12 - Removing or
Figure 11 - Setscrew Location
Figure 13 - Replacing Motor and Fan Guard into Heater
Attaching Fan Guard from Motor
FAN
1. Remove three screws that attach fan guard to heater shell.
2. Remove motor and fan guard from heater shell (see Figure 10).
3. Use hex wrench to loosen set screw that holds fan to motor shaft (see Figure 11).
4. Remove fan. Be careful not to damage the fan blade pitch.
5a. If replacing fan, remove old fan and discard. Go to step 7 below. 5b. If cleaning fan, use soft cloth moistened with kerosene or solvent.
6. Dry fan thoroughly.
7. Place fan onto motor shaft. Make sure set screw contacts flat sur­face on motor shaft. Tighten set screw firmly (40-50 inch-pounds).
8. Place motor and fan guard into rear of heater shell. Make sure power cord is properly located (see Figure 13).
9. Insert three screws through heater shell and into fan guard. Tighten screws firmly.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105331-01D
Page 9
SERVICE PROCEDURES
Continued
SERVICE PROCEDURES
9
9
IGNITOR
1. Remove motor and fan guard from heater (see Motor, page 8, steps 1 through 5).
2. Remove black ignitor wire from piezo ignitor. Access ignitor wire through underside of heater base (see Figure 14). Push wire up through bushing in heater shell.
3. Remove ignitor mounting screw from rear head using nut-driver or standard screwdriver (see Figure 15).
4. Remove ignitor from rear head.
5. Install new ignitor. Attach ignitor to rear head with ignitor mounting screw.
6. Run ignitor wire from new ignitor through bushing in heater shell. Attach ignitor wire to piezo ignitor.
7. Set gap between ignitor electrode and target plate to .17" (see Figure 16).
WARNING: Make sure heater is disconnected from propane supply. Heater could ignite causing severe burns.
8. Test for spark. Push piezo ignitor button and watch for spark between ignitor electrode and target plate.
9. Place motor and fan guard into rear of heater shell (see Motor, page 8, steps 9 through 10).
Rear Head
Ignitor
Ignitor Mounting Screw
Figure 15 - Removing Ignitor Mounting Screw and Ignitor
Ignitor
Target Plate
Figure 16 - Clearance between Ignitor Electrode and Target Plate
Electrode
Gap Area
Piezo Ignitor
Ignitor Wire
Figure 14 - Removing Ignitor Wire from Piezo Ignitor
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105331-01D
Bushing
Underside of Heater Base
Page 10
ILLUSTRATED PARTS BREAKDOWN
10
Models BLP50VA and REM50PVA
ILLUSTRATED PARTS BREAKDOWN
MODELS BLP50VA AND REM50PVA
1
23
22
2
24
19
2
3
2
21
29
4
16
20
10
11
18
17
9
20
21
12
13
6
15
27
25
8
For more information, visit www.desatech.com
For more information, visit www.desatech.com
26
14
7
5
28
105331-01D
Page 11
PARTS LIST
MODELS BLP50VA AND REM50PVA
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual.
KEY PART NO. NUMBER DESCRIPTION QTY.
1 ** Combustion Chamber 1 2 M11084-26 Hex Tap Screw, #10-16 x 3/8" 7 3 105333-04 Outer Shell (BLP50VA) 1
105333-02 Outer Shell (REM50PVA) 1 4 104786-01 Handle Kit 1 5 M11143-1 Bushing, Strain Relief 1 6 101480-12 Wire Assembly 1 7 M11084-27 Hex Tap Screw, #12-14 x 1/2" 3 8 099393-03 Knob, Control 1 9 105341-01 Burner Assembly 1 10 099539-01 Electrode Ignitor 1 11 M11084-38 Hex Tap Screw, #8-18 x 3/8" 1 12 101478-03 Fan 1 13 105332-01 Motor 1 14 103863-01 Fan Guard 1 15 097384-02 Captive Washer Nut 3 16 097968-05 Hex Screw, #4-40 x 1/2" 2 17 NPC-00C Hex Nut, #4-40 2 18 101481-04 Thermal Switch 1 19 097776-01 Universal Bushing 1 20 099237-01 Thermocouple Nut 2 21 104146-02 Thermocouple 1 22 103921-01 Valve/Orifice Assembly 1 23 102445-01 Piezo Ignitor 1 24 078978-03 Sleeve Cap 1 25 105335-01 Base Assembly 1 26 099202-02 Steel Rivet, 1/8" 1 27 M12461-14 Hex Screw, 8-32 x 3/8 2 28 098219-25 Cord, Power Supply 1 29 097403-01 Screw, Phillips Head #10x1.25" (Black) 2
Models BLP50VA and REM50PVA
PARTS LIST
11
11
105331-01D
PARTS AVAILABLE - NOT SHOWN
097650-01 Tradename Decal (BLP50VA) 2
110789-01 Tradename Decal (REM50PVA) 2
103867-09 General Information Decal 1
103869-03 Operation Decal 1
099672-01 Notice Decal 1
111632-04 Model Data Decal 1
LPA3055 Hose/Regulator Assembly 1 ** Not a field replaceable part.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Page 12
12
SPECIFICATIONS ACCESSORY REPLACEMENT PARTS TECHNICAL SERVICE
SPECIFICATIONS
Output Rating (BTU/Hr)
High......................................................49,500
Medium ................................................40,000
Low ......................................................30,000
Fuel ............................................................Propane Vapor Only
Fuel Consumption
Gallons/Hour ........................................2.19 / 1.09
Pounds/Hour.........................................9.28 / 4.64
Supply Pressure To Regulator
Minimum (for input adjustment)..........10 psi
Maximum .............................................200 psi
Regulator Outlet Pressure
High......................................................18" WC
Manifold Pressure
High......................................................13.7" WC
Low ......................................................17" WC
Hot Air Output (CFM Approx) .................275
Motor .........................................................3,300 RPM, 1/20 HP
Electric Input .............................................120 volt/60 hertz
Amperage ..................................................2
Ignition ......................................................Manual, Piezo
Ignitor Gap.................................................0.17"
Temperature Range for Operation*...........-20°F to 85°F *
Heater Weight (Pounds) ............................13
Shipping Weight ........................................15
Size - L x W x H (Inches)
Heater ...................................................18.5 x 8.0 x 12.8
Carton...................................................19.4 x 9.75 x 14.75
* When running heater in temperatures above 85° F, high internal temperatures may cause thermal limit device to shut down heater.
REPLACEMENT PARTS
WARNING: Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replace­ment parts could cause serious or fatal injuries. This will also protect your warranty coverage for parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest authorized service center or call DESA Heating Products' Technical Service Department at 1-866-672-6040.
When calling DESA Heating Products, have ready
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• purchase date In most cases, we will ask you to return the part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Cen­tral or call DESA Heating Products at 1-866-672-6040 for referral information.
When calling DESA Heating Products, have ready
• model number of your heater
• the replacement part number
ACCESSORY
Purchase accessories and parts from your nearest dealer or service center. If they can not supply an accessory or part, either contact your nearest Parts Central (listed in the separate Authorized Service Center booklet) or contact DESA Heating Products for information.
DESA Heating Products P.O. Box 90004 Bowling Green, KY 42102-9004 1-866-672-6040
Part Number Description
LPA4020 Fuel Gas Connector
Connects regulator to all standard propane tanks. U.L. and A.G.A. listed.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
TECHNICAL SERVICE
You may have further questions about this heater. If so, contact DESA Heating Products' Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.
You can also visit DESA Heating Products' Technical Service web site at www.desatech.com.
105331-01D
Page 13
13
13
OWNER'S REGISTRATION FORM
Complete registration form and mail or complete on-line registration at www.desatech.com within 30 days after purchase.
Brand: Model: Date Purchased: Serial Number: First Name: Last Name: Address: City: State: Zip: Country: Phone: ( ) - E-Mail:
Please answer the following questions to register your product with DESA Heating Products:
1. Who will heater be used by? Individual Business
2. Will you use your heater in more than one location? Yes No
3. Where will the product be used? (You may select more than one.) Workshop Barn Residential Construction
Commercial Construction Garage Factory Recreation Warehouse Utility Shed/Outbuilding Other ______________________________ (Specify)
4. Cost of product (excluding sales tax)? $________________________________
5. Maintenance/service work will be performed by: Self Service Center Other ___________________________________
6. If you bought this product yourself, did you plan to purchase this type of product before going into the store? Yes No
7. Type of store where product was purchased? Hardware Propane Dealer Natural Gas/Utility Co. Home Center or Builders Supply Farm/Ag. Supply Auto Parts Warehouse Club Industrial/Contractor Supply Rental Store Discount Store HVAC Dealer Other _________________________________________________
8. What is your primary source of heat? Propane (LP Gas) Natural Gas Kerosene Diesel Electric Other________________
9. What motivated you to buy this product? Sudden Cold Weather Replace Older Model D.I.Y. Home Project Emergency Back-Up Heat Heater on Sale Construction Project Hard to Heat Location Other ________________________________
10. How did you learn about this product brand? Advertisement Relative or Friend Co-Worker Store Representative Store Display Previously Owned a Heater Other _________________________________________________(Specify)
11. What other brands did you consider? None Master Remington All-Pro Dayton Universal Mr. Heater L.B. White Tradesman John Deere Dyna-Glo Dura-Heat Paulin Coleman Vogelzang American Other ___________________________________
12. Who selected the product? Male Female Both
13. Level of Education of Purchaser: High School Vocation/Technical School Some College Completed College Graduate School
14. Age of Purchaser: Under 20 20 - 29 30 - 39 40 - 49 50 - 59 60 or Over
15. Buyers total annual household income: Under $19,999 $20,000 to $34,999 $35,000 to $49,999 $50,000 to $74,999 $75,000 to $99,999 $100,000 and Over
16. What is the population of your area? Under 10,000 10,000 to 25,000 25,000 to 50,000 50,000 to 100,000 100,000 to 250,000 Over 250,000
17. Store where product was purchased: Name: ______________________________________ City: _____________________________________ State: __________
18. In choosing this product, how important were the following:
Availability Price Brand Name Overall Quality Heat Output (Btu/Hr Rating) Variable Heat Output (Btu/Hr) Made in USA Warranty Local Service Value for Price
Not Somewhat Very
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
(Reddy Heater, Master, Remington, etc.) (R60, HD15, etc.)
Note:
Keep receipt for warranty verification.
7 or 9 digit number located on product or identification tag.
Not Somewhat Very
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
Size Prior Brand Experience Built-In Thermostat Ease of Operation Special Features Salespersons Recommendation Friend/Relatives Recommendation Portability Quiet Operation
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
19. This question will allow us to better understand the demographic profile of our customers. Which of the following best describes you? (not required) African American Asian American Mexican Puerto Rican Cuban Other Hispanic White Other ___________________
105331-01D
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Page 14
TAPE
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
Postage
Required
TAPE
Page 15
OTHER OUTDOOR HEATING PRODUCTS
PROPANE/LP FORCED AIR HEATERS
PROPANE/LP CONVECTION HEATERS
l ; l d
l ; l
p
l
;
;
l
l
d
;
l ; l
; l
d
p
; d d
p
;
e
;
;
p
l
p
;
;
;
g
;
d
;
e
;
o l
p
e
;
;
;
g
e
,
;
e
;
,
;
g
o
l
g
; g
o l
,
e
e
o
l
;
,
;
l
o l
,
;
k
;
,
g
,
,
e
,
o
l ,
o l
e
k
k l
;
e
,
l
e
i
k
o l
,
k
h
k k
o
l
o
e
i k o
l
k
k
i
h k
k
e
l
i
i
h
o
k
o
l
h l
h
k
k
e l
b
k
i
l
k
e
o
j
e
h
i
e
o
l
e
b
o
i
l
h
k
o
l
j
l
b
u
;
l
e
b
j
e
l
k
l
b
s
i
j
l
o
l
j
e
e
d
i
u
e
k
i
e
b
o
p
s
i
u
l
l
l
;
j
u
;
s
u
l
;
l
k l
b
s
e
;
l
s
l
i
l
d l k
l
j
;
k
u
l
d
p
e
l
k
e
; ;
;
l
s
i
l
d
p
;
l
;
l
;
l
;
g
l
d
p
;
u
k
;
d
o
d
p
;
e
s
l
l
;
;
l
;
p
;
l
p
;
e
;
,
;
;
g
k
;
,
d
;
e
l
;
g
o
;
l
p
e
l
;
e
;
;
g
o
e
l
,
l
;
e
;
d
;
,
;
g
o l
,
k
g
p
;
,
g
o l
,
e
;
e
o
o
l
;
,
;
l
o
;
l
,
e
;
k
k
l
;
,
g
,
,
e
,
i
k
o
l
,
o
e
l
e
k
;
h
k
o
l
;
e
l
,
l
e
i
k
k
o
g
l
,
k
k
i
h
k
k
o
o
l
e
o
l
e
i
h
k
o
l
k
l
;
k
o
,
i
h
k
k
k
e
l
,
i
i
h
o
k
e
o
b
l
h
l
e
l
h
k
k
e
o
j
l
l
b
k
i
l
k
e
o
e
k
j
b
i
e
h
l
e
o
l
o
j
e
b
o
u
i
l
k
o
k
j
e
b
s
i
u
l
e
b
l
i
j
e
l
b
s
i
u
j
l
o
l
k
j
e
h
s
l
i
u
l
e
k
l
;
i
e
b
s
i
u
l k
l
k
l j
u
s
u
e
d
k
l s e
WARNING
l
s
i
k
o
p
l
k
;
u
k
;
l
b
s ; l
l j
k
e e ; i
u s l
l;l
e
dl
l;l
b o
dl;l
;;pd
dl;l
;;p
dl;l
iejl
;e
u
;;pd
;e ;;pdl;l
;e ;;p
ls ;e ;;p
,,;log;e
g;e
g
,,;log
l;lk
g;e ;;p
G
,,;log
,,;lo
,,;lo
i kokle
kle
le
;;pd
kle ,,;lo
kle
;e
ok
N
eklh
g
i ko
eklhi kokle
i k
I
i ko
klhi ko
klh
lh
,,;lo
jlb o
oe
iejlb o
eklh
ek
le
ie
jlb
o
N
ok
b o
iejlb oe
jlb
i k
l;l klsu d
lh
uiejl
R
k
ls
dl;l klsuiejlb oeklhi kokle ,,;log
e
l;l klsu
dl;l klsuie
;;p
d
;;pdl;l klsu
o
dl;l
l;lk
dl;l klsuie
;e
g;e
jlb
A
;;p
ie
g;e ;;p
;;p
;e
;;pd
lsu
;e
k
,,;log;e ;;p
,,;log
W
,,;log;e
i kokle ,,;lo
kle ,,;log;e ;;p
kle
kle
eklh
i kokle
klhi kokle ,,;lo
o
klhi ko
jlb
eklh
oe
eklhi ko
oe
eklhi ko
o
iejlb oeklhi kokle ,,;log
jlb
jlb
o
ie
jlb jlb o
ie
jlb
klsu
ie
;l klsuie
klsu
klsuie
klsu klsu
klsuie
k
PROPANE/LP TANK TOP HEATERS
PROPANE/LP AND NATURAL
GAS GARAGE HEATERS
PORTABLE KEROSENE/DIESEL
FORCED AIR HEATERS
PROPANE/LP
PATIO HEATERS
PROPANE/LP AND NATURAL
GAS CHIMENEAS
Page 16
16
WARRANTY AND REPAIR SERVICE
KEEP THIS WARRANTY
Model Serial No. Date of Purchase
LIMITED WARRANTY
DESA Heating Products warrants this product and any parts thereof, to be free from defects in materials and workmanship for one (1) year from the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail purchaser, when proof of purchase is provided.
This warranty covers only the cost of parts and labor required to restore the product to proper operating condition. Transportation and incidental costs associated with warranty repairs are not reimbursable under this warranty.
Warranty service is available only through authorized dealers and service centers. This warranty does not cover defects resulting from misuse, abuse, negligence, accidents, lack of proper maintenance, normal wear, alteration,
modification, tampering, contaminated fuels, repair using improper parts, or repair by anyone other than an authorized dealer or service center. Routine maintenance is the responsibility of the owner.
THIS EXPRESS WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTY EITHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
DESA Heating Products assumes no responsibility for indirect, incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations or exclusions may not apply to you. This Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
WARRANTY SERVICE
Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA Heating Products will repair or replace the heater without charge.
REPAIR SERVICE
Return your heater to your nearest authorized service center. Repairs not covered by the warranty will be billed at standard prices. Each Service Center is independently owned and operated. We reserve the right to amend these specifications at any time without notice.
When writing for information regarding your heater, be sure to include the model number and serial number as shown on the model plate. For more information about this warranty, write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
ATTN: Customer Service Department
105331 01
NOT A UPC
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105331-01 Rev. D 08/03
105331-01D
Loading...